Search NASA⌕ Search

SEARCH · Search NASA

Results for “grab sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Emissions of nitrous oxide from biomass burning

A study has been conducted which compared N2O results obtained over large prescribed fires or wildfires, in which 'grab-sampling' with storage had been used with N2O measurements made in near-real time. CO2-normalized emission ratios obtained initially from the laboratory fires are substantially lower than those obtained over large-scale biomass fires. Combustion may not be the only source of N2O in large fire smoke plumes; physical, chemical, and biochemical processes in the soil may be altered by large biomass fires, leading to large N2O releases.

Winstead, Edward L.↗

The gradient of meteorological and chemical variables across the tropopause

The downward transport of air through the tropopause can bring substantial amounts of ozone and reactive nitrogen into the upper troposphere. In this cold region of the atmosphere, O3 is particularly effective as a greenhouse gas. As part of the North Dakota Thunderstorm Project in June 1989, the NCAR Sabreliner made five flights through the tropopause. We measured ozone, nitric oxide (NO), total reactive nitrogen (NO(y)), carbon monoxide (CO), and water vapor (H2)), and took grab samples for hydrocarbon (HC) analysis. Hydrocarbons, CO, and H2O, species with sources primarily at the earth's surface, showed a strong concentration decrease with increasing altitude, while O3 and NO(y), species with a source in the stratosphere, showed a strong concentration increase with increasing altitude. Stratospheric concentrations of NO(x), NO(y), and H2O were all high relative to winter observations made during NASA's AASE. We suggest that midlatitude thunderstorms may inject wet, NO-rich air into the lower stratosphere. Calculation based on measured ratios of NO(x) and NO(y) to O3 yield a total flux of reactive nitrogen from the Northern Hemisphere stratosphere into the troposphere of 1 to 2 Tg(N) yr(exp -1) with about 8 percent in the form of NO(x). This value is higher than reported estimates of total stratospheric nitrogen fixation.

Dickerson, Russell R.↗

Gas Sensor Evaluations in Polymer Combustion Product Atmospheres

Toxic gases produced by the combustion or thermo-oxidative degradation of materials such as wire insulation, foam, plastics, or electronic circuit boards in space shuttle or space station crew cabins may pose a significant hazard to the flight crew. Toxic gas sensors are routinely evaluated in pure gas standard mixtures, but the possible interferences from polymer combustion products are not routinely evaluated. The NASA White Sands Test Facility (WSTF) has developed a test system that provides atmospheres containing predetermined quantities of target gases combined with the coincidental combustion products of common spacecraft materials. The target gases are quantitated in real time by infrared (IR) spectroscopy and verified by grab samples. The sensor responses are recorded in real time and are compared to the IR and validation analyses. Target gases such as carbon monoxide, hydrogen cyanide, hydrogen chloride, and hydrogen fluoride can be generated by the combustion of poly(vinyl chloride), polyimide-fluoropolymer wire insulation, polyurethane foam, or electronic circuit board materials. The kinetics and product identifications for the combustion of the various materials were determined by thermogravimetric-IR spectroscopic studies. These data were then scaled to provide the required levels of target gases in the sensor evaluation system. Multisensor toxic gas monitors from two manufacturers were evaluated using this system. In general, the sensor responses satisfactorily tracked the real-time concentrations of toxic gases in a dynamic mixture. Interferences from a number of organic combustion products including acetaldehyde and bisphenol-A were minimal. Hydrogen bromide in the products of circuit board combustion registered as hydrogen chloride. The use of actual polymer combustion atmospheres for the evaluation of sensors can provide additional confidence in the reliability of the sensor response.

Delgado, Rafael H.↗

Process Analyzer

The ChemScan UV-6100 is a spectrometry system originally developed by Biotronics Technologies, Inc. under a Small Business Innovation Research (SBIR) contract. It is marketed to the water and wastewater treatment industries, replacing "grab sampling" with on-line data collection. It analyzes the light absorbance characteristics of a water sample, simultaneously detects hundreds of individual wavelengths absorbed by chemical substances in a process solution, and quantifies the information. Spectral data is then processed by ChemScan analyzer and compared with calibration files in the system's memory in order to calculate concentrations of chemical substances that cause UV light absorbance in specific patterns. Monitored substances can be analyzed for quality and quantity. Applications include detection of a variety of substances, and the information provided enables an operator to control a process more efficiently.

