Search NASA⌕ Search

SEARCH · Search NASA

Results for “fixtures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Fixture For Mounting A Pressure Sensor

Fixture for mounting pressure sensor in aerodynamic model simplifies task of removal and replacement of sensor in event sensor becomes damaged. Makes it unnecessary to dismantle model. Also minimizes any change in aerodynamic characteristics of model in event of replacement. Removable pressure sensor installed in fixture in wall of model. Wires from sensor pass through channel under surface.

Cagle, Christopher M.↗

Flight-Test Fixture For Aerodynamic Research

Second-generation flight-test fixture (FTF-II) developed to be used as generic test bed for research in aerodynamics and fluid mechanics. Highly instrumented finlike structure mounted on lower fuselage surface of F-15B airplane. Modular configuration makes possible to modify FTF-II to satisfy variety of flight-test requirements. Fixture used at airspeeds up to mach 2.0.

Richwine, David M.↗

Test Fixture for Determination of Energy Absorbing Capabilities of Composite Materials

The present invention provides a fixture for supporting an elongated specimen for crush testing. The fixture comprises a base plate. four guiding rods, a sliding plate, four support rods and two collars. The guiding rods connect to the base plate and extend in a direction substantially perpendicular to the base plate. The sliding plate has linear bearings which encircle the guiding rods and enable translation of the sliding plate along the axis of each guiding rod. The four supporting rods mount to the base plate and also extend in a direction substantially perpendicular to the base plate. Each support rod has a keyway for a wedge which contacts the elongated specimen and holds the specimen in place during crushing. Each collar lies above the sliding plate and holds a pair of support rods on their ends opposite the ends connected to the base plate. A spherical bearing sits on top of the sliding plate and transfers an applied load to the sliding plate, which moves downward and crushes the elongated specimen.

Lavoie, J. Andre↗

In-Flight Vibration Environment of the NASA F-15B Flight Test Fixture

Flight vibration data are analyzed for the NASA F-15B/Flight Test Fixture II test bed. Understanding the in-flight vibration environment benefits design and integration of experiments on the test bed. The power spectral density (PSD) of accelerometer flight data is analyzed to quantify the in-flight vibration environment from a frequency of 15 Hz to 1325 Hz. These accelerometer data are analyzed for typical flight conditions and maneuvers. The vibration data are compared to flight-qualification random vibration test standards. The PSD levels in the lateral axis generally are greater than in the longitudinal and vertical axes and decrease with increasing frequency. At frequencies less than approximately 40 Hz, the highest PSD levels occur during takeoff and landing. Peaks in the PSD data for the test fixture occur at approximately 65, 85, 105-110, 200, 500, and 1000 Hz. The pitch-pulse and 2-g turn maneuvers produce PSD peaks at 115 Hz. For cruise conditions, the PSD level of the 85-Hz peak is greatest for transonic flight at Mach 0.9. From 400 Hz to 1325 Hz, the takeoff phase has the highest random vibration levels. The flight-measured vibration levels generally are substantially lower than the random vibration test curve.

Corda, Stephen↗

Grapple fixture for use with electromagnetic attachment mechanism

An electromagnetic attachment mechanism for use as an end effector of a remote manipulator system. A pair of electromagnets 15A,15B, each with a U-shaped magnetic core with a pull-in coil 34 and two holding coils 35,36 are mounted by a spring suspension system 38,47 on a base plate 25 of the mechanism housing 30 with end pole pieces 21,22 adapted to move through openings in the base plate when the attractive force of the electromagnets is exerted on a strike plate 65 of a grapple fixture 20 affixed to a target object 14. The pole pieces are spaced by an air gap from the strike plate when the mechanism first contacts the grapple fixture. An individual control circuit and power source is provided for the pull-in coil and one holding coil of each electromagnet. A back-up control circuit connected to the two power sources and a third power source is provided for the remaining holding coils. When energized, the pull-in coils overcome the suspension system and air gap and are automatically de-energized when the pole pieces move to grapple and impose a preload force across the grapple interface. A battery back-up 89A,89B is a redundant power source for each electromagnet in each individual control circuit and is automatically connected upon failure of the primary power source. A centerline mounted camera 31 and video monitor 70 are used in cooperation with a target pattern 19 on the reflective surface 67 of the strike plate to effect targeting and alignment.

