Proximity sensor technology for manipulator end effectors

Optical proximity sensing techniques which could be used to help control the critical grasping phase of a remote manipulation are described. The proximity sensors described use a triangulation geometry to detect a surface located in a pre-determined region. The design of the proximity sensors themselves is discussed, as well as their application to manipulator control with a local control loop, and possibilities for future development are discussed.

Johnston, A. R.↗

Proximity sensor technology for manipulator end effectors

Optical proximity sensing devices suitable for hand mounting on a manipulator are described, which use near IR LED light sources operating at 0.94 micron and silicon detectors, with appropriate signal processing so that the data are unaffected by ambient light. Laboratory tests with simple proximity sensors are described. Extension of the same techniques to yield multipoint or digital sensors is also discussed. A cooperative proximity sensor concept is described, which employs a composite mirror attached to the work piece to generate an unambiguous set of position and orientation signals. A very rudimentary experiment in local control of a manipulator with a pair of hand mounted proximity sensors is also described.

Johnston, A. R.↗

Gentle End Effector for Robots

Gripper handles electronic components without damaging them. Driven by dc motor, movable jaw gently clamps electronic component. Grips such electronic components as resistors, capacitors, and transistors without damaging them and holds them during soldering or other processing.

Webb, W. S.↗

Precise computer controlled positioning of robot end effectors using force sensors

A major problem in space applications of robotics and docking of spacecraft is the development of technology for automated precise positioning of mating components with smooth motion and soft contact. To achieve the above objective, a design method was developed for optimally placing the closed-loop poles of a discretized robotic control system at exact prescribed locations inside the unit circle of the complex z-plane. The design method combines the merits of the pole placement and the linear quadratic design approaches. The proposed design procedure is based on the assignment of one real eigenvalue or two complex conjugate (or real) eigenvalues at each design step. The method involves solutions of simple algebraic equations and this is considered to be efficient for on-line or off-line computations. Also, two methods for the linearization of the nonlinear model of a robotic manipulator were presented. Since automatic control of multi-degree freedom robotic manipulators involves high nonlinear equations of systems, a pilot project was proposed involving the control of a one-dimensional system. This simple system can be readily implemented for testing the concepts and algorithms.

Shieh, Leang S.↗

Precise computer controlled positioning of robot end effectors using force sensors

A thorough study of combined position/force control using sensory feedback for a one-dimensional manipulator model, which may count for the spacecraft docking problem or be extended to the multi-joint robot manipulator problem, was performed. The additional degree of freedom introduced by the compliant force sensor is included in the system dynamics in the design of precise position control. State feedback based on the pole placement method and with integral control is used to design the position controller. A simple constant gain force controller is used as an example to illustrate the dependence of the stability and steady-state accuracy of the overall position/force control upon the design of the inner position controller. Supportive simulation results are also provided.

Shieh, L. S.↗

Precise computer controlled positioning of robot end effectors using sensory feedback

A preliminary study of the combined position/force control using sensory feedback for a one-dimensional manipulator model, which may count for the spacecraft docking problem or to be extended to the multijoint robot manipulator problem, has been performed. The additional degrees of freedom introduced by the compliant force sensor is included in the system dynamics in the design of precise position control. State feedback based on pole placement method and with integral control is used to design the position controller. A simple constant gain force controller is used as an example to illustrate the dependence of the stability and steady-state accuracy of the overall position/force control on the design of the inner position controller. Supportive simulation results are also provided.

Wang, J. C.↗

Determination of joint drives for stable end-effector motion in flexible robotic systems

The prescribed tasks in high speed robotic systems are severely deteriorated because of their manipulator dynamic deflections. On the other hand conventional dynamic modeling techniques fail to reveal appropriate control forces in flexible systems. The conventional dynamic equations of motion for systems subject to kinematical constraints are modified by a new concept of control force representation. The directions of the control forces are selected such that they correspond to the joint degrees of freedom. Then the joint control forces and torques that yield unperturbed prescribed motions are solved simultaneously with the system motion. A flexible manipulator is presented to illustrate the methods proposed.

Ider, Sitki Kemal↗

Servomotor-Linked Articulated Versatile End Effector (SLAVE2)

A strategy is presented for the design and construction of a large master/slave-controlled, five-finger robotic hand. Each of the five fingers will possess four independent axes each driven by a brushless DC servomotor and, thus, four degrees-of-freedom. It is proposed that commercially available components be utilized as much as possible to fabricate a working laboratory model of the device with an anticipated overall length of approximately three feet (0.9 m). The fingers are to be designed to accommodate proximity, tactile, or force/torque sensors imbedded in their structure. In order to provide for the simultaneous control of the operator wears a specially instrumented glove which produces control signals corresponding to the finger configuration and which is capable of conveying sensor feedback signals to the operator. Two dexterous hand master devices are currently commercially available for this application with both undergoing continuing development.

