Search NASA⌕ Search

SEARCH · Search NASA

Results for “boost control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Space Launch System Ascent Flight Control Design

A robust and flexible autopilot architecture for NASA's Space Launch System (SLS) family of launch vehicles is presented. As the SLS configurations represent a potentially significant increase in complexity and performance capability of the integrated flight vehicle, it was recognized early in the program that a new, generalized autopilot design should be formulated to fulfill the needs of this new space launch architecture. The present design concept is intended to leverage existing NASA and industry launch vehicle design experience and maintain the extensibility and modularity necessary to accommodate multiple vehicle configurations while relying on proven and flight-tested control design principles for large boost vehicles. The SLS flight control architecture combines a digital three-axis autopilot with traditional bending filters to support robust active or passive stabilization of the vehicle's bending and sloshing dynamics using optimally blended measurements from multiple rate gyros on the vehicle structure. The algorithm also relies on a pseudo-optimal control allocation scheme to maximize the performance capability of multiple vectored engines while accommodating throttling and engine failure contingencies in real time with negligible impact to stability characteristics. The architecture supports active in-flight load relief through the use of a nonlinear observer driven by acceleration measurements, and envelope expansion and robustness enhancement is obtained through the use of a multiplicative forward gain modulation law based upon a simple model reference adaptive control scheme.

VanZwieten, Tannen S.↗

Space Launch System Ascent Flight Control Design

A robust and flexible autopilot architecture for NASA's Space Launch System (SLS) family of launch vehicles is presented. The SLS configurations represent a potentially significant increase in complexity and performance capability when compared with other manned launch vehicles. It was recognized early in the program that a new, generalized autopilot design should be formulated to fulfill the needs of this new space launch architecture. The present design concept is intended to leverage existing NASA and industry launch vehicle design experience and maintain the extensibility and modularity necessary to accommodate multiple vehicle configurations while relying on proven and flight-tested control design principles for large boost vehicles. The SLS flight control architecture combines a digital three-axis autopilot with traditional bending filters to support robust active or passive stabilization of the vehicle's bending and sloshing dynamics using optimally blended measurements from multiple rate gyros on the vehicle structure. The algorithm also relies on a pseudo-optimal control allocation scheme to maximize the performance capability of multiple vectored engines while accommodating throttling and engine failure contingencies in real time with negligible impact to stability characteristics. The architecture supports active in-flight disturbance compensation through the use of nonlinear observers driven by acceleration measurements. Envelope expansion and robustness enhancement is obtained through the use of a multiplicative forward gain modulation law based upon a simple model reference adaptive control scheme.

Orr, Jeb S.↗

ASDTIC control and standardized interface circuits applied to buck, parallel and buck-boost dc to dc power converters

Versatile standardized pulse modulation nondissipatively regulated control signal processing circuits were applied to three most commonly used dc to dc power converter configurations: (1) the series switching buck-regulator, (2) the pulse modulated parallel inverter, and (3) the buck-boost converter. The unique control concept and the commonality of control functions for all switching regulators have resulted in improved static and dynamic performance and control circuit standardization. New power-circuit technology was also applied to enhance reliability and to achieve optimum weight and efficiency.

Schoenfeld, A. D.↗

WE-AB-202-10: Modelling Individual Tumor-Specific Control Probability for Hypoxia in Rectal Cancer