Source record↗

Revalidation of the Volatile Organic Analyzer Following a Major On-Orbit Maintenance Activity

The Volatile Organic Analyzer (VOA) contributes to the assessment of air quality aboard the International Space Station (ISS) by identifying and quantifying target airborne volatile organic contaminants in the module air. This on-orbit contaminant monitoring capability becomes particularly important during an air quality degradation event such as a system leak. During several ISS air quality degradations, the VOA has generated near real-time data that was used to make decisions or to better understand the contingency. The VOA was operational from January 2002 through June 2003, during which time it was validated by comparing VOA data to simultaneously acquired grab sample containers (GSCs). In January 2003, one of the two analytical channels of the VOA was shutdown because of a component failure, but a redundant channel continued to supply the necessary analytical data. In June 2003, the sole remaining channel was deactivated. Initial assessments of the channel shutdowns pointed to failed fuses or heaters, but neither was considered repairable on orbit. In 2005, it was determined that failed fuses could be replaced on orbit and the crew conducted a diagnostic procedure to identify the failed component. The crew discovered that both channels incurred failed fuses, which lead to a subsequent on orbit maintenance activity and return of the VOA to operational status in December 2005. The VOA has been providing data on the ISS atmosphere since its reactivation in 2005 and this paper will present the VOA data collected during 2006. Special emphasis will be placed upon the revalidation of the repaired VOA using GSCs as well as a summary of the diagnostic and repair procedures.

Limero, Thomas↗

ANITA Air Monitoring on the International Space Station: Results Compared to Other Measurements

ANITA (Analysing Interferometer for Ambient Air) is a flight experiment precursor for a permanent continuous air quality monitoring system on the ISS (International Space Station). For the safety of the crew, ANITA can detect and quantify quasi-online and simultaneously 33 gas compounds in the air with ppm or sub-ppm detection limits. The autonomous measurement system is based on FTIR (Fourier Transform Infra-Red spectroscopy). The system represents a versatile air quality monitor, allowing for the first time the detection and monitoring of trace gas dynamics in a spacecraft atmosphere. ANITA operated on the ISS from September 2007 to August 2008. This paper summarizes the results of ANITA s air analyses with emphasis on comparisons to other measurements. The main basis of comparison is NASA s set of grab samples taken onboard the ISS and analysed on ground applying various GC-based (Gas Chromatography) systems.

Honne, A.↗

Revised Toxicological Assessment of ISS Air Quality: May 2012 - August 2012

A summary of the analytical results from 12 grab sample containers (GSCs) collected on ISS and returned aboard 30S is shown in Table 1. The average recoveries of the 3 surrogate standards from the GSCs were as follows: 12C-acetone, 115 +/-- 11%; fluorobenzene, 108 +/- 8%; and chlorobenzene, 102 +/- 16%. Shaded rows indicate data that re limited due to low sample pressures. For completeness, previously reported data from the US Lab collected in May 2012 are included here as well. The revised report provides results from one returned sample that was unlabeled and originally assumed to be unused. The sample was prepared and analyzed for the purpose of measuring the surrogate compounds. It was later determined, based on serial number, that this was the HTB3 first ingress sample.

Meyers, Valerie↗

Toxicological Assessment of ISS Air Quality: September 2012 - October 2012 with Formaldehyde Supplement from May-October 2012

A summary of the analytical results from 6 grab sample containers (GSCs) and 12 pairs of formaldehyde badges collected on ISS and returned aboard 29S or 31 S is shown in an accompanying table. The average recoveries of the 3 surrogate standards from the GSCs were as follows: C-l3-acetone, 128%; fluorobenzene, 114%; and chlorobenzene, 78%. Recoveries of two lab-control formaldehyde badges averaged 95%.

James, John T.↗

Toxicological Assessment of ISS Air Quality: SpaceX-2 First Ingress

One mini-grab sample container (M-GSC) was collected by crew members onboard ISS during first ingress into SpaceX-2 on March 3, 2013, three days after late cargo loading and a pre-launch clean air purge. Recoveries of the three surrogate standards from the m-GSC were: 13C-acetone, 97%; fluorobenzene, 95%; and chlorobenzene, 68%.

