Studies of reaction geometry in oxidation and reduction of the alkaline silver electrode Quarterly report
Reaction geometry in oxidation and reduction of alkaline silver electrodes
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Reaction geometry in oxidation and reduction of alkaline silver electrodes
Reaction geometry in oxidation and reduction of alkaline silver electrode
Increasing the energy storage capability of ionic liquid supercapacitors will require better understanding of ion-electrode interactions. We have probed the influence of these interactions on the structure and differential capacitance of of an ionic liquid ([EMIM][BF4]) at an ideal graphite interface as a function of model accuracy. Of note, differential capacitance is determined through newly derived and validated fluctuation formulas. In terms of model accuracy, we test electrostatic techniques, electrode charging techniques, and electrolyte interatomic potentials. For electrostatic summations, we employ high cost, high fidelity techniques as well as less expensive, approximate techniques for summation in slab geometry. For electrode charging, uniform, constant-charge and environmentally responsive, constant-potential conditions are employed. For the ionic liquid, constant charge and atomically polarizable models are employed. We comment on the role of model accuracy on the structure and energetics of the electric double layer as well as on the magnitude and shape of differential capacitance.
Long-range electric vehicles (EVs) require high-energy-density batteries that also meet the power demands of high current charge and discharge. Ultra-thick (>100 μm) Lithium-ion battery electrodes are critical to enable this need, but slow ion transport in conventional uniform electrodes (UEs) reduces battery capacity at increasing charge/discharge rates. We present a 3D computational analysis on the impact of structured electrode (SE) and graded electrode (GE) geometries on the discharge rate capability of ultra-thick graphite|LiNi 0.6 Mn 0.2 Co 0.2 O 2 (NMC-622) battery cells based on the footprint of a commercial EV pouch cell. SE cathodes with either a “grid” or “line” geometry and GEs with two layers of porosity were modeled. Based on the results of 230 models, we found that the electrolyte volume fraction is a key parameter that impacts capacity improvements in UEs, GEs, and SEs at 2 C–6 C discharge rates. SEs have the greatest discharge rate capability, outperforming GEs and UEs due to reduced Lithium-ion concentration gradients across the electrode thickness, which mitigates electrolyte depletion at high rates. The best SE model has a “grid” geometry with gravimetric and volumetric energy density improvements of 0.9%–4% at C/2–2 C and 18%–24% at 4 C–6 C relative to UEs.
Molybdenum disulfide lubricant film is deposited on two substrates, niobium and nickel-chromium alloys, by means of physical direct-current sputtering. The sputtering system uses a three-electrode /triode/ geometry - a thermionic cathode, an anode, and the target, all enclosed in a vacuum chamber.
Discussion of the various phenomena which affect the available output power of a typical radioisotope thermoelectric generator (RTG), including estimates of the magnitude of these effects. Power degradation, as well as the corresponding changes in operating temperature, are calculated by means of a computer code which systematically accounts for the time- and temperature-dependent variables. A model for predicting available output power of an RTG is developed which includes changes in performance due to fuel decay, alteration of bulk thermoelectric properties, changes in electrode contacts, geometry changes due to material sublimation, and degradation of the thermal insulation.
The use of organic polymers to detect gasses has been known for several years to be an effective means for gas detection via conductivity changes. These chemoresistors offer significant advantages over other gas detectors in that they operate near room temperature and thus can be used in compact, low-power applications.
Electron microscopic studies of reaction geometry in oxidation and reduction of alkaline silver electrodes
An attempt was made to construct an electrochemical system, using iodine, for water purification in Skylab. Data cover measurements of iodine production rates, effect of electrode size and geometry on iodine production rates, and feasibility of using stainless steels as reference electrodes.
Radiofrequency quadrupole (RFQ) linear accelerators with variable aperture cell parameters offer an effective means of accelerating high-intensity ion beams exceeding 100 mA and have been implemented in various RFQ designs. However, in a four-rod RFQ, the use of dielectric perturbation methods to measure the voltage distribution behind the rod electrodes is not applicable when implementing variable aperture geometries, because changes in the rod shape influence the electric field at the location of the perturbation element. Therefore, it was necessary to design the rod profile for each cell such that the electric field distribution behind the rods remains unaffected by changes in the aperture. In this study, we present a method to adjust the voltage distribution by modifying the geometry of the rod electrodes according to each cell's aperture parameters. This design approach enables the integration of variable aperture cells into a four-rod RFQ linac, significantly enhancing the achievable beam current. To ensure uniform capacitance and maintain a constant rod-electrode voltage despite variations in the average aperture radius, we developed a systematic method for shaping the rod electrodes. This method was refined using two-dimensional (2D) and three-dimensional (3D) electromagnetic field simulations to optimize the electrode cross-sectional profiles. The fabricated rod electrodes were then installed in a four-rod RFQ, and the electric field distribution was measured using the perturbation method and tuned by adjusting the base plates. As a result, the measured variation of ±1.1 % confirms that this design methodology can produce a sufficiently uniform voltage distribution for high-current beam acceleration. These results demonstrate the practical feasibility of a variable-aperture four-rod RFQ linac.
The scope of this study is to evaluate the arc start capabilities of various tungsten electrode alloys—2% Thoriated, 2% Ceriated, 2% Lanthanated, and a proprietary Tri-Mix WS2 on Stainless Steel 304 and Molybdenum. Each electrode maintained consistent geometry: 0.040" diameter, 2.000" length, and a 0.0010" flat tip with a 40° tip angle. The testing procedure aimed to determine the minimum starting amperage required to achieve 10 consecutive successful arc starts per electrode type.
