Search NASA⌕ Search

SEARCH · Search NASA

Results for “field-deployable”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Modular Processing of Flare Gas for Carbon Nanoproducts

This project demonstrated the technical viability and economic promise of a modular system for converting flared natural gas into valuable carbon nanoproducts (CNPs) through catalytic chemical vapor deposition (CVD). All major project milestones were successfully completed, including reactor design and commissioning, catalyst development, process optimization, technoeconomic analysis, and application testing in concrete systems. The overarching goal was to create a scalable, field-deployable process that valorizes stranded methane by producing high-value carbon materials for use in cementitious composites. At the lab scale, the team designed and built a fluidized bed reactor optimized for use with silica fume-supported nickel catalysts synthesized via atomic layer deposition (ALD). A statistically designed sintering study enabled precise tuning of nickel nanoparticle size, identifying the influence of oxygen partial pressure, time, and temperature on catalyst morphology and performance. These insights allowed the team to target catalyst conditions that maximize carbon nanofilament growth. Subsequent CVD experiments achieved up to 31.8 wt% carbon deposition under optimized conditions, with TEM confirming the presence of nanofilament structures and sustained hydrogen evolution during reaction. Reactor upgrades and empirical fluidization studies supported the development of reliable, repeatable experimental protocols. The modular pilot-scale skid reactor was fully constructed, instrumented, and commissioned. Capable of operating at 675–800°C and pressures up to 290 psig, the system was designed for continuous operation at a carbon production rate of 1 kg/hr. Initial demonstration runs confirmed solids handling, thermal control, and system leak-tightness, although a critical reactor component (the downfeed tube) was inadvertently omitted during final assembly. This omission limited gas–solid contact and prevented meaningful carbon deposition during pilot-scale CVD runs. Nonetheless, the system operated safely under design conditions, and the root cause of performance limitations was clearly identified. Complementary work on UHPC formulations demonstrated that small additions of carbon nanoproducts, including those derived from flare gas, can significantly enhance mechanical performance while preserving workability. A comprehensive study of CNF dispersion techniques and mix design optimization led to a clear protocol for integrating these nanomaterials into concrete. Incorporation of CNPs improved flexural toughness and reduced porosity, supporting their use in high-performance infrastructure applications. A technoeconomic analysis (TEA) confirmed that this process can produce CNP-loaded catalyst material at a levelized cost below $\$$7/kg across a range of catalyst loadings and reaction yields. With estimated market values for the carbon composite product ranging from $\$$14 to over $\$$60/kg, and the ability to blend CNPs into concrete at sub-percent levels with less than 10% added cost, the system presents a compelling economic case. While additional engineering work is needed to optimize fluidization and heat transfer at scale, this project establishes a strong foundation for commercial development. The process is not only technically sound but also economically promising, representing a viable pathway for flare gas mitigation through modular carbon nanomaterial production.

03 NATURAL GAS↗

Equipment Assessment Guide: A Technical Inspection and Hardening Guide for Devices in Power Grid Operations

This Equipment Assessment Guide, developed by Idaho National Laboratory (INL), provides a comprehensive framework designed to enhance the security of operational technology (OT) devices within power grid operations. The guide outlines essential steps for asset owners to conduct technical inspections and harden vulnerable hardware and firmware components commonly found in embedded systems. It focuses on components frequently targeted by cyber threats, offering valuable identification techniques for locating and recognizing critical components on devices. Additionally, the guide presents recommended secure configurations aimed at minimizing exposure and reinforcing defenses, along with impact analysis that highlights the potential consequences for grid operations if components are compromised. By implementing the recommendations outlined in this guide, asset owners can significantly enhance their cybersecurity posture, reduce the attack surface of field-deployed devices, and improve the resilience of grid services against emerging cyber threats.

