Search NASASearch

SEARCH · Search NASA

Results for “freestanding spinel membranes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

76 records · Page 4

Exploration Extravehicular Mobility Unit (xEMU) 11 Foot Vacuum Chamber Upgrades Test Results

The Exploration Extravehicular Mobility Unit (xEMU) uncrewed 11 foot vacuum chamber testing evaluated the capabilities of the 11 foot vacuum chamber facility to support advanced spacesuit testing. The government reference design xEMU spacesuit provided a high-fidelity test article to demonstrate 11 foot vacuum chamber capabilities which included: gas loading of the chamber at varying simulated metabolic rates and open loop suit abort operations, Intravehicular Activity (IVA) vacuum access, consumables recharge, IVA vehicle-provided thermal loop cooling, and IVA vehicle-provided power. To demonstrate the xEMU airlock operations transitioning from IVA to EVA conditions without a test subject in the suit, test support equipment was developed to remotely actuate both the Exploration, Servicing, and Cooling Umbilical (ESCU) and the vacuum access umbilical. This test also evaluated the performance of the Exploration Portable Life Support System (xPLSS) at vacuum conditions. Data was collected and analyzed for carbon dioxide (CO2) scrubbing performance of the Rapid Cycle Amine (RCA) swingbed, for thermal regulation performance of the Suit Water Membrane Evaporator (SWME), and for sensor performance across the xPLSS. This paper will detail the findings of the testing performed with these upgrades which discussed previously laid out in ICES-2025-342.

Robert F Marsch

Three-chamber electrochemical reactor for selective lithium extraction from brine

Efficient lithium recovery from geothermal brines is crucial for the battery industry. Current electrochemical separation methods struggle with the simultaneous presence of Na + , K + , Mg 2+ , and Ca 2+ because these cations are similar to Li + , making it challenging to separate effectively. We address these challenges with a three-chamber reactor featuring a polymer porous solid electrolyte in the middle layer. This design improves the transference number of Li + (t Li+ ) by 2.1 times compared to the two-chamber reactor and also reduces the chlorine evolution reaction, a common side reaction in electrochemical lithium extraction, to only 6.4% in Faradaic Efficiency. Employing a lithium-ion conductive glass ceramic (LICGC) membrane, the reactor achieved high t Li+ of 97.5% in LiOH production from simulated brine, while the concentrations of Na + K + , Mg 2+ , and Ca 2+ are below the detection limit. Electrochemical experiments and surface analysis elucidated the cation transport mechanism, highlighting the impact of Na + on Li + migration at the LICGC interface.

Science & Technology - Other Topics

Analytical Model for Atomic Relaxation in Twisted Moiré Materials

By virtue of being atomically thin, the electronic properties of heterostructures built from two-dimensional materials are strongly influenced by atomic relaxation. The atomic layers behave as flexible membranes rather than rigid crystals. Here we develop an analytical theory of lattice relaxation in twisted moiré materials. We obtain analytical results for the lattice displacements and corresponding pseudo gauge fields, as a function of twist angle. We benchmark our results for twisted bilayer graphene and twisted WSe 2 bilayers using large-scale molecular dynamics simulations. Our single-parameter theory is valid in graphene bilayers for twist angles 𝜃 ≳ 0.7°, and in twisted WSe 2 for 𝜃 ≳ 1.6°. Furthermore, we also investigate how relaxation alters the electronic structure in twisted bilayer graphene, providing a simple extension to the continuum model to account for lattice relaxation.