Meyers, Valerie↗

Toxicological Assessment of ISS Air Quality: April - May 2013

A summary of the analytical results from 4 mini-grab sample (mGSCs) collected on ISS and returned aboard 33S is shown in Table 1. Due to the launch delay of the ATV4 resupply mission, monthly samples were reduced in April and May by omitting sampling of the Service Module in order to ensure contingency samplers were available if needed. Complete data tables of all measured concentrations and corresponding T-values based on 180-day SMACs are enclosed. detection limit for all target compounds, except m/p-xylenes and hexachloro-1, 3-butadiene was 0.025 mg/cu m. The detection limit for m/p-xylenes and hexachloro-1, 3-butadiene and all non-target compounds was 0.05 mg/cu m. The average recoveries of the 3 surrogate standards from the mGSCs were as follows: C-13-acetone, 116 +/- 12%; D-5-fluorobenzene, 117 +/- 7%; and D-5-chlorobenzene, 111 +/- 15%. Initial measured sample pressures were between 13.9 and 14.1 psia for all samples, indicating nominal sample collection. A summary of the analytical results from 3 pairs of passive-diffusion formaldehyde badges collected on ISS and returned aboard 33S is also provided in Table 1. In an effort to conserve samples due to the delay of the ATV4 resupply mission, FMK sampling was only conducted in the US Lab in May. Positive control recoveries (1 trip and 2 lab controls) were 79%, 87%, and 116% respectively.

Meyers, Valerie↗

Toxicological Assessment of ISS Air Quality: June - September 2013 (Increment 36)

Fourteen mini grab sample containers (msGSCs) were collected on ISS between June and September 2013 and were returned on 34S; however, the ATV-4 first ingress mGSC did not contain sufficient sample to report results (initial sample pressure = 1.2 psia). Of the remaining 13 mGSCs, 12 were collected as routine monthly samples in the Russian Service Module (SM), US Laboratory (Lab), and either the Japanese Pressurized Module (JPM) or the Columbus module (Col), and 1 was collected during HTV-4 first ingress. A summary of the analytical results from the 13 valid mGSCs is shown.

Meyers, Valerie↗

Overview of the International Space Station’s Water and Cabin Air Quality: A Five-Year Status

Since the beginning of the International Space Station (ISS), water and air quality have been monitored to ensure crew health and verify the performance of the regenerative Environmental Control and Life Support (ECLS) systems. Over the last 25 years, the ISS has evolved greatly with significant changes to operations, crew complement sizes, visiting vehicles, payloads, and upgrades within the regenerative hardware, seen through Technology Demonstration integrations. In particular, better assessment and prevention of volatile organic releases from payloads and crew hygiene products, and implementation of advanced sorbents both on the air and water strings have been successful in reducing contaminant loads. Data on air and water quality for the last five years on ISS will be presented (nominal and contingency air grab samples, in-flight monitoring for air and water quality, and water samples from all segments of the ISS water system), including some notable events. The available data demonstrate the performance of existing ECLS systems and overall status of how the approach to air and water quality have evolved through the new ISS architecture baseline operations.

air quality↗

New estimates of nitrous oxide emissions from biomass burning

The recent discovery of an artifact producing increased levels of N2O in combustion gas samples collected and stored in grab bottles before chemical analysis has resulted in the downgrading of fossil-fuel combustion and the questioning of biomass burning as important sources of N2O. As almost all reported analyses of N2O produced from biomass burning have involved essentially the same collection and analysis protocols as used in the fossil-fuel studies, this source of N2O must also be reexamined. Here, measurements of N2O made over a large prescribed fire using a near real-time in situ measurement technique are reported and compared with measurements of N2O from simultaneously collected grab-bottle samples. The results from 27 small laboratory biomass test fires are also used to help clarify the validity of earlier assessments. It is concluded that biomass burning contributes about seven percent of atmospheric N2O, as opposed to earlier estimates of several times this value.

