Impact of Inverter Based Resource Negative Sequence Current Injection on Transmission System Protection

This report documents the results of analysis performed to investigate the impact of inverter-based resource (IBR) response to unbalanced faults on transmission system protective relay dependability and security. Electromagnetic transient (EMT) simulations were performed to simulate IBR response to these faults using existing manufacturer-developed EMT models for four separate IBRs. The study team was composed of IBR manufacturers, relay manufacturers, transmission providers, reliability coordinators and industry consultants with experience in EMT simulation and system protection. The results indicate that under certain conditions, IBR response can result in protective relay misoperations if current protection practices, which were developed based on conventional power sources, are not adapted to the characteristics of IBRs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Admittance-Based Protection Scheme for Microgrids

This paper presents a novel directional protection scheme to address the unique challenges associated with protection during unbalanced faults in a distribution system with high penetration of inverter-based resources. The scheme is based on a superimposed negative sequence admittance method. A coordination approach using a unique inverse-time undervoltage element is also presented. An analysis of the scheme, the detection criteria and the coordination method are performed. Also the impact of inverter-control on the scheme is discussed. Results from extensive simulation using MATLAB/Simulink are presented to show a selective and reliable response of the scheme to unbalanced faults

Opoku, Kwasi↗

Use of Machine Learning on PMU Data for Transmission System Fault Analysis

Synchrophasor technology has been used for monitoring, control, and protection of bulk power system for over 10 years. Deployment of phasor measurement units (PMUs) in the USA power system has surpassed 3000 units installed in the transmission substations as stand-alone intelligent electronic devices (IEDs) or as a software add-on to other devices such as digital protective relays (DPRs) or digital fault recorders (DFRs). By now, thousands of terabytes of PMU data may have been captured and stored by various transmission system operators (TSOs) and independent system operators (ISOs). This creates an opportunity to deploy advanced machine learning (ML) techniques to detect and classify faults recorded by PMUs automatically to be used by the system operators for rapid, critical decision-making when manual analysis of the past or unfolding events is not feasible. In this paper we offer a brief background on how the automated fault analysis may be done using DPR and/or DFR data, and compare some of the legacy approaches to the new ML approaches in the context of the system-wide PMU recordings. We then offer insights from developing practical ML solutions that have been applied on field recordings captured by close to 450 PMUs from all three US interconnections (Western, Eastern and ERCOT) over two years (2016-2017). We identify and illustrate ML challenges we addressed: inaccurate data, data with scarce and temporally imprecise fault labels, data recorded by PMUs sparsely located at substations resulting in the fault records taken afar from the ends of the faulted lines, data containing only positive sequence values, and data taken at different voltage levels. We then illustrate the ML model results for fault analysis under different application scenarios. The novelty of this study is not only in the design, implementation, and performance analysis of the ML algorithms, but also in the use of advanced fault modelling and simulation approaches to improve the training results when developing supervised ML models for fault detection and classification. Extensive simulations of faults were conducted on a 14-bus power system to create a training dataset with over 1400 accurately labelled faults. This dataset was applied to enhance the accuracy of fault detection and classification of machine learning-based models trained with small number of labelled faults in large datasets recorded in the grid interconnections ranging from 5,000 to 70,000 buses.

Synchrophasors, Machine Learning, Fault Analysis, ↗

Verification of Adaptive Protection in Hardware in the Loop for Coordination with Solar Variability

As inverter-based resources continue to be installed at all levels of the electric grid, the fixed protection schemes used at the distribution level will continue to be stressed until they no longer ensure the protection of the grid. Adaptive protection has been proposed as a solution with the ability to update the protection schemes in near real-time to ensure reliability and increase the resilience of the grid. However, weather variability poses a significant challenge to the ability of these methods to keep the selectivity and reliability of these schemes coordinated. If the ramp rates, due to solar variability, of the inverter-based resources change faster than the adaptive protection can issue new settings, the protection system could be uncoordinated, with the wrong device responding to a system fault. The proposed adaptive protection method ensures that due to solar variability, communication, and protection calculation latency, it can issu e coordinated protection settings promptly, in one minute or less. The hardware-in-the-loop results show the protection settings being issued and maintaining system coordination in under a minute.

