Search NASA⌕ Search

SEARCH · Search NASA

Results for “forensic chemistry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Age determination of a 75 Se gamma radiography source for nuclear forensics

Here, two methods were used to evaluate the age of 75 Se sealed source material. Both methods utilized gamma spectroscopy to determine the quantity of parent 75 Se present, but they differed in the technique used to determine the quantity of daughter 75 As. In one method, 75 As was quantified using inductively coupled plasma-mass spectrometry (ICP-MS) after using chromatographic techniques to separate the parent and daughter isotopes. In the other method, total As was measured using optical emission spectroscopy (OES), which did not require separation prior to measurement. The OES method was faster and gave slightly lower uncertainties, but required more daughter material to be present because of higher concentration requirements, making it unsuitable for young material. Both methods are hampered by the monoisotopic nature of As, but still gave reasonable model ages that were in agreement with each other.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Evaluation of SR/ TEVA/ TRU triple stack for separation of activation products

A rapid method to separate Ta, Po, Au, Pt, and W from a sample containing mixed fission and activation products was developed using three commercially available extraction chromatography resins stacked in series. When the separation was tested using all the target activation products, even those with short half-lives were measurable. Finally, combining multiple extraction chromatography resin cartridges in tandem allows for multiple short-lived activation products to be separated from one sample addition without the complication of multiple steps.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

A new method for quantifying 64 Cu in nuclear debris samples

Quantifying 64 Cu in post-detonation nuclear debris samples can provide important diagnostic information regarding the structural materials used within a nuclear device. However, this task is challenging due to the weak gamma emissions associated with the decay of 64 Cu, its short half-life (12.701 h), and the presence of interfering fission product radioisotopes. Large quantities of debris sample are generally needed to accurately quantify 64 Cu, which can be problematic in sample-limited scenarios where other radiometric analyses are required. Herein, we present a new method for the separation of 64 Cu from solutions of mixed fission products and demonstrate the quantification of its activity through use of gas-flow proportional beta counting. Here, the new method was validated through a series of rigorous tests and was shown to improve the detection limit of 64 Cu by over two orders of magnitude, from 2.5 × 10 6 to 1.3 × 10 4 atoms/sample for 100 min measurements.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Rapid Quantification of 237 U Specific Activity for Nuclear Forensics

In the event of an unattributed nuclear explosion, rapid assessment of the short-lived uranium isotope activity and mass can provide valuable information for subsequent forensic analysis. Rapid analysis in the field is enabled by using microfluidic chemistry and deployable instrumentation. Here, this work presents a flow chemistry system, controlled in LabVIEW, that integrates three functionalities: (1) selective extraction of uranium from the sample matrix via a 3D-printed supported liquid membrane module; (2) UV–visible absorbance spectrophotometry to measure the total uranium concentration in the strip flow; and (3) a portable CdTe γ-ray spectrometer coupled to a 3D-printed flow cell to measure 237 U activity concentration in the strip solution. The system was calibrated using standard solutions, and its functionality was demonstrated using a solution of depleted uranium spiked with 237 U. Uranium concentrations of 40–5000 μg/mL were directly quantified online using a 100 mm optical flow cell, while concentrations of 0.5–10 μg/mL were quantified online using a colorimetric reagent. The mass concentration measurement takes approximately 60 min while the activity concentration via γ-ray spectrometry varies depending on the activity of 237 U, with 1 kBq/mL requiring about 30 min of acquisition time to obtain <10% uncertainty at 1σ. This platform provides a fieldable approach for quantifying uranium mass and radioactivity relevant to postdetonation nuclear debris.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Chemical separation and measurement of platinum activation products

Here, a method has been developed to purify and measure platinum radioisotopes in the presence of fission products and environmental constituents. The method uses a combination of cation exchange and anion exchange chromatography and selective precipitation steps to remove other radioisotopes from the sample. The addition of stable platinum carrier allows for a gravimetric determination of the chemical yield of the procedure. Overall, the method is fast, simple, and potentially applicable for rapid turnaround of unknown samples. Using this method, multiple platinum radioisotopes were measured in two different irradiation experiments. The measured ratios of the platinum radioisotopes clearly reflect the neutron spectrum of the irradiation, suggesting that platinum radioisotopes could be valuable signatures in nuclear forensic analyses.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Radioxenon signatures of molten salt reactors