Polarization curve of silver anode in ammoniacal electrolyte - Effective electrolytic surface area of sintered silver electrodes - Ultrasonic vibration effects on oxidation of electrode
The present evaluation of the results of arcjet engine lifetime testing attempts to deepen understanding of the electrode erosion process, with a view to its minimization. Attention is given to the compatibility of materials with N2H4, the dependence of electrode erosion on geometry and flow field, and the erosive effects associated with the arcjet power supply. Results are presented for thrusters employing either decomposed N2H4 or cold mixed gases, over a power range of 900 to 2000 W.
Coherent high frequency oscillations near the electron plasma frequency (omega approx. less than omega sub p) are generated by electrodes with positive dc bias immersed in a uniform Maxwellian afterglow plasma. The instability occurs at the sheath-plasma resonance and is driven by a negative RF sheath resistance associated with the electron inertia in the diode-like electron-rich sheath. With increasing dc bias, i.e., electron transit time, the instability exhibits a hard threshold, downward frequency pulling, line broadening and copious harmonics. The fundamental instability is a bounded oscillation due to wave evanescence, but the harmonics are radiated as electromagnetic waves from the electrodes acting like antennas. Wavelength and polarization measurements confirm the emission process. Electromagnetic waves are excited by electrodes of various geometries (planes, cylinders, spheres) which excludes other radiation mechanisms such as orbitrons or beam-plasma instabilities. The line broadening mechanism was identified as a frequency modulation via the electron transit time by dynamic ions. Ion oscillations at the sheath edge give rise to burst-like RF emissions. These laboratory observations of a new instability are important for antennas in space plasmas, generation of coherent beams with diodes, and plasma diagnostics.
Coherent high-frequency oscillations near the electron plasma frequency are generated by electrodes with positive dc bias immersed in a uniform Maxwellian afterglow plasma. The instability occurs at the sheath-plasma resonance and is driven by a negative RF sheath resistance associated with the electron inertia in the diodelike electron-rich sheath. With increasing dc bias, i.e., electron transit time, the instability exhibits a hard threshold, downward frequency pulling, line broadening, and copious harmonics. The fundamental instability is a bounded oscillation caused by wave evanescence, but the harmonics are radiated as electromagnetic waves from the electrodes acting like antennas. Wavelength and polarization measurements confirm the emission process. Electromagnetic waves are excited by electrodes of various geometries (planes, cylinders, spheres), which excludes other radiation mechanisms such as orbitrons or beam-plasma instabilities. The line-broadening mechanism has been identified as a frequency modulation via the electron transit time by dynamic ions. Ion oscillations at the sheath edge give rise to burstlike RF emissions. These laboratory observations of a new instability are important for antennas in space plasmas, generation of coherent beams with diodes, and plasma diagnostics.
To examine momentum redistribution processes and study generalized helicities during plasma relaxation in Madison Symmetric Torus, MST, reversed field pinch plasma, a new probe is being tested to measure the full 3D plasma ion flow and magnetic field vectors at four spatial locations arranged in a tetrahedral shape reminiscent of a satellite measurement constellation. These measurements permit calculation of ∇ x $\vec{u}$ and canonical momentum, where $\vec{u}$ is the plasma ion flow vector. The probe consists of four probe heads arranged in a tetrahedral pattern, with an overall probe diameter of ∼31.75 mm. The probe head diameter is ∼1.0 cm, which is of the order of the ion Larmor radius. Each head has four molybdenum electrodes, also arranged in tetrahedral geometry, which are biased relative to a common return electrode, using four power supplies (one for each head), to measure the local ion flow. Additionally, each head has three orthogonal magnetic pickup coils within it to measure equilibrium and fluctuating magnetic fields.
NASA interest in ionic silver (Ag+) as a biocide for spacecraft potable water systems motivates the development of Ag+ concentration sensors to ensure nominal dosing. The electrolytic conductivity change of highly-purified potable water is linearly related to the concentration of chemically-dosed Ag+ and could serve as a useful proxy measurement, while the conductivity change during electrolytic dosing may be less so, depending on the influent water chemistry and electrolytic efficiency. Understanding and mitigating the potentially deleterious effects of Ag+ interaction with conductivity measurement systems requires investigation. Issues associated with traditional conductivity cells, which rely on wetted(typically metal or graphite) electrodes, and capacitively-coupled contactless conductivity detection (C4D) for this application are considered. Traditional conductivity cells may potentially be subject to significant excitation-induced or auto-galvanic reduction of Ag+. These may result in Ag+ depletion or electrode fouling and associated measurement error. Proper selection of electrode material, excitation parameters, and cell geometry may limit such effects. C4D uses electrodes placed outside an inert, insulating material, with dielectric polarization enabling the production of an electric field and resultant current across the analyte solution. This approach could potentially mitigate problems with Ag+ depletion and fouling by eliminating the possibility of auto-galvanic deposition and reducing the Faradaic current density. However, it is necessary to confirm C4D performance at very low conductivity levels and to determine if long-term operation produces conductive deposits, which could result in measurement error. A commercial C4D system with 1/16” (1.59 mm)outer diameter flow tubing and claimed performance in the conductivity range appropriate for this application was identified, and its sensitivity in the upper parts of this range was confirmed in a preliminary experiment. A concept for a C4D detector that could allow for full rate flow-through using planar electrodes and thin-film dielectric layers is discussed.
Reaction kinetics in oxidation and reduction of alkaline silver electrode