Search NASA⌕ Search

SEARCH · Search NASA

Results for “dynamic range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Effect of inoculation with prion dilutions within the dynamic range of ELISA absorbance on prion incubation period

This study examines the effect of various infectious prion titers within the dynamic range as measured by ELISA on incubation period. We inoculated ovinized transgenic mice with seven decreasing dilutions of a fast-incubating scrapie strain. The highest inoculum group was a 20% w/v brain homogenate from a sheep with scrapie. The subsequent six inoculum dilutions ranged from the highest ELISA optical density reading of 4.000 to a dilution where scrapie prions were not detectable by ELISA. Multiple comparison analysis demonstrated variation in the incubation periods between some inoculum groups. Incubation periods were similar between inoculum groups unless their optical density differed by more than ≈2 units of absorbance. These data will inform the interpretation of future studies that compare incubation periods in experimentally inoculated animals for TSE research.

60 APPLIED LIFE SCIENCES↗

Apparatus and method for high dynamic range counting by pixelated detectors

The present disclosure relates to an apparatus and methods for generating a hybrid image by high-dynamic-range counting. In an embodiment, the apparatus includes a processing circuitry configured to acquire an image from a pixelated detector, obtain a sparsity map of the acquired image, the sparsity map indicating low-flux regions of the acquired image and high-flux regions of the acquired image, generate a low-flux image and a high-flux image based on the sparsity map, perform event analysis of the acquired image based on the low-flux image and the high-flux image, the event analysis including detecting, within the low-flux image, incident events by an event counting mode, multiply, by a normalization constant, resulting intensities of the high-flux image and the detected incident events of the low-flux image, and generate the hybrid image by merging the low-flux image and the high-flux image.

Bammes, Benjamin↗

Characterization of a Small-Scale Prototype Detector With Wide Dynamic Range for Time-Resolved High-Energy X-Ray Applications

We present characterization measurements of a fast-framing, wide-dynamic-range x-ray area detector intended for high-energy applications (≥20 keV photons). The MM-PAD-2.1 combines an integrating pixel front-end with a charge-removal mechanism to extend the maximum measurable signal to > 107 20-keV ph/pixel/frame. The charge-removal mechanism is dead-time-less (i.e., incoming signal continues to be integrated by the front-end while charge removal is taking place) up to an incoming photon rate of > 109 20-keV ph/pix/s. A 16×16 pixel prototype was fabricated and characterized using both laboratory and synchrotron x-ray sources, allowing for measurements from single-photon to high-flux conditions. High-flux measurements show linear performance up to ~1010 ph/s in a spot spanning approximately 2×1.5 pixels (FWHM). The onset of temporary radiation damage in the detector was observed during these measurements, manifesting as failure of the digital readout from the detector. These effects were seen to reverse after annealing at 30° C for several hours.

47 OTHER INSTRUMENTATION↗

Characterization of 128 × 128 MM-PAD-2.1 ASIC: a fast framing hard x-ray detector with high dynamic range

Here, we characterize a new x-ray Mixed-Mode Pixel Array Detector (MM-PAD-2.1) Application Specific Integrated Circuit (ASIC). Using an integrating pixel front-end with dynamic charge removal architecture, the MM-PAD-2.1 ASIC extends the maximum measurable x-ray signal (in 20 keV photon units) to > 10 7 x-rays/pixel/frame while maintaining a low read noise across the full dynamic range, all while imaging continuously at a frame rate of up to 10 kHz. The in-pixel dynamic charge removal mechanism prevents saturation of the input amplifier and proceeds in parallel with signal integration to achieve deadtime-less measurements with incident x-ray rates of > 10 10 x-rays/pixel/s. The ASIC format consists of 128 × 128 square pixels each 150 μm on a side and is designed to be 3-side buttable so large arrays can be effectively tiled. Here we use both laboratory x-ray sources and the Cornell High Energy Synchrotron Source (CHESS) to characterize two single ASIC prototype detectors for both low (single x-ray) and high incident flux detection. In the first detector the ASIC was solder bump-bonded to a 500 μm thick Si sensor for efficient detection of x-rays below 20 keV, whereas the second detector used a 750 μm thick CdTe sensor for x-rays above ~20 keV.

36 MATERIALS SCIENCE↗

Large dynamic range digital delay with sub-picosecond precision

Abstract We report on the development and performance of a digitally controlled phase delay with a step of 280 femtoseconds and a dynamic range of 230 picoseconds. Details of the device design and the simulations as well as comparisons with laboratory measurements will be discussed. We describe how we have used this ASIC to stabilize a digital clock to a precision of less than one picosecond.

