Search NASA⌕ Search

SEARCH · Search NASA

Results for “ULTRAFILTRATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

EFRT M-12 Issue Resolution: Solids Washing

Pacific Northwest National Laboratory (PNNL) has been tasked by Bechtel National Inc. (BNI) on the River Protection Project-Hanford Tank Waste Treatment and Immobilization Plant (RPP-WTP) project to perform research and development activities to resolve technical issues identified for the Pretreatment Facility (PTF). The Pretreatment Engineering Platform (PEP) was designed, constructed, and operated as part of a plan to respond to issue M12, “Undemonstrated Leaching Processes.” The PEP is a 1/4.5-scale test platform designed to simulate the WTP pretreatment caustic leaching, oxidative leaching, ultrafiltration solids concentration, and slurry washing processes. The PEP replicates the WTP leaching processes using prototypic equipment and control strategies. Two operating scenarios were evaluated for the ultrafiltration process (UFP) and leaching operations. The first scenario has caustic leaching performed in the UFP-VSL-T01A/B ultrafiltration feed vessels, identified as Integrated Test A. The second scenario has caustic leaching conducted in the UFP-VSL-T02A ultrafiltration feed preparation vessel, identified as Integrated Test B. Washing operations in PEP Integrated Tests A and B were conducted successfully as per the approved run sheets. However, various minor instrumental problems occurred, and some of the process conditions specified in the run sheet were not met during the wash operations, such as filter-loop flow-rate targets not being met. Five analytes were selected based on full solubility and monitored in the post-caustic-leach wash as successful indicators of washing efficiency. These were aluminum, sulfate, nitrate, nitrite, and free hydroxide. Other analytes, including sodium, oxalate, phosphate, and total dissolved solids, showed indications of changing solubility; therefore, they were unsuitable for monitoring washing efficiency. In the post-oxidative-leach wash, two analytes with full solubility were selected as suitable indicators of washing efficiency. These were chromium and oxalate. Other analytes, including sodium, manganese, nitrate, and total dissolved solids, showed indications of changing solubility; therefore, they were unsuitable for monitoring washing efficiency. An overall wash efficiency of 1.00 ± 0.01 was determined for the post-caustic-leach wash. The overall wash efficiency for the post-oxidative-leach wash was determined also to be 0.99 ± 0.01. These wash efficiencies were based on the weighted least squares fit of the full data set for each applicable analyte and are an average of several analytes traced during the washing steps in Integrated Tests A and B. Incremental wash efficiencies as a function of wash step were also given to provide an indication of the variability during the washing process. Chemical tracer tests resulted in the major conclusion that nearly complete mixing was achieved between 2 and 4 minutes after tracer injection. With inconsistent filter-loop flow rates and other mixing parameters, future process conditions should be taken into account during further interpretation of these data. A slight decrease of 8 to 10% in the tracer concentration between 4 and 60 minutes suggests that there was a relatively small unmixed region that mixed over the course of the 1-hour test. The IW batch time interval, defined as the duration between the start of the IW wash injection for a batch to the start for the IW wash injection for the subsequent batch, was often close to or less than the required 4-minute mixing time indicated by the tracer tests. Such short batch durations did not appear to have significantly impacted the washing efficiencies.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Laboratory Tests on Post-Filtration Precipitation in the WTP Pretreatment Process

Pacific Northwest National Laboratory (PNNL) has been tasked by Bechtel National Inc. (BNI) on the River Protection Project-Hanford Tank Waste Treatment and Immobilization Plant (RPP-WTP) project to perform research and development activities to resolve technical issues identified for the Pretreatment Facility (PTF). The Pretreatment Engineering Platform (PEP) was designed, constructed, and operated as part of a plan to respond to issue M12, "Undemonstrated Leaching Processes," of the External Flowsheet Review Team (EFRT) issue response plan (Barnes et al. 2006). The PEP is a 1/4.5-scale test platform designed to simulate the WTP pretreatment caustic leaching, oxidative leaching, ultrafiltration solids concentration, and slurry washing processes. The PEP replicates the WTP leaching processes using prototypic equipment and control strategies. A simplified flow diagram of the PEP system is shown in Figure 1.1. Two operating scenarios are currently being evaluated for the ultrafiltration process (UFP) and leaching operations. The first scenario has caustic leaching performed in the UFP-2 ultrafiltration feed vessels (i.e., vessel UFP-VSL-T02A in the PEP; and vessels UFP-VSL-00002A and B in the WTP PTF). The second scenario has caustic leaching conducted in the UFP-1 ultrafiltration feed preparation vessels (i.e., vessels UFP-VSL-T01A and B in the PEP; vessels UFP-VSL-00001A and B in the WTP PTF).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