Summers, Adam↗

Adaptive Fault Current-Limiting Control of MMC for Protection of Multiterminal HVDC Systems

A crucial requirement of the protection system for multi-terminal high-voltage DC (MTDC) transmission is that it is capable of selectively isolating the faulty area from the healthy part of the network using DC circuit breakers (DCCBs), while ensuring continuous operation of converter stations in the healthy part of the network. But in the half-bridge modular multilevel converters (HB-MMCs) based MTDC system, since HB-MMCs do not have fault current absorption capability, when a DC fault occurs, the rising fault currents can quickly reach the blocking threshold within a few milliseconds and disrupt the operation of the MMCs in the healthy part. To facilitate fault-ride-through capability of MTDC system, large DC reactors are often considered in series with DCCBs to reduce the rate of rise of the fault current and prevent blocking the MMCs in the healthy part of the DC networks; however, large DC reactors prohibitively increase the cost of the system, introduce stability issues and can create post-fault oscillations. This paper presents an adaptive fault current-limiting control method for MMCs to avoid their blocking and enable the continuous operation of the healthy part of MTDC systems. The method contains two parts: The first part is based on circulating current feedforward control, which emulates virtual reactors in each arm of an MMC, and is immediately activated when the fault current starts to increase to reduce the rate of rise of the fault current. The second part temporarily bypasses all the submodules when the fault current exceeds a preset threshold, complementing the fault current-limiting effect of the first part. Neither part requires fault detection signals, and they are automatically activated during faults. Simulation case studies of a four-terminal bipolar MMC-based high-voltage DC system are presented to demonstrate the effectiveness of the proposed control methods.

active fault current limiting↗

A Flexible and Secure Evaluation Platform for Overvoltage Protection in Power Electronics Systems

This paper summarizes the fault mechanisms specifically for the overvoltage protection schemes in power electronic converters and the resulted power electronics enabled systems. A flexible and secure evaluation platform for overvoltage protection, has also been presented based on this conceptual mechanism. The proposed platform aims at testing the protection performance of distinctive overvoltage protection schemes. It would be applied to verify the effectiveness, identify potential strengths and weaknesses, and obtain the most critical protection response time to provide sufficient engineering insights for the designer. The operation principle and detailed design guideline have been presented first. The comprehensive component stress has been analyzed. An intensive set of LTSpice simulations have been conducted to show the validity of the proposed assessment approach.

Zheng, Sheng↗

Hybrid circuit breakers

In one aspect, a hybrid circuit protection device for current-limiting a fault current between a source and a load during a fault is provided. The hybrid circuit protection device includes an input configured to couple to the source, an output configured to couple to the load, a return configured to couple the source to the load, a main switch configured to selectively couple the input to the output, a switching network coupled in parallel with the main switch, and a controller. The controller is configured to determine that the main switch has opened in response to the fault current, where the fault current has an initial value, and activate the switching network to current-limit the fault current to less than the initial value during the fault.

Qi, Li↗

A New High-Impedance-Fault Detection Method to Prevent Power-Line-Induced Wildfires

High Impedance Faults (HIFs) occur when energized power lines come into contact with high impedance ground surfaces, such as tree branches and grassland. HIFs have the potential to cause arcing, leading to vegetation ignition and the initiation of wildfires. The challenge in detecting HIFs comes from the high impedance of the partially conductive materials in contact with the power lines. They create a fault current of low magnitude and traditional protective devices struggle to detect such faults. This paper proposes a novel HIF detection algorithm based upon the analyzed arcing signatures associated with HIFs. The algorithm is evaluated using the Australian Public Bushfire Safety Program (PBSP) dataset. For comparative analysis, a state-of-the-art commercial HIF detection product is also evaluated using the same dataset. The proposed algorithm demonstrates higher detection accuracy over the commercial products with fewer false flags and undetected faults.

grasslands↗

Behavior of Single-Line-Ground Faults in Inverter-Based Resource Dominated Grids Explained

It has been observed by protection engineers that it is difficult for a protective relay to identify the faulted phase during a single-line-ground (SLG) fault in a power system with a high ingression of inverter-based resources (IBR) using currents (phase or sequence). Further studies using electromagnetic transient (EMT) simulation show that the initial operating conditions of the IBRs influence the response of phase currents during an SLG fault. In this letter, we conduct a quantitative analysis using sequence components. We find that the pre-fault condition determines the relative position of the current contributed by the grid versus that from the IBR, and further dictates which phase has the largest magnitude during an SLG condition. Finally, this finding is further verified by the EMT simulation results.

