An investigation of conducted and radiated emissions from a hollow-cathode plasma contactor

An investigation conducted on the electrical interference induced by the operation of a hollow-cathode plasma contractor in a ground-based facility is described. The types of electrical interference, or noise, which are important to Space Station Freedom designers are classified as either conducted or radiated emissions. The procedures required to perform conducted and radiated emission measurements on a plasma contactor are examined. The experimental data obtained are typically examined in the frequency domain (i.e. amplitudes of the noise fluctuations versus frequency). Results presented indicate the conducted emissions, which are the current fluctuations from the contactor into the space station wiring, are affected by operating parameters such as expellant flow rate and discharge current. The radiated emissions, which are the electromagnetic waves induced and emitted by the contactor, appear to be influenced by the contactor emission current. Other experimental results suggest possible sources which are responsible for the observed noise. For example, the influence of the plasma environment downstream from the contactor on noise emission levels is described. In addition, a brief discussion is given on the correlation between conducted and radiated emissions and the mechanisms through which both are influenced by the plasma downstream of the contactor.

Buchholtz, Brett W.↗

Grid Sphere Electrodes used for Current Collection at the Positive Pole of Electrodynamic Tethers

The generation of either electrical power or propulsive thrust with an electrodynamic tether system necessarily depends on driving a return current through the system's ambient space plasma environment. An electrical connection is, therefore, required between the plasma and each end of the tether. The voltage required to drive current through the system is derived either from the orbital motion of the conducting tether through the magnetic field of the Earth, or from a high-voltage power supply that taps into an external energy source (e.g., the sun). In either case, one end of the tether will receive a positive bias. This positive bias, between the tether and the ambient plasma, allows electrons to be collected effectively with a simple, passive electrode. Passive electrode contactors offer several important advantages, including simplification of the upper end-body design and operations, minimization of system mass, and an increase of system reliability and robustness. A preliminary analysis of an inflatable Grid-Sphere end-body concept is presented that is interesting because of the potential for collecting arbitrarily large currents independent of tether length, while the device has the physical characteristics of a high area-to-mass ratio, a low drag coefficient, and simplicity. In particular, we will discuss the physics of current collection by a biased Grid-Sphere and the present state-of-the-art of materials, attainable area-to-mass ratios, and deployment techniques.

Stone, N. H.↗

Xenon ion sources for space applications

The technology of xenon ion thrusters under development for space-propulsion and plasma-contactor applications is described with particular consideration given to the 1.4-kW Xenon Ion Propulsion Subsystem (XIPS) designed for the upcoming Atmospheric Laboratory for Applications and Science Shuttle-based missions. The 25-cm-diam ion thruster of the XIPS is able to convert input power into thrust-beam power with an efficiency of over 82 percent. The XIPS will be used for satellite stationkeeping and orbit raising and maneuvering and as a plasma contactor. A 1991 flight application is described in which the 25-cm XIPS plasma contactor will be used to stabilize the electrical potential of the Shuttle Orbiter during firings of a 1.5-A electron beam from its payload bay.

Beattie, J. R.↗

ISS and Space Environment Interactions in Event of Plasma Contactor Failure

The International Space Station (ISS), illustrated in Figure 1, will be the largest, highest power spacecraft placed in orbit. Because of this the design of the electrical power system diverged markedly from previous systems. The solar arrays will operate at 160 V and the power distribution voltage will be 120 V. The structure is grounded to the negative side of the solar arrays so under the right circumstances it is possible to drive the ISS potential very negative. A plasma contactor has been added to the ISS to provide control of the ISS structure potential relative to the ambient plasma. The ISS requirement is that the ISS structure not be greater than 40 V positive or negative of local plasma. What are the ramifications of operating large structures with such high voltage power systems? The application of a plasma contactor on ISS controls the potential between the structure and the local plasma, preventing degrading effects. It is conceivable that there can be situations where the plasma contactor might be non-functional. This might be due to lack of power, the need to turn it off during some of the build-up sequences, the loss of functionality for both plasma contactors before a replacement can be installed, and similar circumstances. A study was undertaken to understand how important it is to have the contactor functioning and how long it might be off before unacceptable degradation to ISS could occur.