36 MATERIALS SCIENCE

Overcoming the Entropy Penalty of Direct Air Capture for Efficient Gigatonne Removal of Carbon Dioxide

Atmospheric carbon poses an existential threat to civilization via global climate change. Hundreds of gigatonnes of carbon dioxide must be removed from earth’s atmosphere in the next three decades, necessitating a low-cost, energy-efficient process to extract low concentrations of carbon dioxide for conversion to a stable material permanently stored for thousands of years. In this work, the challenge of removing gigatonnes of CO 2 is described via the scale of effort and the thermodynamics of collecting and reducing this diffuse chemical, the accumulation of which imparts a substantial entropy penalty on any atmospheric carbon capture process. The methods of CO 2 reduction combined with upstream direct air capture (DAC) including absorption, membrane separation, and adsorption are compared with biomass torrefaction and permanent burial (BTB). A Monte Carlo model assesses the mass, energy, and economics of the full process of biomass torrefaction from biomass collection and transport to stable carbon burial to determine that 95% of scenarios could remove carbon for less than $200 per CO 2 -tonne-equivalent. Torrefied carbon is further discussed for its long-term stability and availability at the scale required to substantially mitigate the threat of climate change.

biomass

Cation-Diffusive Carbon Interlayers Stabilize Na Metal and Double the Current in Na-S Redox-Flow Batteries for Grid-Scale Energy Storage

The sodium-sulfur nonaqueous redox-flow batteries (Na-S NARFBs) using earth-abundant elements are highly attractive due to the low material cost and improved energy density for grid-scale energy storage. However, the low current performance, poor Na0/Na+ redox kinetics, and Na dendrite growth pose severe challenges. We introduce cation-diffusive layers (CDLs): thin and Na+ affinitive interlayers at the Na anode that direct Na+ transport and stabilize Na deposition. Benchmarking three archetypal materials—carbon paper (CP), glass microfiber paper (GF), and foam—across Na-Na and Na-Cu, and Na-S cells identifies CP as the optimum. CP reduces symmetric cell overpotential by more than 70%, achieves 98% Na plating-stripping efficiency, and doubles the Na-S cell current density from 0.5 to 1.0 mA cm−2 without sacrificing capacity or efficiency. Ex situ electrochemical and SEM/XPS analysis, combined with molecular dynamics (MD) studies, reveal that electron-rich carbon fibers disperse supporting salt aggregates, enrich near-surface Na+ density, and create ion transport pathways for fast Na0/Na+ exchange while mitigating membrane degradation. Because of the ion-centric mechanism, CDLs can be generalized to other metal-anode designs. Further, this work establishes CDL design rules—cationic affinity and appropriate micro/nanostructure—as a simple, scalable route to high-current, durable metal-anode flow batteries.

Wu, Wenda [ORNL] (ORCID:000900033307687X)

Peptoid-Based Nanosheets Exhibiting Broad Antiviral Activity Against Enveloped RNA Viruses

Enveloped RNA viruses, such as Influenza A (H1N1) and Sindbis virus, pose persistent global health threats due to their high mutation rates, efficient transmission, and frequent drug resistance. By mimicking host cell membrane receptors, multivalent virus inhibitors can block viral attachment, making them promising broad-spectrum antiviral agents. However, most of existing antivirals are often limited by strain specificity, short-lived efficacy, and toxicity. Here, we introduce a broad-spectrum antiviral platform based on highly tunable and biocompatible two-dimensional nanomembranes (2DNMs) self-assembled from amphiphilic peptoids, operating via a non-genomic, mutation-insensitive mechanism. By varying peptoid sequence, we design and synthesize over twenty different 2DNMs with various surface charge and high density of viral-attachment ligands (VALs). The self-assembled architecture of these stable 2DNMs provides cooperative noncovalent multivalent binding to virus particles that result in effective inhibition of viral infection. Screening of variants identified three leads that potently suppressed Influenza A (H1N1) and Sindbis virus infection across median tissue culture infectious dose (TCID50), plaque, RT–qPCR, and immunofluorescence assays, while maintaining >90% cell viability. These nanosheets significantly reduced infectious titers, viral RNA replication, and intracellular viral protein expression, indicating inhibition at early stages of viral entry and propagation. The sequence programmability, chemical robustness, and mutation-insensitive antiviral activity distinguish 2DNMs from traditional antivirals and positions them as a versatile materials platform for antiviral coatings, protective barriers, and prophylactic biomedical applications.

