Search NASA⌕ Search

SEARCH · Search NASA

Results for “dispatch optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Optimal Sizing and Dispatch of Solar Power with Storage

Designers of utility-scale solar plants with storage, seeking to maximize some aspect of plant performance, face multiple challenges. In many geographic locations, there is significant penetration of photovoltaic generation, which depresses energy prices during the hours of solar availability. An energy storage system affords the opportunity to dispatch during higher-priced time periods, but complicates plant design and dispatch decisions. Solar resource variability compounds these challenges, because determining optimal system sizes requires simultaneously considering how the plant will be operated under the imposed market and weather conditions. We develop an approach to analyze the economic performance of hybrid and single-technology solar power plants, which incorporates optimal dispatch, and considers the expected electricity market and weather conditions. We utilize the System Advisor Model software package to simulate the operation of multiple renewable generation and energy storage technologies, in conjunction with hourly-fidelity generation decisions determined by a revenue-maximizing, mixed-integer linear program. We show that, under our assumed market and weather conditions, the lifetime benefit-to-cost ratio can be improved by 6 to 19 percent, relative to a baseline design without optimizing, and that a concentrating solar power with thermal energy storage design produces significantly more energy per year, but is less profitable under our cost assumptions.

black-box optimization↗

Time dependent supervisory control update with FARM using rolling window

This report describes improvements to the Feasible Actuator Range Modifier (FARM) component of the RAVEN-based HYBRID framework for analysis of Integrated Energy Systems (IES). FARM supports the HERON plug-in that solves the power dispatch problem. The solution to the dispatch problem involves economically optimal dispatches that satisfy limits on production variables and their rates of variation (explicit constraints) as well as process variables tied to the service life of equipment (implicit constraints). FARM serves to validate or confirm that a HERON solution for explicit constraints also satisfies the implicit constraints. FARM-alpha was released by Argonne National Laboratory in January 2021 followed by FARM-Beta in January 2022 with the latter providing increased flexibility for the user. In this report, FARM-Gamma, the latest version of the code, is described. The major improvement is the implementation of a system identification algorithm based on the Dynamic Mode Decomposition with Control (DMDc) coupled with a “Rolling Window” scheme that allows obtaining linear time-varying state-space models. This feature equips FARM with the most accurate approximation of system dynamics, and it relieves the user from the burden of performing an exhaustive off-line characterization of the dynamics. FARM-Gamma capabilities are assessed by solving the power dispatch problem for a representative IES unit. The simulation times corresponding to the different releases are estimated and compared. These values capture the increasing computational burden of the successively higher fidelity state-space models adopted by FARM-Alpha, FARM-Beta and FARM-Gamma. The code implementation provides significant flexibility, i.e., the user can always select the most suitable version of FARM according to the problem to be solved and the available computational resources. It is anticipated that FARM will play a role in addressing several future IES applications. We outline how it can support the coordinated management and safe operation of a nuclear plant coupled to industrial processes to produce hydrogen and synfuels.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Synthetic Electricity Market Data Generation and HERON Use Case Setup of Advanced Nuclear Reactors Coupled with Thermal Energy Storage Systems

This study evaluates and optimizes advanced nuclear reactors coupled with thermal energy storage (TES) systems in an Integrated Energy System (IES) architecture to enable advanced nuclear power plants (A NPP) to participate in multi-commodity markets, thus enhancing their economic competitiveness. Nuclear-TES coupling scenarios studied herein are designed attenuate the nuclear heat dynamics and defer energy delivery to a later time, enabling the nuclear reactor to continue operating at or near steady-state design conditions as usual while also enabling flexible generation. Three A-NPPs, namely, an advanced light-water reactor (A LWR), a high temperature gas-cooled reactor (HTGR) and a liquid-metal fast reactor (LMFR) were selected as the initial use cases for demonstrating the technoeconomic of thermally balanced energy storage coupling design for thermal power extraction. Each of the reactor technologies were evaluated in two different electricity markets. Stochastic optimization approach was adopted which included the evaluation of price signals from the Pennsylvania-New Jersey-Maryland (PJM) market, and Electric Reliability Council of Texas (ERCOT), using an autoregressive moving average (ARMA) model. Risk Analysis Virtual Environment (RAVEN) tool and its dispatch optimization plugin, the Holistic Energy Resource Optimization Network (HERON), were used to perform dispatch and capacity optimization, using the price data provided by the ARMA models. The results from the Nuclear-TES use cases will be used to design and characterize dynamic integrated system behavior and feedback.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Impact of Spatial Variation in Flexibility on System Operations in Electric Power Systems