Carruth, M. R., Jr.↗

Floating Potential Probe Deployed on the International Space Station

In the spring and summer of 2000, at the request of the International Space Station (ISS) Program Office, a Plasma Contactor Unit Tiger Team was set up to investigate the threat of the ISS arcing in the event of a plasma contactor outage. Modeling and ground tests done under that effort showed that it is possible for the external structure of the ISS to become electrically charged to as much as -160 V under some conditions. Much of this work was done in anticipation of the deployment of the first large ISS solar array in November 2000. It was recognized that, with this deployment, the power system would be energized to its full voltage and that the predicted charging would pose an immediate threat to crewmembers involved in extravehicular activities (EVA's), as well as long-term damage to the station structure, were the ISS plasma contactors to be turned off or stop functioning. The Floating Potential Probe was conceived, designed, built, and deployed in record time by a crack team of scientists and engineers led by the NASA Glenn Research Center in response to ISS concerns about crew safety.

Ferguson, Dale C.↗

Scale-Up of the Carbon Dioxide Removal by Ionic Liquid Sorbent (CDRILS) System

The Carbon Dioxide Removal by Ionic Liquid Sorbent (CDRILS) system is designed for efficient, safe and reliable carbon dioxide (CO2) removal from cabin air on long-duration missions to the Moon, deep space, and Mars. CDRILS integrates an ionic liquid sorbent with hollow fiber membrane contactors for rapid CO2 removal and recovery. The liquid-based system provides continuous CO2 delivery, which avoids complicated valve networks to switch between absorbing and desorbing beds and enables simpler integration to the Sabatier without the need for the CO2 Management System (CMS). Ionic liquids are particularly desirable as liquid absorbents for space applications since they are non-volatile, non-odorous, and have high oxidative stability. The hollow fiber membrane contactors offer both high contact area and rigorous containment between the gas and liquid phases in a microgravity environment. Scale-up of the CDRILS technology has presented a series of fascinating challenges, since the interaction between hollow fiber properties, ionic liquid properties and performance is complex. Properties measured with lab-scale hollow fiber contactors are used to estimate the performance of contactors that are similar in scale to flight-scale demonstrations. To accomplish this, component and system models have been built to relate the key scrubber and stripper design and operating variables with performance, and experiments directed to validate the models have been performed. System size, weight and power are determined by component selection, arrangement, and operating conditions. Reliability will be extremely important for any long-range mission and depends on the stability of the ionic liquids and hollow fiber contactors. We report on our continuing long term stability experiments for the ionic liquid and contactor materials and our investigation of the physical properties of additional ionic liquids.

Yates, Stephen F.↗

Hollow cathode heater development for the Space Station plasma contactor

A hollow cathode-based plasma contactor has been selected for use on the Space Station. During the operation of the plasma contactor, the hollow cathode heater will endure approximately 12000 thermal cycles. Since a hollow cathode heater failure would result in a plasma contactor failure, a hollow cathode heater development program was established to produce a reliable heater design. The development program includes the heater design, process documents for both heater fabrication and assembly, and heater testing. The heater design was a modification of a sheathed ion thruster cathode heater. Three heaters have been tested to date using direct current power supplies. Performance testing was conducted to determine input current and power requirements for achieving activation and ignition temperatures, single unit operational repeatability, and unit-to-unit operational repeatability. Comparisons of performance testing data at the ignition input current level for the three heaters show the unit-to-unit repeatability of input power and tube temperature near the cathode tip to be within 3.5 W and 44 degrees C, respectively. Cyclic testing was then conducted to evaluate reliability under thermal cycling. The first heater, although damaged during assembly, completed 5985 ignition cycles before failing. Two additional heaters were subsequently fabricated and have completed 3178 cycles to date in an on-going test.

