Search NASA⌕ Search

SEARCH · Search NASA

Results for “antimonide”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

A microwave-biased millimeter- and submillimeter-wave detector using InSb.

Description of a high-purity n-type indium antimonide sample mounted in a reentrant cavity, cooled to 4.2 K, and operated as a millimeter-wave detector. The scheme utilizes a down-conversion process, and free-carrier absorption is the mechanism responsible for the detection process. Power applied at the millimeter-wave frequency causes a change in the material conductivity, which in turn causes a change in the X-band power absorption. Cavity perturbation techniques are used to analyze the scheme. The detector was operated successfully at frequencies between 35 and 150 GHz with no long-wavelength or short-wavelength cutoff observed. The scheme offers a fast, highly sensitive, and rugged detector with low conversion loss.

Eldumiati, I. I.↗

Thermal conductivity of liquid InSb and liquid Ga.

The mean thermal conductivity of liquid gallium was measured as 70 (plus or minus 7) W/m/K over the range 250-550 C. For indium antimonide, Kl = 2.04Ks at the melting temperature with Kl = 9.23 W/m/K- as a reasonable absolute value.

Seidensticker, R. G.↗

New space processing experiments for the Skylab missions.

The M512 Materials Processing Facility, which is the main item of equipment for the Skylab space manufacturing experiments is described. It is basically an electron-beam welding apparatus, consisting of a battery power supply, a 20-kV electron beam source, and a spherical 40-cm-diam vacuum chamber. It will be used to perform the M551 Metals Melting Experiment, the M552 Exothermic Brazing Experiment, the M553 Sphere Forming Experiment, the M554 Composite Casting Experiment, the M555 Gallium Arsenide Crystal Growth Experiment, the M561 Whisker-Reinforced Composites Experiment, the M562 Indium Antimonide Crystal Growth, Experiment, the M563 Mixed III-V Crystal Growth Experiment, the M564 Alkali Halide Eutectics Experiment, the M565 Silver Grids Melted in Space Experiment, and the M566 Copper-Aluminum Eutectic Experiment. Three apparatus systems designed to broaden the technical scope of the experiments and to gain experience with new experimental techniques are described. These are an electrophoretic separator, an electromagnetic levitation system, and a versatile electric furnace with an electronic control system.

Bredt, J. H.↗

Development of a long wavelength spectrometer for the 24-channel multispectral scanner: Instructions for installation, start-up, and adjustment

The basic information is presented, which is required for start-up and operation of two long-wavelength focal-plane and cooler assemblies, including the amplifiers and temperature control systems. The focal plane systems, referred to as the long wavelength spectrometer (LWS) were developed for direct replacement of Arrays 3 and 4 into the multispectral scanner presently being operated by the NASA Manned Spacecraft Center Facility, and Laboratory Support Branch. The equipment is comprised of two major sub-assemblies: Array 3 with three indium antimonide detector channels and Array 4 with seven mercury doped Germanium detector channels. Each array is mounted on a cryogenic cooler and includes the vacuum housings, mounting hardware (x, y, z translation and rotation stages) and detector signal conditioning, temperature control and monitoring electronics. The two arrays were designed to operate independently and do not share common equipment (viz power supplies, housings, mounts, etc.).

Source record↗

Skylab experiments on semiconductors and alkali halides

The space processing experiments performed during the Skylab missions included one on single crystal growth of germanium selenide and telluride, one on pure and doped germanium crystals, two on pure and doped indium antimonide, one on gallium-indium-antimony systems, and one on a sodium chloride-sodium fluoride eutectic. In each experiment, three ampoules of sample were processed in the multipurpose electric furnace within the Skylab Materials Processing Facility. All were successful in varying degrees and gave important information about crystal growth removed from the effects of earth surface gravity.

Lundquist, C. A.↗

Monotectic and syntectic alloys experiment MA-044

The flight test furnace run of the monotectic and syntectic alloys experiment was successfully performed during the Apollo Soyuz Test Project mission. All three experiment cartridges were returned intact. A second ground based test was conducted after the mission to provide one g samples with an equivalent thermal history. The examinations of all flight and ground based cartridges and ampoules have been completed. Encouraging results have been obtained in the preliminary analysis of one flight aluminum antimonide sample as compared to ground based and prototype test counterparts. In terms of reduction of the unwanted second phase, the low g sample shows a homogeneity improvement by a factor of 5 to 20. Preliminary examination of one lead zinc flight sample shows a dispersion of lead in the zinc matrix. However, complete homogenization of the material did not occur. A thermal analysis of flight data shows that the average soak temperature for the head zinc ampoules was 20 C lower than planned but 35 C above the published consolute temperature..

Ang, C. Y.↗

InSb arrays with CCD readout for 1.0- to 5.5-microns infrared applications

There were two approaches for fabricating indium antimonide (InSb) arrays with CCD readout discussed. The hybrid approach integrated InSb detectors and silicon CCDs in a modular assembly via an advanced interconnection technology. In the monolithic approach, the InSb infrared detectors and the CCD readout were integrated on the same InSb chip. Both approaches utilized intrinsic (band-to-band) photodetection with the attendant advantages over extrinsic detectors. The status of each of these detector readout concepts, with pertinent performance characteristics, was presented.