Influenza A virus

Activation dynamics of a water-soluble human mu-opioid receptor

The mu-opioid receptor (MOR), a class A G protein-coupled receptor mediates opioid analgesia and remains a central target for pain therapeutics. While crystal structures of MOR exist, they provide limited insight into the receptor’s dynamic conformational landscape underlying function. Here, we engineered a thermostable water-soluble MOR variant (wsMOR) that retains native-like ligand-binding and activation dynamics. This variant enables high-yield production and detailed solution-phase structural studies that are challenging with membrane-embedded MOR, providing a valuable tool for studying receptor activation and aqueous-phase drug screening. Using a combined computational and experimental approach, we performed long-timescale all-atom molecular dynamics simulations together with neutron scattering and single-molecule FRET, revealing a structurally stable receptor with a diverse ensemble of conformations at different temporal resolutions. In the ligand-free state, wsMOR displayed high conformational flexibility, which decreased upon agonist binding, particularly in transmembrane helix 6, a hallmark of G protein-coupled receptor activation. Positive allosteric modulation and G protein binding further stabilized active-like states. These findings highlight wsMOR’s conformational plasticity across picosecond to millisecond timescales and provide a foundation for structure-guided development of next-generation opioid ligands with improved efficacy and safety.

E, Agyemang [University of Tennessee Knoxville]

Designing a Propylene-Glycol Coolant Servicer System for Gateway’s Internal Active Thermal Control System

A human spacecraft ATCS—especially one using single-phase coolant loops exposed to cabin atmospheric conditions—requires periodic degassing and refilling to support long-duration missions of 15 to 30 years. During initial fill operations, system maintenance, gas permeation, and quick-disconnect mating or de-mating, small amounts of gas can gradually enter the coolant system over time. This can lead to degraded heat transfer performance, pump cavitation, and potentially pump vapor lock if a significant gas volume accumulates over time. Additionally, system leaks and routine fluid sampling can gradually reduce accumulator volumes to unacceptable levels, requiring periodic refills. In more severe cases, catastrophic changes in fluid composition may necessitate emergency draining, refilling, and degassing to ensure continued system functionality. These risks were identified and mitigated on the ISS ITCS through the development of a dual-membrane degasser ORU and a Fluid Servicer System ORU for coolant refilling. These systems were developed for the fully water-based ISS ITCS Coolant[1]. The Gateway space station, the first permanent human habitat in lunar orbit, uses a propylene-glycol/water coolant mixture, which has significantly different fluid properties compared to pure water. Because microgravity degassing technologies are sensitive to fluid surface tension and viscosity, existing ISS hardware is not suitable for servicing a propylene-glycol-based TCS. Unlike the ISS, the Gateway will operate in a higher-radiation environment and must meet stricter mass constraints due to its location outside of low earth orbit. This Government Furnished Equipment (GFE) flight hardware project aims to develop a lightweight, radiation-resistant Coolant Servicer System (CSS) capable of degassing and refilling Gateway’s propylene-glycol water-based IATCS.

Propylene Glycol Water

Designing a Propylene-Glycol Coolant Servicer System for Gateway’s Internal Active Thermal Control System

A human spacecraft ATCS—especially one using single-phase coolant loops exposed to cabin atmospheric conditions—requires periodic degassing and refilling to support long-duration missions of 15 to 30 years. During initial fill operations, system maintenance, gas permeation, and quick-disconnect mating or de-mating, small amounts of gas can gradually enter the coolant system over time. This can lead to degraded heat transfer performance, pump cavitation, and potentially pump vapor lock if a significant gas volume accumulates over time. Additionally, system leaks and routine fluid sampling can gradually reduce accumulator volumes to unacceptable levels, requiring periodic refills. In more severe cases, catastrophic changes in fluid composition may necessitate emergency draining, refilling, and degassing to ensure continued system functionality. These risks were identified and mitigated on the ISS ITCS through the development of a dual-membrane degasser ORU and a Fluid Servicer System ORU for coolant refilling. These systems were developed for the fully water-based ISS ITCS Coolant[1]. The Gateway space station, the first permanent human habitat in lunar orbit, uses a propylene-glycol/water coolant mixture, which has significantly different fluid properties compared to pure water. Because microgravity degassing technologies are sensitive to fluid surface tension and viscosity, existing ISS hardware is not suitable for servicing a propylene-glycol-based TCS. Unlike the ISS, the Gateway will operate in a higher-radiation environment and must meet stricter mass constraints due to its location outside of low earth orbit. This Government Furnished Equipment (GFE) flight hardware project aims to develop a lightweight, radiation-resistant Coolant Servicer System (CSS) capable of degassing and refilling Gateway’s propylene-glycol water-based IATCS.