Soulas, George C.↗

Design for an Integrated Open-Loop System for Carbon Dioxide Removal using Liquid Amine

Manned Space missions require maintaining a safe environment for the crew that can both sustain a breathable atmosphere and remove pollutants. Carbon dioxide, while not toxic in low concentrations, accumulates as crew members work and breath and can eventually affect the crew’s health. Therefore, a constant, passive system to remove the carbon dioxide build up is necessary for long-term missions. Currently, the prevailing liquid sorbent used in submarines and industrial flue gas utilizes the primary amine, monoethanolamine (MEA), to capture, transfer, and remove carbon dioxide from air. Diglycolamine (DGA) is an alternate primary amine that has similar performance and less volatility. It is currently being studied at Ames Research Center (ARC) and is the primary candidate for the operation of the sub-scale liquid amine test stand. The test stand is used to investigate liquid flow and liquid gas interfaces to assist in a system design for microgravity applications. The test stand includes a wedge design utilizes capillary action to hold the liquid while allowing gas-liquid interaction for carbon dioxide transfer. These wedge trays are placed in a contactor unit to remove carbon dioxide from the air stream, a degasser unit to replenish the liquid amine, and a capillary condensing heat exchanger (CCHX) to recapture water lost in the degasser unit. Nominal operating conditions for the contactor are a gas flow rate of 26scfm enriched with pure CO2 to 2600ppm and a liquid mixture of 65/35 vol% DGA/H2O at 0.65mL/min while the degasser was operated at 100°C and 1 atm. This paper discusses the challenges and limitations of a fully integrated system which will influence the design of a new subscale test stand.

Adrian Cortez↗

Acoustic Measurements of Solvent Extraction Processes in Support of Safeguards

The proposed poster focuses on using acoustic monitoring to advance detection techniques for reprocessing equipment in support of nuclear safeguards. The usage of free air acoustic monitoring has been previously demonstrated at Idaho National Laboratory (INL) at facilities such as the Advanced Test Reactor and the National Security Test Range. However, this work focuses on a deployment environment dedicated to monitoring separation processes, using solvent extraction equipment such as centrifugal contactors. This environment offers an opportunity for signal discovery and in characterizing acoustic signatures of the equipment in operation. This data can support the development of safeguards by design and security by design measures for aqueous reprocessing facilities. Furthermore, this type of monitoring can aid in early detection and identification of removed materials indicating diversion, which is essential for initiating material recovery and actor identification. The results of this work include data from nine low-frequency acoustic sensors used to investigate potential acoustic characteristics of centrifugal contactors used in multi-stage processes. The results also discuss the correlation between the signatures and the operation of the contactor banks.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗

Isotherm modeling and techno-economic analysis of a TSA moving bed process using a tetraamine-appended MOF for NGCC applications

Tetraamine-appended metal-organic frameworks (MOF) are a new family of amine-functionalized MOF materials that show potential for CO 2 capture from flue gas conditions relevant to natural gas combined cycle (NGCC) power plants. This work presents isotherm modeling of the tetraamine-appended MOF Mg 2 (dobpdc)(3-4-3)(dobpdc 4- =4,4'-dioxidobiphenyl-3,3'dicarboxylate;3-4-3=N,N'bis(3-aminopropyl)-1,4-diaminobutane), process modeling, scale up, and a techno-economic optimization of a moving bed Temperature Swing Adsorption (TSA) process for carbon capture using this sorbent. This MOF exhibits a unique two-step CO 2 adsorption profile in three different pressure ranges. Thus, arctangent-based logistic functions and, quadratic and Langmuir models were employed to represent such isotherm behavior. The results of the isotherm model show good fitting vs the experimental data with an RMSE of 0.41. Here, to model the carbon capture process, the isotherm model was embedded into a moving bed contactor model, and this was used to simulate a TSA CO 2 capture cycle and evaluate cost-optimal designs considering flue gas from a -650 MWe NGCC power plant. The capital cost model consists of CAPEX correlations for reactors, compressors, ducting, etc., while the operating costs include steam, water, chemicals, and electricity (following NETL's quality guidelines for energy systems studies). A techno-economic optimization of the capture system was performed by using NETL's Framework for the Optimization and Quantification of Uncertainty and Surrogates tool (FOQUS). Results suggest that a moving bed carbon capture system with tetraamine-appended MOF can be competitive compared to conventional MEA solvent-based capture processes for NGCC plants, when a heat recovery efficiency of at least 40% is achieved, and MOF materials can be produced at a cost below -$9/kg.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Regenerable Incinerator Exhaust Purification and Trace Contaminant Control System

In this novel approach to air purification, contaminants removed from a process air stream by a high-capacity adsorbent are displaced periodically by a warm, high-humidity, reverse-flow air stream. Displaced contaminants flow into a closed regeneration loop, in which organic compounds are oxidized catalytically and acid gases are removed by a gas- water contactor (which also serves as the source of the water vapor). These features are expected to result in a design that has few expendables and lower energy consumption than alternative regenerable techniques. The joint project between NASA Ames Research Center and Vanderbilt University has completed its third year. Breadboard development continues at NASA Ames, while Vanderbilt has completed most of its adsorption equilibria development. Vanderbilt has completed its fixed-bed apparatus for investigation of dynamic adsorption and desorption processes for trace organic compounds and water vapor, and is continuing its development of the mathematical model describing the column dynamics.

