Search NASA⌕ Search

SEARCH · Search NASA

Results for “electron instrument”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

The emulsion chamber technology experiment

Photographic emulsion has the unique property of recording tracks of ionizing particles with a spatial precision of 1 micron, while also being capable of deployment over detector areas of square meters or 10's of square meters. Detectors are passive, their cost to fly in Space is a fraction of that of instruments of similar collecting. A major problem in their continued use has been the labor intensiveness of data retrieval by traditional microscope methods. Two factors changing the acceptability of emulsion technology in space are the astronomical costs of flying large electronic instruments such as ionization calorimeters in Space, and the power and low cost of computers, a small revolution in the laboratory microscope data-taking. Our group at UAH made measurements of the high energy composition and spectra of cosmic rays. The Marshall group has also specialized in space radiation dosimetry. Ionization calorimeters, using alternating layers of lead and photographic emulsion, to measure particle energies up to 10(exp 15) eV were developed. Ten balloon flights were performed with them. No such calorimeters have ever flown in orbit. In the ECT program, a small emulsion chamber was developed and will be flown on the Shuttle mission OAST-2 to resolve the principal technological questions concerning space exposures. These include assessments of: (1) pre-flight and orbital exposure to background radiation, including both self-shielding and secondary particle generation; the practical limit to exposure time in space can then be determined; (2) dynamics of stack to optimize design for launch and weightlessness; and (3) thermal and vacuum constraints on emulsion performance. All these effects are cumulative and affect our ability to perform scientific measurements but cannot be adequately predicted by available methods.

Gregory, John C.↗

Sub-Shot Noise Power Source for Microelectronics

Low-current, high-impedance microelectronic devices can be affected by electric current shot noise more than they are affected by Nyquist noise, even at room temperature. An approach to implementing a sub-shot noise current source for powering such devices is based on direct conversion of amplitude-squeezed light to photocurrent. The phenomenon of optical squeezing allows for the optical measurements below the fundamental shot noise limit, which would be impossible in the domain of classical optics. This becomes possible by affecting the statistical properties of photons in an optical mode, which can be considered as a case of information encoding. Once encoded, the information describing the photon (or any other elementary excitations) statistics can be also transmitted. In fact, it is such information transduction from optics to an electronics circuit, via photoelectric effect, that has allowed the observation of the optical squeezing. It is very difficult, if not technically impossible, to directly measure the statistical distribution of optical photons except at extremely low light level. The photoelectric current, on the other hand, can be easily analyzed using RF spectrum analyzers. Once it was observed that the photocurrent noise generated by a tested light source in question is below the shot noise limit (e.g. produced by a coherent light beam), it was concluded that the light source in question possess the property of amplitude squeezing. The main novelty of this technology is to turn this well-known information transduction approach around. Instead of studying the statistical property of an optical mode by measuring the photoelectron statistics, an amplitude-squeezed light source and a high-efficiency linear photodiode are used to generate photocurrent with sub-Poissonian electron statistics. By powering microelectronic devices with this current source, their performance can be improved, especially their noise parameters. Therefore, a room-temperature sub-shot noise current source can be built that will be beneficial for a very broad range of low-power, low-noise electronic instruments and applications, both cryogenic and room-temperature. Taking advantage of recent demonstrations of the squeezed light sources based on optical micro-disks, this sub-shot noise current source can be made compatible with the size/power requirements specific of the electronic devices it will support.

Strekalov, Dmitry V.↗

Instrument and spacecraft faults associated with nuclear radiation in space

A review is given which surveys the variety of faults and failures which have occurred in space due both to the effects of single, energetic nuclear particles, as well as effects due to the accumulated ionizing dose or the fluence of nuclear particles. The review covers a variety of problems with sensors, electronics, instruments and spacecraft from several countries.

Trainos, J. H.↗

Aquarius Main Structure Configuration

The Aquarius/SAC-D Observatory is a joint US-Argentine mission to map the salinity at the ocean surface. This information is critical to improving our understanding of two major components of Earth's climate system - the water cycle and ocean circulation. By measuring ocean salinity from space, the Aquarius/SAC-D Mission will provide new insights into how the massive natural exchange of freshwater between the ocean, atmosphere and sea ice influences ocean circulation, weather and climate. Aquarius is the primary instrument on the SAC-D spacecraft. It consists of a Passive Microwave Radiometer to detect the surface emission that is used to obtain salinity and an Active Scatterometer to measure the ocean waves that affect the precision of the salinity measurement. The Aquarius Primary Structure houses instrument electronics, feed assemblies, and supports a deployable boom with a 2.5 m Reflector, and provides the structural interface to the SAC-D Spacecraft. The key challenge for the Aquarius main structure configuration is to satisfy the needs of component accommodations, ensuring that the instrument can meet all operational, pointing, environmental, and launch vehicle requirements. This paper describes the evolution of the Aquarius main structure configuration, the challenges of balancing the conflicting requirements, and the major configuration driving decisions and compromises.