Cofer, W. R., III↗

Selection and Assessment of Predictions of the Mars Pathfinder Landing Site

The successful landing of the Mars Pathfinder spacecraft on Mars allows the review of the process of selecting the landing site and assessing predictions made for the site based on Viking and Earth-based data. Selection of the landing site for Mars Pathfinder was a two-phase process. The first phase took place from October 1993 to June 1994 and involved: initial identification of engineering constraints, definition of environmental conditions at the site for spacecraft design, and evaluation of the scientific potential of different landing sites. This phase culminated with the first "Mars Pathfinder Landing Site Workshop", held at the Lunar and Planetary Institute in Houston, Texas on April 18-19, 1994, in which suggested approaches and landing sites were solicited from the entire scientific community. A preliminary site was selected by the project for design purposes in June 1994. The second phase took place from July 1994 to March 1996 and involved: developing criteria for evaluating site safety using images and remote sensing data, testing of the spacecraft and landing subsystems (with design improvements) to establish quantitative engineering constraints on landing site characteristics, evaluating all potential landing sites on Mars, and certification of the site by the project. This phase included a second open workshop, "Mars Pathfinder Landing Site Workshop II: Characteristics of the Ares Vallis Region and Field Trips in the Channeled Scabland, Washington" held in Spokane and Moses Lake September 24-30, 1995 and formal acceptance of the site by NASA Headquarters. Engineering constraints on Pathfinder landing sites were developed from the initial design of the spacecraft and the entry, descent and landing scenario. The site must be within 5 degrees of the subsolar latitude at the time of landing (15N for maximum solar power and flexible communications with Earth. It also must be below 0 km elevation to enable enough time for the parachute to bring the lander to the proper terminal velocity for landing. The entire landing ellipse, which is 70 km by 200 km due to navigational, ephemeris and atmospheric uncertainties, must be free of steep slopes, scarps and obvious hazards in Viking orbiter images, have acceptable radar reflectivity, moderate rock abundances and have little or no dust. Scientific considerations of the Mars Pathfinder payload and mission indicate that analyses of "grab bag" samples at the mouths of outflow channels can offer a first order assessment of a variety of rock types on Mars. Highland sites offer the advantage of in situ analysis of ancient rocks on Mars that record crustal differentiation and the nature of the early environment. Dark gray sites offer the potential of analyzing unweathered and unoxidized materials. Following a general assessment of the safety of different sites, a preliminary selection of a "grab bag" site was made. This site, Ares Vallis, is near the mouth of an outflow channel that may contain ancient Noachian terrain, Hesperian ridged plains, and reworked channel materials. All potential landing sites on Mars that met basic safety criteria were analyzed in detail. Sites (100 by 200 km target ellipses) were considered safe if they were below 0 km elevation, were free of obvious hazards (high relief surface features) in high-resolution (< 50 m/pixel) Viking orbiter images and had acceptable reflectivity and roughness at radar wavelengths, high thermal inertia, moderate rock abundance, low red to violet ratio, and low albedo. Only 4 sites on Mars met all the above criteria, which included 1995 opposition 3.5 cm delay-Doppler radar data. Complete data were evaluated for 7 sites and the Viking landing sites for comparison for all the above criteria as well as crater abundance, hill and mesa abundance, slopes over meter to kilometer scales, low altitude winds (from global circulation models and slopes), the size-frequency distribution of large rocks, as well as rover trafficability and science potential. Discussion of potential hazards at Ares Vallis using a variety of data sets (including radar) at a second open workshop, indicated this site cannot be shown to be any more hazardous than the Viking landing sites. Field trips to the Channeled Scabland and the Ephrata Fan, analogs for Ares Vallis and the landing site, respectively, provided valuable insight into possible geologic processes and potential surface characteristics. Three sites met all the data requirements and safety criteria for landing Pathfinder. Ares Vallis was selected by the project because it appeared acceptably safe (although it appeared to have greater rock abundances than other sites, its elevation was likely the best known) and offered the prospect of analyzing a variety of rock types expected to be deposited by catastrophic floods, which would enable addressing first-order scientific questions such as differentiation of the crust, the development