Purpose: To investigate hypoxia-guided dose-boosting for increased tumour control and improved normal tissue sparing using FMISO-PET images Methods: Individual tumor-specific control probability (iTSCP) was calculated using a modified linear-quadratic model with rectal-specific radiosensitivity parameters for three limiting-case assumptions of the hypoxia / FMISO uptake relationship. {sup 18}FMISO-PET images from 2 patients (T3N0M0) from the RHYTHM trial (Investigating Hypoxia in Rectal Tumours NCT02157246) were chosen to delineate a hypoxic region (GTV-MISO defined as tumor-to-muscle ratio > 1.3) within the anatomical GTV. Three VMAT treatment plans were created in Eclipse (Varian): STANDARD (45Gy / 25 fractions to PTV4500); BOOST-GTV (simultaneous integrated boost of 60Gy / 25fr to GTV +0.5cm) and BOOST-MISO (60Gy / 25fr to GTV-MISO+0.5cm). GTV mean dose (in EQD2), iTSCP and normal tissue dose-volume metrics (small bowel, bladder, anus, and femoral heads) were recorded. Results: Patient A showed small hypoxic volume (15.8% of GTV) and Patient B moderate hypoxic volume (40.2% of GTV). Dose escalation to 60Gy was achievable, and doses to femoral heads and small bowel in BOOST plans were comparable to STANDARD plans. For patient A, a reduced maximum bladder dose was observed in BOOST-MISO compared to BOOST-GTV (D0.1cc 49.2Gy vs 54.0Gy). For patient B, a smaller high dose volume was observed for the anus region in BOOST-MISO compared to BOOST-GTV (V55Gy 19.9% vs 100%), which could potentially reduce symptoms of fecal incontinence. For BOOST-MISO, the largest iTSCPs (A: 95.5% / B: 90.0%) assumed local correlation between FMISO uptake and hypoxia, and approached iTSCP values seen for BOOST-GTV (A: 96.1% / B: 90.5%). Conclusion: Hypoxia-guided dose-boosting is predicted to improve local control in rectal tumors when FMISO is spatially correlated to hypoxia, and to reduce dose to organs-at-risk compared to boosting the whole GTV. This could lead to organ-preserving treatment strategies for locally-advanced rectal cancer, thereby improving quality of life. Oxford Cancer Imaging Centre (OCIC); Cancer Research UK (CRUK); Medical Research Council (MRC)

60 APPLIED LIFE SCIENCES↗

High-Power Warm-White Hybrid LED Package for Illumination

In this project, an integrated warm-white hybrid light engine was developed. The hybrid approach involves combining phosphor-converted off-white InGaN LEDs and direct-emitting red AlInGaP LEDs in a single light engine to achieve high efficacy together with high color rendering index. We developed and integrated technology improvements in InGaN and AlInGaP die technology, phosphor technology, package architecture and encapsulation, to realize a hybrid warm-white LED package with an efficacy of 140 lm/W at a correlated color temperature of 3000K and a color rendering index of 90, measured under representative operating conditions. This efficacy is 26% higher than the best warm-white LEDs of similar specification that are commercially available at the end of the project. Since the InGaN- and AlInGaP-based LEDs used in the hybrid engine show different behavior as a function of current and temperature, a control system needs to be in place to ensure a stable color point over all operating conditions. In this project, we developed an electronic control circuit that is fully integrated into the light engine in such a way that the module can simply be driven by a conventional single-channel driver. The integrated control circuit uses a switch-mode boost converter topology to control the LED drive currents based on the temperature and the input current of the light engine. A color control performance of 5 SDCM was demonstrated, and improvement to 3 SDCM is considered well within reach. The combination of high efficacy and ease of integration with existing single-channel drivers is expected to facilitate the adoption of the hybrid technology and accelerate the energy savings associated with solid-state lighting. In the product commercialization plan, downlights and indirect-lit troffers have been selected as the first target applications for this product concept. Fully functional integrated prototypes have been developed for both applications, and the business case evaluation is ongoing as of the end of the project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Improved Boosting to Amplify Signal with Isobaric Labeling (iBASIL) Strategy for Precise Quantitative Single-cell Proteomics

Mass spectrometry (MS)-based proteomics has great potential for overcoming the limitations of antibody-based immunoassays for antibody-independent, comprehensive, and quantitative proteomic analysis of single cells. Indeed, recent advances in nanoscale sample preparation have enabled effective processing of single cells. In particular, the concept of using boosting/carrier channels in isobaric labeling to increase the sensitivity in MS detection has also been increasingly used for quantitative proteomic analysis of small-sized samples including single cells. However, the full potential of such boosting/carrier approaches has not been significantly explored, nor has the resulting quantitation quality been carefully evaluated. Herein, we have further evaluated and optimized our recent boosting to amplify signal with isobaric labeling (BASIL) approach, originally developed for quantifying phosphorylation in small number of cells, for highly effective analysis of proteins in single cells. This improved BASIL (iBASIL) approach enables reliable quantitative single-cell proteomics analysis with greater proteome coverage by carefully controlling the boosting-to-sample ratio (e.g. in general <100×) and optimizing MS automatic gain control (AGC) and ion injection time settings in MS/MS analysis (e.g. 5E5 and 300 ms, respectively, which is significantly higher than that used in typical bulk analysis). By coupling with a nanodroplet-based single cell preparation (nanoPOTS) platform, iBASIL enabled identification of ~2500 proteins and precise quantification of ~1500 proteins in the analysis of 104 FACS-isolated single cells, with the resulting protein profiles robustly clustering the cells from three different acute myeloid leukemia cell lines. This study highlights the importance of carefully evaluating and optimizing the boosting ratios and MS data acquisition conditions for achieving robust, comprehensive proteomic analysis of single cells.