Instruments & Instrumentation↗

Synchronous digitization for high dynamic range lock-in amplification in beam-scanning microscopy

Digital lock-in amplification (LIA) with synchronous digitization (SD) is shown to provide significant signal to noise (S/N) and linear dynamic range advantages in beam-scanning microscopy measurements using pulsed laser sources. Direct comparisons between SD-LIA and conventional LIA in homodyne second harmonic generation measurements resulted in S/N enhancements consistent with theoretical models. SD-LIA provided notably larger S/N enhancements in the limit of low light intensities, through the smooth transition between photon counting and signal averaging developed in previous work. Rapid beam scanning instrumentation with up to video rate acquisition speeds minimized photo-induced sample damage. The corresponding increased allowance for higher laser power without sample damage is advantageous for increasing the observed signal content.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High Dynamic Range AFM Cantilever With a Collocated Piezoelectric Actuator-Sensor Pair

We present a novel approach to fundamentally eliminate electrical feedthrough (cross-talk) signal in self-sensing piezoelectric microcantilevers, used in dynamic mode atomic force microscopy (AFM). The probe is an Si microcantilever on which a two-layer piezoelectric stack transducer is microfabricated. The top transducer in the stack functions as an actuator, while the bottom transducer is used as a deflection sensor. This arrangement leads to a collocated actuator-sensor pair that co-exist on the same surface area. We report experimental results that establish the sensor's ability to capture the full dynamic range of the cantilever with minimal feedthrough from the actuator.

42 ENGINEERING↗

High framerate and high dynamic range electron microscopy

Methods and systems for acquiring transmission electron microscope video data on a rolling-shutter detector at an enhanced frame rate and without temporal distortions are described. Also described are methods to enhance the dynamic range of image and diffraction data acquired using a transmission electron microscope. The disclosed methods and systems may also be applicable to photon detection and imaging systems.

Bloom, Ruth↗

Dynamic range of atomically thin vibrating nanomechanical resonators

Atomically thin two-dimensional (2D) crystals offer attractive properties for making resonant nanoelectromechanical systems (NEMS) operating at high frequencies. While the fundamental limits of linear operation in such systems are important, currently there is very little quantitative knowledge of the linear dynamic range (DR) and onset of nonlinearity in these devices, which are different than in conventional 1D NEMS such as nanotubes and nanowires. Here, we present theoretical analysis and quantitative models that can be directly used to predict the DR of vibrating 2D circular drumhead NEMS resonators. We show that DR has a strong dependence ∝10log(E{sub Y}{sup 3/2}ρ{sub 3D}{sup -1/2}rtε{sup 5/2}) on device parameters, in which strain ε plays a particularly important role in these 2D systems, dominating over dimensions (radius r, thickness t). This study formulizes the effects from device physical parameters upon DR and sheds light on device design rules toward achieving high DR in 2D NEMS vibrating at radio and microwave frequencies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Picosecond X-ray streak camera dynamic range measurement

Streak cameras are widely used to record the spatio-temporal evolution of laser-induced plasma. A prototype of picosecond X-ray streak camera has been developed and tested by Commissariat à l’Énergie Atomique et aux Énergies Alternatives to answer the Laser MegaJoule specific needs. The dynamic range of this instrument is measured with picosecond X-ray pulses generated by the interaction of a laser beam and a copper target. The required value of 100 is reached only in the configurations combining the slowest sweeping speed and optimization of the streak tube electron throughput by an appropriate choice of high voltages applied to its electrodes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Utilizing multiple state variables to improve the dynamic range of analog switching in a memristor

Memristors and memristive systems have been extensively studied for data storage and computing applications such as neuromorphic systems. To act as synapses in neuromorphic systems, the memristor needs to exhibit analog resistive switching (RS) behavior with incremental conductance change. In this study, we show that the dynamic range of the analog RS behavior can be significantly enhanced in a tantalum-oxide-based memristor. By controlling different state variables enabled by different physical effects during the RS process, the gradual filament expansion stage can be selectively enhanced without strongly affecting the abrupt filament length growth stage. Detailed physics-based modeling further verified the observed experimental effects and revealed the roles of oxygen vacancy drift and diffusion processes, and how the diffusion process can be selectively enhanced during the filament expansion stage. These findings lead to more desirable and reliable memristor behaviors for analog computing applications. Additionally, the ability to selectively control different internal physical processes demonstrated in the current study provides guidance for continued device optimization of memristor devices in general.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Shock initiation of nano-Al/Teflon: High dynamic range pyrometry measurements

In this paper, laser-launched flyer plates (25 μm thick Cu) were used to impact-initiate reactive materials consisting of 40 nm Al particles embedded in Teflon AF polymer (Al/Teflon) on sapphire substrates at a stoichiometric concentration (2.3:1 Teflon:Al), as well as one-half and one-fourth that concentration. A high dynamic range emission spectrometer was used to time and spectrally resolve the emitted light and to determine graybody temperature histories with nanosecond time resolution. At 0.5 km s -1 , first light emission was observed from Teflon, but at 0.6 km s -1 , the emission from Al/Teflon became much more intense, so we assigned the impact threshold for Al/Teflon reactions to be 0.6 (±0.1) km s -1 . The flyer plates produced a 7 ns duration steady shock drive. Emission from shocked Al/Teflon above threshold consisted of two bursts. At the higher impact velocities, the first burst started 15 ns after impact, peaked at 25 ns, and persisted for 75 ns. The second burst started at a few hundred nanoseconds and lasted until 2 μs. The 15 ns start time was exactly the time the flyer plate velocity dropped to zero after impact with sapphire. The first burst was associated with shock-triggered reactions and the second, occurring at ambient pressure, was associated with combustion of leftover material that did not react during shock. The emission spectrum was found to be a good fit to a graybody at all times, allowing temperature histories to be extracted. At 25 ns, the temperature at 0.7 km s -1 and the one-fourth Al load was 3800 K. Those temperatures increased significantly with impact velocity, up to 4600 K, but did not increase as much with Al load. A steady combustion process at 2800 (±100) K was observed in the microsecond range. Finally, the minimal dependence on Al loading indicates that these peak temperatures arise primarily from Al nanoparticles reacting almost independently, since the presence of nearby heat sources had little influence on the peak temperatures.