PEP Integrated Test D Run Report Caustic and Oxidative Leaching in UFP-VSL-T02A

Pacific Northwest National Laboratory (PNNL) has been tasked by Bechtel National Inc. (BNI) on the River Protection Project-Hanford Tank Waste Treatment and Immobilization Plant (RPP-WTP) project to perform research and development activities to resolve technical issues identified for the Pretreatment Facility (PTF). The Pretreatment Engineering Platform (PEP) was designed, constructed and operated as part of a plan to respond to issue M12, "Undemonstrated Leaching Processes" of the External Flowsheet Review Team (EFRT) issue response plan. The PEP is a 1/4.5-scale test platform designed to simulate the WTP pretreatment caustic leaching, oxidative leaching, ultrafiltration solids concentration, and slurry washing processes. The PEP replicates the WTP leaching processes using prototypic equipment and control strategies. The PEP also includes non-prototypic ancillary equipment to support the core processing. Two operating scenarios are currently being evaluated for the ultrafiltration process (UFP) and leaching operations. The first scenario (Test B and D) has caustic leaching performed in the UFP-2 ultrafiltration feed vessels (i.e., vessel UFP-VSL-T02A in the PEP and vessels UFP-VSL-00002A and B in the WTP PTF). The second scenario (Test A) has caustic leaching conducted in the UFP-1 ultrafiltration feed preparation vessels (i.e., vessels UFP-VSL-T01A and B in the PEP and vessels UFP VSL-00001A and B in the WTP PTF). In Test D, 19M sodium hydroxide (NaOH, caustic) was added to the waste slurry in the UFP VSL T02 vessel after the solids were concentrated to ~20% undissolved solids. The NaOH was added to leach solid aluminum compounds (e.g., gibbsite, boehmite). Caustic addition is followed by heating to 85°C using direct injection of steam to accelerate the leach process. The main difference of Test D compared to Test B is that the leach temperature is 85°C for 24 hrs as compared to 100°C for 12 hours. The other difference is the Test D simulant had Cr in the simulant from the start of processing and Test B had Cr added to adjust the simulant composition after aluminum leaching. Following the caustic leach, the UFP-VSL-T02A vessel contents are cooled using the vessel cooling jacket. The slurry was then concentrated to 17 wt% undissolved solids and washed with inhibited water to remove NaOH and other soluble salts. Next, the slurry was oxidatively leached using sodium permanganate to solubilize chrome. The slurry was then washed to remove the dissolved chrome and concentrated.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

NMR-based metabolite profiling of human milk: A pilot study of methods for investigating compositional changes during lactation

Low-molecular-weight metabolites in human milk are gaining increasing interest in studies of infant nutrition. In the present study, the milk metabolome from a single mother was explored at different stages of lactation. Metabolites were extracted from sample aliquots using either methanol/water (MeOH/H{sub 2}O) extraction or ultrafiltration. Nuclear magnetic resonance (NMR) spectroscopy was used for metabolite identification and quantification, and multi- and univariate statistical data analyses were used to detect changes over time of lactation. Compared to MeOH/H{sub 2}O extraction, ultrafiltration more efficiently reduced the interference from lipid and protein resonances, thereby enabling the identification and quantification of 36 metabolites. The human milk metabolomes at the early (9–24 days after delivery) and late (31–87 days after delivery) stages of lactation were distinctly different according to multi- and univariate statistics. The late lactation stage was characterized by significantly elevated concentrations of lactose, choline, alanine, glutamate, and glutamine, as well as by reduced levels of citrate, phosphocholine, glycerophosphocholine, and N-acetylglucosamine. Our results indicate that there are significant compositional changes of the human milk metabolome also in different phases of the matured lactation stage. These findings complement temporal studies on the colostrum and transitional metabolome in providing a better understanding of the nutritional variations received by an infant. - Highlights: • 36 metabolites were simultaneously quantified in human milk by NMR. • Ultrafiltration more efficiently reduces interferences than MeOH/H{sub 2}O extraction. • Compositional changes of the human milk exist during the matured lactation stage.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The role of natural purified humic acids in modifying mercury accessibility in water and soil