59 BASIC BIOLOGICAL SCIENCES↗

Development and Implementation of an Automatic Continuous Online Monitoring and Control Platform for Polymerization Reactions to Sharply Boost Energy and Resource Efficiency in Polymer Manufacturing

The project goal was to create an energy saving paradigm shift in how polymers are manufactured in the 21st century. It used Automatic Continuous Online Monitoring of Polymerization reactions (ACOMP) integrated for the first time with automatic active control to create the innovative ‘ACOMP/Control Interface’, or ‘ACOMP/CI’. ACOMP/CI will begin the transformation from old, inefficient processes into highly evolved, energy and resource efficient ones. The ACOMP platform is broadly applicable to many types of reactions and processes throughout the vast polymer industry. The industry provides materials for sectors such as automotive, aerospace, oil recovery, agriculture, paints, resins, adhesives, pharmaceuticals and therapeutic proteins, optics, electronics, lightweight building materials, and many more. The U.S. chemical industry is one of the last major sectors in which the U.S. has top global stature. It consumes 24% of all U.S. manufacturing energy, produces over $800B of product annually, supports 25% of the U.S. GDP and employs over 6 million people. It is also a major source of GHG emissions. Polymers make up approximately 30% of this sector. It is estimated that annually 60 TBtu of energy could be saved and 3 million tons less of GHG emissions produced by optimizing production in the polyolefin manufacturing sector alone. The project scope included first time design and prototyping of an ACOMP/CI, creation of active reaction controllers, and demonstration of control capabilities on ideal, low concentration polymerization reactions. All these elements of the scope were met, including advances and findings not originally anticipated. Extensions to more complex reactions, beyond the reactor capabilities of the current project ACOMP/CI, such as polyolefins and other high pressure/high temperature reactions, are being proposed in Fall 2017 to CESMII, a DoE based NNMI. The initial proposal was for a three year funded project, but this was reduced to a two year project and budget due to funding constraints. Hence, some of the original plans, such as adaptation of the ACOMP/CI to more relevant industrial processes, such as emulsion and dispersion technologies, could not be carried out. A third year of funding was requested at the end of the project, but DoE did not have resources to grant this. The sub-contractor Fluence Analytics (previously Advanced Polymer Monitoring Technologies, Inc) designed, prototyped, and commissioned a working ACOMP/CI by June 2015. The reaction characteristics to be automatically controlled were i) conversion kinetics, ii) molecular weight, iii) copolymer composition, and iv) simultaneous molecular weight and composition. A two pronged control strategy was used. The Tulane/Fluence group took a basic principles approach that did not rely on kinetic models. The LSU group took a more complex, non-linear model-oriented approach involving complete kinetic descriptions of the reaction system Each of these approaches proved successful in their own way. By April 2016 fully automatic control of conversion and weight average molecular weight, Mw, trajectories was achieved using the Tulane/Fluence (TF) basic principles controller. Similar results were obtained by the LSU non-linear model controller by August 2016. The demonstration system was aqueous free radical polymerization of acrylamide, Am. The control variables were temperature and semi-batch feed to the reactor of Am monomer and initiator. A demonstration of active manual conversion control in an industrial process using high solids in inverse emulsion polymerization of Am was achieved. During Summer 2016 the TF controller was used in conjunction with a chain transfer agent, another control variable, to automatically produce multi-modal molecular weight distributions, MWD, in a single reactor. Industrially, multi-modal MWD are produced by mixing products made in separate reactors, requiring significant extra time, energy, and reactor resources. Recognizing the industrial potential a patent on automatic production of multi-modal polymers was filed, and DoE acknowledged. In Fall 2016 the TF team developed a basic principles controller for copolymer composition and demonstrated it on aqueous free radical copolymerization of comonomers Am and styrene sulfonate, SS. TF then fused the Mw and composition controllers to achieve simultaneous control of both Mw and copolymer composition trajectories. Numerous simultaneous trajectories were demonstrated, including a trimodal composition distribution with constant Mw. Meanwhile, the LSU group developed a Kalman filter to improve the results of their automatic Mw and conversion controller and successful tests were made. During the project the TF team developed a means of computing full MWD during polymer synthesis without need for any chromatographic separation, based on model distributions. This means the polymer product is ‘born characterized’ and this can eliminate post-manufacture analytical laboratory quality control. TF filed a joint patent application on this new approach to chromatography-free determination of MWD with acknowledgment to DoE. The Tulane group obtained a 60MHz NMR during the project and recently completed the first work on separating three comonomers, Am, SS, and Na-acrylate, with a first demonstration of terpolymer composition control with the TF basic principles controller. Widespread dissemination of ACOMP/CI in the polymer manufacturing sector will bolster DoE goals of energy efficiency and reduced GHG emissions: The ability to monitor and actively control polymerization reactions will lead to more efficient use of energy and non-renewable resources, plant and labor time, increase the safety of manufacturing personnel, and will enhance product quality and lead to feasibility of manufacturing of polymers currently too complex for industrial scale production, while leading to less GHG emissions per kilo of product, and allowing for increased U.S. competitiveness in this enormous manufacturing sector. When ACOMP/CI is expanded to the polyolefin industry it is estimated that 60 TeraBTU/year of energy can be saved. Much of this saving is anticipated to come from optimized control of grade changeovers in steady state reactors and maintenance of steady states. Conclusions: ACOMP’s ability to provide continuous realtime data streams of measured polymer and reaction characteristics made it possible, for the first time, to directly and automatically control free radical polymerization reactions. An industrial client of Fluence Analytics has requisitioned the first ACOMP/CI which uses the TF basic principles controller. This sets the stage for FA to add control features to the ACOMP systems it has begun to install on the industrial scale beginning in 2014. Recommendations: This successful project was mainly limited to ideal polymerizations not of an industrial sort. The most energy intensive portion of polymer manufacturing is polyolefins. Adoption of ACOMP/CI to this enormous industrial sector faces the enormous challenges of high temperature, high pressure continuous sampling and high temperature sensor operation to obtain the continuous data needed for direct reaction control. The project team has a strategy for achieving this ambitious goal and will present it in Fall 2017 as a proposal to CESMII/DoE. It is recommended that this upcoming proposal be funded in order to make full use of the achievements of this just ended DoE project as the next step towards making polyolefin ACOMP/CI an energy saving reality. It is projected that ACOMP/CI can have its first polyolefin testbed demonstrations within two years of beginning the proposed project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Quality of Life in Women Undergoing Breast Irradiation in a Randomized, Controlled Clinical Trial Evaluating Different Tumor Bed Boost Fractionations

