Search NASA⌕ Search

SEARCH · Search NASA

Results for “graphite characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Microstructural characterization of nuclear graphite: from the microscale to the nanoscale

Multiple reactor designs use graphite as a moderator of the nuclear reactions and as structural support. During the lifetime of the reactor, multiple aging factors such as neutron irradiation, oxidation, and temperature along with others induce changes in the microstructure and crystal lattice of graphite components. The pore morphology and crystal structure of some phases in graphite can be used to trace the evolution of irradiation defects and mechanical properties of graphite. We present a combination of results from several microscopy techniques to investigate the differences between nuclear graphite grades and the effects of neutron irradiation and oxidation at multiple length scales. This multiscale approach is needed to understand the microstructural variations caused by the raw materials and manufacturing processes as well as how the different phases of graphite are affected by the reactor environment. The results provide insight into the oxidation- and radiation-induced changes of graphite and create a robust baseline of microstructure information that can be used for the selection of materials for the next generation of nuclear power stations. Moreover, the experiments conducted in this work provide an overview of the advantages and limitations of the most common techniques used to characterize nuclear graphite and how these techniques might be applied to study other carbon-based materials used in the nuclear industry.

Arregui Mena, Jose'↗

Characterization of nuclear graphite elastic properties using laser ultrasonic methods

Laser ultrasonic methods have been used to characterize the elastic behaviors of commercially-available and legacy nuclear graphites. Since ultrasonic techniques are sensitive to various aspects of graphite microstructure including preferred grain orientation, microcrack orientation and porosity, laser ultrasonics is a candidate technique for monitoring graphite degradation and structural integrity in environments expected in high-temperature, gas-cooled nuclear reactors. Aspects of materials texture can be assessed by studying ultrasonic wavespeeds as a function of propagation direction and polarization. Shear wave birefringence measurements, in particular, can be used to evaluate elastic anisotropy. In this work, laser ultrasonic measurements of graphite moduli have been made to provide insight into the relationship between the microstructures and the macroscopic stiffnesses of these materials. In particular, laser ultrasonic measurements have been made using laser line sources to produce shear waves with specific polarizations. By varying the line orientation relative to the sample, shear wave birefringence measurements have been recorded. Results from shear wave birefringence measurements show that an isostatically molded graphite, such as PCIB, behaves isotropically, while an extruded graphite, such as H-451, displays significant ultrasonic texture. Graphites have complicated microstructures that depend on the manufacturing processes used, and ultrasonic texture in these materials could originate from grain orientation and preferred microcrack alignment. Effects on material isotropy due to service related microstructural changes are possible and the ultimate aim of this work is to determine the degree to which these changes can be assessed nondestructively using laser ultrasonics measurements

anisotropy↗

Generation of graphite particles by sliding abrasion and their characterization

Characterization of graphite particles (dust) produced by abrasion that would occur in a pebble bed reactor is of interest for reasons of safety, operation, and maintenance. To better understand this abrasion and particle generation, we have built a test apparatus to produce particles by sliding abrasion in a 1% to 5% relative humidity air environment. We have used a commercial-grade graphite in our experiments and have generated size distributions for the abraded particles. We have also fit lognormal functions to those size distributions (for use in computer codes); determined particle shapes; measured temperature and humidity during the tests; measured and calculated wear rates; and measured the surface roughness of both pretest and posttest samples, particle surface areas, pore volumes, and pore volume distributions of particles produced during abrasion of graphite surfaces under different loadings and sliding speeds. The experiments showed that as loading (analogous to pebble depth in the reactor) and sliding speed increase, so do the wear rates and numbers of particles produced, while surface roughness decreases, increases, and then decreases. Brunauer-Emmett-Teller measurements show that abrasion increases surface area from 0.583 m 2 /g in the bulk material to 555 m 2 /g in material abraded at high loading and high sliding speed. Wear rates range from 0.005 to 0.991 g/m per contact site. As a result, the size of the particles observed was <4000 nm. Finally, in all, our research shows that pebble abrasion is a complex process that is not constant during operation and thus should be considered for future work.