Phillips, J. D.↗

High sensitivity 1.06 micron optical receiver for precision laser range finding

Aluminum gallium antimonide avalanche photodiodes with average gain of 10, internal quantum efficiency of greater than 60%, capacitance less than 0.2pf, and dark current of less than 1 micron were designed and fabricated for use in a low noise optical receiver suitable for 2 cm accuracy rangefinding. Topics covered include: (1) design of suitable photodetector structures; (2) epitaxial growth of AlGaSb devices; (3) fabrication of photodetectors; and (4) electro-optics characterization.

Scholl, F. W.↗

Effects of systemic and non-systemic stresses on the thermal characteristics of corn

Experiments were conducted on corn plants using a calibrated spectroradiometer under field conditions in the indium antimonide channel (InSb, 2.8 to 5.6 mm) and the mercury cadmium telluride channel (HgCdTe, 7 to 14 mm). A ground cover experiment, an experiment on nonsystemic corn plants, and an experiment on systemic-stressed corn plants were included. The average spectral radiance temperature of corn plant populations was found (1) to be statistically significantly different for four healthy corn plant populations, (2) to increase with increased blight severity, and (3) to be statistically significantly different for varying rates of nitrogen applications.

Kumar, R.↗

Detection of Jupiter's ring at 2.2 microns

Reflected sunlight from the Jovian ring discovered by the Voyager spacecraft was detected at 2.2 microns. A chopping secondary photometric system and an indium antimonide photovoltaic apparatus were used in the detection. The search for the ring was conducted at 2.2 microns because at this wavelength scattered radiation from the planetary disk is reduced by the strong molecular absorption features in Jupiter's atmosphere.

Becklin, E. E.↗

Infrared heterodyne radiometer for airborne atmospheric transmittance measurements

An infrared heterodyne radiometer (IHR) was used to measure atmospheric transmittance at selected hydrogen fluoride (2.7 micrometer) and deuterium fluoride (3.8 micrometer) laser transitions. The IHR was installed aboard a KC-135 aircraft for an airborne atmospheric measurements program that used the sun as a backlighting source for the transmission measurements. The critical components are: a wideband indium antimonide (1nSb) photomixer, a CW HF/DF laser L0, a radiometric processor, and a 1900 K blackbody reference source. The measured heterodyne receiver sensitivity (NEP) is 1.3 x 10 to the -19th power W/Hz, which yields a calculated IHR temperature resolution accuracy of delta I sub S/-3 sub S = 0.005 for a source temperature of 1000 K and a total transmittance of 0.5. Measured atmospheric transmittance at several wavelengths and aircraft altitudes from 9.14 km (30,000 ft) to 13.72 km (45,000 ft) were obtained during the measurements program and have been compared with values predicted by the AFGL Atmospheric Line Parameter Compilation.

Wolczok, J. M.↗

Infrared Imagery of Shuttle (IRIS). Task 2, summary report

End-to-end tests of a 16 element indium antimonide sensor array and 10 channels of associated electronic signal processing were completed. Quantitative data were gathered on system responsivity, frequency response, noise, stray capacitance effects, and sensor paralleling. These tests verify that the temperature accuracies, predicted in the Task 1 study, can be obtained with a very carefully designed electro-optical flight system. Pre-flight and inflight calibration of a high quality are mandatory to obtain these accuracies. Also, optical crosstalk in the array-dewar assembly must be carefully eliminated by its design. Tests of the scaled up tracking system reticle also demonstrate that the predicted tracking system accuracies can be met in the flight system. In addition, improvements in the reticle pattern and electronics are possible, which will reduce the complexity of the flight system and increase tracking accuracy.

Chocol, C. J.↗

Impact ionization in Ga/1-x/Al/x/Sb - An alternative interpretation

The existence of the recently proposed resonance impact ionization process in gallium aluminum antimonide is questioned. An alternative interpretation of the data originally used to support the claim for a resonant process is presented which invokes only conventional, well-established processes.

Kasemset, D.↗

Integrated Submillimeter-Wave Mixer

Indium arsenide Schottky-Barrier diodes in gallium antimonide substrate mix submillimeter waves, producing much lower frequency output. Integrated diode array has relatively-high signal-to-noise ratio and wide frequency band. Operates at moderate cryogenic temperatures (100 K).

Maserjian, J.↗

Laser system for natural gas detection. Phase 1: Laboratory feasibility studies

This project demonstrated the feasibility of using laser remote sensing technology as a tool for leak survey work in natural gas distribution systems. A laboratory device was assembled using a pair of helium neon (HeNe) lasers to measure methane. One HeNe laser emits radiation at a wavelength of 3.3922 micrometers, which corresponds to a strong absorption feature of methane, while the other emits radiation at a wavelength of 3.3911 micrometers, which corresponds to a weak absorption by methane. As a particular area is scanned for leaks, the laser is pointed at convenient topographic targets within its operating range, about 25 m. A portion of the backscattered radiation is collected by a receiver and focused onto an indium antimonide (InSb) photodetector, cooled to 77K. Methane concentrations were determined from the differential absorption at the two wavelengths for the backscattered radiation.

Grant, W. B.↗