Purpose: To identify differences in breast cancer patient-reported quality of life (QOL) between 2 radiation tumor bed boost dose regimens. Methods and Materials: Four hundred patients with stage 0, I, or II breast cancer who underwent segmental mastectomy with sentinel node biopsy and/or axillary node dissection were treated with either a daily or weekly boost. Patients were treated prone to 40.5 Gy/15 fractions to the whole breast, 5 days per week. Patients were randomized to a concomitant daily boost to the tumor bed of 0.5 Gy, or a weekly boost of 2 Gy on Friday. Patients completed 6 validated QOL survey instruments at baseline, last week of treatment (3 weeks), 45-60 days from the completion of radiation treatment, and at 2-year follow-up. Results: There were no statistically significance differences in responses to the 6 QOL instruments between the daily and weekly radiation boost regimens, even after adjustment for important covariates. However, several changes in responses over time occurred in both arms, including worsening functional status, cosmetic status, and breast-specific pain at the end of treatment as compared with before and 45 to 60 days after the conclusion of treatment. Conclusions: Whole-breast, prone intensity modulated radiation has similar outcomes in QOL measures whether given with a daily or weekly boost. This trial has generated the foundation for a current study of weekly versus daily radiation boost in women with early breast cancer in which 3-dimensional conformal radiation is allowed as a prospective stratification factor.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Single-Phase Active Boost Rectifier with Power Factor Correction for Wireless Power Transfer Applications

Wireless Power Transfer (WPT) technology is a novel research area in the charging technology that bridges utility and the automotive industries. There are various solutions that are currently being evaluated by several research teams to find the most efficient way to manage the power flow from the grid to the vehicle energy storage system. There are different control parameters that can be utilized to compensate for the change in the impedance. To understand the power flow through the system this paper presents a novel approach to the system model and the impact of different control parameters on the load power. The implementation of an active front-end rectifier on the grid side for power factor control and voltage boost capability for load power regulation is also discussed.