42 - ENGINEERING↗

Casing Annulus Monitoring of CO 2 Injection Using Wireless Autonomous Distributed Sensor Networks

Effective and secure carbon subsurface storage, involving the deep underground injection of CO 2 into geological formations where it is permanently trapped, is paramount to mitigating CO 2 emissions (Figure I). Ensuring the integrity of these storage sites and detecting potential leakage through the casing annulus necessitates robust monitoring. This work provides the first integrated demonstration of a wireless casing-annulus monitoring architecture that can operate in highly attenuating cement-brine environments relevant to CO 2 storage. This project focused on developing and validating a novel sensor system for integration with autonomous monitoring near the cement reservoir interface. The goal was a fully integrated Technology Readiness Level (TRL) 4/5 field validation of a distributed wireless intelligent sensor system providing real-time, direct subsurface formation measurements to enhance fluid movement monitoring in the cemented casing annulus. Achieving this objective required the development and integration of 1) wireless autonomous microsensor technology by California Institute of Technology (Caltech); 2) sensor packaging and emplacement technology by Research Triangle Institute (RTI); and 3) smart well completions using wireless active casing collars and NOV pipe by the Sandia National Lab (SNL). The collaboration with the Caltech team in this project aimed to develop millimeter-scale radio frequency identification (RFID) sensors capable of detecting CO 2 , pH, and/or methane levels. These sensors are engineered to be impervious to fluids, allowing them to be mixed with cement and installed within the casing annulus. They operate using RFID protocols at frequencies of 902–928 MHz for both power and communication. A Sandia National Laboratories’ team engaged their expertise in the development of a Smart Collar system designed for the wireless data collection from these RFID sensors embedded in the cement annulus and transmission of this information to the ground surface via IntelliPipe/IntelliServ NOV drill pipe. This is accomplished through inductive coupling at the collar, which facilitates data transfer through each segment of the pipe. Because the system cannot transmit a direct current signal to power the Smart Collar, both power and communication were implemented using alternating current and electromagnetic signals at varying frequencies. Furthermore, the developed microsensor technology had to be demonstrated and validated in comparison with reference transducer measurements in a field test site at The University of Texas at Austin (UT-Austin). Although the full sensor suite did not reach field-deployment readiness, the system-level integration achieved in this project establishes a validated pathway for future incorporation of advanced microsensors.

47 OTHER INSTRUMENTATION↗

Sensing Techniques for Organochlorides through Intermolecular Interaction with Bicyclic Amidines

Toxic organochloride molecules are widely used in industry for various purposes. With their high volatility, the direct detection of organochlorides in environmental samples is challenging. Here, a new organochloride detection mechanism using 1,5-diazabicyclo[4.3.0]non-5-ene (DBN) is introduced to simplify a sensing method with higher detection sensitivity. Three types of organochloride compounds-trichloroethylene (TCE), dichloromethane (DCM), and dichlorodiphenyltrichloroethane (DDT)—were targeted to understand DCM conjugation chemistry by using nuclear magnetic resonance (NMR) and liquid chromatography with a mass spectrometer (LC-MS). 13C-NMR spectra and LC-MS data indicated that DBN can be labeled on these organochloride compounds by chlorine–nitrogen interaction. Furthermore, to demonstrate the organochloride sensing capability, the labeling yield and limit of detection were determined by a colorimetric assay as well as micellar electrokinetic chromatography (MEKC). The interaction with DBN was most appreciable for TCE, among other organochlorides. TCE was detected at picomolar levels, which is two orders of magnitude lower than the maximum contaminant level set by the United States Environmental Protection Agency. MEKC, in conjunction with this DBN-labeling method, enables us to develop a field-deployable sensing platform for detecting toxic organochlorides with high sensitivity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A new approach for measuring the carbon and oxygen content of atmospherically relevant compounds and mixtures