Propylene Glycol Water

SERFE Ground Unit EVA Series After Three Year Spacesuit Stowage Period

NASA’s spacesuit government reference design for returning to the Moon is called the Exploration Extravehicular Mobility Unit (xEMU). The xEMU subassembly that provides life support, such as oxygen and thermal control, is the Portable Life Support System (PLSS). Inside the PLSS is a new technology that NASA wanted to test to provide cooling to the crew during EVAs (ExtraVehicular Activity). This technology is called the Spacesuit Water Membrane Evaporator (SWME). In order to test SWME in an improved thermal control loop (TCL) both on Earth and in Space, the Spacesuit Evaporation Rejection Flight Experiment (SERFE) was created. The Ground unit, or testbed at Johnson Space Center (JSC), tested the cooling technology in Earth’s gravity, while the Flight unit, or payload on the International Space Station (ISS), tested the cooling technology in micro-gravity. Since fluids flow differently in micro-gravity, testing in both environments would provide important data for improving cooling performance during EVAs. Both units completed 25 simulated EVAs with the same settings so SWME performance on the ground could be compared to the ISS. The Flight unit was completed first and performed EVAs on the ISS between 2020 and 2022. The Ground unit performed EVAs between 2021 and 2022. When the Flight unit came back from the ISS, it was taken apart for analysis. This analysis looked at how well SWME was able to maintain its heat rejection capability after various dwell times, such as a 90 day Airlock Coolant Loop Recovery (ALCLR) cycle, when the Extravehicular Mobility Unit (EMU) currently on the ISS would normally need maintenance. After a three year simulated spacesuit dwell, the Ground unit performed another EVA series in 2025 to test SWME’s shelf life. The results from this test series will inform mission planning as NASA plans to go back to the Moon and beyond.

Michael Lewandowski

SERFE Ground Unit EVA Series After Three Year Spacesuit Stowage Period

NASA’s spacesuit government reference design for returning to the Moon is called the Exploration Extravehicular Mobility Unit (xEMU). The xEMU subassembly that provides life support, such as oxygen and thermal control, is the Portable Life Support System (PLSS). Inside the PLSS is a new technology that NASA wanted to test to provide cooling to the crew during EVAs (ExtraVehicular Activity). This technology is called the Spacesuit Water Membrane Evaporator (SWME). In order to test SWME in an improved thermal control loop (TCL) both on Earth and in Space, the Spacesuit Evaporation Rejection Flight Experiment (SERFE) was created. The Ground unit, or testbed at Johnson Space Center (JSC), tested the cooling technology in Earth’s gravity, while the Flight unit, or payload on the International Space Station (ISS), tested the cooling technology in micro-gravity. Since fluids flow differently in micro-gravity, testing in both environments would provide important data for improving cooling performance during EVAs. Both units completed 25 simulated EVAs with the same settings so SWME performance on the ground could be compared to the ISS. The Flight unit was completed first and performed EVAs on the ISS between 2020 and 2022. The Ground unit performed EVAs between 2021 and 2022. When the Flight unit came back from the ISS, it was taken apart for analysis. This analysis looked at how well SWME was able to maintain its heat rejection capability after various dwell times, such as a 90 day Airlock Coolant Loop Recovery (ALCLR) cycle, when the Extravehicular Mobility Unit (EMU) currently on the ISS would normally need maintenance. After a three year simulated spacesuit dwell, the Ground unit performed another EVA series in 2025 to test SWME’s shelf life. The results from this test series will inform mission planning as NASA plans to go back to the Moon and beyond.

