Search NASA⌕ Search

SEARCH · Search NASA

Results for “Voltage Trade”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

70 records · Page 4

Cathode Side-emission Mitigation for Linear Induction Accelerators

Linear induction accelerators (LIAs) are one of the main technologies used in creating flash x-rays used for diagnosing hydrodynamic experiments. The quality of the data produced in these experiments is dependent on the dose of x-rays generated via bremsstrahlung radiation. There are several electron beam quantities that effect the amount of dose extracted from the bremsstrahlung radiation, such as beam instabilities, corkscrew motion, and beam emittance. Injector design is key in delivering well-behaved electron beams to the accelerator, and design choices include components such as anode-cathode (AK) gap dimensions based on required voltage and current, shroud shaping, and cathode type and composition. Thermionic cathodes have shown reliable performance in electron emission, however, if enough of the cathode side is subject to high-enough electric field values, electrons can be emitted. This issue is more likely to happen when the cathode is treated with materials that have lower work functions, which is common for cathodes used in LIAs. These extra electrons can work their way through the rest of the beam, inducing high non-linearities in phase space which can increase the emittance of this beam. In this paper we outline conducted trade-space studies where we examined different shaping parameters of the cathode shroud design to decrease the effect side electrons may have on the beam emittance. Particle trajectories are determined by electric potential contours across the face of the cathode shroud component, and so we hypothesize that the proper shaping of the cathode-shroud interface can tune the electric field to mitigate the effect of side electrons. Electron beam transport is simulated down the length of the injector and the beam quality is diagnosed by studying the emittance as a function of position. Acceptable emittance increase is recorded and noted to meet radiographic requirements.

42 ENGINEERING↗

Nanophotonic waveguide chip-to-world beam scanning

A seamless chip-to-world photonic interface enables broad advancements in optical ranging, display, communication, computation and quantum information science. The ideal solution enables two-dimensional scanning of a diffraction-limited beam from anywhere on a photonic integrated circuit to a large number of resolvable spots. Current beam-scanning technologies are limited by a fundamental trade-off: photonic-integrated-circuits with diffractive optics offer scalability but have poor mode quality, whereas inertially limited micromechanical scanners provide high-quality beams but lack scalable integration. Here we report a photonic ski-jump—a nanoscale waveguide monolithically integrated on a piezoelectric cantilever—to overcome these limitations. It passively curls ~90° out-of-plane within a less-than-0.1 mm 2 footprint, emits a submicrometre, broadband diffraction-limited beam, and exhibits kilohertz-rate mechanical resonances with quality factors of over 10,000. Fabricated in a volume complementary metal–oxide–semiconductor (CMOS) foundry, our device enables scalable two-dimensional beam scanning. Driven on-resonance at CMOS-level voltages, it achieves a footprint-adjusted spot rate of 68.6 mega spots s –1 mm–², exceeding state-of-the-art micro-electro-mechanical systems mirrors by more than 50-fold, which is sufficient for one million pixels at 100 Hz from an approximately 1.5 mm diameter footprint. We demonstrate full-colour image and video projection, and single-photon initialization and readout from silicon vacancy centres in diamond. Finally, by demonstrating uniformity across a 64 ski-jump array, we establish a pathway to achieving greater than one gigaspot resolution at kilohertz rates within a sub-5-cm-diameter footprint, creating a seamless optical pipeline between integrated photonic processors and the free-space world.

Displays↗

Exploring the Frontiers of Energy Efficiency using Power Management at System Scale

In the face of surging power demands for exascale HPC systems, this work tackles the critical challenge of understanding the impact of software-driven power management techniques like Dynamic Voltage and Frequency Scaling (DVFS) and Power Capping. These techniques have been actively developed over the past few decades. By combining insights from GPU benchmarking to understand application power profiles, we present a telemetry data-driven approach for deriving energy savings projections. This approach has been demonstrably applied to the Frontier supercomputer at scale. Our findings based on three months of telemetry data indicate that, for certain resource-constrained jobs, significant energy savings (up to 8.5%) can be achieved without compromising performance. This translates to a substantial cost reduction, equivalent to 1438 MWh of energy saved. The key contribution of this work lies in the methodology for establishing an upper limit for these best-case scenarios and its successful application. This work enables HPC professionals to optimize the power-performance trade-off within constrained power budgets, not only for the exascale era but also beyond.