36 MATERIALS SCIENCE↗

Kelvin probe characterization of buried graphitic microchannels in single-crystal diamond

In this work, we present an investigation by Kelvin Probe Microscopy (KPM) of buried graphitic microchannels fabricated in single-crystal diamond by direct MeV ion microbeam writing. Metal deposition of variable-thickness masks was adopted to implant channels with emerging endpoints and high temperature annealing was performed in order to induce the graphitization of the highly-damaged buried region. When an electrical current was flowing through the biased buried channel, the structure was clearly evidenced by KPM maps of the electrical potential of the surface region overlying the channel at increasing distances from the grounded electrode. The KPM profiling shows regions of opposite contrast located at different distances from the endpoints of the channel. This effect is attributed to the different electrical conduction properties of the surface and of the buried graphitic layer. The model adopted to interpret these KPM maps and profiles proved to be suitable for the electronic characterization of buried conductive channels, providing a non-invasive method to measure the local resistivity with a micrometer resolution. The results demonstrate the potential of the technique as a powerful diagnostic tool to monitor the functionality of all-carbon graphite/diamond devices to be fabricated by MeV ion beam lithography.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Report on initial development of a database of nuclear graphite characteristics based on microstructural characterization

This report outlines the current and future efforts to produce a comprehensive library of microstructures of nuclear graphite and carbon-based materials that are candidate materials for nuclear applications in the United States. This library must contain extensive characterizations of unirradiated graphite materials, a guide to some of the techniques used to characterize graphite, a compendium of characterization data of neutron-irradiated or oxidized material, and a compendium of microstructural information of carbon-based materials. These characterization efforts are being conducted at various length scales to understand these complex materials’ local structure and property relationships. Achieving this goal requires further developing or adapting advanced characterization techniques that capture graphite’s most relevant characteristics. Some of the general objectives of this project are to aid with the material selection, licensing, management, and core assessments of a graphite core by documenting the unirradiated microstructure of relevant grades or by characterizing the evolution of the microstructure under the reactor environment. Moreover, this project aims to provide additional information, guidelines for characterizing graphite, and a protocol to assess a nuclear graphite grade. This report also summarizes some of the initial results and some of the techniques commonly used to characterize nuclear graphite.

36 MATERIALS SCIENCE↗

Machining Graphite Specimens from Sub- Blocks for Baseline Characterization

The Advanced Reactor Technologies (ART) Baseline Graphite Characterization program at the Idaho National Laboratory (INL) is performing a comprehensive evaluation of inter-billet variations in as-produced nuclear-grade graphite. To accomplish this, over 500 mechanical test specimens are machined from a single billet. A typical graphite billet is approximately 6 feet long by 2 feet in diameter or 2 ft square and weighs approximately 1500 pounds. Initially the full-size billets are pre-sectioned into sub-blocks that can be easily handled and shipped. In this SOW, 44 pre-labeled sub-blocks will be machined into mechanical test specimens by the supplier. These sub-blocks are supplied and shipped by the purchaser to the supplier.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Advanced Surface and Microstructural Characterization of Natural Graphite Anodes for Lithium Ion Batteries

Natural graphite powders were subjected to a series of thermal treatments in order to improve the anode irreversible capacity loss (ICL) and capacity retention during long-term cycling of lithium ion batteries. A baseline thermal treatment in inert Ar or N2 atmosphere was compared to cases with a proprietary additive to the furnace gas environment. This additive substantially altered the surface chemistry of the natural graphite powders and resulted in significantly improved long-term cycling performance of the lithium ion batteries over the commercial natural graphite baseline. Different heat-treatment temperatures were investigated ranging from 950-2900 C with the intent of achieving the desired long-term cycling performance with as low of a maximum temperature and thermal budget as possible. A detailed summary of the characterization data is also presented, which includes X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), Raman spectroscopy, and temperature-programed desorption mass spectroscopy (TPD-MS). This characterization data was correlated to the observed capacity fade improvements over the course of long-term cycling at high charge-discharge rates in full lithium-ion coin cells. It is believed that the long-term performance improvements are a result of forming a more stable solid electrolyte interface (SEI) layer on the anode graphite surfaces, which is directly related to the surface chemistry modifications imparted by the proprietary gas environment during thermal treatment.