Abstract. Due to its complexity, gas- and particle-phase organic carbon in the atmosphere is often classified by its bulk physicochemical properties. However, there is a dearth of robust, moderate-cost approaches to measure the bulk chemical composition of organic carbon in the atmosphere. This is particularly true for the degree of oxygenation, which critically affects the properties and impacts of organic carbon but for which routine measurement approaches are lacking. This gap has limited the understanding of a wide range of atmospheric components, including particulate matter, the mass of which is monitored worldwide due to its health and environmental effects but the chemical characterization of which requires relatively high capital costs and complex operation by highly trained technical personnel. In this work, we demonstrate a new approach to estimate the mass of carbon and oxygen in analytes and mixtures that relies only on robust, moderate-cost detectors designed for use with gas chromatography. Organic compounds entering a flame ionization detector were found to be converted with approximately complete efficiency to CO2, which was analyzed downstream using an infrared detector to measure the mass of carbon analyzed. The ratio of the flame ionization detector (FID) signal generated to CO2 formed (FID∕CO2) was shown to be strongly correlated (R2=0.89) to the oxygen-to-carbon ratio (O∕C) of the analyte. Furthermore, simple mixtures of analytes behaved as the weighted average of their components, indicating that this correlation extends to mixtures. These properties were also observed to correlate well with the sensitivity of the FID estimated by structure activity relationships (quantified as the relative effective carbon number). The relationships between measured FID∕CO2, analyte O∕C, and FID sensitivity allow the estimation of one property from another with <15 % error for mixtures and <20 % error for most individual analytes. The approach opens the possibility of field-deployable, autonomous measurement of the carbon and oxygen content of particulate matter using time-tested, low-maintenance detectors, though such an application would require some additional testing on complex mixtures. With some instrumental modifications, similar measurements on gas-phase species may be feasible. Moreover, the potential expansion to additional gas chromatography detectors may provide concurrent measurement of other elements (e.g., sulfur, nitrogen).

42 ENGINEERING↗

Characterization of inexpensive metal oxide sensor performance for trace methane detection

Abstract. Methane, a major contributor to climate change, is emitted by a variety of natural and anthropogenic sources. Commercially available lab-grade instruments for sensing trace methane are expensive, and previous efforts to develop inexpensive, field-deployable trace methane sensors have had mixed results. Industrial and commercial metal oxide (MOx) methane sensors, which are intended for leak detection and safety monitoring, can potentially be repurposed and adapted for low-concentration sensing. As an initial step towards developing a low-cost sensing system, we characterize the performance of five off-the-shelf MOx sensors for 2–10 ppm methane detection in a laboratory setting (Figaro Engineering TGS2600, TGS2602, TGS2611-C00, TGS2611-E00, and Henan Hanwei Electronics MQ4). We identify TGS2611-C00, TGS2611-E00, and MQ4 as promising for trace methane sensing but show that variations in ambient humidity and temperature pose a challenge for the sensors in this application.

54 ENVIRONMENTAL SCIENCES↗

General-Purpose Driver For Arrays Of Photodetectors

Electronic system containing both digital and analog circuits supplies clock waveforms at frequencies up to 12 MHz and/or bias voltages in 16 output channels. Designed to provide low-noise driving signals for any of variety of arrays of photodetectors. Clock waveform and/or bias in each channel adjusted independently of others to suit requirements of specific array of detectors. System offers primary advantage (adjustability) of prior laboratory systems, but at cost, power, and size like those of prior dedicated, field-deployed systems.

Shu, Peter K.↗

High Density Digital Data Storage System

The High Density Digital Data Storage System was designed to provide a cost effective means for storing real-time data from the field-deployable digital acoustic measurement system. However, the high density data storage system is a standalone system that could provide a storage solution for many other real time data acquisition applications. The storage system has inputs for up to 20 channels of 16-bit digital data. The high density tape recorders presently being used in the storage system are capable of storing over 5 gigabytes of data at overall transfer rates of 500 kilobytes per second. However, through the use of data compression techniques the system storage capacity and transfer rate can be doubled. Two tape recorders have been incorporated into the storage system to produce a backup tape of data in real-time. An analog output is provided for each data channel as a means of monitoring the data as it is being recorded.

Wright, Kenneth D., II↗

development of a medium repetition rate (10 Hz - 500 Hz) diode pumped laser transmitter for airborne scanning altimetry

