Search NASA⌕ Search

SEARCH · Search NASA

Results for “full width at half maximum”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Regular radiation field pulses produced by intracloud lightning discharges

Sequences or bursts of uniform pulses have been recorded during a large fraction of intracloud lightning discharges in Florida and Arizona. The wave form of a typical pulse begins with a fast large-amplitude portion followed by a small and slowly varying overshoot. The full width and half maximum of the large amplitude peak is typically 0.75 microsec, and the time intervals between pulses are typically 5 microsec in both maritime and continental storms. The pulse shapes and interval times suggest that the source of these pulses in an intracloud dart-stepped leader process similar to that which has been photographed in discharges to ground.

Krider, E. P.↗

The Lockheed alternate partial polarizer universal filter

A tunable birefringent filter using an alternate partial polarizer design has been built. The filter has a transmission of 38% in polarized light. Its full width at half maximum is .09A at 5500A. It is tunable from 4500 to 8500A by means of stepping motor actuated rotating half wave plates and polarizers. Wave length commands and thermal compensation commands are generated by a PPD 11/10 minicomputer. The alternate partial polarizer universal filter is compared with the universal birefringent filter and the design techniques, construction methods, and filter performance are discussed in some detail. Based on the experience of this filter some conclusions regarding the future of birefringent filters are elaborated.

Title, A. M.↗

Ultraviolet emission line profiles of flares and active regions

A preliminary description of ultraviolet spectra of active regions and flares, photographed from Skylab by the Naval Research Laboratory's UV spectrograph, is given. The findings can be summarized as follows: (1) Line profiles of medium-ionized lines (transition-zone lines) show the most pronounced broadenings and shifts in flares and flare-like events; (2) typical full widths at half maximum of these lines correspond to Doppler velocities of 70 km/s; (3) shifts of the same magnitude can be observed; (4) intersystem lines are not broadened or shifted; (5) forbidden coronal lines and intersystem lines become enhanced in the flare spectrum at the moment when the turbulence seen in the allowed transitions disappears; and (6) a very broad line at 1354.2 A, which appears only in flare spectra, seems to be the forbidden transition 3P(1)-3P(0) of Fe XXI.

Brueckner, G. E.↗

Electronic transition CN laser

A 20 kW electric-discharge pumped CN laser oscillating on the A(2) Pi-X(2) Sigma molecular system is presented. Excitation is by a simple longitudinal discharge struck through HCN vapor. Twenty kW peak power is generated in a 150 nsec full-width half-maximum pulse. Two lasing bands were observed in the A-X system: the (0,1) and (0,2) bands near 1.42 and 2.0 microns respectively. Both P and Q branches are active in the two bands, with Q bands stronger. Peak laser energy is 3 mJ. Products of UV photolysis of HCN, electron impact excitation of HCN, and other possible excitation mechanisms and laser efficiency are discussed.

Quick, C. R., Jr.↗

The electric fields produced by lightning stepped leaders

The electric fields produced by stepped and dart-stepped leaders which immediately precede return strokes in lightning discharges to the ground have been recorded in Florida and Arizona. The mean interval time between normal steps is about 16 microsec, and the mean interval between dart steps is 6-8 microsec. The amplitudes of leader pulses in Florida increase just prior to the return stroke, the largest usually being about 10% of the return-stroke peak. In Arizona the leader pulse amplitudes are smaller than those in Florida, in relation to the return stroke, and are not as easy to identify. The shapes of the fields produced by normal steps are similar to dart steps, and the dart steps are very similar to regular sequences of pulses produced by many intracloud discharges. The 10-90% rise times of individual step wave forms are often less than 0.3 microsec, and the full width at half maximum of a step pulse is typically 0.4-0.5 microsec under conditions where the propagation distortion is minimal. The amplitudes and the shapes of leader step wave forms suggest that the peak step current is at least 2000-8000 A close to the ground and that the maximum rate of change of step current is 6-24 kA/microsec or larger. A rough estimate of the minimum charge lowered during the formation of a step is 0.001 to 0.004 C.

Krider, E. P.↗

Proposed rocket experiments to measure the profile and intensity of the solar He1584A resonance line

The intensity and profile of the helium resonance line at 584 A from the entire disc of the sun was investigated using a rocket-borne helium-filled spectrometer and a curve of growth technique. The line profile was found to be accurately represented by a Gaussian profile with full width at half maximum of 122 plus or minus 10m A while the integrated intensity was measured to be (2.6 plus or minus 1.3) x 10 to the 9th power/photons sec sq cm at solar levels of F sub 10.7 = 90.8 x 10 to the minus 22th power/sq m H sub z and R sub z = 27. The measured linewidth is in good agreement with previous spectrographic measurement but the integrated intensity is larger than most previous photoelectric measurements. However, the derived line center flux of (2.0 plus or minus 1.0) x 10 to the 10th power/photons sec sq cm A is in good agreement with values inferred from airglow measurements.