Finn, John E.↗

Plasma Bubble Column Reactor: A High Throughput Reactor Design for Water Treatment

Plasma-based water treatment (PWT) is a promising technology that can degrade various emerging contaminants. However, PWT application on an industrially viable scale is hindered by the lack of an efficient reactor design that combines enhanced plasma-liquid contact with high liquid throughput. This work investigates the applicability of a bubble column gas-liquid contactor to PWT. A pulsed plasma bubble column reactor (PBCR) with a concentric rod-cylinder electrode configuration was used to correlate contaminant removal performance with the gas-liquid contact parameters of the bubble column. A surfactant, rhodamine B dye, and a nonsurfactant, caffeine, were used as model contaminants at µM concentration levels. The bubble column characteristics, i.e., gas holdup, bubble size distribution, and gas-liquid area, were measured as a function of superficial gas velocity using image-based methods. Degradation rates of both contaminants increased with gas flowrate. For caffeine, the increase was attributed to intensified bulk liquid mixing, while dye degradation increased due to the increased gas-liquid area. Ultimately, we show that bubble column contactors significantly improve the utilization of plasma-generated reactive species toward contaminant degradation by distributing them over a large contact area. As a result, a better match between the plasma species interfacial flux and the interfacial contaminant concentration leads to improved treatment energy efficiency. Furthermore, typical degradation energy efficiencies were ~10 g/kWh for caffeine and ~60 g/kWh for rhodamine B.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Review of Testing of Hollow Cathodes for the International Space Station Plasma Contactor

Since October 2000, two plasma contactors have been providing charge control on the International Space Station (ISS). At the heart of each of the two plasma contactors is a hollow cathode assembly (HCA) that produces the contacting xenon plasma. The HCA is the result of 9 years of design and testing at the NASA Glenn Research Center. This paper summarizes HCA testing that has been performed to date. As of this time, one cathode has demonstrated approximately 28,000 hr of lifetime during constant, high current use. Another cathode, HCA.014. has demonstrated 42,000 ignitions before cathode heater failure. In addition to these cathodes, four cathodes. HCA.006, HCA.003, HCA.010, and HCA.013 have undergone cyclic testing to simulate the variable current demand expected on the ISS. HCA.006 accumulated 8,000 hr of life test operation prior to being voluntarily stopped for analysis before the flight units were fabricated. HCA.010 has accumulated 15,876 hr of life testing, and 4,424 ignitions during ignition testing. HCA.003 and HCA.0 13 have accumulated 12,415 and 18,823 hr of life testing respectively.

Kovaleski, S. D.↗

Efficacy of FTIR Analysis in Determining CO2 Loading on Diglycolamine

In support of advanced air revitalization technologies to enable human spaceflight beyond low earth orbit, performance studies have been conducted using a liquid amine, Diglycolamine (DGA) between teams at NASA's Johnson Spaceflight Center (JSC) and Ames Research Center (ARC). Liquid amines have been used in regenerable earth-based systems to remove CO2 from industrial systems as well as for closed-environment air revitalization because they can be regenerated at lower temperatures than solid sorbent systems. As an additional advantage to solid sorbent-based systems, liquid sorbents can be cycled between an adsorbing contactor and degassing chamber, thereby reducing system complexity by operation in a continuous loop. In an effort to inform a regeneration system design for micro-gravity applications, ARC has performed a number of tests to characterize the degas mechanics of DGA. In order to accurately measure the amount of CO2 captured or released by the amine, methods such as gravimetric weighing and chemical desorption are reasonable, however the first iteration test setup for a scaled down degas system required analysis on small sample sizes. Fourier-transform infrared spectroscopy (FTIR) analysis was experimentally evaluated to analyze CO2 concentration because it can produce measurements with sample sizes on the order of 100's of μL. Calibration against chemical desorption showed relatively good correlation and test data showed reasonable adherence to expected trends, however more extensive testing should be conducted to fully validate the usage of FTIR to determine CO2 loading on DGA.