SWME

Efficient electrocatalytic valorization of chlorinated organic water pollutant to ethylene

Electrochemistry can provide an efficient and sustainable way to treat environmental waters polluted by chlorinated organic compounds. However, the electrochemical valorization of 1,2-dichloroethane (DCA) is currently challenged by the lack of a catalyst that can selectively convert DCA in aqueous solutions into ethylene. Here, in this work, we report a catalyst comprising cobalt phthalocyanine molecules assembled on multiwalled carbon nanotubes that can electrochemically decompose aqueous DCA with high current and energy efficiencies. Ethylene is produced at high rates with unprecedented ~100% Faradaic efficiency across wide electrode potential and reactant concentration ranges. Kinetic studies and density functional theory calculations reveal that the rate-determining step is the first C–Cl bond breaking, which does not involve protons—a key mechanistic feature that enables cobalt phthalocyanine/carbon nanotube to efficiently catalyse DCA dechlorination and suppress the hydrogen evolution reaction. The nanotubular structure of the catalyst enables us to shape it into a flow-through electrified membrane, which we have used to demonstrate >95% DCA removal from simulated water samples with environmentally relevant DCA and electrolyte concentrations.

Choi, Chungseok [Yale Univ., New Haven, CT (United

Highly Porous Polyimide Gel for Use as Battery Separator with Room Temperature Ionic Liquid Electrolytes

Advanced aerospace vehicular concepts require advances in many existing technologies, including space power and energy storage systems. Batteries represent one of the major areas in need of improvement, both in terms of energy density and safety, with growing concerns over the fire safety of commercial lithium-ion batteries. This has prompted efforts to develop nonflammable battery components, namely the electrolyte and separator. Existing commercial lithium-ion batteries utilize polyolefin microporous membranes as separators with an electrolyte consisting of a lithium salt dissolved in a mixture of cyclic carbonate solvents. This separator/electrolyte combination has ionic conductivities in the range of 10 −2 to 10 −3 S/cm. However, the cyclic carbonate solvents are inherently flammable. Room-temperature ionic liquids (RTILs) appear to be a safer alternative. They offer good ionic conductivities and are inherently nonvolatile and nonflammable, giving them a safety advantage. However, many promising RTILs for battery electrolytes are not compatible with commercial polyolefin separator materials. Alternative separator materials, such as polyimides, are non-flammable and are capable of accepting RTILs into their structure. Polyimide gels, with a composition of 4,4′-oxydianiline, 3,3′,4,4′-tetracarboxylic dianhydride and cross-linked with Desmodur N3300A, possess an open-porous, fibrillar network architecture which offers a high degree of porosity (typically greater than 85% porosity) for lithium-ion transport and conduction, as well as good mechanical properties. Furthermore, these polyimide gels are compatible with selected imidazolium-based RTILs. Nonflammable separator/electrolyte systems with room-temperature conductivities in the range of 10 −3 S/cm have been evaluated. It has been demonstrated that 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide was the most promising among six RTILs screened, in terms of both ionic conductivity and constant current cycling.

Polyimide

Numerical Investigation of Heat Transfer and Fluid Flow within Electrochemical Hydrogen Peroxide Generation Unit

