Search NASA⌕ Search

SEARCH · Search NASA

Results for “control logic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Fuzzy logic control system to provide autonomous collision avoidance for Mars rover vehicle

NASA is currently involved with planning unmanned missions to Mars to investigate the terrain and process soil samples in advance of a manned mission. A key issue involved in unmanned surface exploration on Mars is that of supporting autonomous maneuvering since radio communication involves lengthy delays. It is anticipated that specific target locations will be designated for sample gathering. In maneuvering autonomously from a starting position to a target position, the rover will need to avoid a variety of obstacles such as boulders or troughs that may block the shortest path to the target. The physical integrity of the rover needs to be maintained while minimizing the time and distance required to attain the target position. Fuzzy logic lends itself well to building reliable control systems that function in the presence of uncertainty or ambiguity. The following major issues are discussed: (1) the nature of fuzzy logic control systems and software tools to implement them; (2) collision avoidance in the presence of fuzzy parameters; and (3) techniques for adaptation in fuzzy logic control systems.

Murphy, Michael G.↗

Fuzzy Logic Controller for Low Temperature Application

The most common temperature controller used in low temperature experiments is the proportional-integral-derivative (PID) controller due to its simplicity and robustness. However, the performance of temperature regulation using the PID controller depends on initial parameter setup, which often requires operator's expert knowledge on the system. In this paper, we present a computer-assisted temperature controller based on the well known.

proportional-integral-derivative controller PID fu↗

Signal Temporal Logic Control for Residential HVAC Systems to Accommodate High Solar PV Penetration

This paper proposes a new signal temporal logic (STL) control for ON/OFF residential buildings' Heating Ventilation and Air Conditioning (HVAC) systems. STL is used to control indoor temperatures while consuming most of the generated solar photovoltaic (PV) power locally to minimize its impact on the grid and reduce the need for large energy storage devices. In contrast to most, if not all, control mechanisms such as the traditional model predictive control (MPC), STL control allows for including temporal constraints in the control formulation to further relax indoor temperatures' constraints and allow them to exceed the comfort band limits for a prespecified (short) period of time. This relaxation allows to consume an additional PV power by the HVAC systems, which prevents such an unwanted intermittent power from affecting the grid. We formulate the MPC-based STL control mechanism to implement the objective. Simulation results show that the PV tracking performance has been improved while employing the proposed STL controller.

Wu, Tumin↗

Logic-controlled solid-state switchgear for 270 volt dc.

A feasibility study to design and demonstrate solid-state switchgear composed of circuit breakers and a power transfer switch is described. The switchgear operates on a nominal 270 Vdc circuit and controls power to a load up to 15 A. One circuit breaker may be interconnected to a second to form a power transfer switch. Breaker or switch on-off and transfer functions can be remotely controlled. Automatic overload trip-out is provided through an ultimate current trip and an I squared t trip for transient overcurrents lower than the ultimate current trip level. A number of reclosures with variable time delay between trip-out and reclosure are programmed and controlled by integrated analog and COSMOS logic circuits. A commutation circuit that creates minimal transient disturbances to either source or load was developed to interrupt current flow through the main SCR switching element.-

Waddington, D.↗

Logic-controlled solid state switchgear for 270 volts dc

A feasibility study to design and demonstrate solid state switchgear in the form of circuit breakers and a power transfer switch is described. The switchgear operates on a nominal 270 V dc circuit and controls power to a load of up to 15 amperes. One circuit breaker may be interconnected to a second breaker to form a power transfer switch. On-off and transfer functions of the breakers or the transfer switch are remotely controlled. A number of reclosures with variable time delay between tripout and reclosure are programmed and controlled by integrated analog and COSMOS logic circuits. A unique commutation circuit, that generates only minimal transient disturbance to either source or load, was developed to interrupt current flow through the main SCR switching element. Laboratory tests demonstrated performance of the solid state circuit breakers over specified voltage and temperature ranges.

Sundberg, G. R.↗

Grasp Assist Device with Automatic Mode Control Logic

A system includes a glove, sensors, actuator assemblies, and controller. The sensors include load sensors which measure an actual grasping force and attitude sensors which determine a glove attitude. The actuator assembly provides a grasp assist force to the glove. Respective locations of work cells in the work environment and permitted work tasks for each work cell are programmed into the controller. The controller detects the glove location and attitude. A work task is selected by the controller for the location. The controller calculates a required grasp assist force using measured actual grasping forces from the load sensors. The required grasp assist force is applied via the glove using the actuator assembly to thereby assist the operator in performing the identified work task.

Davis, Donald R.↗

Resin transfer molding systems and control logic for manufacturing fiber-reinforced composite parts

Presented are manufacturing control systems for fabricating composite-material structures, methods for making/operating such systems, and resin transfer molding techniques for ameliorating race-tracking effects in fiber-reinforced polymer panels. A method for forming a composite-material construction includes confirming, via a system electronic control unit (ECU), that a fiber-based preform is placed in a mold cavity and that opposing mold segments of the molding apparatus are sealed together. A filler, such as a compressible bladder, a cluster of spring-biased pins, or a spray-chopped fiber bed, is introduced into a void between the fiber-based preform and a tool face of one mold segment to thereby eliminate an unwanted resin race track. The system ECU commands a resin pump to inject resin through a primary gate of the molding apparatus and into the mold cavity to thereby impregnate the fiber-based preform with the resin. One or more vents operate to evacuate air from the mold.