We investigated the influence of different humic acids (HAs, extracted from lignite, compost, and forest soil) on mercury mobility and availability both in a model solution and in soil samples from a mercury-polluted region. The technique of diffusive gradients in thin-films (DGT), which is capable of measuring: (i) free metal in solution: (ii) dissociated metal complexes previously mobilized by HA; (iii) mobilized metal-HA complexes that liberate metals by dissociation or by exchange reaction between the metal-HA complexes and the chelating groups on the resin-gel, was used in solutions and soils. The DGT measurements in solution, together with ultrafiltration, allowed estimation of the lability of Hg-HA complexes. Ultrafiltration results were also compared with predictions made by the windermere humic-aqueous model (WHAM). According to both these different approaches, Hg{sup 2+} resulted nearly 100% complexed by HAs, whereas results from ultrafiltration showed that 32 to 72% of the CH{sub 4}Hg{sup +} was bound to the HAs, with higher values for compost and lower values for forest and Aldrich HA. The DGT-measured mercury in soils was below 0.20 {mu}g L{sup -1}, irrespective of the extent of the contamination. Addition of HA increased the concentration of DGT-measured mercury in soil solution up to 100-fold in the contaminated soil and up to 30-fold in the control soil. The level of the increase also depended on the HA. The smallest increase (about 10 times) was found for lignite HA in both control and contaminated soils. The addition of forest HA gave the largest increases in DGT-measured mercury, in particular for the contaminated soil. Overall, the results demonstrated that DGT can be used for estimating the lability of mercury complexes in solution and for verifying enhanced mercury mobility when HA is added to contaminated soils.

01 COAL, LIGNITE, AND PEAT↗

Networks that link cytoskeletal regulators and diaphragm proteins underpin filtration function in Drosophila nephrocytes

Highlights: • Drosophila nephrocytes have a unique cytoplasmic cluster of F-actin. • Microtubules, Rho-GTPases and endoplasmic reticulum position the actin cluster. • Nephrocyte diaphragm proteins localize to and regulate actin cluster organization. • Perturbation of any of these inter-dependent components impairs ultrafiltration. Insect nephrocytes provide a valuable model for kidney disease, as they are structurally and functionally homologous to mammalian kidney podocytes. They possess an exceptional macromolecular assembly, the nephrocyte diaphragm (ND), which serves as a filtration barrier and helps maintain tissue homeostasis by filtering out wastes and toxic products. However, the elements that maintain nephrocyte architecture and the ND are not understood. We show that Drosophila nephrocytes have a unique cytoplasmic cluster of F-actin, which is maintained by the microtubule cytoskeleton and Rho-GTPases. A balance of Rac1 and Cdc42 activity as well as proper microtubule organization and endoplasmic reticulum structure, are required to position the actin cluster. Further, ND proteins Sns and Duf also localize to this cluster and regulate organization of the actin and microtubule cytoskeleton. Perturbation of any of these inter-dependent components impairs nephrocyte ultrafiltration. Thus cytoskeletal components, Rho-GTPases and ND proteins work in concert to maintain the specialized nephrocyte architecture and function.

60 APPLIED LIFE SCIENCES↗

Emerging technologies and approaches to minimize discharges into Lake Michigan, phase 2 module 4 report.