Ajayi-Majebi, Abayomi J.↗

A study of space-rated connectors using a robotic end-effector

The fabrication and testing of a pair of robot fingers designed to grasp two types of Orbital Replacement Unit (ORU) interfaces, the H Handle type and the Micro Square type are discussed. A closed-form solution is given for the force inverse kinematics. A numerical solution using the Newton-Raphson Method for force forward kinematics is given. Mathematical expressions are derived to compute forces/torques applied to the finger. Suggestions are given for improving finger fabrication. The results of numerous experiments conducted to study the characteristics and feasibility of the fingers are given. The first part of the study was devoted to obtaining data on the forces applied by the finger to the interfaces under various translational and rotational misalignments; the second part was devoted to determining the maximum allowed capture angles that would insure successful mating; and the third part was devoted to the processing and interpretation of the forces/torque data.

Nguyen, Charles C.↗

End effector monitoring system: An illustrated case of operational prototyping

Operational prototyping is introduced to help developers apply software innovations to real-world problems, to help users articulate requirements, and to help develop more usable software. Operational prototyping has been applied to an expert system development project. The expert system supports fault detection and management during grappling operations of the Space Shuttle payload bay arm. The dynamic exchanges among operational prototyping team members are illustrated in a specific prototyping session. We discuss the requirements for operational prototyping technology, types of projects for which operational prototyping is best suited and when it should be applied to those projects.

Malin, Jane T.↗

A study of space-rated connectors using a robot end-effector

The main research activities have been directed toward the study of the Robot Operated Materials Processing System (ROMPS), developed at GSFC under a flight project to investigate commercially promising in-space material processes and to design reflyable robot automated systems to be used in the above processes for low-cost operations. The research activities can be divided into two phases. Phase 1 dealt with testing of ROMPS robot mechanical interfaces and compliant device using a Stewart Platform testbed and Phase 2 with computer simulation study of the ROMPS robot control system. This report provides a summary of the results obtained in Phase 1 and Phase 2.

Nguyen, Charles C.↗

ISS External Microorganisms: A Planetary Protection Experiment to Inform Requirements for Crewed Missions to Mars

We have developed, tested, and flown a caddy capable of collecting aseptic samples from external surfaces of the ISS (International Space Station). The sampling caddy is certified for use during US EVA (extra vehicular activity) and was launched to ISS in the summer of 2023. We are scheduled to collect samples from 6 locations outside ISS during an EVA in May of 2024. We will freeze these samples at -80°C on orbit and return them to Earth. We will then extract and sequence any DNA collected during the EVA using next generation sequencing technologies to characterize the community composition and function of each sample. Measuring the type and quantity of microbes present on the exterior of ISS will allow us to address knowledge gap 2B, “Acceptable levels of microbial/organic releases from humans and support systems” described in a 2019 COSPAR report. Collecting data about microbial release from current crewed vehicles will inform requirements for acceptable leak rates for future crewed missions to Mars. The sampling kit consists of eight commercially available, sterile, DNA free, macrofoam swabs ( 23 mm. diameter ) installed in custom aluminum end effectors. Each end effector is housed in and individual aluminum canister. Each canister contains a 0.2 μm Teflon filter to allow the interior volume to accommodate pressure changes without permitting microbial contaminants to enter the sterile interior volume. A handle repurposed from the space shuttle tile repair kit is used to remove the end effector from the sample canister, collect a sample by swabbing a surface and then replace the end effector in its canister. The canisters and end effectors were cleaned and assembled on Earth. Prior to installing the sterile swab the canisters and end effectors were sterilized in an autoclave at 134°C, 215 kPA, for 7 min.. The final assembly occurred in a sterilized class II biosafety cabinet. We will collect six samples from the 1) airlock vestibule, 2) airlock thermal cover, 3) a gap in the micrometeorite shielding near the airlock, 4) a handrail near the airlock, 5) the CDRA (Carbon Dioxide Removal Assembly) vent, and 6) the VES (Vacuum Exhaust System) vent. The remaining two swabs will be reserved as controls. One swab will be exposed during the EVA without touching any surfaces to act as a blank. The final swab will remain sealed until the entire sampling kit is returned to earth. Based on previously published results from the Russian segment, we hypothesize that there will be detectable microbes at some or all of these locations. Ground-based testing of this sampling caddy confirms that the swabs remain sterile as the canisters transition in and out of vacuum. We were able to retrieve, viable bacterial and fungal cells as well as DNA from samples collected from US space suits during vacuum chamber tests lasting as long as seven hours. Based on these results and feedback from the test subjects the sampling caddy was modified to improve ergonomics and meet US EVA safety requirements. Bayonet probes were added to the sides of the sample kit as alternate mounting points. Additional locking features were added to the end effector and the filter stack to prevent inadvertent release during use. The opening mechanism was changed from one where the end effector was rocked laterally to defeat a ball detent to a twist-to-open threaded closure for similar reasons. Demonstrating, this sampling caddy’s effectiveness during a US EVA will allow us to address knowledge gaps identified in COSPAR reports and begin to define planetary protection requirements for life support systems on crewed missions to mars. This kit could also be used to collect contamination control samples during Artemis missions to verify requirements and could be easily modified for robotic sample collection.