Eremenko, Alexander↗

Long range radio tracking of sea turtles and polar bear: Instrumentation and preliminary results

Instrumentation developed for studies of path behavior of the green sea turtle and migration movement of polar bear is described. Preliminary results bearing on navigation ability in these species are presented. Both species operate in difficult environments, and the problems faced in the design of electronic instrumentation for these studies are not completely specified at this time. However, the critical factors yet to be understood are primarily related to the behavior of instrumented animals. The data obtained with these experimental techniques are included, first to illustrate the technique and, second to provide initial preliminary results bearing on animal navigation.

Baldwin, H. A.↗

Ulysses plasma observations in the Jovian magnetosheath

The solar wind plasma experiment aboard the Ulysses spacecraft, including separate ion and electron instruments, measured the plasma properties of the Jovian magnetosheath during the February 1992 encounter with Jupiter. Seven separate magnetosheath intervals were observed, as well as four bow shock crossings and numerous encounters with the magnetopause and its boundary layer. We present an overview of ion and electron bulk parameters and a sampling of distribution shapes for the magnetosheath and adjacent plasma regions. Plasma flows are generally appropriate for slowing and deflection of the solar wind flow about a relatively stationary obstacle, with the notable exception of the first inbound sheath transit, when an expanding magnetosphere resulted in sunward flow just above the magnetopause. The existence of a planetary depletion layer is suggested by trends in plasma density for some magnetopause encounters. The magnetopause boundary layer is characterized by a combination of sheathlike and magnetospheric distributions of both ions and electrons. The ion population in the sheath is observed to include a significant population of suprathermal protons. Electron distributions have a distinctive shape previously observed in the terrestrial magnetosheath, with fluxes parallel to the magnetic field dominating at thermal energies and perpendicular fluxes dominating at higher energies. Trends in electron temperature near the bow shock indicate that shock motion plays an important role in heating the electrons. In general, the plasma characteristics of the Jovian magnetosheath are quite similar to those in its terrestrial counterpart, but the compressible nature of the Jovian magnetosphere accentuates the importance of boundary motions.

Phillips, J. L.↗

Quasi-Steady Acceleration Direction Indicator in Three Dimensions

Many materials processing and fluids physics experiments conducted in a microgravity environment require knowledge of the orientation of the low-frequency acceleration vector. This need becomes especially acute for space experiments such as directional solidification of a molten semiconductor, which is extremely sensitive to orientation and may involve tens of hours of operations of a materials furnace. These low-frequency acceleration data have been measured for many Shuttle missions with the Orbital Acceleration Research Experiment. Previous attempts at using fluid chambers for acceleration measurements have met with limited success due to pointing and vehicle attitude complications. An acceleration direction indicator is described, which is comprised of two orthogonal short cylinders of fluid, each with a small bubble. The motion and the position of the bubble within the chamber will indicate the direction of the acceleration experienced at the sensor location. The direction of the acceleration vector may then be calculated from these data. The frequency response of such an instrument may be tailored for particular experiments with the proper selection of fluid and gas parameters, surface type, and geometry. A three-dimensional system for sensing and displaying the low-frequency acceleration direction via an innovative technique described in this paper has advantages in terms of size, mass, and power compared with electronic instrumentation systems.

DeLombard, Richard↗

Using PEACE Data from the four CLUSTER Spacecraft to Measure Compressibility, Vorticity, and the Taylor Microscale in the Magnetosheath and Plasma Sheet

We present determinations of compressibility and vorticity in the magnetosheath and plasma sheet using moments from the four PEACE thermal electron instruments on CLUSTER. The methodology used assumes a linear variation of the moments throughout the volume defined by the four satellites, which allows spatially independent estimates of the divergence, curl, and gradient. Once the vorticity has been computed, it is possible to estimate directly the Taylor microscale. We have shown previously that the technique works well in the solar wind. Because the background flow speed in the magnetosheath and plasma sheet is usually less than the Alfven speed, the Taylor frozen-in-flow approximation cannot be used. Consequently, this four spacecraft approach is the only viable method for obtaining the wave number properties of the ambient fluctuations. Our results using electron velocity moments will be compared with previous work using magnetometer data from the FGM experiment on Cluster.