Karimi, Ahmad Maroof↗

Surface Engineering Strategy to Synthesize Bicomponent Carbons for Rechargeable Zinc-Air Batteries

Atomic Fe-N x moieties and nanosized FeCo species anchored on carbons have each been demonstrated to be among the most effective active components for oxygen reduction and evolution reactions (ORR/OER), respectively in rechargeable zinc -air batteries (ZABs). However, incorporating both of these components in a single catalyst presents a great challenge due to the trade-off in formation between them during hightemperature preparation. Herein, we integrate them into a bicomponent carbon through a surface engineering strategy. In this process, K 3 [Fe(CN) 6 ] is engineered on the surface of a precursor mixture consisting of polyaniline-coated graphene oxide and ZIF-67. This is followed by pyrolysis to produce the bicomponent carbon catalyst of FeCo nanoparticles modified carbon polyhedron (for accelerating the OER), supported on atomically dispersed Fe -N -doped carbon nanosheet (for boosting the ORR). The catalyst exhibits a small potential gap of 0.69 V for OER/ORR. In situ Raman spectroscopy demonstrates that spinel FeCo oxides may be responsible for OER. The use of this catalyst in ZABs achieves high power densities of 225 mW cm -2 in aqueous electrolyte and 164 mW cm -2 in solid-state electrolyte. Additionally, a small and stable voltage gap of 0.712 V at 10 mA cm -2 is maintained after 1035 discharge -charge cycles demonstrating the great application potential in energy devices.

An, Jia-Xing↗

Scalability and Effectiveness of Smart Charge Management

The rise in electric vehicle (EV) adoption presents growing challenges for power grids, particularly from simultaneous residential charging, which can cause voltage fluctuations and increase feeder peak loads. Baltimore Gas and Electric (BGE), with support from the U.S. Department of Energy, initiated a pilot program to evaluate managed residential EV charging through Smart Charge Management (SCM). This study analyzes real-world charging behavior data from the pilot and feeder-level base loads from BGE to simulate residential charging scenarios through 2035 across the Washington, DC–Baltimore region. Grid impacts under unmanaged charging are compared to three SCM strategies: TOU-immediate, TOU-distributed, and Load Balancing. Results show that the magnitude of peak reduction is highly feeder-dependent. Some feeders achieve reductions of more than 40% at high enrollment levels, while others show improvements closer to 10–15%. This heterogeneity reflects differences in baseline feeder load shapes, EV penetration, and plug-in behavior across customers. Results also highlight trade-offs between shifting load away from peak periods and minimizing secondary demand peaks, offering practical insights for future utility program design.

Electric vehicle↗

Vacuum Insulator Flashover Physics LDRD Report

Large, pulsed power and high voltage systems often employ a stack of insulators to separate a vacuum section away from water or oil sections. The size of this insulator stack often drives overall costs and feasibility of these systems. An electric breakdown along the insulator surface is a primary failure mechanism and is especially impactful if it occurs while power is still being delivered downstream. This report describes a set of experimental and modeling investigations into the cause of these breakdowns, especially focusing on the much less well-understood anode-initiated breakdowns that occur during early parts of power delivery. Additionally, new diagnostics for assessing relevant material properties and behavior of insulators are described. These results describe breakdown behavior and evolution at new temporal and spatial fidelities and provide hypotheses and some answers as to how these breakdowns can occur. This new understanding of the roles of different physics phenomena guide modifications and trade-offs in generating newer insulator stack designs that are smaller and/or have higher electrical stress thresholds.