Diglycolamine↗

Efficacy of FTIR Analysis in Determining CO2 Loading on Diglycolamine

In support of advanced air revitalization technologies to enable human spaceflight beyond low earth orbit, performance studies have been conducted using a liquid amine, Diglycolamine (DGA) between teams at NASA?s Johnson Spaceflight Center (JSC) and Ames Research Center (ARC). Liquid amines have been used in regenerable earth-based systems to remove CO2 from industrial systems as well as for closed-environment air revitalization because they can be regenerated at lower temperatures than solid sorbent systems. As an additional advantage to solid sorbent based systems, liquid sorbents can be cycled between an adsorbing contactor and degassing chamber, thereby reducing system complexity by operation in a continuous loop. In an effort to inform a regeneration system design for micro-gravity applications, ARC has performed a number of tests to characterize the degas mechanics of DGA. In order to accurately measure the amount of CO2 captured or released by the amine, methods such as gravimetric weighing and chemical decomposition are reasonable, however the initial design for a scaled down degas system required analysis on small sample sizes. In order to accomplish CO2 loading measurements with a sample size of approximately 500µL, Fourier-transform infrared spectroscopy (FTIR) was used. Calibration against acid decomposition showed relatively good correlation and test data showed reasonable adherence to expected trends, however more extensive testing should be conducted to fully validate the usage of FTIR to determine CO2 loading on DGA.

Diglycolamine↗

Bench-Scale Testing of Monolithic PPI Structured Contactors for Direct Air Capture of CO 2

The overall project objective was to develop, optimize and bench-scale test the integrated embodiment of a leading direct air capture (DAC) sorbent composition, linear-poly(propylenimine) (l-PPI), in a structured material system, specifically a monolithic contactor for achieving low pressure drop, to justify its further scale-up in a subsequent program. The project team was led by CORMETECH, a leading monolithic gas/solid contactor manufacturer for environmental applications, and included Global Thermostat, a well-known DAC start-up, and Georgia Tech, a prominent US academic institution in carbon capture and DAC. The monolithic contactor for l-PPI in this project employed an advanced, cost-effective fabrication technique from CORMETECH, namely a porous monolith substrate directly impregnated with the amine, an approach contrasting to the traditional wash-coating methods used for activating monoliths. The l-PPI monolithic contractor is targeted for use in DAC systems such as the Global Thermostat DAC process, which involves the cyclic operation of ambient air flow over a monolithic amine contactor followed by steam-mediated thermal desorption and CO 2 collection, maximizing volumetric productivity while reducing the auxiliary power required to capture CO 2 from air. The Global Thermostat DAC process currently utilizes poly(ethyleneimine) (PEI) materials as baseline sorbents, which are subject to oxidative degradation and slow capacity fade at the elevated temperature required for efficient CO 2 removal. Georgia Tech, with Global Thermostat, had discovered in lab-scale efforts that l-PPI had superior resistance to oxidative degradation compared to PEI, with similar CO 2 adsorption capacity. While the novel l-PPI sorbent offers significant advantages over PEI for DAC, including potential design simplification and increased process efficiency, it is not commercially available, and prior to this project, had not yet been evaluated on the bench-scale in a structured contactor.

36 MATERIALS SCIENCE↗

Water vapor recovery from plant growth chambers

NASA is investigating the use of plant growth chambers (PGCs) for space missions and for bases on the moon and Mars. Key to successful development of PGCs is a system to recover and reuse the water vapor that is transpired from the leaves of the plants. A design is presented for a simple, reliable, membrane-based system that allows the recovery, purification, and reuse of the transpired water vapor through control of temperature and humidity levels in PGCs. The system is based on two membrane technologies: (1) dehumidification membrane modules to remove water vapor from the air, and (2) membrane contactors to return water vapor to the PGC (and, in doing so, to control the humidity and temperature within the PGC). The membrane-based system promises to provide an ideal, stable growth environment for a variety of plants, through a design that minimizes energy usage, volume, and mass, while maximizing simplicity and reliability.

Ray, R. J.↗