The Great Lakes Initiative (GLI) established the new water quality-based discharge criteria for mercury (Hg), thereby increasing the need for many municipal and industrial wastewater treatment plants in the region to lower the mercury in their effluents. Information on deployable technologies to satisfy these requirements for industrial and municipal dischargers in the Great lakes region is scarce. Therefore, BP funded Purdue University Calumet and Argonne to identify deployable Hg removal technologies to meet the GLI discharge criterion at its Whiting Refinery in Indiana. The joint PUC/Argonne project was divided into 2 phases. Results from Phase I and Phase II Modules 1-3 have been previously reported. This report summarizes the work done in Phase 3 Module 4, which consisted of the pilot scale testing of Hg removal technologies previously selected in Module 3. The pilot testing was an Argonne/PUC jointly directed project that was hosted at and funded by the BP refinery in Whiting, IN. As two organizations were involved in data analysis and interpretation, this report combines two independent sets of evaluations of the testing that was done, prepared respectively by Argonne and Purdue. Each organization retains sole responsibility for its respective analysis conclusions and recommendations. Based on Module 3 bench testing with pre-Effluent To Lake (pre-ETL) and clarifier effluent (CE) samples from the Whiting refinery, three different technologies were chosen for pilot testing: (1) Ultrafiltration (using GE ZeeWeed(reg sign) Technology, 0.04 {mu}m pore size and made up of PVDF) for particulate mercury removal; (2) Adsorption using Mersorb(reg sign) LW, a sulfur-impregnated activated carbon, for dissolved mercury removal if present and (3) The Blue PRO(reg sign) reactive filtration process for both particulate and dissolved (if present) mercury removal. The ultrafiltration and the Blue PRO(reg sign) reactive filtration pilot studies were done simultaneously at the BP Whiting refinery using a slipstream of wastewater taken just prior to the Effluent to lake (pre-ETL) outfall. It was the intention of this pilot testing to demonstrate proof of concept, i.e. can the discharge limits obtained at bench scale be consistently met at the pilot scale. Although Mersorb(reg sign) LW was selected for dissolved mercury removal testing, this technology was not pilot tested because of a lack of dissolved mercury in the test wastewater during the pilot study. The overall objective of this pilot testing was to demonstrate the effectiveness of the tested technologies with continuous and varying feed conditions to meet the GLI criterion (1.3 ppt). Optimization for full-scale design was outside of the scope of this work. In addition to demonstrating whether the Hg criterion can be met, information on residue generation rate, frequency of backwashing and other maintenance issues were collected to better understand the implications for a full-scale system.

54 ENVIRONMENTAL SCIENCES↗

Pretreatment Engineering Platform Phase 1 Final Test Report

Pacific Northwest National Laboratory (PNNL) was tasked by Bechtel National Inc. (BNI) on the River Protection Project, Hanford Tank Waste Treatment and Immobilization Plant (RPP-WTP) project to conduct testing to demonstrate the performance of the WTP Pretreatment Facility (PTF) leaching and ultrafiltration processes at an engineering-scale. In addition to the demonstration, the testing was to address specific technical issues identified in Issue Response Plan for Implementation of External Flowsheet Review Team (EFRT) Recommendations - M12, Undemonstrated Leaching Processes.( ) Testing was conducted in a 1/4.5-scale mock-up of the PTF ultrafiltration system, the Pretreatment Engineering Platform (PEP). Parallel laboratory testing was conducted in various PNNL laboratories to allow direct comparison of process performance at an engineering-scale and a laboratory-scale. This report presents and discusses the results of those tests.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Process Testing Results and Scaling for the Hanford Waste Treatment and Immobilization Plant (WTP) Pretreatment Engineering Platform - 10173

The U.S. Department of Energy-Office of River Protection’s Hanford Tank Waste Treatment and Immobilization Plant (WTP) is being designed and built to pretreat and then vitrify a large portion of the wastes in Hanford’s 177 underground waste storage tanks at Richland, Washington. In support of this effort, engineering-scale tests at the Pretreatment Engineering Platform (PEP) have been completed to confirm the process design and provide improved projections of system capacity. The PEP is a 1/4.5-scale facility designed, constructed, and operated to test the integrated leaching and ultrafiltration processes being deployed at the WTP. The PEP replicates the WTP leaching processes with prototypic equipment and control strategies and non-prototypic ancillary equipment to support the core processing. The testing approach used a nonradioactive aqueous slurry simulant to demonstrate the unit operations of caustic and oxidative leaching, cross-flow ultrafiltration solids concentration, and solids washing. Parallel tests conducted at the laboratory scale with identical simulants provided results that allow scale-up factors to be developed between the laboratory and PEP performance. This paper presents the scale-up factors determined between the laboratory and engineering-scale results and presents arguments that extend these results to the full-scale process.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Modeling of Leaching Filter Pressure Drop and Fouling Behavior