electromagnetic transient simulation↗

Algorithm-Based Fault Tolerance for Convolutional Neural Networks

Convolutional neural networks (CNNs) are becoming more and more important for solving challenging and critical problems in many fields. CNN inference applications have been deployed in safety-critical systems, which may suffer from soft errors caused by high-energy particles, high temperature, or abnormal voltage. Of critical importance is ensuring the stability of the CNN inference process against soft errors. Traditional fault tolerance methods are not suitable for CNN inference because error-correcting code is unable to protect computational components, instruction duplication techniques incur high overhead, and existing algorithm-based fault tolerance (ABFT) techniques cannot protect all convolution implementations. In this paper, we focus on how to protect the CNN inference process against soft errors as efficiently as possible, with the following three contributions. (1) We propose several systematic ABFT schemes based on checksum techniques and analyze their fault protection ability and runtime thoroughly. Unlike traditional ABFT based on matrix-matrix multiplication, our schemes support any convolution implementations. (2) We design a novel workflow integrating all the proposed schemes to obtain a high detection/correction ability with limited total runtime overhead. (3) We perform our evaluation using ImageNet with well-known CNN models including AlexNet, VGG-19, ResNet-18, and YOLOv2. Here, experimental results demonstrate that our implementation can handle soft errors with very limited runtime overhead (4%~8% in both error-free and error-injected situations).

97 MATHEMATICS AND COMPUTING↗

Analysis of Line Distance Elements for Various Ibr Controllers and System Conditions

The large-scale penetration of inverter-based resources in power systems has challenged protection engineers because of the different fault behaviors these sources provide compared to conventional generation systems. The main challenges include a low level of fault current magnitude, unpredictable angles of sequence currents, and lack of inertia that can lead to maloperation of conventional phasor-based protection elements. This paper presents a sensitivity analysis of transmission line distance protection elements during phase-to-ground and phase-to-phase faults for different inverter controllers and power system conditions. It also summarizes which line protection elements remain secure near IBR terminations and identifies the ones affected by the inverter-based response. The paper concludes by highlighting that regulating negative-sequence current injection during the fault aids correct protection decisions, but does not address the entire challenge. Finally, alternative protection elements to those affected by the inverter fault response are discussed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Spread Spectrum Time Domain Reflectivity for String Monitoring in PV Power Plants (Final Technical Report)

This final report describes the methods and results of applying Spread Spectrum Time Domain Reflectivity (SSTDR) for String Monitoring in PV Power Plants for DE-EE0008169. The project created a new system for both detecting and locating electrical faults in photovoltaic systems. In this work, we address photovoltaic electric faults that are both common and costly. Based on interviews with photovoltaic power plant owners, operators, and maintainers, three types of faults are common and of significant interest: disconnects, ground faults, and arc faults. Disconnects can originate from many sources. They are often due to everyday events, such as lawnmowing (accidentally running over a cable), animals eating through the cables, or degradation that occurs over time due to corrosion or general degradation. Ground faults occur when the cables (for example, due to frayed insolation) connect to the ground, relaying current into the ground. These faults are particularly problematic since the ground faults are often intermittent. That is, ground faults commonly appear during rain storms due to a change in soil conductivity and then disappear when the rain ends. This makes the ground fault difficult to find because while current systems can detect the overall change in voltage and current associated with a ground fault, technicians are necessary to locate the fault. As a result, ground faults may disappear before the technician arrives at the power plant. Hence, locating and fixing ground faults often require multiple trips. We also study arc faults, which can result when nearby conductors create an arc of electrical current through the air. While less common, arc faults can be extremely dangerous. The energetic electrical arc can cause fires and destroy equipment, costing significant damage. Overall all three types of faults cost owners and operators money, either from the destruction of equipment or from technician time. Furthermore, while devices exist for detecting ground faults (ground fault circuit interrupters) and arc faults (arc fault circuit interrupter), these systems only search patterns of electrical current that correspond to each fault. This information cannot be used to locate the fault. In addition, these protection systems experience nuisance trips due to nearby electromagnetic interference, such as from a lawn mower or other motors that produce significant amounts of electromagnetic radiation. Hence, the overall goal of this project is to create an SSTDR tool that provides photovoltaic power plants with more reliable fault detection in addition to the localization of faults. SSTDR works by transmitting electrical signals into the photovoltaic string. Those signals reflect from impedance discontinuities (i.e., disconnects, ground faults, and arc faults). These faults are then detected by measuring the presence of a reflection at the SSTDR and can be located by identifying the location of that reflection in time. In addition, unlike current protection systems, these systems do not experience nuisance trips since their low amplitude, high frequency, and coded signal can by analyzed without interference from the regular operational voltage on the photovoltaic string.

