Search NASA⌕ Search

SEARCH · Search NASA

Results for “TUNGSTATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Laser Response in ECAL Crystals in CMS Detector

The dataset contains the Laser responses of the Lead-Tungstate crystals in the Electromagnetic Calorimeter (ECAL) of the CMS Experiment recorded during the Run 2 (2016-2018) of LHC running. The datasets consists of two tar folders: one corresponding to the "plus" side of the detector and one corresponding to the "minus" side. Each folder contains files in csv format, each file corresponding to the histories of all crystals in each "ieta" ring. The detailed description of the columns can be found under the section names "dataset" on Github pages at https://fair-umn.github.io/fair_ecal_monitoring.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Application of thermodynamics to silicate crystalline solutions

A review of thermodynamic relations is presented, describing Guggenheim's regular solution models, the simple mixture, the zeroth approximation, and the quasi-chemical model. The possibilities of retrieving useful thermodynamic quantities from phase equilibrium studies are discussed. Such quantities include the activity-composition relations and the free energy of mixing in crystalline solutions. Theory and results of the study of partitioning of elements in coexisting minerals are briefly reviewed. A thermodynamic study of the intercrystalline and intracrystalline ion exchange relations gives useful information on the thermodynamic behavior of the crystalline solutions involved. Such information is necessary for the solution of most petrogenic problems and for geothermometry. Thermodynamic quantities for tungstates (CaWO4-SrWO4) are calculated.

Saxena, S. K.↗

Preparation of pigments for space-stable thermal control coatings

The identification and control of vapor phase reaction kinetics to produce pigments by homogeneous nucleation were achieved. A vapor phase apparatus was designed, fabricated, and calibrated through 1800 C. Vapor phase reactions were analyzed, calculations made, and powders of alumina, rutile, zinc orthotitanate (in a mixed phase), calcium tungstate, and lanthana were produced by homogeneous nucleation. Electron microscopy shows uniform particle morphology and size, and supports anticipated advantages of vapor-phase homogeneous nucleation; namely, purity, freedom from defects, and uniform particle sizing without grinding.

Campbell, W. B.↗

Development of aircraft brake materials

The requirements of brake materials were outlined and a survey made to select materials to meet the needs of high temperature brakes. A number of metals and ceramic materials were selected and evaluated in sliding tests which simulated aircraft braking. Nickel, molybdenum tungsten, Zr02, high temperature cements and carbons were tested. Additives were then incorporated into these materials to optimize their wear or strength behavior with particular emphasis on nickel and molybdenum base materials and a high temperature potassium silicate cement. Optimum materials were developed which improved wear behavior over conventional brake materials in the simulated test. The best materials are a nickel, aluminum oxide, lead tungstate composition containing graphite or molybdenum disulphite; a molybdenum base material containing LPA100 (an intermetallic compound of cobalt, molybdenum, and silicon); and a carbon material (P5).

Ho, T. L.↗

Development of aircraft brake materials

A program has been carried out to study and develop high temperature aircraft brake materials. A survey of the requirements of brake materials was made to select materials to meet these requirements. Based upon their physical and thermal properties, a number of materials were selected and evaluated in sliding tests which simulated aircraft braking. The mating material is 17-22 AS steel. Additives were incorporated into these materials to optimize their wear or strength behavior with particular emphasis on nickel and molybdenum base materials. Optimum materials were developed which had improved wear behavior over conventional brake materials in the simulated test. The best materials were a nickel, aluminum oxide, lead tungstate composition containing graphite and a molybdenum base material containing LPA 100 (an intermetallic compound of cobalt, molybdenum and silicon).

Ho, T.-L.↗

Thermionic converter performance with oxide collectors

Thermionic converters using a variety of metal oxide collector surfaces have been fabricated and tested. Both work function and power output data are presented and evaluated. Oxides of barium, strontium, zinc, tungsten and titanium have been incorporated into a variable spacing converter. Tungsten oxide was found to give the highest converter performance and to furnish oxygen for the emitter at the same time. Oxygenated emitters operate at reduced cesium pressure with an increase in electrode spacing. Electron spectroscopy for chemical analysis (ESCA) performed on several tungsten oxide collectors showed cesium penetration of the oxide layer, possibly forming a cesium tungstate bronze. Titanium oxide showed high performance but did not furnish oxygen for the emitter; strontium oxide, in the form of a sprayed layer, appeared to dissociate in the presence of cesium. Sprayed coatings of barium and zinc oxides produced collector work functions of about 1.3 eV, but had excessive series resistance. Lanthanum hexaboride, in combination with oxygen introduced through a silver tube, and cesium produced a low work function collector and better than average performance.