42 ENGINEERING↗

Hydrogen Production System Scaling Using a High-Fidelity Simulation-Optimization Framework

Proton exchange membrane (PEM) electrolyzers are widely used for hydrogen production, yet few validated, high-fidelity tools can reliably guide scale-up. Using measured performance from a 50-hour hardware-in-the-loop pilot test, a physics-based, plant-level model of a 1.25 MW PEM electrolyzer and its balance-of-plant (BoP) subsystems is developed and validated. The model couples electrochemistry and thermal/flow submodels and is calibrated against pilot test data via a genetic algorithm (GA) workflow. Validation yields a mean absolute percentage error (APE) of 0.43% for cell voltage and stack power. Two scale-out strategies are then benchmarked under a common 7-day wind-and-photovoltaic (PV) profile: (i) linear duplication of 1.25 MW blocks and (ii) shared-BoP architectures. Sharing BoP between stacks reduces BoP energy by 27% at 10 MW and 34% at 100 MW (vs. linear duplication) and improves system specific energy consumption (SEC) to 52.9 and 52.6 kWh/kg, respectively (from 54.0 kWh/kg with linear duplication). Partial-load studies (25-100% set-point) show that cumulative hydrogen production remains nearly constant down to 50% load because all cases use the same weekly renewable-energy input. Below 50%, the power cap limits how much energy can be used within 168 h, which reduces hydrogen output. The model further indicates that the practical operating optimum lies between 50% and 85% load, where efficiency gains begin to appear without significant loss in hydrogen output. Moreover, the efficiency gains at lower loads are offset by reduced production. The validated framework supports scenario-based engineering trade-off studies for large configurations (10-100 MW) and for operating policies under variable renewables.

08 HYDROGEN↗

Fairness-Aware Distributed Energy Coordination for Voltage Regulation in Power Distribution Systems

The accelerating deployment of solar photovoltaics into low-voltage distribution networks can cause reverse power flow and overvoltage problems. However, if coordinated properly, the real and reactive power flexibility of these resources enables distribution operators to manage their networks more efficiently. Existing literature is rich in droop-based control (Volt-Watt and Volt-VAr) and optimization-based distributed energy coordination for four-quadrant control of photovoltaics to prevent overvoltage issues. While optimal coordination can effectively mitigate overvoltage, it tends to treat resources at sensitive parts of the grid unfairly. Here, to address this concern, we propose a distributed optimal power flow formulation that incorporates fairness in curtailing photovoltaic generation and utilizes the reactive power capability of smart inverters. The proposed distributed formulation allows for scalable resource aggregation that can be leveraged to achieve fairness within a certain segment of the grid and/or fairness across the entire network. Fair curtailment of photovoltaic systems is demonstrated with aggregation at each of two layers in a distribution network: 1) area-level fairness and 2) feeder-level fairness. To explore the trade-off between fairness and optimal utilization, the fairness-aware control actions are compared against the performance of a centralized controller that aims to maximize the aggregate PV generation without incorporating fairness. Simulation results show that introducing area-level fairness increased curtailment by 0.0101 percentage points and feeder-level fairness increased curtailment by 0.0458 percentage points compared to a fairness-agnostic control.

Poudel, Shiva↗

Electrical Fault Detection, Power Quality, Distributed Energy Resource Use Cases, and Cyber Event Applications with the Cyber Grid Guard System Using Distributed Ledger Technology