of weathering products, and the nature of the early martian environment and its subsequent evolution. The selection was reviewed by an external board at a number of meetings and accepted, and the site was approved by NASA Headquarters. Data gathered by the Pathfinder lander' and rover provides the opportunity to test the predictions made for the site in the selection process based on remote observations from Earth, orbit, and the surface. The discussion below is taken from Golombek et al. to which the reader is referred for a more complete discussion and a complete list of references, which are omitted here for brevity. Many characteristics of the landing site are consistent with its being shaped and deposited by the Ares and Tiu catastrophic floods. The rocky surface is consistent a depositional plain comprising semi-rounded pebbles, cobbles and tabular boulders (some of which appear imbricated and/or inclined in the direction of flow) that appear similar to depositional plains in terrestrial catastrophic floods. The Twin Peaks appear to be streamlined hills in lander images, which is consistent with interpretations of larger hills in Viking orbiter images of the region that suggest the lander is on the flank of a broad, gentle ridge trending northeast from Twin Peaks. This ridge, which is the rise to the north of the lander, is aligned in the downstream direction from the Ares and Tiu Valles floods, and may be a debris tail deposited in the wake of the Twin Peaks. Channels visible throughout the scene may be a result of late stage drainage. As predicted by delay-Doppler radar measurements and tracking results, the average elevation of the center of the site was about the same as Viking Lander I relative to the 6.1 mbar geoid. The Doppler tracking and two-way ranging estimate for the elevation of the spacecraft is only 45 in lower than the Viking I Lander and within 100 in of that expected, which is within the uncertainties of the measurements. After landing, surface pressures and winds (5-10 m/s) were found to be similar to expectations based on Viking data, although temperatures were about 10 K warmer. The temperature profile below 50 km was also roughly 20 K warmer. As a result, predicted densities were 5% higher near the surface and up to 40% lower at 50 km but within the entry, descent and landing design margins. The populations of craters and small hills and the slopes of the hills measured in high-resolution (38 m/pixel) Viking orbiter images and the radar derived slopes of the landing site are all consistent with observations of these properties in the lander images. A rocky surface was expected from Viking Infra-Red Thermal Mapper (IRTM) observations and comparisons with the Viking landing sites. The observed cumulative fraction of area covered by rocks with diameters greater than 3 cm and heights greater than 0.5 in (potentially hazardous to landing) at Ares is similar to that predicted by IRTM observations and models of Viking lander and Earth analog rock size-frequency distributions. The IRTM prediction postulated an effective thermal inertia of 30 (10(exp -3) cgs units - cal/cubic cm/s(exp 0.5)/K) for the rock population, but we obtain a slightly different effective thermal inertia for the actual rock population. The validity of interpretations of radar echoes prior to landing are supported by a simple radar echo model, an estimate of the reflectivity of the soil from its bulk density, and the fraction of area covered by rocks. In the calculations, the soil produces the quasi-specular echo and the rocks produce the diffuse echo. The derived quasispecular cross section is comparable to the cross-sections and reflectivities reported for 3.5-cm wavelength observations. The model yields a diffuse echo that is modestly larger than the polarized diffuse echo reported for 3.5-cm wavelength observations. At 12.5-cm wavelength, similar rock populations at Ares and the Viking I site were expected because the diffuse echoes are comparable, but the large normal reflectivities suggests that bulk densities of the soils at depth are greater than those at the surface. We also obtain a fine-component inertia near 8.4 which agrees with the fine-component inertia of 8.7 (in 10(exp -3) cgs units) estimated from thermal observations from orbit by the IRTM; for this estimate, we used a bulk thermal inertia of 10.4 for the landing site, an effective thermal inertia near 40 (10(exp -3) cgs units) for the rock population, and a graphical representation of Kieffer's model. Color and albedo data for Ares suggested surfaces of materials at Ares Vallis would be relatively dust free or unweathered prior to landing compared with the materials at the Viking landing sites. This suggestion is supported by the abundance of relatively dark-gray rocks at Ares and their relative rarity at the Viking landing sites, where rocks are commonly coated with bright red dust. Finally, the 40 km long Ephrata Fan of the Channeled Scabland in Washington state, which was deposited where c