Developments of molten salt reactor (MSR) technologies are making rapid progress across the globe. These reactor designs involve properly controlling radionuclides through off-gas systems. This work examines radioxenon emissions and assesses treaty detection technology to be used for monitoring. This work also includes a sensitivity study with ORIGEN on the nuclear forensic signals possible from a MSR. Multiple Isotope Ratio Comparison (MIRC) plots are used to compare the ratios of radioxenon isotopes in an MSR to a highly enriched uranium (HEU) reactor. Finally, the results show that MSR emissions may significantly overlap with signals produced in a HEU reactor and that changing reactor operations or retaining emissions in an off-gas system can significantly shift the radioxenon signature away from the HEU pulse.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Ambient Mass Spectrometry Rapid Analysis Methods for Trace Inorganics

The ability to rapidly detect and characterize the chemistry of trace quantities of inorganic species has multiple potential applications, including nuclear safeguards, nuclear forensics, and environmental monitoring. Some mass spectrometric methods currently exist, but they are costly and time-intensive, often destroying chemical information in the process of ionization. Ambient mass spectrometry is a relatively new analytical method in which samples are introduced to the mass spectrometer from atmospheric pressure, rather than from high vacuum. Ambient MS can operate with gentler ionization methods such as electrospray ionization (ESI) and paper-spray ionization (PSI), reducing fragmentation and preserving the chemical information of the analyte. This may be useful for determining the intended purpose of material in a sample. Strontium, part of nuclear fallout, is analyzed here to test these new analytical methods for viability. Electrospray ionization mass spectrometry functions by spraying the sample as a solution through a needle charged to a few kV. A nebulizing gas flows out along with the sample to create the spray before droplets enter a drying chamber with heated drying gas to remove the solvent molecules. From there bare analyte ions enter the mass spectrometer. This method has the advantage of relatively fast sample preparation and stable ionization. More stable ionization produces higher-quality data. Paper-spray ionization mass spectrometry operates by applying sample to a paper triangle. The paper triangle is then electrified in a metal clamp to a few kV before spray solvent is applied. The spray solvent transports analyte in the sample to the tip, where it is ionized and enters the mass spectrometer. One advantage of this method is reduced sample preparation - an analyst can even swipe a surface and cut a triangle directly from the swipe. The data analysis serves to rapidly process tens of samples all at once. The mass spectrometer outputs a file containing a few hundred spectra for each sample. The pipeline processes each one to identify peaks of interest. A full palette of data analysis metrics are generated, including plots of the raw data and plots of calculated values such as isotopic ratios. The pipeline filters the raw data to remove noise and background peaks, as well as peaks representing detector saturation. A heat map is generated to show the overall spectrum in mass-time- intensity space. Post-processing, we obtained the desired calibration curves, demonstrating that both ESI-MS and PSI-MS are viable methods for quantifying trace amounts of inorganics while retaining their chemical speciation information. ESI-MS demonstrated a linear response region of 100 ppb to 20 ppm, with a limit-of-detection of around 100 ppb. At top left is an example spectrum with the {sup 88}SrNO{sub 3} peak identified to show the retention of chemical speciation. PSI-MS showed a linear response region of around 1 ppb to 1 ppm, with a limit-of-detection of near 1 ppb. PSI-MS produced more erratic results than ESI-MS, likely due to the variability in ionization resulting from manual positioning of the paper triangle near the MS inlet. Future efforts will focus on improving the repeatability of PSI-MS as well as analyzing other species of interest such as cerium and uranium. Improvements will also be made to create more reliable data extraction and intelligent data filtering.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Separation of protactinium from uranium-niobium alloys for 231 Pa– 235 U radiochronometry in nuclear forensic investigations

The isolation and purification of protactinium from uranium materials is essential for 231 Pa– 235 U radiochronometry, but separating Pa from uranium-niobium alloys, a common material in the nuclear fuel cycle, is challenging due to the chemical similarity of Pa and Nb. Here, in this work, we present three resin chromatography separation techniques for isolating Pa from U and Nb which were independently developed by three different laboratories through ad hoc adaptations of standard operating procedures. Our results underscore the need for and value of purification methods suitable for a diversity of uranium-based materials to ensure the operational readiness of nuclear forensics laboratories.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The influence of iron incorporation on the microstructure and crystal chemistry of UO 2 fuel

The incorporation of dopants into UO 2 is of interest for both doped advanced fuel and nuclear forensics research. Suitable forensics dopants, or taggants, for nuclear fuels are ones that do not adversely affect the performance of the parent material while still being traceable during key stages of the fuel’s life cycle. In this paper, we present our efforts to understand the effects of doping UO 2 with Fe 2 O 3 under multiple parameters, such as Fe concentration (0–3000 wppm), sintering temperature (1673 K, 1773 K, and 1973 K), sintering time (2–12 h), and atmosphere (reducing and inert). Here, we investigated densification behavior, microstructure evolution, and lattice defects based on the geometric densities, scanning electron microscopy (SEM), X-ray diffractograms, and Raman spectra. The effect of Fe on the microstructure and crystal chemistry of UO 2 is very complex, especially at the intermediate temperature (1773 K), where we found that densification kinetics are enhanced and that lattice contraction occurs for doping concentrations greater than 1000 wppm Fe.