Electrical utilities continue to deploy more intelligent electronic devices (IEDs) inside and outside electrical substation and are associated with distributed energy resources (DERs). The integrity and confidentiality of data from IEDs is crucial, and distributed ledger technology (DLT) could improve the resilience of microgrids by helping to make these data more secure. The most popular applications using blockchain technology for electrical utilities is in the field is based on energy trading. However, the dynamism of the penetration of customer owned DERs and the deployment of sensors with IEDs have led to the identification of new applications using DLT that are focused on other areas, such as monitoring, operation and management of the grid and its assets. In addition, the majority of studies on electrical grid applications with blockchain were validated with software simulations. Although general monitoring of power systems for using DLT could be evaluated in operational electric grids, other DLT research applications such as defense against cyber-attacks and/or electrical fault detection are not likely to be performed in a real infrastructure because of possible risks to the network/equipment security. This report summarizes the application of power system applications using distributed ledger technology (DLT), providing a secure DLT framework for collecting data from IEDs like power meters and protective relays inside and outside of an electrical substation and/or between two different electrical utilities. In this study, the use case scenarios were created and assessed for different power system application by using DLT. The electrical fault detection for faulted phases (1), power quality monitoring of phase voltage magnitudes, frequency levels and load power factor (2), DERs use case monitoring (3), and cyber-event applications (4) were performed in a test bed with a Cyber-Grid Guard (CGG) system using DLT. It had a real-time simulator with power meters and protective relays in-the-loop. The first section of this report presents a literature review of power system applications using blockchain at research level. The second section shows the theory and equations used on this report. The third section shows the description of the test bed, equipment, architecture, and electrical grid diagrams. The fourth section shows the experimental models and use case scenarios that were performed for the electrical fault detection, power quality, DERs use case, and cyber event applications with the CGG system using DLT. The fifth section shows the results collected from the tests based on comparing the time stamped events of the analog signals from the IEDs, DLT computer and real time simulator. The sixth section performed the discussion of the results for the use case scenarios. Finally, section seven presents the conclusions for this report were presented.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modeling Framework for Data Center

This chapter highlights the critical need for advanced modeling of data centers due to their rapidly increasing energy consumption and impact on grid reliability. Driven by the demand for AI applications, data centers are projected to consume a significant portion of US energy by 2028, putting stress on an already challenged power grid. The chapter emphasizes the importance of "fast" time-scale models to understand the dynamic interactions between data centers and the grid, especially given the rapid power fluctuations of AI workloads. It outlines a modeling framework that includes both offline and real-time EMT domain simulations, detailing the necessary representations for various components like utility interfaces, transformers, IT loads, UPS, cooling loads, Battery Energy Storage Systems (BESS), generators, protection systems, and higher-level control systems. While standard simulation tools like PSCAD offer basic models, custom development is often required to accurately capture the unique and fast-changing behaviors of modern data centers. The chapter also discusses key metrics and test cases for validating these models, focusing on transient load responses, protection relay coordination, and demand flexibility. Finally, it addresses the challenges of modeling large-scale data centers, such as computational complexity and the trade-off between model fidelity and practicality, suggesting hybrid modeling approaches as a solution. The overarching goal is to create a robust framework that helps assess data center impacts on grid stability, identify vulnerabilities, and inform the development of standards for reliable integration of these large loads into the bulk power system.

25 ENERGY STORAGE↗

Designing Hydropower Flows to Balance Energy and Environmental Needs (HydroWIRES Topic A Final Project Report)

Hydropower is expected to play a new role in the US electricity grid as more variable renewable energy sources like wind and solar come online. Wind and solar generation increase fluctuations in electrical supply increasing the value of flexible generation sources that can quickly ramp generation up and down. The flexible generation hydropower can provide as well as the ancillary services (e.g., frequency and voltage regulation and reserves, black start capability) it provides for balancing and stabilizing the power grid are predicted to be of increased value in these future grid scenarios. Yet, the flexibility of hydropower may come with environmental costs due to up- and down-ramping of hydropower plants (i.e., quickly increasing or decreasing generation flows, respectively) which may strand fish, dewater or scour fish nests, alter habitat, or create unsafe recreational conditions that may be unacceptable to participants in the hydropower regulatory process. These types of environmental impacts are often mitigated through environmental flow requirements that specify minimum or maximum flow releases, or ramp-rates changes allowed at a hydropower facility. While it is not currently known to what degree electrical grid reliability could be affected by environmental flow requirements, gaining a better understanding of these interactions before the grid becomes more deeply decarbonized can help define what policy, regulation, or infrastructure may be needed to support the clean energy transition. As the future grid will rely on hydropower to provide both flexibility and robust environmental protections, the analyses and tools described in this report are centered on making mechanistic linkages between energy and the environment in hydropower systems. This understanding of energy-environment linkages can provide the foundational understanding needed to quantitatively assess the trade-offs between the increased generation flexibility that hydropower will be expected to provide and the environmental impacts of this flexibility. This report seeks to provide an objective foundation for building future science and tools that can be used by a broad spectrum of the hydropower community that is involved in licensing or environmental regulatory proceedings tasked with balancing energy and environmental objectives through flow management.