36 MATERIALS SCIENCE↗

NucD-25 Nuclear Diagnostics Development: NIS capability, Maximizing gamma ray dynamic range, (n,γ) measurements for carbon ρR [Slides]

The LANL Neutron Imaging team is preparing for NIS upgrades and novel capabilities with the advent of consistently higher yields at NIF. Novel scintillators, solid-state detectors, multiplexed imaging detectors, upgraded data acquisition systems, and camera testing are all areas in need of experimental study to further develop imaging capabilities and dynamic range at NIF.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High speed high dynamic range high accuracy measurement system

A measuring system includes an input that emulates a bandpass filter with no signal reflections. A directional coupler connected to the input passes the filtered input to electrically isolated measuring circuits. Each of the measuring circuits includes an amplifier that amplifies the signal through logarithmic functions. The output of the measuring system is an accurate high dynamic range measurement.

47 OTHER INSTRUMENTATION↗

The Mertens Unrolled Network (MU-Net): A High Dynamic Range Fusion Neural Network for Through the Windshield Driver Recognition

Face recognition of vehicle occupants through windshields in unconstrained environments poses a number of unique challenges ranging from glare, poor illumination, driver pose and motion blur. In this paper, we further develop the hardware and software components of a custom vehicle imaging system to better overcome these challenges. After the build out of a physical prototype system that performs High Dynamic Range (HDR) imaging, we collect a small dataset of through-windshield image captures of known drivers. We then reformulate the classical Mertens-Kautz-Van Reeth HDR fusion algorithm as a pre-initialized neural network, which we name the Mertens Unrolled Network (MU-Net), for the purpose of fine-tuning the HDR output of through-windshield images. Reconstructed faces from this novel HDR method are then evaluated and compared against other traditional and experimental HDR methods in a pre-trained state-of-the-art (SOTA) facial recognition pipeline, verifying the efficacy of our approach.

Ruby, Max↗

System and method for high dynamic range waveform digitization

Diverse applications from particle physics experiments to lidar are driving cost and current reduction in giga-hertz sampling rate high-resolution data conversion. Multiple imagers captures a single pixel of data and require processing at very high speed. High-bandwidth high-rate signal sampling, analog-to-digital conversion, and transfer of large amounts of data to a digital data acquisition block are required in such systems. Dynamic range, power consumption, and transfer of high-speed, high-bit width data are key implementation challenges. Data acquisition architectures optimized for specific requirements of such systems may facilitate system implementation and reduce overall system cost.

Mostafanezhad, Isar↗

Shack-Hartmann centroid detection method based on high dynamic range imaging and normalization techniques

In the optical quality measuring process of an optical system, including diamond-turning components, the use of a laser light source can produce an undesirable speckle effect in a Shack-Hartmann (SH) CCD sensor. This speckle noise can deteriorate the precision and accuracy of the wavefront sensor measurement. Here we present a SH centroid detection method founded on computer-based techniques and capable of measurement in the presence of strong speckle noise. The method extends the dynamic range imaging capabilities of the SH sensor through the use of a set of different CCD integration times. The resultant extended range spot map is normalized to accurately obtain the spot centroids. The proposed method has been applied to measure the optical quality of the main optical system (MOS) of the mid-infrared instrument telescope smulator. The wavefront at the exit of this optical system is affected by speckle noise when it is illuminated by a laser source and by air turbulence because it has a long back focal length (3017 mm). Using the proposed technique, the MOS wavefront error was measured and satisfactory results were obtained.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An atomic magnetometer with autonomous frequency stabilization and large dynamic range

The operation of a highly sensitive atomic magnetometer using elliptically polarized resonant light is demonstrated. It is based on measurement of zero magnetic field resonance in degenerate two level systems using polarimetric detection. The transmitted light through the polarimeter is used for laser frequency stabilization, whereas reflected light is used for magnetic field measurement. Thus, the experimental geometry allows autonomous frequency stabilization of the laser frequency leading to compact operation of the overall device and has a preliminary sensitivity of <10 pT/Hz{sup 1/2} @ 1 Hz. Additionally, the dynamic range of the device is improved by feedback controlling the bias magnetic field without compromising on its sensitivity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