A new simulation capability has been developed for modeling the flow and thermal performance of chemical processes that involve multiphase, chemically-complex flows. This capability is applied to the ultrafiltration process which will be used in conjunction with caustic and/or oxidative leaching to concentrate high level waste in the Waste Treatment and Immobilization Plant (WTP) at the US DOE Hanford site. The separation of supernatant from undissolved solids is an important aspect of these processes. The design and likely operational performance of the proposed ultrafiltration system for the WTP facility have been called into question by external reviewers. Lattice methods are used to model both the pore scale filtration mechanisms in the filter material and the filter device scale performance. Simulation results are compared with data from experiments.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Technology for Treatment of Liquid Radioactive Waste Generated during Uranium and Plutonium Chemical and Metallurgical Manufacturing in FSUE PO Mayak - 13616

Created technological scheme for treatment of liquid radioactive waste generated while uranium and plutonium chemical and metallurgical manufacturing consists of: - Liquid radioactive waste (LRW) purification from radionuclides and its transfer into category of manufacturing waste; - Concentration of suspensions containing alpha-nuclides and their further conversion to safe dry state (calcinate) and moving to long controlled storage. The following technologies are implemented in LRW treatment complex: - Settling and filtering technology for treatment of liquid intermediate-level waste (ILW) with volume about 1500m{sup 3}/year and alpha-activity from 10{sup 6} to 10{sup 8} Bq/dm{sup 3} - Membrane and sorption technology for processing of low-level waste (LLW) of radioactive drain waters with volume about 150 000 m{sup 3}/year and alpha-activity from 10{sup 3} to 10{sup 4} Bq/dm{sup 3}. Settling and filtering technology includes two stages of ILW immobilization accompanied with primary settling of radionuclides on transition metal hydroxides with the following flushing and drying of the pulp generated; secondary deep after settling of radionuclides on transition metal hydroxides with the following solid phase concentration by the method of tangential flow ultrafiltration. Besides, the installation capacity on permeate is not less than 3 m{sup 3}/h. Concentrates generated are sent to calcination on microwave drying (MW drying) unit. Membrane and sorption technology includes processing of averaged sewage flux by the method of tangential flow ultrafiltration with total capacity of installations on permeate not less than 18 m{sup 3}/h and sorption extraction of uranium from permeate on anionite. According to radionuclide contamination level purified solution refers to general industrial waste. Concentrates generated during suspension filtering are evaporated in rotary film evaporator (RFE) in order to remove excess water, thereafter they are dried on infrared heating facility. Solid concentrate produced is sent for long controlled storage. Complex of the procedures carried out makes it possible to solve problems on treatment of LRW generated while uranium and plutonium chemical and metallurgical manufacturing in Federal State Unitary Enterprise (FSUE) Mayak and cease its discharge into open water reservoirs. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Conservation and Recycling for Radiological-Contaminated Laundry Applications - 16044

Recovery and reuse of materials exposed to radioactive environments is a critical element for those whom are involved with processing such materials. In order to minimize the disposal of radiological-contaminated Personal Protective Equipment (PPE, laundry, respirators, etc.) the need for environmentally-friendly and cost-effective technologies to provide laundering services is needed for current and future processes. A by-product of the laundry process is contaminated water. In order to reduce waste generation, we developed a radiological water filtration system custom-designed for laundry applications, which is used as both a filtration device as well as a water recycling system. The filtration process utilizes membrane filtration, suspended solids and organic filtration, ion-exchange capture, and ozonization/UV as germicidal reducers. In addition, ultrafiltration is used as a final step in order to return clean water back to the washing process system. The system was originally designed for non-radiological industrial laundry applications (hospitality, health care, correctional and governmental settings, etc). This process reduces the water consumption and discharge by up to 75% while retaining heat to minimize energy input costs. Principle components of the system include lint shakers and collection tanks with ozone injection, suspended solids filter, activated charcoal, ultraviolet lamp treatment cell, ion exchange columns, ultrafiltration filters, and final holding tank with ozone injection. Although up-front equipment costs are required, we believe that the reduction in waste generated through recycle and reuse of the water, along with avoiding premature disposal of PPE as radioactive waste, greatly outweighs up-front effort. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Full-Scale Vessel Testing for the Hanford Waste Treatment and Immobilization Plant - 18333