Judge, D. L.↗

Extensions of the Wilson-Bappu effect among very luminous stars

It has been stated that the technique used by Wilson and Bappu (1957) in their study of the observational correlation of M sub V and the logarithm of the full width at half maximum of the Ca II K-line central emission for G, K, and M stars has a plus or minus 0.5 mag accuracy. A tabulation by Wilson (1976) suggests, however, that the error may be only plus or minus 0.3 mag. This accuracy makes the approach valuable for late-type supergiants since other methods suffer from comparable errors. A description is in this connection presented of a new class of emission lines in late-type giant and supergiant spectra that exhibit M sub V correlated widths, yet are detectable among the brightest stars.

Stencel, R. E.↗

Measurement of the profile and intensity of the solar He I lambda 584-A resonance line

The intensity and profile of the helium resonance line at 584 A from the entire disk of the sun was investigated by using a rocket-borne helium-filled spectrometer and a curve-of-growth technique. The line profile was found to be accurately represented by a Gaussian profile with full width at half maximum of 122 + or - 10 mA, while the integrated intensity was measured to be 2.6 + or - 1.3 billion photons/s per sq cm at solar activity levels of F(10.7) = 90.8 x 10 to the -22nd per sq m/Hz and Rz = 27. The measured line width is in good agreement with previous spectrographic measurements, but the integrated intensity is larger than most previous photoelectric measurements. However, the derived line center flux of 20 + or - 10 billion photons/s per sq cm/A is in good agreement with values inferred from airglow measurements.

Maloy, J. O.↗

X-ray reflectometer for optical efficiency and scatter measurements

An instrument has been developed to determine the reflection efficiency and scatter characteristics of optical samples at X-ray wavelengths from 1.5 to 113 A. The reflectometer operates in an oil-free vacuum chamber and measures the reflection efficiency and scatter characteristics as a function of the angle of incidence. The reflection efficiency is given for 8.34-A radiation incident on a fused silica sample finished to a flatness of one-tenth of a wavelength. The experimental reflection efficiency is compared with the theoretical data. The scatter curves are given for the direct X-ray beam and for the beam reflected from the fused silica sample at an angle of incidence of 50 arcmin. The full-width-at-half-maximum (FWHM) resolution of the instrument is approximately 13 arcsec, as determined by a least-squares smoothing of the experimental data.

Reynolds, J. M.↗

Evidence for parallel electric field particle acceleration in the dayside auroral oval

Electron and ion energy spectra and electron pitch angle distributions are presented for two sounding rocket flights in the dayside auroral zone. At times, effects of dc electric fields parallel to the magnetic field are evident in that: (1) within precipitation features, protons are decelerated by an amount of energy consistent with that which electrons gain and (2) electrons are sometimes aligned to within 3 deg (full width at half maximum) of the magnetic field. A maximum altitude for the accelerating region of several thousand kilometers is deduced from the narrow width of the pitch angle distribution and also from time-of-flight delays between the observation of accelerated electrons and decelerated protons.

Torbert, R. B.↗

High spectral and spatial resolution observations of the 12.28 micron emission from H2 in the Orion molecular cloud

The pure rotational S(2) line of molecular hydrogen at 12.28 microns was looked for in 44 positions in the Orion moleular cloud with 6 in. beams and 35 km/s spectral resolution; it was detected in 27 positions. Emission was observed over a velocity range of + or - 100 km/s. The lines are approximately symmetric, and have full widths at half maximum ranging from 100 km/s down to the resolution limit. The distribution of intensities and line shapes is largely consistent with that seen in the 2 micron hydrogen transitions. However, unexpectedly complex line profiles and point-to-point variations in linear shapes appear, particularly in the region near IRc9.

Beck, S. C.↗

Measurement of the profile of solar He I resonance lines

The analysis of data obtained by a rocket-borne helium-filled spectrometer employing a curve-of-growth technique in 1977 and 1980 is used in an investigation of the 584-A helium resonance line from the full solar disk. Between 6.5 and 13% of the Gaussian core area was found to be missing through self-reversal. Line widths from 1980 and 1977 were 101 + or - 10 mA and 128 + or - 20 mA full width at half maximum, respectively. No consistent relationship is found between the measured widths and solar activity.