Long-term manned space missions require the onboard production of disinfectants essential for maintaining crew health and supporting life systems. Currently, disinfection aboard the International Space Station (ISS) relies on disposable wetted wipes, which are regularly resupplied from Earth. This approach imposes a significant burden on resupply logistics, storage, and waste management. To address these challenges and support future missions, efforts are underway to develop an in-situ solution that electrochemically generates hydrogen peroxide disinfectant using onboard resources. In collaboration with NASA, Faraday Technology, Inc. has advanced this concept through a series of Small Business Innovation Research (SBIR) projects, resulting in the development of a Peroxide Generation Unit (PGU). The PGU can produce up to 3 wt.% hydrogen peroxide on-demand at a rate of 1 liter per day, providing a sustainable alternative to Earth-dependent supplies. The resulting aqueous hydrogen peroxide (H₂O₂) is an effective disinfectant, safe for crew use, compatible with spacecraft systems, and free from volatiles, off-gassing, or residues. This innovation offers a reliable, efficient solution for onboard disinfection, reducing dependence on Earth-based resupply while ensuring the health and safety of space crews. Generating hydrogen peroxide at the required rate needs high voltages and currents, exceeding 20V and 2A respectively, which leads to significant heat generation from Joule heating. This temperature rise poses a risk to sensitive system components, especially critical and expensive membranes that can degrade under thermal stress. To mitigate this risk, the thermal, fluid, and electrical flows within the system are modeled computationally using the commercial software COMSOL. The numerical simulations are validated against experimental data from both sub-scale and alpha-scale systems. Once verified, the model is employed to identify thermal hotspots, investigate their underlying causes, and explore solutions to prevent them.

Life Support Systems (LSS)

Henry’s Solubility and Diffusion Coefficients for 29 Volatile Organic Compounds in Polydimethylsiloxane Sylgard 184 at 293 K

Two-dimensional (2D) inverse gas chromatography (IGC) enables simultaneous determination of Henry’s solubility and Fickian diffusion coefficients for volatile organic compounds (VOCs) in polymer films. This technique offers a significant advantage over traditional cylindrical column IGC by providing precise control and measurement of the film thickness (here, 0.064 ± 0.002 mm), which is the critical length scale for accurate diffusivity determination. We apply this methodology to characterize VOC transport in Sylgard 184, a widely used polydimethylsiloxane (PDMS)-based polymer containing substantial silica filler content. At room temperature (20 °C), we measured solubility and diffusion coefficients for 29 common VOCs spanning diverse chemical functionalities, including alkanes, aromatics, chlorinated solvents, ketones, esters, and alcohols. Comparison with literature data for pure PDMS reveals that VOC solubility in Sylgard 184 is generally higher; for most non-hydrogen-bonding compounds it remains within a factor of 2 of pure PDMS, whereas alcohols are enhanced by roughly 1.8 to 3.7 times, which we attribute to favorable interactions with residual silanol groups on the silanized silica filler. Diffusion coefficients range from 1.0 × 10 –6 cm 2 /s (n-undecane) to 8.9 × 10–5 cm 2 /s (acetonitrile) and align well with extrapolated literature values for PDMS. This study provides essential thermodynamic and transport data for predicting VOC permeation in Sylgard 184 while demonstrating the utility of 2D IGC as a robust technique for characterizing rubbery polymer membranes across diverse industrial applications.

organic

Hybrid biophysical systems for atmospheric CO 2 capture

Negative emissions technologies will be essential for limiting anthropogenic global temperature increases to 2 °C in the later years of the 21st century. Carbonic anhydrase (CA) metalloenzymes catalyze the otherwise slow conversion of CO 2 into carbonic acid (H 2 CO 3 ), suggesting their utility in the rapid hydration and downstream capture of dissolved CO 2 in aqueous media for a variety of CO 2 capture methods, such as thermal and pH swings and mineralization. The possibility of driving the rapid capture of CO 2 by catalyzing the CO 2 hydration bottleneck carries real potential for realizing efficient direct air capture (DAC) and direct ocean capture (DOC) systems. However, scaled application of CAs will be dependent on some way of economically sourcing the enzymes at volumes relevant to scaled DAC/DOC operations. In this perspective, we consider the prospect of catalyzing CO 2 hydration using a CA that is bound to the outer membrane of a cyanobacterial host, engineered constructs we call CyCAMs. Coupling extracellular CA expression to a marine, photosynthetic cyanobacterial host results in a CO 2 hydration catalyst that is continuously refreshed during the bacterial growth cycle, without the need for enzyme purification or harvesting steps. In the case of marine cyanobacteria, sunlight and the solutes native to seawater provide the respective energy, nutrients and sources of inorganic carbon essential to maintaining the bacterial population. We consider the potential impact of CA-mediated CO 2 hydration on a variety of DAC processes, with CO 2 mineralization explored as a primary use case.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Performance of a Regenerative Fuel Cell System for the Lunar Surface