Lieb, D.↗

Design, construction and long life endurance testing of cathode assemblies for use in microwave high-power transmitting tubes

The cathode life test program sponsored by NASA Lewis Research Center at Watkins-Johnson Company has been in continuous operation since 1972. Its primary objective has been to evaluate the long life capability of barium dispenser cathodes to produce emission current densities of 2 A sq. cm. or more in an operational environment simulating that of a highpower microwave tube. The life test vehicles were equipped with convergent flow electron guns, drift space tubes with solenoid magnets for electron beam confinement and water-cooled depressed collectors. A variety of cathode types has been tested, including GE Tungstate, Litton Impregnated, Philips Type B and M, Semicon types S and M, and Spectra-Mat Type M. Recent emphasis has been on monitoring the performance of Philips Type M cathodes at 2 A sq. cm. and Sprectra-Mat and Semicon Type M cathodes at 4 A sq. cm. These cathodes have been operated at a constant current of 616 mA and a cathode anode voltage on the order of 10 kV. Cathode temperatures were maintained at 1010 C true as measured from black body holes in the backs of the cathodes. This report presents results of the cathode life test program from July l982 through April l986. The results include hours of operation and performance data in the form of normalized emission current density versus temperature curves (Miram plots).

Batra, R.↗

Microanalyses of extended-test xenon hollow cathodes

Four hollow cathodes have been examined using boroscopy, scanning electron microscopy, energy dispersive X-ray analysis, and X-ray diffraction analysis to characterize the life-limiting phenomena that resulted from their extended operation. The first pair of cathodes was operated for approximately 500 h in an ion thruster simulator at a 5.0 kW-equivalent power level using different cathode activation and propellant feed-system procedures. The second pair of cathodes was the main discharge cathode and neutralizer cathode from an ion thruster which have completed an 89-hour life-test at a 5.5 kW power level. The greatest change to the cathode condition was found to be removal of refractory metals, primarily tungsten, and their subsequent deposition on other cathode surfaces. Barium tungstate and barium molybdate were also found in all four cathodes. Criteria for improved cathode longevity and discharge operation are proposed for use in hollow cathode and full thruster testing facilities.

Verhey, Timothy R.↗

Extended testing of xenon ion thruster hollow cathodes

A hollow cathode wear-test of 508 hours was successfully completed at an emission current of 23.0 A and a xenon flow rate of 10 Pa-L/s. This test was the continuation of a hollow cathode contamination investigation. Discharge voltage was stable at 16.7 V. The cathode temperature averaged 1050 C with a 7 percent drop during the wear-test. Discharge ignition voltage was found to be approximately 20 V and was repeatable over four starts. Post-test analyses of the hollow cathode found a much improved internal cathode condition with respect to earlier wear-test cathodes. Negligible tungsten movement occurred and no formation of mono-barium tungstate was observed. These results correlated with an order-of-magnitude reduction in propellant feed-system leakage rate. Ba2CaWO6 and extensive calcium crystal formation occurred on the upstream end of the insert. Ba-Ca compound depositions were found on the Mo insert collar, on the Re electrical leads, and in the gap between the insert and cathode wall. This wear-test cathode was found to be in the best internal condition and had the most stable operating performance of any hollow cathode tested during this contamination investigation.

Sarver-Verhey, Timothy R.↗

Work Functions for Models of Scandate Surfaces

The electronic structure, surface dipole properties, and work functions of scandate surfaces have been investigated using the fully relativistic scattered-wave cluster approach. Three different types of model surfaces are considered: (1) a monolayer of Ba-Sc-O on W(100), (2) Ba or BaO adsorbed on Sc2O3 + W, and (3) BaO on SC2O3 + WO3. Changes in the work function due to Ba or BaO adsorption on the different surfaces are calculated by employing the depolarization model of interacting surface dipoles. The largest work function change and the lowest work function of 1.54 eV are obtained for Ba adsorbed on the Sc-O monolayer on W(100). The adsorption of Ba on Sc2O3 + W does not lead to a low work function, but the adsorption of BaO results in a work function of about 1.6-1.9 eV. BaO adsorbed on Sc2O3 + WO3, or scandium tungstates, may also lead to low work functions.