13 HYDRO ENERGY↗

Feasibility Analyses for the Microgrid of the Mountain in the Cordillera Central Region of Puerto Rico

Distributed energy resource (DER) development can benefit communities through improvement of access to reliable electricity and a resilient energy system. Many place-specific considerations must be accounted for when designing electrical systems with co-located generation and loads. This paper presents an overview of four studies focusing on different aspects for regional DER development in the Cordillera Central region of Puerto Rico, including a grid and load stability study with the introduction of solar energy generation, microgrid design based on the solar resource in the area, resilience considerations during power outage scenarios, and qualitative risk aspects for components in the microgrid. Additionally, a conceptual substation microgrid analysis is conducted using the Microgrid Design Toolkit (MDT) to evaluate trade-offs between cost and energy availability, providing insights into optimal design strategies. A microgrid resilience assessment is performed using the Resilient Nodal Cluster Analysis Tool (ReNCAT) to identify critical loads and evaluates their accessibility during outages, emphasizing the importance of community needs. Finally, a qualitative risk assessment utilizing Hazard and Operability Analysis (HAZOP) methods highlights potential hazards and mitigations for microgrid components, ensuring robust system design and operation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Durable and High-Performance SOECs Based on Proton Conductors for Hydrogen Production

Proton-conducting solid oxide electrolysis cells (P-SOECs) are a promising technology for cost-effective and efficient production of green hydrogen. Breakthroughs in materials development, optimization of cell structure, and achievement of high performance and durability are essential to significantly increase the commercial competitiveness of these technologies. The main objective of this project is to gain scientific knowledge for the rational design, fabrication, and demonstration of a robust, highly efficient, and low-cost SOEC technology based on a proton-conducting electrolyte membrane for hydrogen production. We focused on better understanding the degradation mechanisms of proton-conducting electrolytes, air electrodes, and catalyst materials under electrolysis mode to develop an effective strategy for rationalizing new materials that are vital for enhancing cell performance and durability. The scope includes enhancing the performance and durability of the electrolyte and electrode materials under realistic operating conditions, developing highly active and robust catalysts to minimize electrode losses while improving tolerance to contaminant poisoning, revealing the mechanism of enhanced activity and stability of the catalyst, and understanding the underlying degradation mechanisms. In addition, various characterization techniques were employed to gain a fundamental understanding of the materials’ behavior and their impact on cell performance, providing vital information to guide materials discovery and cell design. After defect chemistry engineering, the optimized donor and acceptor co-doped electrolytes BaMo/W 0.03 Ce 0.71 Yb 0.26 O 3-δ (BM/W03) showed substantially improved chemical stability against high concentrations of CO 2 and H 2 O compared to the state-of-the-art electrolyte (BaZr 0.1 Ce 0.7 Y 0.1 Yb 0.1 O 3-δ , BZCYYb1711) while maintaining comparable ionic conductivity and ionic transference number. To bypass the inherent trade-off between conductivity and chemical stability, we fabricated a bi-layer electrolyte composed of BZCYYb1711 coated with a highly-stable thin layer of BaHf 0.83 Yb 0.17 O 3-δ (BHYb). This bi-layer electrolyte displayed excellent chemical stability against high concentration CO 2 ; there was no detectable formation of BaCO 3 after exposure to 97% CO 2 (with 3% H 2 O) at 500 °C for 1000 hours and the rate of degradation in resistance was about 0.4% per 1,000 hours (kh). In contrast, the same BZCYYb1711 electrolyte without a BHYb coating degraded significantly under the same testing conditions; the degradation rate was increased to 5.1%/kh. In addition, a triple conducting air electrode Ba 0.9 Pr 0.1 Hf 0.1 Y0.1Co 0.8 O 3-δ (BPHYC) was developed by heavily doping transition metal ions into a proton-conducting material. This air electrode material, composed of 3 distinct phases, exhibits superior electrocatalytic activity due to the synergistic effect from the three component phases. Moreover, an active and durable catalyst, La 2 Ni 0.5 Fe 0.5 O 4+δ (LNF), was developed, showing excellent catalytic activity and contaminant tolerance, with a degradation rate of only 0.49%/kh when exposed to high concentrations of steam and Cr. Finally, single cells were constructed from the best electrolytes, electrodes, and catalyst coatings developed in this project. These cells demonstrated superior high current density at a given cell voltage, high roundtrip efficiency, and remarkable durability (up to 1000 hours of operation).