Regenerative fuel cells (RFCs) are an attractive energy storage solution for lunar missions as a technology capable of providing a higher specific energy (i.e., W∙h/kg) than state-of-the-art packaged Li-ion battery systems. An RFC consists of the (1 & 2) electrochemical stacks (chemical to electrical energy conversion to supply electricity to an external load, i.e. the fuel cell reaction, and electrical to chemical energy conversion of supplied electrical power to dissociate water into hydrogen and oxygen gases, i.e. water electrolysis), (3) fluidic conditioning, (4) reactant storage, (5) avionics, (6) power management and distribution (PMAD), and (7) thermal management. NASA’s Glenn Research Center has designed, assembled, and tested a breadboard RFC sys-tem capable of operating autonomously for multiple simulated lunar day/night cycles in a laboratory environment. The system is comprised of a non-flow through proton exchange membrane (PEM) fuel cell stack and a liquid-anode feed PEM electrolyzer (EZ) stack designed to electrochemically compress the reactants at balanced pressures up to 12.4 MPa (1800 psia). The fluidic conditioning, avionics, PMAD, and thermal management sub-systems are largely comprised of commercial-off-the-shelf components for this system-level development effort. The hardware is controlled by a CubeSat space processor running an operational program based on core flight architecture that can control the RFC hardware autonomously through a state machine with fault monitoring. The testing results highlighted here were completed with the system in an open-loop configuration such that reactants generated through water electrolysis were vented while gas cylinders supplied fuel cell operation. The breadboard operated autonomously, but there were five unplanned transitions to a safe state that required a manual restart after reviewing the data, determining a root cause, and implementing a solution. Four of the transitions were caused by the thermal management subsystem and the fifth was caused by a water management control issue in the EZ sub-system. The RFC system operated for over 550 hours with the final cycle being slightly abbreviated due to reasons unrelated to system performance.

Kerrigan Cain

Performance of a Regenerative Fuel Cell System for the Lunar Surface

Regenerative fuel cells (RFCs) are an attractive energy storage solution for lunar missions as a technology capable of providing a higher specific energy (i.e., W∙h/kg) than state-of-the-art packaged Li-ion battery systems. An RFC consists of the (1 & 2) electrochemical stacks (chemical to electrical energy conversion to supply electricity to an external load, i.e. the fuel cell reaction, and electrical to chemical energy conversion of supplied electrical power to dissociate water into hydrogen and oxygen gases, i.e. water electrolysis), (3) fluidic conditioning, (4) reactant storage, (5) avionics, (6) power management and distribution (PMAD), and (7) thermal management. NASA’s Glenn Research Center has designed, assembled, and tested a breadboard RFC sys-tem capable of operating autonomously for multiple simulated lunar day/night cycles in a laboratory environment. The system is comprised of a non-flow through proton exchange membrane (PEM) fuel cell stack and a liquid-anode feed PEM electrolyzer (EZ) stack designed to electrochemically compress the reactants at balanced pressures up to 12.4 MPa (1800 psia). The fluidic conditioning, avionics, PMAD, and thermal management sub-systems are largely comprised of commercial-off-the-shelf components for this system-level development effort. The hardware is controlled by a CubeSat space processor running an operational program based on core flight architecture that can control the RFC hardware autonomously through a state machine with fault monitoring. The testing results highlighted here were completed with the system in an open-loop configuration such that reactants generated through water electrolysis were vented while gas cylinders supplied fuel cell operation. The breadboard operated autonomously, but there were five unplanned transitions to a safe state that required a manual restart after reviewing the data, determining a root cause, and implementing a solution. Four of the transitions were caused by the thermal management subsystem and the fifth was caused by a water management control issue in the EZ sub-system. The RFC system operated for over 550 hours with the final cycle being slightly abbreviated due to reasons unrelated to system performance.

Kerrigan Cain