Since the late 1980's, NASA has developed several small, all-solid state lasers of low repetition rates for use as transmitters in prototype LIDAR and raster scanned altimetry retrieval systems. Our early laser transmitters were developed for high resolution airborne altimetry which employed cavity dumping techniques to produce a pulse shape with a 1 ns rise time. The first such laser was the SUMR (Sub-millimeter resolution) transmitter which used a side pumped, D-shaped half-rod of Nd:YAG for the oscillator active media and produced approximately 3 ns pulses of 100 micro-J energy at a 40 Hz repetition rate. (Coyle and Blair, 1993; Coyle et al., 1995) After several upgrades to improve rep rate and pulse energy, the final version produced 1.2 mJ pulses at 120 Hz with a 3.7 ns pulse width. The laser has become known as SPLT (Sharp Pulsed Laser Transmitter), and has flown successfully on a variety of airborne altimetry missions. (Coyle and Blair, 1995; Blair et al., 1994) From building these systems, we have accrued valuable experience in delivering field-deployable lasers and have become aware of the advantages and disadvantages of employing new technologies. For example, even though the laser's main operating environment is in a "cold" aircraft during flight, the laser must still operate in very warm temperatures. This is important if the mission is based in the desert or a tropical climate since ground calibration data from stationary targets must be gathered before and after each data flight. Because conductive cooling is much more convenient than closed loop water flow, achieving the highest possible laser efficiency is becoming a high priority when designing a flight laser. This is especially true for lasers with higher pulse energies and repetition rates which are needed for high altitude scanning altimeters and LIDARs.

Coyle, D. Barry↗

Electrochemically actuated mercury pump for fluid flow and delivery

This paper describes the development of a prototype pumping system with the potential for incorporation into miniaturized, fluid-based analytical instruments. The approach exploits the well-established electrocapillarity phenomena at a mercury/electrolyte interface as the mechanism for pump actuation. That is, electrochemically induced changes in the surface tension of mercury result in the pistonlike movement of a mercury column confined within a capillary. We present herein theoretical and experimental assessments of pump performance. The design and construction of the pump are detailed, and the potential attributes of this design, including the generated pumping pressure, flow rate, and power consumption, are discussed. The possible miniaturization of the pump for use as a field-deployable, fluid-delivery device is also briefly examined.

Non-NASA Center↗

WIND MEASUREMENTS WITH HIGH-ENERGY DOPPLER LIDAR

Coherent lidars at 2-micron wavelengths from holmium or thulium solid-state lasers have been in use to measure wind for applications in meteorology, aircraft wake vortex tracking, and turbulence detection [1,2,3] These field-deployed lidars, however, have generally been of a pulse energy of a few millijoules, limiting their range capability or restricting operation to regions of high aerosol concentration such as the atmospheric boundary layer. Technology improvements in the form of high-energy pulsed lasers, low noise detectors, and high optical quality telescopes are being evaluated to make wind measurements to long ranges or low aerosol concentrations. This research is aimed at developing lidar technology for satellite-based observation of wind on a global scale. The VALIDAR project was initiated to demonstrate a high pulse energy coherent Doppler lidar. VALIDAR gets its name from the concept of validation lidar, in that it can serve as a calibration and validation source for future airborne and spaceborne lidar missions. VALIDAR is housed within a mobile trailer for field measurements.

Koch, Grady J.↗

Phase Calibration of Microphones by Measurement in the Free-field

Over the past several years, significant effort has been expended at NASA Langley developing new Micro-Electro-Mechanical System (MEMS)-based microphone directional array instrumentation for high-frequency aeroacoustic measurements in wind tunnels. This new type of array construction solves two challenges which have limited the widespread use of large channel-count arrays, namely by providing a lower cost-per-channel and a simpler method for mounting microphones in wind tunnels and in field-deployable arrays. The current generation of array instrumentation is capable of extracting accurate noise source location and directivity on a variety of airframe components using sophisticated data reduction algorithms [1-2]. Commercially-available MEMS microphones are condenser-type devices and have some desirable characteristics when compared with conventional condenser-type microphones. The most important advantages of MEMS microphones are their size, price, and power consumption. However, the commercially-available units suffer from certain important shortcomings. Based on experiments with array prototypes, it was found that both the bandwidth and the sound pressure limit of the microphones should be increased significantly to improve the performance and flexibility of the microphone array [3]. It was also desired to modify the packaging to eliminate unwanted Helmholtz resonance s exhibited by the commercial devices. Thus, new requirements were defined as follows: Frequency response: 100 Hz to 100 KHz (+/-3dB) Upper sound pressure limit: Design 1: 130 dB SPL (THD less than 5%) Design 2: 150-160 dB SPL (THD less than 5%) Packaging: 3.73 x 6.13 x 1.3 mm can with laser-etched lid. In collaboration with Novusonic Acoustic Innovation, NASA modified a Knowles SiSonic MEMS design to meet these new requirements. Coupled with the design of the enhanced MEMS microphones was the development of a new calibration method for simultaneously obtaining the sensitivity and phase response of the devices over their entire broadband frequency range. Traditionally, electrostatic actuators (EA) have been used to characterize air-condenser microphones; however, MEMS microphones are not adaptable to the EA method due to their construction and very small diaphragm size [4]. Hence a substitution based, free-field method was developed to calibrate these microphones at frequencies up to 80 kHz. The technique relied on the use of a random, ultrasonic broadband centrifugal sound source located in a small anechoic chamber. The free-field sensitivity (voltage per unit sound pressure) was obtained using the procedure outlined in reference 4. Phase calibrations of the MEMS microphones were derived from cross spectral phase comparisons between the reference and test substitution microphones and an adjacent and invariant grazing-incidence 1/8-inch standard microphone. The free-field calibration procedure along with representative sensitivity and phase responses for the new high-frequency MEMS microphones are presented here.