Rodgers, William R.↗

Connected and automated vehicles, driving systems, and control logic for info-rich eco-autonomous driving

A method for controlling automated driving operations of a vehicle includes determining vehicle origin and destination data, and generating a graphical representation of a road network with multiple candidate routes between the vehicle's origin and destination. Road-level data, including speed, turn angle, and/or gradient data, is received for each candidate route, and respective total energy uses are estimated for the vehicle to traverse across the candidate routes. Multiple candidate driving strategies, each having respective speed and acceleration profiles, are determined for the candidate route with the lowest estimated total energy use. An optimal candidate driving strategy is selected through a cost evaluation of the associated speed and acceleration profiles and forward movement simulations of the vehicle over a prediction horizon. Command signals are transmitted to the vehicle's steering and/or powertrain systems to execute control operations based on the optimal driving strategy and the candidate route with the lowest energy use.

Zhao, Junfeng↗

Multiplexed logic controls solar-heating system

Four inexpensive thermocouples monitor temperatures at key points. On command from logic circuitry, dampers open and close to direct airflow, and fan and auxiliary heater shut on or off. Controlling complex arranges heating system in any one of four operating configurations.

Currie, J. R.↗

Fuzzy logic control for camera tracking system

A concept utilizing fuzzy theory has been developed for a camera tracking system to provide support for proximity operations and traffic management around the Space Station Freedom. Fuzzy sets and fuzzy logic based reasoning are used in a control system which utilizes images from a camera and generates required pan and tilt commands to track and maintain a moving target in the camera's field of view. This control system can be implemented on a fuzzy chip to provide an intelligent sensor for autonomous operations. Capabilities of the control system can be expanded to include approach, handover to other sensors, caution and warning messages.

Lea, Robert N.↗

NSLS-II Digital RF Controller Logic and Applications

The National Synchrotron Light Source II (NSLS-II) accelerator consists of the Storage Ring, the Booster Ring and Linac along with their associated cavities. Given the number, types and variety of functions of these cavities, we sought to limit the logic development effort by reuse of parameterized code on one hardware platform. Currently there are six controllers installed in the NSLS-II system. There are two in the Storage ring, two in the Booster ring, one in the Linac and one in the Master Oscillator Distribution system.

43 PARTICLE ACCELERATORS↗

Effect of control logic modifications on airstart performance of F100 engine model derivative engines in an F-15 airplane

A series of airstarts were conducted in an F-15 airplane with two prototype Pratt and Whitney F100 Engine Model Derivative engines equipped with Digital Electronic Engine Control (DEEC) systems. The airstart envelope and the time required for airstarts were defined. Comparisons were made between the original airstart logic, and modified logic which was designed to improve the airstart capability. Spooldown airstarts with the modified logic were more successful at lower altitudes than were those with the original logic. Spooldown airstart times ranged from 33 seconds at 250 knots to 83 seconds at 175 knots. The modified logic improved the airstart time from 31% to 53%, with the most improved times at slower airspeeds. Jet fuel starter (JFS)-assisted airstarts were conducted at 7000 m and airstart times were significantly faster than unassisted airstarts. The effect of altitude on airstart times was small.

Crawford, D. B.↗

Electrically Controlled Logical Switch Based on a Step Yttrium–Iron Garnet Waveguide and a Piezoelectric Actuator

We have demonstrated the possibility of functioning a device based on a spin-wave waveguide containing two channels with different ferrite film thicknesses as a logical switch. For switching states, we have used the dependence of interference type (constructive or destructive) at the output converter common for two channels on the waveguide strain under action of the electrically controlled actuator.

30 DIRECT ENERGY CONVERSION↗

Logic-controlled occlusive cuff system

An occlusive cuff system comprises a pressure cuff and a source of regulated compressed gas feeding the cuff through an electrically operated fill valve. An electrically operated vent valve vents the cuff to the ambient pressure. The fill valve is normally closed and the vent valve is normally open. In response to an external start signal, a logic network opens the fill valve and closes the vent valve, thereby starting the pressurization cycle and a timer. A pressure transducer continuously monitors the pressure in the cuff. When the transducer's output equals a selected reference voltage, a comparator causes the logic network to close the fill valve. The timer, after a selected time delay, opens the vent valve to the ambient pressure, thereby ending the pressurization cycle.

Baker, J. T.↗

Pressurizer dynamic model and emulated programmable logic controllers for nuclear power plants cybersecurity investigations

This work demonstrates the functionality of the pressurizer using a fast-running three regions, non-equilibrium model and control programs of emulated PLCs. The state variables from an integrated model of primary loop in a representative PWR plant are communicated to the pressurizer’s emulated PLCs using a synchronized data transfer function. In turn, the PLCs communicate back instructions to the pressurizer model to adjust the pressure and water level to remain within preprogramed setpoints. Pressurizer model simultaneously solves the coupled mass and energy conservation equations in the saturated vapor and saturated and subcooled liquid regions using fixed step solver. Results demonstrate the response of the pressurizer model linked to an emulated pressure and water level PLCs in a simulated transient involving surge-in and surge-out events. The 50 ms response delay time for the emulated PLC insignificantly affects operation and predictions of the pressurizer model.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Control logic for a 30 cm diameter ion thruster

Tests with a 30 cm thruster having EMT critical components have defined start-up criteria. Of the three phases comprising the start-up mode, the preheat phase is intended to heat critical feed system components to desired temperatures. Of the seven supplies available during the preheat phase, only three were found to be useful for purposes of preheating the thruster. These were the cathode and neutralizer tip heater supplies and the isolator heater supply. If the needed temperatures are attained during preheat, the ignition phase requires only several seconds. The heat phase serves to establish the proper propellant flow rates prior to the transition to the run mode. Using these techniques, a thruster with initial temperatures in the range of -15 to +25 C can be reliably started and provide a 1.0 amp beam within 45 min. High voltage recycle time profiles indicate limitations on several time functions.

Bechtel, R. T.↗