Phillips, E.↗

Quasi-relativistic electron precipitation due to interactions with coherent VLF waves in the magnetosphere

The equations of motion for the cyclotron resonance interaction between coherent whistler mode waves and energetic particles are rederived with the inclusion of relativistic effects. The pitch angle scattering of the near-loss-cone quasi-relativistic electrons trapped in the magnetosphere is studied using a test particle method employing these relativistic equations, and the precipitated energy spectrum due to the wave-induced perturbations of a full distribution of particles is computed. Results show that the full width at half maximum peak width of the rms scattering pattern of the near-loss-cone particles would give an upper bound to the peak width of the associated precipitated energy spectrum under the conditions of moderate wave intensities in the low L shell region. In addition, it is found that the peak widths are within the upper limit values measured by recent satellite experiments. It is concluded that interactions of inner radiation belt particles with monochromatic waves could produce precipitated fluxes with relatively sharp spectral widths, and that therefore the L-dependent narrow peaks observed by low altitude satellite particle detectors could be caused by such interactions.

Chang, H. C.↗

A helium-3 cooled bolometer system for one millimeter continuum observations

A new, 1-mm-continuum, bolometer detector system has been constructed employing internal adsorption pumping of He-3 to reach an operating temperature close to 0.4 K. The system spectral bandwidth is 800 to 1200 microns. Although the system was originally designed to be used on the 5-m Hale telescope, it has also been successfully used on the 4-m Anglo-Australian telescope and on the 10-m dish at Owens Valley, California. At the 5-m Hale telescope, the system has a full width-half maximum (FWHM) beam size of 55 sec and an instantaneous noise-equivalent flux density of 6 Jy/square root of (Hz)/ in good weather.

Roellig, T. P. L.↗

Thermal detectors as X-ray spectrometers

Sensitive thermal detectors should be useful for measuring very small energy pulses, such as those produced by the absorption of X-ray photons. The measurement uncertainty can be very small, making the technique promising for high resolution nondispersive X-ray spectroscopy. The limits to the energy resolution of such thermal detectors are derived and used to find the resolution to be expected for a detector suitable for X-ray spectroscopy in the 100 eV to 10,000 eV range. If there is no noise in the thermalization of the X-ray, resolution better than 1 eV full width at half maximum is possible for detectors operating at 0.1 K. Energy loss in the conversion of the photon energy to heat is a potential problem. The loss mechanisms may include emission of photons or electrons, or the trapping of energy in long lived metastable states. Fluctuations in the phonon spectrum could also limit the resolution if phonon relaxation times are very long. Conceptual solutions are given for each of these possible problems.

Moseley, S. H.↗

Thermal detectors as X-ray spectrometers

Sensitive thermal detectors should be useful for measuring very small energy pulses, such as those produced by the absorption of X-ray photons. The measurement uncertainty can be very small, making the technique promising for high resolution nondispersive X-ray spectroscopy. The limits to the energy resolution of such thermal detectors are derived and used to find the resolution to be expected for a detector suitable for X-ray spectroscopy in the 100 eV to 10,000 eV range. If there is no noise in the thermalization of the X-ray, resolution better than 1 eV full width at half maximum is possible for detectors operating at 0.1 K. Energy loss in the conversion of the photon energy to heat is a potential problem. The loss mechanisms may include emission of photons or electrons, or the trapping of energy in long lived metastable states. Fluctuations in the phonon spectrum could also limit the resolution if phonon relaxation times are very long. Conceptual solutions are given for each of these possible problems.

Moseley, S. H.↗

Experimental tests of a single-photon calorimeter for X-ray spectroscopy

Tests have been made of a nondispersive spectroscopic X-ray detector which operates by measuring the temperature rise following absorption of a single photon. Thermal pulses from 6-keV X-rays have been observed, and the different amplitudes resulting from Mn K-alpha and K-beta events have been resolved. This device was assembled to make quantitative tests of theoretical calculations of the properties of such detectors, and its high heat capacity does not allow it to attain the very high resolution predicted for detectors made by more sophisticated, but still straightforward, techniques. Both the measured resolution of 270-eV full width at half maximum and the absolute amplitude of the response are consistent with predictions. Nonthermal effects in the thermistor limit the precision of this comparison to about 30 percent.

Mccammon, D.↗

A transient digitiser for fast air shower events

Air shower structure are often measured on time scales of a few nanoseconds. Longitudinal disk structure near the core is of the order of meters in dimension, air Cerenkov pulses have full widths at half maximum of the order of tens of nanoseconds, and fast timing over typical arrays is usually measured to nanosecond accuracy. oscilloscopes can be used but have very limited dynamic range and are expensive if measurements down to a few nanoseconds are to be made. For the fast Cerenkov work, an instrument with better dynamic range than an oscilloscope and with a time resolution sufficient to allow measurements limited only by system risetime of a few nanoseconds is needed. A 16/32 channel, 8 bit, fast transient digitizer was designed and built which runs at sample intervals down to approx. 1 nanosecond per channel.

Wild, N. R.↗