Shams, Qamar A.↗

Thermal Spray Formation of Polymer Coatings

This innovation forms a sprayable polymer film using powdered precursor materials and an in-process heating method. This device directly applies a powdered polymer onto a substrate to form an adherent, mechanically-sound, and thickness-regulated film. The process can be used to lay down both fully dense and porous, e.g., foam, coatings. This system is field-deployable and includes power distribution, heater controls, polymer constituent material bins, flow controls, material transportation functions, and a thermal spray apparatus. The only thing required for operation in the field is a power source. Because this method does not require solvents, it does not release the toxic, volatile organic compounds of previous methods. Also, the sprayed polymer material is not degraded because this method does not use hot combustion gas or hot plasma gas. This keeps the polymer from becoming rough, porous, or poorly bonded.

Coquill, Scott↗

NASA Tech Briefs, August 2011

Topics covered include: Miniature, Variable-Speed Control Moment Gyroscope; NBL Pistol Grip Tool for Underwater Training of Astronauts; HEXPANDO Expanding Head for Fastener-Retention Hexagonal Wrench; Diagonal-Axes Stage for Pointing an Optical Communications Transceiver; Improvements in Speed and Functionality of a 670-GHz Imaging Radar; IONAC-Lite; Large Ka-Band Slot Array for Digital Beam-Forming Applications; Development of a 150-GHz MMIC Module Prototype for Large-Scale CMB Radiation; Coupling Between Waveguide-Fed Slot Arrays; PCB-Based Break-Out Box; Multiple-Beam Detection of Fast Transient Radio Sources; Router Agent Technology for Policy-Based Network Management; Remote Asynchronous Message Service Gateway; Automatic Tie Pointer for In-Situ Pointing Correction; Jitter Correction; MSLICE Sequencing; EOS MLS Level 2 Data Processing Software Version 3; DspaceOgre 3D Graphics Visualization Tool; Metallization for Yb14MnSb11-Based Thermoelectric Materials; Solvent/Non-Solvent Sintering To Make Microsphere Scaffolds; Enhanced Fuel-Optimal Trajectory-Generation Algorithm for Planetary Pinpoint Landing; Self-Cleaning Coatings and Materials for Decontaminating Field-Deployable Land and Water-Based Optical Systems; Separation of Single-Walled Carbon Nanotubes with DEP-FFF; Li Anode Technology for Improved Performance; Post-Fragmentation Whole Genome Amplification-Based Method; Microwave Tissue Soldering for Immediate Wound Closure; Principles, Techniques, and Applications of Tissue Microfluidics; Robotic Scaffolds for Tissue Engineering and Organ Growth; Stress-Driven Selection of Novel Phenotypes; Method for Accurately Calibrating a Spectrometer Using Broadband Light; Catalytic Microtube Rocket Igniter; Stage Cylindrical Immersive Display; Vacuum Camera Cooler; Atomic Oxygen Fluence Monitor; Thermal Management Tools for Propulsion System Trade Studies and Analysis; Introduction to Physical Intelligence; Technique for Solving Electrically Small to Large Structures for Broadband Applications; Accelerated Adaptive MGS Phase Retrieval; Large Eddy Simulation Study for Fluid Disintegration and Mixing; Tropospheric Correction for InSAR Using Interpolated ECMWF Data and GPS Zenith Total Delay; Technique for Calculating Solution Derivatives With Respect to Geometry Parameters in a CFD Code; Acute Radiation Risk and BRYNTRN Organ Dose Projection Graphical User Interface; Probabilistic Path Planning of Montgolfier Balloons in Strong, Uncertain Wind Fields; Flight Simulation of ARES in the Mars Environment; Low-Outgassing Photogrammetry Targets for Use in Outer Space; Planning the FUSE Mission Using the SOVA Algorithm; Monitoring Spacecraft Telemetry Via Optical or RF Link; and Robust Thermal Control of Propulsion Lines for Space Missions.