Golombek, M. P.↗

A Portable Electronic Nose for Toxic Vapor Detection, Identification, and Quantification

The Space Program and military use large quantities of hydrazine and monomethyl hydrazine as rocket propellant, which are very toxic and suspected human carcinogens. Current off-the-shelf portable instruments require 10 to 20 minutes of exposure to detect these compounds at the minimum required concentrations and are prone to false positives, making them unacceptable for many operations. In addition, post-mission analyses of grab bag air samples from the Shuttle have confirmed the occasional presence of on-board volatile organic contaminants, which also need to be monitored to ensure crew safety. A new prototype instrument based on electronic nose (e-nose) technology has demonstrated the ability to qualify (identify) and quantify many of these vapors at their minimum required concentrations, and may easily be adapted to detect many other toxic vapors. To do this, it was necessary to develop algorithms to classify unknown vapors, recognize when a vapor is not any of the vapors of interest, and estimate the concentrations of the contaminants. This paper describes the design of the portable e-nose instrument, test equipment setup, test protocols, pattern recognition algorithms, concentration estimation methods, and laboratory test results.

Linnell, B. R.↗

Systems overview and design methodology

The mission hardware to support a quarantine procedure for a proposed unmanned Mars sample return mission is described. There are several current options for acquiring a sample from the surface of Mars, ranging from a 'grab-and-run', or undocumented, sample return to a fully documented, selected-site, multisample mission. Although the Orbiting Quarantine Facility conceived was designed for one of the more likely mission plans (a documented collection of many subsamples), the facility is suitable for quarantine testing of the sample regardless of how it is acquired on Mars.

Source record↗

SERENE: Saturn Enceladus Return Explorer with Nuclear Electric Propulsion

A ‘quick’ Enceladus sample return mission concept was developed based on the scientist recommendations at the recent ‘Accelerating Space Science with Nuclear Technology Workshop’. The Nuclear Electric Propulsion spacecraft assumed a follow-on 40 kWe nuclear reactor using the demonstrated 40 kWe Fission Surface Power system, expected in the early 2030s. The NEP vehicle also utilized a set of NEXT-C ion thrusters as well as planned Artemis commercial launchers. By launching the 40 kW NEP vehicle on a Starship and adding the propellants of 15 tankers, the 27t probe could be sent on a direct trajectory to Saturn (no Earth or Jupiter flybys) where NEP was used for Saturn capture, spiral down, spiral up and return to the Earth. A small lander obtained the surface Enceladus sample. Using the 40 kW NEP provided a round-trip time of only 16.5 years. A second option was more attractive from a science perspective whereby the NEP vehicle would deliver a large, 6t chemical lander to low Enceladus orbit where it would grab and return a sample to Earth (similar to the recent Orbilander design but in reverse). After deploying the lander, the NEP vehicle would stay in Saturn space performing a moon tour by orbiting four more moons and mapping the large moon of Titan. This option took slightly longer (18.5 yrs) due to the chemical return leg limitations. Both options demonstrated the agility, payload capability, and sample return goals the workshop recommended. An all-chemical option with two stages was roughly analyzed but took 21.5 yrs and required a Jupiter gravity assist.

Nuclear Electric Propulsion↗

A fast lightstripe rangefinding system with smart VLSI sensor

The focus of the research is to build a compact, high performance lightstripe rangefinder using a Very Large Scale Integration (VLSI) smart photosensor array. Rangefinding, the measurement of the three-dimensional profile of an object or scene, is a critical component for many robotic applications, and therefore many techniques were developed. Of these, lightstripe rangefinding is one of the most widely used and reliable techniques available. Though practical, the speed of sampling range data by the conventional light stripe technique is severely limited. A conventional light stripe rangefinder operates in a step-and-repeat manner. A stripe source is projected on an object, a video image is acquired, range data is extracted from the image, the stripe is stepped, and the process repeats. Range acquisition is limited by the time needed to grab the video images, increasing linearly with the desired horizontal resolution. During the acquisition of a range image, the objects in the scene being scanned must be stationary. Thus, the long scene sampling time of step-and-repeat rangefinders limits their application. The fast range sensor proposed is based on the modification of this basic lightstripe ranging technique in a manner described by Sato and Kida. This technique does not require a sampling of images at various stripe positions to build a range map. Rather, an entire range image is acquired in parallel while the stripe source is swept continuously across the scene. Total time to acquire the range image data is independent of the range map resolution. The target rangefinding system will acquire 1,000 100 x 100 point range images per second with 0.5 percent range accuracy. It will be compact and rugged enough to be mounted on the end effector of a robot arm to aid in object manipulation and assembly tasks.

Gruss, Andrew↗