Mueller, Wolfgang↗

Destructive Evaluation of a Xenon Hollow Cathode after a 28,000 Hour Life Test

International Space Station (ISS) plasma contactor system requires a hollow cathode assembly (HCA) with a lifetime of at least 18,000 hours. In order to demonstrate the lifetime capability of the HCA, a series of hollow cathode wear tests was performed which included a life test operated at the maximum current of the HCA. This test sought to verify hollow cathode lifetime capability and contamination control protocols. This hollow cathode accumulated 27,800 hours of operation before it failed during a restart attempt. The cathode was subsequently destructively analyzed in order to determine the failure mechanism. Microscopic examination of the cathode interior determined that relatively small changes in the cathode physical geometry had occurred and barium tungstates, which are known to limit the emission process, had formed over a majority of the electron emitter surface. Because the final state of the insert was consistent with expected impregnate chemistry, the hollow cathode was believed to have reached the end of its usable life under the test conditions.

Sarver-Verhey, Timothy R.↗

Design and Performance Tests of Ultra-Compact Calorimeters for High Energy Astrophysics

This R&D project had two goals: a) the study of general-application ultra-compact calorimetry technologies for use in High Energy Astrophysics and, b) contribute to the design of an efficient calorimeter for the ACCESS mission. The direct measurement of galactic cosmic ray fluxes is performed from space or from balloon-borne detectors. Detectors used in those studies are limited in size and, specially, in weight. Since galactic cosmic ray fluxes are very small, detectors with high geometrical acceptances and long exposures are usually required for collecting enough statistics. We have studied calorimeter techniques that could produce large geometrical acceptance per unit of mass (G/w) and that may be used to study galactic cosmic rays at intermediate energies (knee energies).-The most important asset for detection of primary cosmic rays at and about the knee is large acceptance. To construct a large acceptance calorimeter (this term is used here in its most general accepted meaning of calorimeter as a device to measure particle energies ) the detector needs to be verv liaht or verv shallow . We studied two possible technologies to built compact calorimeters: the use of lead-tungstate crystals (PWO) and the use of sampling calorimetry using scintillating fibers embedded in a matrix of powder tungsten. For a very light detector, we considered the possibility of using Optical Transition Radiation (OTR) to measure the energy (and perhaps also direction and identity) of VHE cosmic rays.

Salgado, Carlos W.↗

Comparative induction of nitrate reductase by nitrate and nitrite in barley leaves

The comparative induction of nitrate reductase (NR) by ambient NO3- and NO2- as a function of influx, reduction (as NR was induced) and accumulation in detached leaves of 8-day-old barley (Hordeum vulgare L.) seedlings was determined. The dynamic interaction of NO3- influx, reduction and accumulation on NR induction was shown. The activity of NR, as it was induced, influenced its further induction by affecting the internal concentration of NO3-. As the ambient concentration of NO3- increased, the relative influences imposed by influx and reduction on NO3- accumulation changed with influx becoming a more predominant regulant. Significant levels of NO3- accumulated in NO2(-)-fed leaves. When the leaves were supplied cycloheximide or tungstate along with NO2-, about 60% more NO3- accumulated in the leaves than in the absence of the inhibitors. In NO3(-)-supplied leaves NR induction was observed at an ambient concentration of as low as 0.02 mM. No NR induction occurred in leaves supplied with NO2- until the ambient NO2- concentration was 0.5 mM. In fact, NR induction from NO2- solutions was not seen until NO3- was detected in the leaves. The amount of NO3- accumulating in NO2(-)-fed leaves induced similar levels of NR as did equivalent amounts of NO3- accumulating from NO3(-)-fed leaves. In all cases the internal concentration of NO3-, but not NO2-, was highly correlated with the amount of NR induced. The evidence indicated that NO3- was a more likely inducer of NR than was NO2-.

NASA Program CELSS↗

Radionuclide incorporation in negative thermal expansion α-Zr(WO 4 ) 2 : A density functional theory study

The incorporation of uranium, plutonium and technetium in the negative thermal expansion (NTE) α-Zr (WO 4 ) 2 has been investigated within the framework of density functional theory (DFT). It is found that the vacancy formation energies of the charged vacancies are overall larger than that of its counterpart neutral Frenkel defects and Schottky defects. DFT calculations suggest that U and Pu substitutions for the Zr site are preferred in α-Zr (WO 4 ) 2 . In case of Tc substitution, both Tc(IV) for the Zr site and Tc(VII) for the W site are considered under oxygen-poor and oxygen-rich conditions, while Tc(VII) substitution can be improved significantly by including Y 2 O 3 (charge compensation).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