With the expansion of renewable energy resources in the electric power systems, having flexibility in the setup will allow to maintain the system's reliability and prevailing operations. Such flexibility can be extracted from utility operated and/or consumer owned devices, such as, storage devices, electric vehicles, etc. For the demand side, generally consumer preferences, incentives, etc. enact on the availability of the flexibility; besides, both the spatial and temporal dimension dictates the degree of the flexibility. Consequently, the optimal dispatch of the grid resources might appear intractable as the considerable amount of flexibility are obliquely stemming from the ungovernable consumer devices. Thus characterizing the consequences of diverged feasible flexibility in the system is crucial for operations. In this paper, a procedure is developed to quantify the degree of flexibility of power systems in terms of resource dispatch reconfiguration. Specifically, we develop optimization problems to attain equivalent resource configurations for the power systems to evaluate the spatial volatility of the network and asses the flexibility of the system. The developed process is then validated using numerical simulations for IEEE-30 bus test system.

Sadnan, Rabayet↗

Control system for multi-system coordination via a single reference governor

This report describes the improvements to the Feasible Actuator Range Modifier (FARM) component of the RAVEN-based HYBRID framework for analysis of Integrated Energy Systems (IES). FARM supports the HERON plug-in that solves the power dispatch problem. The solution involves economically optimal dispatches that satisfy the limits on production variables and corresponding rates of variation (explicit constraints) as well as the limits on the process variables tied to the service life of equipment (implicit constraints). The problem can be addressed as a two-stage process, i.e., HERON power dispatcher estimates a solution that meets explicit constraints (low-resolution physics), whereas FARM uses the simulation outcomes of HYBRID high-fidelity model to capture the system dynamic response and enforce implicit constraints (high-resolution physics). The initial version of the code (FARM-Alpha) was released by Argonne National Laboratory in January 2021 followed by FARM-Beta (January 2022) and FARM-Gamma (April 2022).

42 ENGINEERING↗

Stand-Alone and Hybrid Electric Thermal Energy Storage in the System Advisor Model

This project developed stand-alone electric-thermal energy storage (ETES), stand-alone pumped thermal energy storage (PTES), and hybrid molten-salt power tower (MSPT)-ETES performance and dispatch optimization techno-economic models. The models are available to the public through the System Advisor Model (SAM) software, scripting, and as open-source code. We compared results of the dispatch model to PLEXOS dispatch of a similar generator using the same initial grid pricing signal and found our dispatch model performed well, but closer agreement between the models was limited by the inherent differences between price-taker and unit commitment models. Nevertheless, the price-taker models developed in this project are useful to analyze proposed ETES and PTES technologies because they provide more detailed system and component models, solve several orders of magnitude faster, and are available as free open-source software. The model results represent the most optimistic returns considering grid arbitrage from the input electricity pricing, so the financial results can be applied as a feasibility stage-gate. We also submitted a journal draft paper that describes the ETES dispatch model methodology and demonstrates model functionality. An accepted journal article will serve as peer-reviewed documentation for the models, along with the open-source code, SAM help-menu content, and eventually this final project report.