Source record↗

Using Advanced Mass Spectrometry Techniques to Fully Characterize Atmospheric Organic Carbon: Current Capabilities and Remaining Gaps

Organic compounds in the atmosphere vary widely in their molecular composition and chemical properties, so no single instrument can reasonably measure the entire range of ambient compounds. Over the past decade, a new generation of in-situ, field-deployable mass spectrometers has dramatically improved our ability to detect, identify, and quantify these organic compounds, but no systematic approach has been developed to assess the extent to which currently available tools capture the entire space of chemical identity and properties that is expected in the atmosphere. Reduced-parameter frameworks that have been developed to describe atmospheric mixtures are exploited here to characterize the range of chemical properties accessed by a suite of instruments. Multiple chemical spaces (e.g. oxidation state of carbon vs. volatility, and oxygen number vs. carbon number) were populated with ions measured by several mass spectrometers, with gas- and particle-phase α-pinene oxidation products serving as the test mixture of organic compounds. Few gaps are observed in the coverage of the parameter spaces by the instruments employed in this work, though the full extent to which comprehensive measurement was achieved is difficult to assess due to uncertainty in the composition of the mixture. Overlaps between individual ions and regions in parameter space were identified, both between gas- and particle-phase measurements, and within each phase. These overlaps were conservatively found to account for little (<10%) of the measured mass. However, challenges in identifying overlaps and in accurately converting molecular formulas into chemical properties (such as volatility or reactivity) highlight a continued need to incorporate structural information into atmospheric measurements.

G. Isaacman-VanWertz↗

An At-Home Evaluation of a Light Intervention to Mitigate Sleep Inertia Symptoms

Introduction: Sleep inertia symptoms typically occur after waking from nocturnal sleep. Under laboratory settings, light exposure upon waking has been shown to improve alertness, mood, and vigilant attention. We investigated whether a field-deployable light-emitting device would help to improve alertness and working memory in a real-world setting. Methods: Thirty-five participants (18 female; 26.4 ± 6.0 y) completed an at-home, within-subject, randomized crossover study. Participants wore actiwatches during their normal sleep-wake schedule for five nights ahead of the adaptation and experimental nights. On the experimental night, participants performed baseline testing before their self-selected bedtime. Forty-five minutes after bedtime, participants received a phone call and were instructed to perform test bouts while wearing light-emitting glasses with the light either on (light condition) or off (control). A 3-minute descending subtraction task (DST) and the Karolinska Sleepiness Scale (KSS) were performed at +7, +17, +27, and +37 minutes after the call. Participants were then instructed to go back to sleep and were called 45 minutes after lights out to repeat the test bouts in the opposite condition. A series of mixed-effects models were performed with fixed effects of condition, test bout, and their interaction, and a random effect of participant. Condition order, sex, and baseline were included as covariates. Results: There was a significant effect of test bout for DST total responses (χ2 [3] = 17.42; p < .001) and total correct (χ2 [3] = 21.29; p < .001) with improved performance at +27 and +37 minutes compared to +7 minutes. Sex was a significant predictor for KSS (F1,30 = 10.26; p = .003), with females (8.20 ± 0.23) rating higher sleepiness than males (7.10 ± 0.25). There were no other significant effects for DST or KSS outcomes (p > .05). Conclusion: These results suggest that the intervention was not able to improve working memory or alertness under naturalistic at-home settings. Further analysis is needed to determine whether these results are applicable to other cognitive performance domains.