PEV charging↗

SiC MOSFET Based Single Phase Active Boost Rectifier with Power Factor Correction for Wireless Power Transfer Applications

Wireless Power Transfer (WPT) technology is a novel research area in the charging technology that bridges the utility and the automotive industries. There are various solutions that are currently being evaluated by several research teams to find the most efficient way to manage the power flow from the grid to the vehicle energy storage system. There are different control parameters that can be utilized to compensate for the change in the impedance due to variable parameters such as battery state-of-charge, coupling factor, and coil misalignment. This paper presents the implementation of an active front-end rectifier on the grid side for power factor control and voltage boost capability for load power regulation. The proposed SiC MOSFET based single phase active front end rectifier with PFC resulted in >97% efficiency at 137mm air-gap and >95% efficiency at 160mm air-gap.

active rectifier↗

Five-year Local Control in a Phase II Study of Hypofractionated Intensity Modulated Radiation Therapy With an Incorporated Boost for Early Stage Breast Cancer

Purpose: Conventional radiation fractionation of 1.8-2 Gy per day for early stage breast cancer requires daily treatment for 6-7 weeks. We report the 5-year results of a phase II study of intensity modulated radiation therapy (IMRT), hypofractionation, and incorporated boost that shortened treatment time to 4 weeks. Methods and Materials: The study design was phase II with a planned accrual of 75 patients. Eligibility included patients aged {>=}18 years, Tis-T2, stage 0-II, and breast conservation. Photon IMRT and an incorporated boost was used, and the whole breast received 2.25 Gy per fraction for a total of 45 Gy, and the tumor bed received 2.8 Gy per fraction for a total of 56 Gy in 20 treatments over 4 weeks. Patients were followed every 6 months for 5 years. Results: Seventy-five patients were treated from December 2003 to November 2005. The median follow-up was 69 months. Median age was 52 years (range, 31-81). Median tumor size was 1.4 cm (range, 0.1-3.5). Eighty percent of tumors were node negative; 93% of patients had negative margins, and 7% of patients had close (>0 and <2 mm) margins; 76% of cancers were invasive ductal type: 15% were ductal carcinoma in situ, 5% were lobular, and 4% were other histology types. Twenty-nine percent of patients 29% had grade 3 carcinoma, and 20% of patients had extensive in situ carcinoma; 11% of patients received chemotherapy, 36% received endocrine therapy, 33% received both, and 20% received neither. There were 3 instances of local recurrence for a 5-year actuarial rate of 2.7%. Conclusions: This 4-week course of hypofractionated radiation with incorporated boost was associated with excellent local control, comparable to historical results of 6-7 weeks of conventional whole-breast fractionation with sequential boost.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Supplementary Investigation in the Langley 20-Foot Free-Spinning Tunnel of the Spin and Recovery Characteristics of a 0.057-Scale Model of the Chance Vought XFU-1 Airplane, Ted No. NACA DE 311

An investigation has been conducted in the Langley 20-foot free-spinning tunnel to determine the effects of decreasing the rudder deflection, of decreasing the rudder span, and of differential rudder movements on the spin and recovery characteristics of a 0.057-scale model of the Chance Vought XF7U-1 airplane. The results indicated that decreasing the rudder span or the rudder deflections, individually or jointly, did not seriously alter the spin or recovery characteristics of the model; and recovery by normal use of controls (full rapid rudder reversal followed l/2 to 1 turn later by movement of the stick forward of neutral) remained satisfactory. Linking the original rudders so that the inboard rudder moves from full with the spin to neutral while the outboard rudder moves from neutral to full against the spin will also result in satisfactory spin and recovery characteristics. Calculations of rudder-pedal forces for recovery showed that the expected forces would probably be within the capabilities of a pilot but that it would be advisable to install some type of boost in the control system to insure easy and rapid movement of the rudders.

Berman, Theodore↗

Prospective Study of Local Control and Late Radiation Toxicity After Intraoperative Radiation Therapy Boost for Early Breast Cancer

Purpose: To report the local recurrence rate and late toxicity of intraoperative radiation therapy (IORT) boost to the tumor bed using the Intrabeam System followed by external-beam whole-breast irradiation (WBI) in women with early-stage breast cancer in a prospective single-institution study. Methods and Materials: Women with breast cancer ≤3 cm were recruited between February 2003 and May 2005. After breast-conserving surgery, a single dose of 5 Gy IORT boost was delivered using 50-kV x-rays to a depth of 10 mm from the applicator surface. This was followed by WBI to a total dose of 50 Gy in 25 fractions. Patients were reviewed at regular, predefined intervals. Late toxicities were recorded using the Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer Late Radiation Morbidity Scoring systems. Results: Fifty-five patients completed both IORT boost and external-beam WBI. Median follow-up was 3.3 years (range, 1.4-4.1 years). There was no reported locoregional recurrence or death. One patient developed distant metastases. Grade 2 and 3 subcutaneous fibrosis was detected in 29 (53%) and 8 patients (15%), respectively. Conclusions: The use of IORT as a tumor bed boost using kV x-rays in breast-conserving therapy was associated with good local control but a clinically significant rate of grade 2 and 3 subcutaneous fibrosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Long-Term Results of a Randomized Trial in Locally Advanced Rectal Cancer: No Benefit From Adding a Brachytherapy Boost