Concerns over the mixing performance of the planned pulse jet mixed (PJM) vessels for high-solids applications in the Hanford Waste Treatment and Immobilization Plant (WTP) Pretreatment (PT) Facility, led to the development of a standard high-solids vessel (SHSV) design and full-scale vessel testing program. The SHSV is intended as a potential replacement for several high-level waste feed receipt and lag storage vessels (High-Level Waste Facility lag storage and feed blending process), ultrafiltration feed preparation vessels (ultrafiltration process system), and plant wash vessels (plant wash and disposal system). The SHSV concept uses multiple smaller vessels (60 500 L - 79 500 L nominal batch size) to replace larger vessels, providing redundancy, improved mixing (PJM design and spargers), monitoring (multi-level bubblers), reduced material at risk, and improved structural features. The SHSV also requires qualification of a single vessel design for high solids Newtonian and non-Newtonian slurry processing, rather than having to qualify earlier multiple vessel designs. An Integrated Technical Team consisting of the U.S. Department of Energy, Bechtel National, Inc., and independent experts was established to accelerate and provide oversight and direction of the test program and SHSV qualification. Qualification of the SHSV for mixing has now been achieved through a comprehensive full-scale vessel testing program conducted in 2017 with a prototypic SHSV under a set of most adverse design conditions, in conjunction with additional engineering analyses. This paper will present an overview of the SHSV, results from the three-phase full-scale vessel test and qualification program completed in September 2017, and the management program to achieve resolution of the PJM mixing technical issue. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Pretreatment Engineering Platform--Reducing Technical Risks for the Waste Treatment Plant Pretreatment Facility through Scaled Process Testing

The Hanford Waste Treatment and Immobilization Plant (WTP) will separate and vitrify (immobilize in glass) millions of gallons of radioactive and chemical wastes stored at the Hanford Site. Pretreatment of the waste by caustic and oxidative leaching processes will minimize the volume of high-level waste (HLW) to be vitrified, and cross-flow ultrafiltration will be used to remove liquids from the HLW solid slurry. An extensive and critical review of the WTP technical bases and design identified the need to demonstrate of the integrated leaching and ultrafiltration processes at greater than bench scale. To respond to this need, the WTP prime contractor, Bechtel National, Inc., and their principle subcontractor Washington Group International concluded a 1/4.5 scale facility to treat non-radioactive waste simulants was needed to demonstrate the process. This paper describes the technical bases and design of the scaled Pretreatment Engineering Platform (PEP) and the strategy to develop waste simulants to be used in the PEP

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Photocatalytic Nanofiltration Membranes with Self‐Cleaning Property for Wastewater Treatment

Membrane fouling is one of the most severe problems restricting membrane separation technology for wastewater treatment. This work reports a photocatalytic nanofiltration membrane (NFM) with self‐cleaning property fabricated using a facile biomimetic mineralization process. In this strategy, a polydopamine (PDA)/polyethyleneimine (PEI) intermediate layer is fabricated on an ultrafiltration membrane via a co‐deposition method followed by mineralization of a photocatalytic layer consisting of β‐FeOOH nanorods. The PDA–PEI layer acts both as a nanofiltration selective layer and an intermediate layer for anchoring the β‐FeOOH nanorods via strong coordination complexes between Fe 3+ and catechol groups. In visible light, the β‐FeOOH layer exhibits efficient photocatalytic activity for degrading dyes through the photo‐Fenton reaction in the presence of hydrogen peroxide, endowing the NFM concurrently with effective nanofiltration performance and self‐cleaning capability. Moreover, the mineralized NFMs exhibit satisfactory stability under simultaneous filtration and photocatalysis processing, showing great potential in advanced wastewater treatment.