14 SOLAR ENERGY↗

Multi-Agent Hierarchical Deep Reinforcement Learning for HVAC Control With Flexible DERs

As electricity consumption in commercial and residential buildings continues to rise, reducing energy costs presents an increasing challenge. Heating, ventilating, and air-conditioning (HVAC) systems, which typically account for 40%-50% of a building's energy use, are prime targets for energy savings. Intelligent control of HVAC temperature through the exploitation of HVAC load flexibility brings significant potential to reduce energy consumption and electricity expenses. The nonlinear models of HVAC systems challenge traditional control methods, while the uncertainty introduced by HVAC load flexibility complicates distributed energy resource (DER) management using conventional optimal dispatch techniques. In response to these challenges, we propose a hierarchical multi-agent deep reinforcement learning (DRL) approach. The lower-level agents focus on balancing comfort and energy conservation, while the upper-level DRL agents optimize the use of DERs to reduce peak demand based on the control outcomes of the HVAC by the lower-level agents. Here, in the upper-level agents, we incorporate a multi-agent structure based on ensemble learning, which acts based on historical and current data without relying on precise load forecasting to address the delayed rewarding issue in DRL. This allows for the effective reduction of energy costs. The proposed method is tested using a real-world microgrid comprising 413 buildings in Southern California, and the results demonstrate that our approach can significantly reduce overall electricity bills while ensuring the comfort of consumers and residents.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integrate FARM with PID controllers: IES Simulation Ecosystem Control System Development

The FARM (Feasible Actuator Range Modifier) software module is a component of the RAVEN-based FORCE framework for analysis of Integrated Energy Systems (IES). FARM was designed to support the HERON software module in the solution of the optimal dispatch problem for IES units. As the result of HERON-FARM dispatch simulation, the set-point trajectories are optimized to meet constraints on both the production variables (i.e., the variables to be optimized such as the electrical power, the hydrogen production rate, etc.) and the process variables tied to the service life of equipment (e.g., steam flowrate, vessel pressure, turbine firing temperature, etc.) at a coarse time resolution (every 10 or 100 seconds) over long time horizons (several days or weeks). In case the operational constraints need to be met at finer time resolution, the computational burden of HERON-FARM would linearly increase with the sampling rate, and sub-optimal solutions might be obtained. System responses characterized by overshoots and damped oscillations temporarily violating the imposed constraints might occur during abrupt power transients. In this report, a hierarchical control system architecture for the operation of the Dynamic Energy Technology and Integration Laboratory (DETAIL) facility constructed at INL was proposed. First, the preliminary studies on the proposed control strategy for operating the facility and the designed PI controllers were reviewed. In particular, the current approach for generating the set-point trajectories was studied, and its limits were identified. To this aim, the inclusion of a Supervisory Control layer embedding a modified version of the FARM algorithm for preserving the system safe operation over both long and real-time horizons was proposed. In this way, FARM would be applied twice, i.e., the original version (“FARM Validator”) aiding the solution of the power dispatch problem, and the modified version (“FARM Supervisory” coordinating the PI controllers to address the real-time control tasks. Despite the kernel of the two modules is the same algorithm, their roles, tasks, and capabilities are quite different. A detailed description of the role of FARM at addressing low-level control tasks is provided, along with tentative operational procedures for training the models embedded into the algorithm by using the collected experimental data.

42 ENGINEERING↗

Savings in Action: Lessons from Observed and Modeled Residential Solar Plus Storage Systems

The electric grid is rapidly evolving as small-scale, demand-side resources play increasingly important roles in grid operations and decarbonization. Maximizing the potential of demand-side resources involves incentivizing electricity customers to use those resources in ways that benefit the broader electrical grid. These incentives depend largely on the electricity cost savings that customers can realize from demand-side resource adoption. Determining these potential cost savings is a complex task. Cost savings depend on numerous factors, including the characteristics of different technologies, the algorithms that control these devices, system performance, customer behavior, electricity rate structures, and climatic factors. Another challenge is that estimated cost savings are frequently based on modeled rather than observed system performance, particularly in the academic literature. In this study, we begin to fill the gap in empirical research of demand-side resources using data from a new construction residential community equipped with rooftop solar and storage (S+S) in Arizona. We use these data to analyze the factors that determine customer electricity cost savings and emissions impacts of S+S in the real world. We then compare these data to modeled system performance to understand how models deviate from real-world outcomes. Based on these findings, we explore ways to improve such models and, conversely, use modeled results to suggest improvements to actual S+S deployment. The results of these analyses can be summarized in four key findings: 1) rate structures play a central role in the grid and customer value of demand-side resources; 2) certain customers can benefit more from demand-side resource adoption than others; 3) modeled battery dispatch and sizing reveals opportunities for additional cost savings; and 4) optimal dispatches can reduce grid emissions while maximizing bill savings.