14 SOLAR ENERGY↗

Optimization-Based Formulations for Short-Circuit Studies with Inverter-Interfaced Generation in PowerModelsProtection.jl

Protecting inverter-interfaced microgrids is challenging as conventional time-overcurrent protection becomes unusable due to the lack of fault current. There is a great need for novel protective relaying methods that enable the application of protection coordination on microgrids, thereby allowing for microgrids with larger areas and numbers of loads while not compromising reliable power delivery. Tools for modeling and analyzing such microgrids under fault conditions are necessary in order to help design such protective relaying and operate microgrids in a configuration that can be protected, though there is currently a lack of tools applicable to inverter-interfaced microgrids. This paper introduces the concept of applying an optimization problem formulation to the topic of inverter-interfaced microgrid fault modeling, and discusses how it can be employed both for simulating short-circuits and as a set of constraints for optimal microgrid operation to ensure protective device coordination.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hierarchical Data-Driven Protection for Microgrid with 100% Renewable Penetration: Preprint

The accurate detection and isolation of faults is critical for the reliable operation of microgrids (MGs). Traditional protection approaches are even more challenged for 100% renewable MGs because inverter-based resources (IBRs) are the only sources for fault current which are usually low and unpredictable/non-uniform. This calls for new protection scheme that can identify IBR fault responses and detect faults in MGs. Data-driven based protection can learn the pattern of IBR fault responses and make the correct decision to identify faults. Therefore, this paper presents a data-driven approach for fault localization in island MGs. The approach builds a training dataset of comprehensive fault scenarios that can be used to learn fault characteristics from processed measurements. The localization task is modeled as a binary classification problem at each relay, which simplifies the learning process. Then, a hierarchical decision mechanism is used to identify the fault location. The proposed approach is assessed using an exemplary MG with several grid-forming (GFM) and grid-following (GFL) inverters, where accurate estimation of fault location is achieved. The data-driven based protection approach developed in this paper provides a generic framework and useful guidance for power system protection engineers to achieve reliable protection for MGs with 100% renewables.

artificial intelligence↗

Determining quantum phase diagrams of topological Kitaev-inspired models on NISQ quantum hardware

Topological protection is employed in fault-tolerant error correction and in developing quantum algorithms with topological qubits. But, topological protection intrinsic to models being simulated , also robustly protects calculations, even on NISQ hardware. We leverage it by simulating Kitaev-inspired models on IBM quantum computers and accurately determining their phase diagrams. This requires constructing conventional quantum circuits for Majorana braiding to prepare the ground states of Kitaev-inspired models. The entanglement entropy is then measured to calculate the quantum phase boundaries. We show how maintaining particle-hole symmetry when sampling through the Brillouin zone is critical to obtaining high accuracy. This work illustrates how topological protection intrinsic to a quantum model can be employed to perform robust calculations on NISQ hardware, when one measures the appropriate protected quantum properties. It opens the door for further simulation of topological quantum models on quantum hardware available today.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Advanced Sensor Deployment for Distribution System State Estimation and Fault Identification

Distribution systems are currently facing steep operational challenges as a result of the rapidly increasing integration of renewables and other distributed energy resources (DERs) at both the primary and secondary circuit levels. Distribution utilities and system operators have traditionally had some visibility of their primary circuits using low-frequency supervisory control and data acquisition systems, and they have had very poor if not zero visibility of the secondary circuits where the presence of DERs is constantly increasing. Therefore, this paper presents simulation studies to demonstrate the benefits of an advanced, high-fidelity sensor technology, called as the Meta-Alert System (MAS), developed by Electrical Grid Monitoring, Ltd. (EGM), on the distribution grid. First, a reliable model of the EGM sensors is developed, and then two use cases, distribution system state estimation (DSSE) and fault identification are simulated to evaluate the performance of the MAS technology. Simulation results on the Electric Power Research Institute J1 feeder demonstrate that the MAS can effectively participate in system-level DSSE programs and can detect and locate faults faster than traditional distribution protection schemes.

distribution system↗