light↗

Light as a Reactive Countermeasure to Sleep Inertia: Translating Laboratory Findings to the Field

Sleep inertia describes the brief period of impaired alertness, mood, and cognitive performance experienced after waking. Under laboratory settings, light exposure upon waking during a habitual sleep period has been shown to improve sleep inertia symptoms. We investigated whether a field-deployable light-emitting device would help to mitigate sleep inertia in a real-world setting. Thirty-six participants (18 female; 26.6 years ± 6.1) completed an at-home, within-subject, randomized crossover study. Participants followed their habitual sleep-wake schedule for five nights before an adaptation and experimental night. Forty-five minutes after bedtime on the experimental night, participants received a phone call and were instructed to wear light-emitting glasses with the light either on (light condition) or off (control). A 5-minute psychomotor vigilance task (PVT), the Karolinska Sleepiness Scale (KSS), visual analog scales of mood (VASmood), and a 3-minute descending subtraction task (DST) were performed starting at +2, +12, +22, and +32 minutes after the call. Participants then went back to sleep and were called 45 minutes after lights out for the opposite condition. A series of mixed-effects models were performed with fixed effects of test bout, condition, test bout × condition, and a random effect of participant. Covariates included pre-sleep baseline scores, randomization order, sex, and sleep history. Participants rated themselves as more alert and energetic in the light condition compared to the control condition (VASalert-sleepy p = .01; VASlethargic-energetic p = .001). There was no effect of condition for DST outcomes, but there was a significant improvement in DST total responses in the light condition in a subset of participants waking from N3 (p = .03). There was a significant effect of condition for PVT outcomes, with faster responses (p < .001) and fewer lapses (p < .001) in the control condition. Our results under naturalistic at-home settings suggest that, similar to the in-laboratory study findings, the light intervention improved subjective alertness and mood, while working memory improved after waking from N3. Future studies of light interventions should include measures of visual acuity and comfort to assess the full feasibility and efficacy of interventions in real-world environments.

sleep inertia↗

Light as a Reactive Countermeasure to Sleep Inertia: Translating Laboratory Findings to the Field

Sleep inertia describes the brief period of impaired alertness, mood, and cognitive performance experienced after waking. Under laboratory settings, light exposure upon waking during a habitual sleep period has been shown to improve sleep inertia symptoms. We investigated whether a field-deployable light-emitting device would help to mitigate sleep inertia in a real-world setting.\ Thirty-six participants (18 female; 26.6 years ± 6.1) completed an at-home, within-subject, randomized crossover study. Participants followed their habitual sleep-wake schedule for five nights before an adaptation and experimental night. Forty-five minutes after bedtime on the experimental night, participants received a phone call and were instructed to wear light-emitting glasses with the light either on (light condition) or off (control). A 5-minute psychomotor vigilance task (PVT), the Karolinska Sleepiness Scale (KSS), visual analog scales of mood (VASmood), and a 3-minute descending subtraction task (DST) were performed starting at +2, +12, +22, and +32 minutes after the call. Participants then went back to sleep and were called 45 minutes after lights out for the opposite condition. A series of mixed-effects models were performed with fixed effects of test bout, condition, test bout × condition, and a random effect of participant. Covariates included pre-sleep baseline scores, randomization order, sex, and sleep history. Participants rated themselves as more alert and energetic in the light condition compared to the control condition (VASalert-sleepy p = .01; VASlethargic-energetic p = .001). There was no effect of condition for DST outcomes, but there was a significant improvement in DST total responses in the light condition in a subset of participants waking from N3 (p = .03). There was a significant effect of condition for PVT outcomes, with faster responses (p < .001) and fewer lapses (p < .001) in the control condition. Our results under naturalistic at-home settings suggest that, similar to the in-laboratory study findings, the light intervention improved subjective alertness and mood, while working memory improved after waking from N3. Future studies of light interventions should include measures of visual acuity and comfort to assess the full feasibility and efficacy of interventions in real-world environments.

sleep inertia↗