Goldstein, Melvyn L.↗

High Yield Xray Imager Final Design Review

The High Yield Xray Imager (HYXI) is a new NIF target diagnostic system currently under development. The goal of HYXI is to provide high-fidelity, high temporal resolution x-ray imaging capability on high yield NIF implosions at 10MJ and above. The HYXI instrument design concept is based on the combination of two technologies that have been successfully utilized at the NIF on previous instruments, electron pulse-dilation and hybrid-CMOS sensor imaging. The combination of these two techniques will give HYXI sufficient data quality to ascertain differences in hot spot formation dynamics between high and low yield implosions. This information will highlight the critical hot spot conditions needed for ignition and burn. The HYXI design leverages the successful operation of the PDIXI x-ray imager at the NIF on multi MJ yield shots. A new radiation tolerant CMOS imaging array (HYPERION) is being developed to eliminate the significant background noise which limits the data quality of PDIXI. We successfully placed the contract with Advanced hCMOS Systems (AHS) to develop the HYPERION sensor, which fulfils our criteria to place long lead time item procurements by end of FY24. The HYXI Final Design Review was completed at the end of Q4 FY24 (Sep 24 th and Sep 30 th ). The HYXI project is a multi-year effort with a phased approach to be bring up system functionality over time in parallel with the development and fabrication effort of the HYPERION CMOS imaging array. In Phase 1, time-integrated x-ray images on NIF DT experiments will be collected starting in Q3 FY25. In Phase 2 of the project, time-resolved imaging with HYXI utilizing a spare microchannel plate detector back-end will begin in Q3 FY26. Phase 3 concludes the project with the installation of the HYPERION sensor array and the final performance qualification of the HYXI instrument which is scheduled for Q3 FY27 as discussed in the PDR and MRT report on this project in FY23.

42 ENGINEERING↗

Milestone report for MRT 8479: High Yield Xray Imager Preliminary Design Review

The High Yield Xray Imager (HYXI) is a new NIF target diagnostic system currently under development. The goal of HYXI is to provide high-fidelity, high temporal resolution x-ray imaging capability on high yield NIF implosions at 10MJ and above. The HYXI instrument design concept is based on the combination of two technologies that have been successfully utilized at the NIF on previous instruments, electron pulse-dilation and hybrid-CMOS sensor imaging. The combination of these two techniques will give HYXI sufficient data quality to ascertain differences in hot spot formation dynamics between high and low yield implosions. This information will highlight the critical hot spot conditions needed for ignition and burn. The HYXI design leverages the successful operation of the PDIXI x-ray imager at the NIF on multi-MJ yield shots. Also, a new radiation tolerance CMOS imaging array is being developed to eliminate the significant background noise which limits the data quality of PDIXI. The HYXI Preliminary Design Review was completed at the end of Q4 FY23. The HYXI project is a multi-year effort with a phased approach to be bring up system functionality over time in parallel with the development and fabrication effort of the new CMOS imaging array. Initial time integrated NIF data will be collected in Q2 FY25, first time resolved imaging with Daedalus starting in Q2 FY26 and the final performance qualification of the complete HYXI system is scheduled for Q2 FY27.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advances in the electron diffraction characterization of atomic clusters and nanoparticles

Nanoparticles and metallic clusters continue to make a remarkable impact on novel and emerging technologies. In recent years, there have been impressive advances in the controlled synthesis of clusters and their advanced characterization. One of the most common ways to determine the structures of nanoparticles and clusters is by means of X-ray diffraction methods. However, this requires the clusters to crystallize in a similar way to those used in protein studies, which is not possible in many cases. Novel methods based on electron diffraction have been used to efficiently study individual nanoparticles and clusters and these can overcome the obstacles commonly encountered during X-ray diffraction methods without the need for large crystals. These novel methodologies have improved with advances in electron microscopy instrumentation and electron detection. Here, we review advanced methodologies for characterizing metallic nanoparticles and clusters using a variety of electron diffraction procedures. These include selected area electron diffraction, nanobeam diffraction, coherent electron diffraction, precession electron diffraction, scanning transmission electron microcopy diffraction, and high throughput data analytics, which leverage deep learning to reduce the propensity for data errors and translate nanometer and atomic scale measurements into material data.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Electronic sleep analyzer

Electronic instrument automatically monitors the stages of sleep of a human subject. The analyzer provides a series of discrete voltage steps with each step corresponding to a clinical assessment of level of consciousness. It is based on the operation of an EEG and requires very little telemetry bandwidth or time.

Frost, J. D., Jr.↗