Monford, Jr., Leo G.↗

Plumbing Fixture for a Microfluidic Cartridge

A fixture has been devised for making the plumbing connections between a microfluidic device in a replaceable cartridge and an external fluidic system. The fixture includes a 0.25-in. (6.35-mm) thick steel plate, to which the cartridge is fastened by two 10-32 thumb screws. The plate holds one plumbing fitting for the inlet and one for the outlet of the microfluidic device. Each fitting includes a fused-silica tube of 0.006-in. (approx.0.15-mm) inside diameter within a fluorinated ethylene-propylene (FEP) tube of 0.0155-in. (approx.0.39-mm) inside diameter and 0.062- in. (approx.1.57-mm) outside diameter. The FEP tube is press-fit through the steel plate so that its exposed end is flush with the surface of the plate, and the silica tube protrudes 0.03 in. (approx.0.76 mm) from the plate/FEP-tube-end surface. The cartridge includes a glass cover plate that contains 0.06-mm-wide access ports. When the cartridge is fastened to the steel plate, the silica tubes become inserted through the access ports and into the body of the cartridge, while the ends of the FEP tubes become butted against the glass cover plate. An extremely tight seal is thereby made.

Francis, Kevin↗

Combined Load Test Fixture

A test fixture has been developed at NASA Langley Research Center that has the capability of applying compression load and shear load simultaneously to a test specimen. The test specimen size is 24-inches by 28-inches. This report describes the test specimen design, test specimen preparation, fixture assembly in the test machine, and a test operation plan.

Baker, Donald J.↗

Wire Test Grip Fixture

Wire-testing issues, such as the gripping strains imposed on the wire, play a critical role in obtaining clean data. In a standard test frame fitted with flat wedge grips, the gripping action alone creates stresses on the wire specimen that cause the wire to fail at the grip location. A new test frame, which is outfitted with a vacuum chamber, negated the use of any conventional commercially available wire test fixtures, as only 7 in. (17.8 cm) existed between the grip faces. An innovative grip fixture was designed to test thin gauge wire for a variety of applications in an existing Instron test frame outfitted with a vacuum chamber.

Burke, Christopher S.↗

Optimization Approach for Wind Tunnel Fan Blade Strain Gage Correlation with Test Fixture Unknowns

NASA has a significant maintenance challenge with the aging wind tunnel infrastructure across the Agency. Some wind tunnel fan blades, such as those in the National Transonic Facility at NASA Langley Research Center, have been in use for far longer than their planned 10-year lifetime. No detailed analytical models of the fan blades from their initial fabrication were created. To support the fabrication of either new, nominally identical fan blades or newly designed fan blades, accurate analytical models of the existing fan blades are necessary to demonstrate an understanding of the capabilities of the existing fan blades. Additionally, the existing documentation of the testing of the existing fan blades has gaps. In this report, a process for improving test-analysis correlation for these wind tunnel fan blades is discussed. This process involved a detailed study of unknown parameters in test fixture parameters from the old and incomplete test documentation. To improve correlation, these unknown parameters were used as design variables in an optimization study to minimize the error between test data and computed structural responses. Legacy strain gage data from tests conducted in 1981 were compared with results from a finite element model created in 2019. The use of test data from 1981 was necessary because none of the existing fan blades could be spared for use in destructive structural testing. While this process was demonstrated for wind tunnel fan blades, this process could be utilized for evaluating unknowns in test fixtures for other structural test configurations.

wind tunnel↗

Jig and fixture aid fabrication of tungsten rivets

Jig and fixture that holds several lengths of tungsten rods produces rivets simply and inexpensively. The apparatus allows sufficient tungsten to be exposed for heating and forging into a rivet head.

Chattin, J. H.↗

Spiral heater coils hand-formed with fixture

Bench model jig and fixture used for hand fabricating spiral coils of various lengths from flat strip stock. This tool is used to make springs and coils to custom lengths.

Chattin, J. H.↗

Fixture aids soldering of electronic components on circuit board

Spring clamp fixture holds small electronic components in a desired position while they are being soldered on a circuit board. The spring clamp is clipped on the edge of the circuit board and an adjustable spring-steel boom holds components against the board. The felt pad at the end of the boom is replaced with different attachments for other holding tasks.

Ross, M. H.↗

Vacuum test fixture improves leakage rate measurements

Cylindrical chamber, consisting of two matching halves, forms a vacuum test fixture for measuring leakage rates of individual connections, brazed joints, and entrance ports used in closed fluid flow line systems. Once the chamber has been sufficiently evacuated, atmospheric pressure holds the two halves together.

Maier, H.↗

Holding fixture facilitates pipe thread gage measurements

Holding fixture that holds the thread gage and three wires in the proper relationship facilitates the measurement of the pitch diameter of the tapered threads of a pipe thread gage. Modified, this device can be used to hold involute spur gears.

Cupps, B.↗

Portable fixture facilitates pressure testing of instrumentation fittings

Portable fixture facilitates pressure testing to detect possible leaks in instrumentation fittings mounted on tank bulkheads. It uses a vacuum cup which seals a pressure regulator adapter around one side of the fitting to be pressure tested. Leakage is detected with a gas sniffer.

Olson, G. A.↗