08 HYDROGEN↗

DLMP of Competitive Markets in Active Distribution Networks: Models, Solutions, Applications, and Visions

Traditionally, the electric distribution system operates with uniform energy prices across all system nodes. However, as the adoption of distributed energy resources (DERs) propels a shift from passive to active distribution network (ADN) operation, a distribution-level electricity market has been proposed to manage new complexities efficiently. In addition, distribution locational marginal price (DLMP) has been established in the literature as the primary pricing mechanism. The DLMP inherits the LMP concept in the transmission-level wholesale market but incorporates characteristics of the distribution system, such as high $R/X$ ratios and power losses, system imbalance, and voltage regulation needs. The DLMP provides a solution that can be essential for competitive market operation in future distribution systems. This article first provides an overview of the current distribution-level market architectures and their early implementations. Next, the general clearing model, model relaxations, and DLMP formulation are comprehensively reviewed. The state-of-the-art solution methods for distribution market clearing are summarized and categorized into centralized, distributed, and decentralized methods. Then, DLMP applications for the operation and planning of DERs and distribution system operators (DSOs) are discussed in detail. Finally, visions of future research directions and possible barriers and challenges are presented.

42 ENGINEERING↗

Converter-Interfaced CHP Plant for Improved Grid-Integration, Flexibility and Resiliency

GE Research and its partner GE Renewables have proposed the use of an interface converter solution to increase the penetration of small to medium-sized CHP (1MWe to 20MWe) into distribution grids and improve their flexibility and grid support capability. Indeed, the proposed interface converter solution thanks to presence of the grid-ready inverter, allows to streamline the compliance to grid codes requirements, reduce the interconnection delays and costs and ultimately one of the main barriers for CHP adoption by commercial and industrial facilities. An additional benefit provided by the interface converter is the use of the grid-ready inverter for reactive power which eliminates the need of sizing the generator for that capability. These two benefits highly favor the economic feasibility of converter-interfaced CHP. Five user cases, each in one of the leading U.S states for CHP potential reported by the DOE in its estimation of the U.S Technical Potential of CHP, were selected to compare the economic performances of converter-interfaced CHP as compared with directly-coupled. They include a college campus in California, a hospital in New York, a water reclamation plant in Texas, a hotel in Minnesota, and a large office building in Pennsylvania. Results showed that, the presence of the interface converter allows to increase the return on investment (ROI) by 0.5 to 2 percentage points in most of the cases (4 of 5). Indeed, the interface converter by shortening the interconnection process allows to accelerate revenues while reducing interconnection costs. Added to the reduced cost of the required generator these savings trade favorably the capital cost of the converter. The analysis also showed that the profitability of the converter-interfaced CHP is highly sensitive to the energy price, interconnection delay, and converter cost. However, it appears that if the interface converter can shorten the interconnection process by at least 6 months, adopting this solution will be more economically viable than directly-coupled configuration in almost all the +23,000 sites of the U.S Technical Potential CHP. The evaluation of the benefits of a converter-interfaced CHP also showed that it enables higher ROI when coupled with other distributed energy resources (DER) such as battery energy systems (BESS) or solar photovoltaic (PV). Indeed, in those scenario, the grid-ready inverter included in the interface converter eliminates the need of separate inverters if DC-coupling is used. On the technical performance, it has been verified that the presence of the interface converter allows to reduce by 70% to 80% the CHP short-circuit contribution to grid faults. This not only reduces the mechanical and thermal stresses exposed to the CHP electrical components but also increases the grid hosting capacity which ultimately enables higher penetrations CHP. Another key benefit of the interface converter validated with hardware-in-the-loop simulations and testing is its superior capability for reactive power support. Indeed, using a power hardware testbed with two +700kW inverters configured in back-to-back, a microgrid controller and actual facilities loads it was demonstrated that the presence of the interface converter can help maintain a power factor near ~1 or regulate the voltage to ~1.0pu at the point of common coupling. This benefit can be highly valuable if in the future, due to higher penetration of renewable distributed energy resources (DER), utilities start billing demand charge based on kVA instead of kW as currently. It was also validated that converter-interfaced CHP can dispatch heat and power commands and seamlessly switch between the two modes while consistently controlling the power factor or voltage at PCC. Indeed, the power hardware testing showed that grid-connected converter-interfaced CHP can follow either the power or heat demand while maintaining a unity power factor at converter output. This research proved that the adoption of an interface converter as the solution for interconnection of CHP system into the distribution grid can greatly improve the economic feasibility of small to medium-sized CHP as well as the plant power quality, flexibility and resiliency. Additionally, it allows increased penetrations of CHP into the distribution grid, extends their grid support capability, and facilitates the integration of BESS and PV DER by streamlining their collocation within the same facilities. This ultimately provides an opportunity for commercial and small industrial facilities in the U.S to accelerate their energy transition thanks to the high energy efficiency of CHP systems and its reliable, flexible, and resilient microgrid operation when interconnected with an interface converter.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Using Membranes with Internal Microchannels to Prevent Drying-out during CO 2 Electrolysis