Crystallography↗

Chemical speciation correlated with microstructural heterogeneity of interdicted uranium materials

Two uranium powders seized by law enforcement in Victoria, Australia, have been characterized by established nuclear forensic methods in a previously published study. Here, in this work, the results of further characterization by a scanning transmission x-ray microscope (STXM) operating in the soft x-ray regime are reported. STXM images are used to estimate the elemental distribution in micrometer-scale particles of each powder, and oxygen K-edge absorption spectra are used to determine the chemical state of uranium. The results of the current study are consistent with the previous analysis; the first powder is found to be a potassium-uranium hydrate, while the second powder is determined to be a mixture of uranium oxides primarily consisting of UO 3 .

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Nuclear Forensics

Explore the source record for details and available documents.

Nuclear science and engineering - Nuclear fuel cyc↗

Raman spectroscopy coupled with ambient ionization mass spectrometry: A forensic laboratory investigation into rapid and simple dual instrumental analysis techniques

We present a laboratory experiment, developed around a pair of instrumental analysis techniques, Raman spectroscopy and ambient ionization mass spectrometry (MS), conducted by senior chemistry undergraduate students for bulk analysis of over-the-counter drugs using benchtop versions of the two instruments, as well as trace analysis of illicit drugs utilizing the corresponding portable instruments. The identification and confirmation of seized drugs is a routine operation in forensic laboratories that can be simplified using these two instrumental techniques in tandem. Bulk samples are readily analyzed using conventional Raman spectroscopy followed by paper cone spray ionization (PCSI) MS, while trace analysis is allowed by a simple single-substrate dual-analyzer method using surface enhanced Raman spectroscopy (SERS) from paper followed by paper spray ionization (PSI) MS. The introduction of these novel strategies to the students exposed them to potential career paths in forensic science by means of a hands-on experience that provided fundamental knowledge about this set of analytical methods, including intercomparisons of their performance, as well as practical issues like costs, regulations and databases. The use of portable instrumentation represents an additional learning experience for the students, considering that it is cutting-edge technology that is just now being transferred from academic to industrial labs and that it allows a valuable discussion of the advantages and disadvantages of bringing the laboratory to the field.

47 OTHER INSTRUMENTATION↗

Characterization of ambient polychlorinated biphenyl background conditions in surface waters of the Pajarito Plateau, New Mexico

Abstract This study presents the development of polychlorinated biphenyl (PCB) background threshold values (BTVs) that statistically characterize ambient background conditions for surface waters in undeveloped and developed landscapes of the Pajarito Plateau in the Rio Grande Basin of New Mexico. Between 2009 and 2018, surface water data were collected at 45 locations under a variety of flow conditions and regimes. A total of 163 samples were collected, with roughly 1/3 of samples and locations being in undeveloped areas (n = 53 from 17 locations), and the remainder being in developed areas (n = 110 from 28 locations). While there are areas on the Pajarito Plateau where PCB point sources are known or likely to have contributed to PCBs in soils, PCB BTVs calculated for undeveloped portions of watersheds (upstream of areas where PCB point sources are known or likely to have contributed to PCBs in soils, and therefore not affected by PCB sources within the watershed) are well above New Mexico's human health organism-only (HH-OO) water quality criterion (0.64 ng/L). Background threshold values are even higher in developed areas upstream of managed soil sites, suggesting that in developed areas, both diffuse ambient PCB sources (e.g., atmospheric deposition) and localized urban sources (e.g., building materials, paints, and electrical equipment) contribute to PCBs in those watersheds. These findings indicate that New Mexico's current HH-OO water quality criterion for PCBs cannot practicably be met due to ambient conditions. It is also impracticable to meet the US Environmental Protection Agency (EPA) criterion continuous concentration (CCC) of 14 ng/L in developed background areas, where the BTV is approximately 1.5 times the CCC. Integr Environ Assess Manag 2023;19:1307–1319. © 2022 SETAC

54 ENVIRONMENTAL SCIENCES↗