14 SOLAR ENERGY↗

Modern deep neural networks for Direct Normal Irradiance forecasting: A classification approach

The escalating energy demand and the adverse environmental impacts of fossil-fuel use necessitate a shift towards cleaner and renewable alternatives. Concentrated Solar Power (CSP) technology emerges as a promising solution, offering a carbon-free alternative for power generation. The efficiency and profitability of CSP depend on the Direct Normal Irradiance (DNI) component of solar radiation; hence, accurate DNI forecasting can help optimize CSP plants’ operations and performance. The unpredictable nature of weather phenomena, particularly cloud cover, introduces uncertainty into DNI projections. Existing DNI forecasting models use meteorological factors, which are both challenging to estimate numerically over short prediction windows and expensive to model through data at a sufficiently high spatial and temporal resolution. This research addresses the challenge by presenting a novel approach that formulates DNI prediction as a multi-class classification problem, departing from conventional regression-based methods. The primary objective of this classification framework is to identify optimal periods aligning with specific operational thresholds for CSP plants, contributing to enhanced dispatch optimization strategies. We model the DNI classification problem using four advanced deep neural networks – rectified linear unit (ReLU) networks, 1D residual networks (ResNets), bidirectional long short-term memory (BiLSTM) networks, and transformers – achieving accuracies up to 93.5% without requiring meteorological parameters.

14 SOLAR ENERGY↗

Deep-Learning-Based Multi-Timescale Load Forecasting in Buildings: Opportunities and Challenges from Research to Deployment

Electricity load forecasting for buildings and campuses is becoming increasingly important as the penetration of distributed energy resources (DERs) grows. Efficient operation and dispatch of DERs require reasonably accurate predictions of future energy consumption in order to conduct near-real-time optimized dispatch of on-site generation and storage assets. Electric utilities have traditionally performed load forecasting for load pockets spanning large geographic areas, and therefore, forecasting has not been a common practice by buildings and campus operators. Given the growing trends of research and prototyping in the grid-interactive efficient buildings domain, characteristics beyond simple algorithm forecast accuracy are important in determining the algorithm's true utility for smart buildings. Other characteristics include the overall design of the deployed architecture and the operational efficiency of the forecasting system. In this work, we present a deep-learning-based load forecasting system that predicts the building load at 1-hour intervals for 18 hours in the future. We also discuss challenges associated with the real-time deployment of such systems as well as the research opportunities presented by a fully functional forecasting system that has been developed within the National Renewable Energy Laboratory's Intelligent Campus program.

building load forecasting↗

Digital Twin Development for Real Time Optimization

In the real-time optimization operation process of the integrated energy system, digital twin (DT) can support operators to find optimal dispatching strategy. In this research, the DT framework interfacing (external) system-level simulation model, RAVEN, and Python-based optimization framework has been developed. Simple demonstration of finding optimal input values minimizing an objective function with the DT framework has been presented.