Scaling up CO 2 electrolysis is a vital aspect in the transition to manufacturing sustainable fuels and chemical compounds, satisfying the demand for chemicals and demand for storing renewable electricity. Depending on the employed catalyst, different products can be produced, such as carbon monoxide and ethylene, by applying a voltage on a CO 2 and H 2 O fed electrolyzer. CO is a desirable product according to techno-economic analysis, because it can be produced selectively using a silver catalyst and is a precursor for hydrocarbons in the Fischer–Tropsch process. In a state-of-the-art CO 2 electrolyzer, two electrodes are directly pressed against an ion-exchange membrane – this is called a zero-gap configuration. Therefore, the membrane is a crucial component for the system, since it has the role of providing a conductive medium between the electrodes. One of the challenges in CO 2 electrolysis is that water is consumed in the reaction. At high current density, this may cause the membrane's surface near the cathode to dry out, lowering efficiency or perhaps stopping the process entirely, since there is no longer a conductive medium. As a result, water management is critical for this process. In this work, we approach the drying-out challenge by studying the novel concept of a membrane with internal microchannels. These channels allow the circulation of water or an electrolyte inside the membrane, which reduces the water diffusion path and affects the membrane’s conductivity. The effects of channel geometry, location, and concentrations of electrolyte inside on water content, conductivity and overall performance are studied in a 2D COMSOL model. In addition, the effect of internal concentration of electrolyte on the membrane’s resistance, on the process performance and the K + cross-over to cathode side were investigated experimentally. Our modeling results prove that the presence of the channels can keep the membrane hydrated. The highest current densities are observed when the channel is closest to the cathode, and with smaller pores. Smaller pores are advantageous due to the trade-off between enhanced membrane conductivity and the lower conductivity of the liquid itself. If water is circulated in a large channel, it increases the membrane’s ionomer conductivity due to hydration but the overall conductivity is decreased since water is not highly conductive. Nonetheless, the results also show that a higher concentration of electrolyte inside the microchannels can significantly increase the total conductivity of the membrane, and therefore the energy efficiency of the process. These effects are most significant at higher current densities. In the experimental results, we’ve observed similar effects in terms of membrane conductivity and current density of the process – the higher the electrolyte concentration the higher the current density. Furthermore, a low concentration decreases the amount of potassium which crosses over to the cathode side, inhibiting salt deposition. We’ve concluded that a small channel, up to 90 µm wide, close to the pore with an electrolyte with a concentration of up to 10 mM could be very beneficial for the water management and energy efficiency of the process. This helps to keep the membrane hydrated at higher current densities, improves the conductivity of the membrane, and it doesn’t have significant impacts on the salt deposition.

Petrov, Kostadin Veselinov↗