Planetary Protection↗

ISS External Microorganisms: Collecting Planetary Protection Samples During Extravehicular Activity

We have developed, tested, and flown a caddy capable of collecting aseptic samples from external surfaces of the ISS (International Space Station). The sampling caddy is certified for use during US EVA (extra vehicular activity) and was launched to ISS in the summer of 2023. We are scheduled to collect samples from 6 locations outside ISS during an EVA in May of 2024. We will freeze these samples at -80°C on orbit and return them to Earth. We will then extract and sequence any DNA collected during the EVA using next generation sequencing technologies to characterize the community composition and function of each sample. Measuring the type and quantity of microbes present on the exterior of ISS will allow us to address knowledge gap 2B, “Acceptable levels of microbial/organic releases from humans and support systems” described in a 2019 COSPAR report. Collecting data about microbial release from current crewed vehicles will inform requirements for acceptable leak rates for future crewed missions to Mars. The sampling kit consists of eight commercially available, sterile, DNA free, macrofoam swabs ( 23 mm. diameter ) installed in custom aluminum end effectors. Each end effector is housed in and individual aluminum canister. Each canister contains a 0.2 μm Teflon filter to allow the interior volume to accommodate pressure changes without permitting microbial contaminants to enter the sterile interior volume. A handle repurposed from the space shuttle tile repair kit is used to remove the end effector from the sample canister, collect a sample by swabbing a surface and then replace the end effector in its canister. The canisters and end effectors were cleaned and assembled on Earth. Prior to installing the sterile swab the canisters and end effectors were sterilized in an autoclave at 134°C, 215 kPA, for 7 min.. The final assembly occurred in a sterilized class II biosafety cabinet. We will collect six samples from the 1) airlock vestibule, 2) airlock thermal cover, 3) a gap in the micrometeorite shielding near the airlock, 4) a handrail near the airlock, 5) the CDRA (Carbon Dioxide Removal Assembly) vent, and 6) the VES (Vacuum Exhaust System) vent. The remaining two swabs will be reserved as controls. One swab will be exposed during the EVA without touching any surfaces to act as a blank. The final swab will remain sealed until the entire sampling kit is returned to earth. Based on previously published results from the Russian segment, we hypothesize that there will be detectable microbes at some or all of these locations. Ground-based testing of this sampling caddy confirms that the swabs remain sterile as the canisters transition in and out of vacuum. We were able to retrieve, viable bacterial and fungal cells as well as DNA from samples collected from US space suits during vacuum chamber tests lasting as long as seven hours. Based on these results and feedback from the test subjects the sampling caddy was modified to improve ergonomics and meet US EVA safety requirements. Bayonet probes were added to the sides of the sample kit as alternate mounting points. Additional locking features were added to the end effector and the filter stack to prevent inadvertent release during use. The opening mechanism was changed from one where the end effector was rocked laterally to defeat a ball detent to a twist-to-open threaded closure for similar reasons. Demonstrating, this sampling caddy’s effectiveness during a US EVA will allow us to address knowledge gaps identified in COSPAR reports and begin to define planetary protection requirements for life support systems on crewed missions to mars. This kit could also be used to collect contamination control samples during Artemis missions to verify requirements and could be easily modified for robotic sample collection.

Planetary Protection↗

Local Data Processing for a Robot Hand

Integrated-circuit microcomputers process signals among sensors, external controls, and end-effector motor. Multiple-microprocessor system within end effector of remote manipulator accepts data from sensors in end effector, commumnicates with external control system, and controls end-effector motor. External system includes central control computer (which interacts with operator) and display. Local dataprocessing system in end effector relieves external control system of some of its computational load and minimizes data communication load with external higher level controller.

Bejczy, A. K.↗

Experimental study of trajectory planning and control of a high precision robot manipulator

The kinematic and trajectory planning is presented for a 6 DOF end-effector whose design was based on the Stewart Platform mechanism. The end-effector was used as a testbed for studying robotic assembly of NASA hardware with passive compliance. Vector analysis was employed to derive a closed-form solution for the end-effector inverse kinematic transformation. A computationally efficient numerical solution was obtained for the end-effector forward kinematic transformation using Newton-Raphson method. Three trajectory planning schemes, two for fine motion and one for gross motion, were developed for the end-effector. Experiments conducted to evaluate the performance of the trajectory planning schemes showed excellent tracking quality with minimal errors. Current activities focus on implementing the developed trajectory planning schemes on mating and demating space-rated connectors and using the compliant platform to acquire forces/torques applied on the end-effector during the assembly task.

Nguyen, Charles C.↗