25 ENERGY STORAGE↗

Implementation of a feature selection algorithm in FARM to identify important state variables and time-invariant matrices

The FARM (Feasible Actuator Range Modifier) software module is a component of the RAVEN-based FORCE framework for analysis of Integrated Energy Systems (IES). FARM aids the HERON software module in the evaluation of the optimal dispatch for the different IES components. Set-point trajectories are required to meet limits on both production variables (i.e., the variables to be optimized such as the electrical power, the hydrogen production rate, etc.) and process variables tied to the service life of equipment (e.g., steam flowrate, vessel pressure, turbine firing temperature, etc.). To evaluate the feasibility of HERON generated set-points and to do so in an acceptable time, FARM employs reduced order models to represent the dynamic behavior of the systems to be dispatched. These surrogate models take the form of a linear dynamic system with sets of Linear Parameter Varying (LPV) matrices that are mapped to the system operating space. These matrices are derived from the trajectories of system state variables and system output variables during transients. The accuracy of LPV matrices depends on the selection of state variables. In previous reports, state variables were selected by adopting a complicated workflow requiring multiple software licenses and an advanced level of user expertise. In this report, a new workflow that automates the state variable selection process is presented. It significantly reduces the frequency of user interventions and does not require multiple software licenses. Each module in the new workflow is described in detail, and the input / output examples in each step of the workflow are provided. It was demonstrated that this workflow can greatly reduce the complexity of the state variable selection process, and that the updated FARM-Gamma and FARM-Delta validators can benefit from this workflow when solving the power dispatch problem of a representative IES test case. Finally, some code improvements that can further enhance the efficiency are suggested.

42 ENGINEERING↗

Multilevel Analysis, Design, and Modeling of Coupling Advanced Nuclear Reactors and Thermal Energy Storage in an Integrated Energy System

This report discusses the different options for coupling thermal energy storage (TES) systems to advanced nuclear power plants (A-NPPs) in order to enable flexible and hybrid plant operation. An advanced light-water reactor (A LWR), a high-temperature gas-cooled reactor (HTGR) and a liquid-metal fast reactor (LMFR) were selected as the initial use cases for demonstrating a thermally balanced energy storage coupling design for thermal power extraction. The models presented herein showcase several design considerations, focusing on optimal deployment methodologies for achieving steady-state and transient-state operation with minimum disruption to the nuclear power cycle. This first part of the study presents steady-state models developed using Aspen HYSYS®, with the thermal energy bypass for NPP-TES coupling being varied at up to 50%. The various components were sized using the Aspen Process Economic Analyzer (APEA) and Aspen Exchanger Design and Rating (EDR), when applicable. Cost functions from these models were developed using the latest publicly available data obtained from APEA V11. The TES-coupled A-NPP steady-state models and cost functions then provided a baseline for dynamic operation and process optimization by using Idaho National Laboratory (INL)’s Framework for Optimization of Resources and Economics (FORCE) tools. A stochastic optimization of the various energy storage systems coupled to the A-NPPs was then performed using the Risk Analysis Virtual Environment (RAVEN) and its dispatch optimization plugin, the Holistic Energy Resource Optimization Network (HERON). The signal processing and synthetic history capabilities of RAVEN were used to account for the unpredictable behavior of electricity markets. An autoregressive moving average (ARMA) model was used to analyze price signals from the Pennsylvania-New Jersey-Maryland (PJM) market and were applied to the HERON analysis in order to optimize a system with the best economics. Transient modeling evaluation was then performed using Modelica models within the HYBRID repository, which was developed at INL for the Department of Energy Integrated Energy Systems program for the characterization of dynamic integrated system behavior and feedback. This includes evaluation of the TES-coupled A-LWR systems’ impact on physical and thermal system response during imposed system demands. Additional TES-coupled reactor types, coupling approaches, markets, and TES technologies will be evaluated in future work.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Application of FARM to an IES scenario within the FORCE ecosystem