Purpose/Objective(s): Mature data on tumor control and survival are presented from a randomized trial of the addition of a brachytherapy boost to long-course neoadjuvant chemoradiation therapy (CRT) for locally advanced rectal cancer. Methods and Materials: Between March 2005 and November 2008, 248 patients with T3-4N0-2M0 rectal cancer were prospectively randomized to either long-course preoperative CRT (50.4 Gy in 28 fractions, per oral tegafur-uracil and L-leucovorin) alone or the same CRT schedule plus a brachytherapy boost (10 Gy in 2 fractions). The primary trial endpoint was pathologic complete response (pCR) at the time of surgery; secondary endpoints included overall survival (OS), progression-free survival (PFS), and freedom from locoregional failure. Results: Results for the primary endpoint have previously been reported. This analysis presents survival data for the 224 patients in the Danish part of the trial. In all, 221 patients (111 control arm, 110 brachytherapy boost arm) had data available for analysis, with a median follow-up time of 5.4 years. Despite a significant increase in tumor response at the time of surgery, no differences in 5-year OS (70.6% vs 63.6%, hazard ratio [HR] = 1.24, P=.34) and PFS (63.9% vs 52.0%, HR=1.22, P=.32) were observed. Freedom from locoregional failure at 5 years were 93.9% and 85.7% (HR=2.60, P=.06) in the standard and in the brachytherapy arms, respectively. There was no difference in the prevalence of stoma. Explorative analysis based on stratification for tumor regression grade and resection margin status indicated the presence of response migration. Conclusions: Despite increased pathologic tumor regression at the time of surgery, we observed no benefit on late outcome. Improved tumor regression does not necessarily lead to a relevant clinical benefit when the neoadjuvant treatment is followed by high-quality surgery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Operator splitting method for simulation of dynamic flows in natural gas pipeline networks

Here, we develop an operator splitting method to simulate flows of isothermal compressible natural gas over transmission pipelines. The method solves a system of nonlinear hyperbolic partial differential equations (PDEs) of hydrodynamic type for mass flow and pressure on a metric graph, where turbulent losses of momentum are modeled by phenomenological Darcy-Weisbach friction. Mass flow balance is maintained through the boundary conditions at the network nodes, where natural gas is injected or withdrawn from the system. Gas flow through the network is controlled by compressors boosting pressure at the inlet of the adjoint pipe. Our operator splitting numerical scheme is unconditionally stable and it is second order accurate in space and time. The scheme is explicit, and it is formulated to work with general networks with loops. We test the scheme over range of regimes and network configurations, also comparing its performance with performance of two other state of the art implicit schemes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cryogenic insulation development

Multilayer insulations for long term cryogenic storage are described. The development effort resulted in an insulation concept using lightweight radiation shields, separated by low conductive Dacron fiber tufts. The insulation is usually referred to as Superfloc. The fiber tufts are arranged in a triangular pattern and stand about .040 in. above the radiation shield base. Thermal and structural evaluation of Superfloc indicated that this material is a strong candidate for the development of high performance thermal protection systems because of its high strength, purge gas evacuation capability during boost, its density control and easy application to a tank.

Leonhard, K. E.↗

Analysis and design of a standardized control module for switching regulators

Three basic switching regulators: buck, boost, and buck/boost, employing a multiloop standardized control module (SCM) were characterized by a common small signal block diagram. Employing the unified model, regulator performances such as stability, audiosusceptibility, output impedance, and step load transient are analyzed and key performance indexes are expressed in simple analytical forms. More importantly, the performance characteristics of all three regulators are shown to enjoy common properties due to the unique SCM control scheme which nullifies the positive zero and provides adaptive compensation to the moving poles of the boost and buck/boost converters. This allows a simple unified design procedure to be devised for selecting the key SCM control parameters for an arbitrarily given power stage configuration and parameter values, such that all regulator performance specifications can be met and optimized concurrently in a single design attempt.

Lee, F. C.↗