Lv, Yan↗

Improvised Field Expedient Method for Renal Replacement Therapy in a Porcine Model of Acute Kidney Injury

ABSTRACT Objective: Dialysis patients may not have access to conventional renal replacement therapy (RRT) following disasters. We hypothesized that improvised renal replacement therapy (ImpRRT) would be comparable to continuous renal replacement therapy (CRRT) in a porcine acute kidney injury model. Methods: Following bilateral nephrectomies and 2 hours of caudal aortic occlusion, 12 pigs were randomized to 4 hours of ImpRRT or CRRT. In the ImpRRT group, blood was circulated through a dialysis filter using a rapid infuser to collect the ultrafiltrate. Improvised replacement fluid, made with stock solutions, was infused pre-pump. In the CRRT group, commercial replacement fluid was used. During RRT, animals received isotonic crystalloids and norepinephrine. Results: There were no differences in serum creatinine, calcium, magnesium, or phosphorus concentrations. While there was a difference between groups in serum potassium concentration over time ( P < 0.001), significance was lost in pairwise comparison at specific time points. Replacement fluids or ultrafiltrate flows did not differ between groups. There were no differences in lactate concentration, isotonic crystalloid requirement, or norepinephrine doses. No difference was found in electrolyte concentrations between the commercial and improvised replacement solutions. Conclusion: The ImpRRT system achieved similar performance to CRRT and may represent a potential option for temporary RRT following disasters.

Public, Environmental & Occupational Health↗

Membrane-Confined Iron Oxychloride Nanocatalysts for Highly Efficient Heterogeneous Fenton Water Treatment

Heterogeneous advanced oxidation processes (AOPs) allow for the destruction of aqueous organic pollutants via oxidation by hydroxyl radicals ( • OH). However, practical treatment scenarios suffer from the low availability of short-lived • OH in aqueous bulk, due to both mass transfer limitations and quenching by water constituents, such as natural organic matter (NOM). In this work, we overcome these challenges by loading iron oxychloride catalysts within the pores of a ceramic ultrafiltration membrane, resulting in an internal heterogeneous Fenton reaction that can degrade organics in complex water matrices with pH up to 6.2. With • OH confined inside the nanopores (~ 20 nm), this membrane reactor completely removed various organic pollutants with water fluxes of up to 100 L m –2 h –1 (equivalent to a retention time of 10 s). This membrane, with a pore size that excludes NOM (>300 kDa), selectively exposed smaller organics to •OH within the pores under confinement and showed excellent resiliency to representative water matrices (simulated surface water and sand filtration effluent samples). Moreover, the membrane exhibited sustained AOPs (>24 h) and could be regenerated for multiple cycles. Our results suggest the feasibility of exploiting ultrafiltration membrane-based AOP platforms for organic pollutant degradation in complex water scenarios.

36 MATERIALS SCIENCE↗

One-Component Nanocomposite Membranes from Polymer Grafted Cellulose Nanocrystals

Membrane filtration is an important industrial purification process used to access clean and potable water. The fabrication of the membranes used in these purification applications often involves expensive and energy-intensive processes that have a large negative impact on the environment. Sustainable alternatives with a high water flux and strong rejection performance are needed to purify water. Here, the focus of this work is to investigate the use of polymer-grafted cellulose nanocrystals (CNCs) in membrane applications. The impact of the polymer grafting density and polymer conformation was investigated and it is shown that by increasing the grafting density of PEG such that it adopts a semidilute polymer brush conformation, the water flux through the membranes could be increased from 3.5 to 2900 L h –1 m –2 for CNC membranes without and with grafted PEG, respectively. These membranes also exhibited rejection performances with molecular weight cutoffs between 62 and 100 kDa for all polymer-grafted samples, consistent with the ultrafiltration regime. Thus, the design of these one-component composite materials can enhance the water permeability of ultrafiltration membranes while maintaining effective selectivity.

cellulose nanocrystals↗