The FARM (Feasible Actuator Range Modifier) software module is a component of the RAVEN-based FORCE framework for analysis of Integrated Energy Systems (IES). FARM supports the HERON software module in the evaluation of the optimal dispatch by evaluating feasible set-points for the different IES unit components. Set-points are required to satisfy limits on both production variables (i.e., the variables to be optimized such as the electrical power, the hydrogen production rate, etc.) and process variables tied to the service life of equipment (e.g., steam flowrate, vessel pressure, turbine firing temperature, etc.). This problem is addressed by adopting a two-stage approach. First, the HERON power dispatcher determines set-points that meet the constraints on the former variables (e.g., power levels and power ramp rate limits). These constraints are called explicit constraints. Then, FARM adjusts these set-points to ensure the respect of the limits on the latter variables given the knowledge of the system physics acquired through machine learning algorithms. These constraints are called implicit constraints. From this standpoint, FARM constitutes a bridge between the HERON power dispatcher that adopts a simplified description of the IES unit (low-resolution physics) and the HYBRID high-fidelity models (high-resolution physics). The original version of the FARM software module (FARM-Alpha) was released by Argonne National Laboratory in January 2021. In the latest version of the code released in July 2022 (FARM-Delta), the Reference Governor (RG) algorithm was upgraded to a Multi-Input Multi-Output version from its original Single-Input Single-Output form. The RG algorithm acts to enforce constraints. With this improvement an IES unit is now treated as a single dynamic system from the standpoint of control. The crosstalk among components in an IES unit is now fully considered thereby ensuring a true optimization is obtained for those units that have multiple set-points. In this report, the capabilities of FARM-Delta operating within the FORCE ecosystem are demonstrated for an IES test case. The specific configuration of IES unit for this case was selected by the IES team with consultation from the Advanced Reactor IES Expert Group. A full TEA analysis that invoked HERON, HYBRID, FARM, and RAVEN was performed and serves to demonstrate how the latest modification to FARM algorithms (i.e., state variable selection, state-space matrices derivation, set-point verification) can shape setpoints that might otherwise compromise the health of equipment through accelerated wear and tear. In this specific test case, it was demonstrated that these algorithms ensure a more efficient utilization of steam resources to be shared by two different subsystems, namely Balance of Plant (BOP) and High-Temperature Steam Electrolysis (HTSE). Finally, some code improvements that can further enhance the user-friendliness are suggested.

97 MATHEMATICS AND COMPUTING↗

Flexible Oxy-Fuel Combustion for High-Penetration Variable Renewables

A thermodynamic model was developed for the oxy-combustion Allam-Fetvedt cycle. This information was then used to develop an optimized dispatch strategy using price strips supplied by the modeling teams. The price strips represent future possible grid configurations that include a high penetration of variable renewables and a carbon tax. Multiple optimization strategies and tools were used to maximize the net present value (NPV) of the plant on these potential future grids. The optimization varied the size of the air separation unit, the size of oxygen storage tanks, the size of carbon dioxide storage tanks and the flow rate of the carbon dioxide pipeline. The team was able to determine a dispatch strategy that resulted in a positive NPV for all price strips. This indicates that an oxy-combustion plant with oxygen storage would be economically viable on a future grid with a high degree of variable renewables.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Tightest Mixed-Integer Programming Formulations for Quadratic SCUC Optimization

In this project, we developed new, tighter Mixed-Integer Programming (MIP) formulations for the combined Alternating Current (AC) Security-Constrained Unit Commitment (SCUC) and Security-Constrained Optimal Power Flow (SCOPF). The work addresses a critical challenge in power system operations: efficiently determining which generation units to commit and how to optimally dispatch them while maintaining network reliability constraints for both normal and contingency scenarios. Our efforts: 1. Advance the Understanding of SCUC/SCOPF Modeling: By introducing tighter MIP formulations and leveraging cutting-edge optimization tools (Julia/JuMP, PowerModels.jl), this project has pushed forward the state of the art in efficient power systems scheduling. 2. Enhance Technical and Economic Feasibility: The methods developed provide more accurate and potentially faster solutions to large-scale, realistic scheduling and dispatch problems in electric power systems, which can translate into improved reliability and potentially lower costs for grid operations. 3. Benefit to the Public: Greater efficiency in power system operations leads to cost savings for utilities and end-users. Improved reliability and integration of advanced modeling approaches can facilitate the adoption of clean energy resources and better accommodate uncertainties in renewable generation. Because this technology could impact bulk power markets and reliability, these innovations have far-reaching public benefits in terms of cost savings, reliability, and sustainability.

24 POWER TRANSMISSION AND DISTRIBUTION↗