Gallego, Nidia C↗

Carbon Characterization Laboratory Readiness to Receive Irradiated Graphite Samples

The Carbon Characterization Laboratory (CCL) is located in Labs C19 and C20 of the Idaho National Laboratory Research Center. The CCL was established under the Next Generation Nuclear Plant Project to support graphite and ceramic composite research and development activities. The research conducted in this laboratory will support the Advanced Graphite Creep experiments—a major series of material irradiation experiments within the Next Generation Nuclear Plant Graphite program. The CCL is designed to characterize and test low activated irradiated materials such as high purity graphite, carbon-carbon composites, silicon-carbide composite, and ceramic materials. The laboratory is fully capable of characterizing material properties for both irradiated and nonirradiated materials. Major infrastructural modifications were undertaken to support this new radiological facility at Idaho National Laboratory. Facility modifications are complete, equipment has been installed, radiological controls and operating procedures have been established and work management documents have been created to place the CCL in readiness to receive irradiated graphite samples.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SIMS and HR-XPS characterization of lithiated graphite from the magnetic fusion device RFX-mod

Lithium wall conditioning has improved the performance of many magnetic fusion devices. Li conditioning in the RFX-mod device was performed by: (1) a single Li pellet injector and (2) a multi-Li pellet injector during He plasma discharges; (3) a Li evaporator after He glow discharge cleaning and He plasma discharge exposure. This report compares the spatial and depth distributions of Li deposited on polycrystalline graphite witness samples at different locations in RFX-mod and the elemental and chemical compositions of the resulting surfaces. The sample surfaces were analyzed ex situ using secondary ion mass spectrometry (SIMS) and high-resolution X-ray photoelectron spectroscopy (HR-XPS). The results showed that Li pellet injection provided a relatively uniform toroidal coverage while Li evaporation produced highly localized Li deposition. A Li 1s HR-XPS peak at 56.5 eV binding energy (BE) characteristic of lithium-intercalated graphite was only observed with the sample exposed to Li evaporation. All of the samples exhibited a HR-XPS C 1s peak at 285.1–285.2 eV BE that is largely attributed to hydrogenated graphite. This finding suggests that hydrogenation of fresh graphite occurs during He plasma discharge exposures. Finally, our results have implications for density control and the selection of Li conditioning techniques in magnetic fusion devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization of Mechanical Properties of Nuclear Graphite Using Subsize Specimens and Reusing Tested Specimens

The mechanical properties of NBG-18 nuclear grade graphite have been characterized using small specimen test techniques and statistical treatment on the test results. New fracture strength and toughness test techniques were developed to use subsize cylindrical specimens with glued heads and to reuse their broken halves. Three sets of subsize cylindrical specimens with the different diameters of 4 mm, 8 mm, and 12 mm were tested to obtain tensile fracture strength. The longer piece of the broken halves was cracked from side surfaces and tested under three-point bend loading to obtain fracture toughness. Both the strength and fracture toughness data were analyzed using Weibull distribution models focusing on size effect. The mean fracture strength decreased from 22.9 MPa to 21.5 MPa as the diameter increased from 4 mm to 12 mm, and the mean strength of 15.9 mm diameter standard specimen, 20.9 MPa, was on the extended trend line. These fracture strength data indicate that in the given diameter range the size effect is not significant and much smaller than that predicted by the Weibull statistics-based model. Further, no noticeable size effect existed in the fracture toughness data, whose mean values were in a narrow range of 1.21 1.26 MPa. The Weibull moduli measured for fracture strength and fracture toughness datasets were around 10. It is therefore believed that the small or negligible size effect enables to use the subsize specimens and that the new fracture toughness test method to reuse the broken specimens to help minimize irradiation space and radioactive waste.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Study of Tritium Transport in Nuclear-Grade Graphite and Molten Fluoride Salt Systems

High-temperature salts are proposed as coolant in recent reactor technologies including Fluoride Salt-Cooled High Temperature Reactor (FHR) with fluoride salt as primary and secondary loop coolant, Molten Salt Reactors (MSRs) with fuel salt, and high-magnetic-field fusion machines with salt coolant blanket. The baseline coolant is {sup 7}Li{sub 2}BeF{sub 4} (flibe) due to its good thermal-hydraulic and neutronic properties. Tritium produced in flibe due to neutron irradiation makes the issue of tritium transport an area of great interest. In the temperature range of 427- 704 deg. C, tritium readily diffuses through metallic reactor structural materials, which makes tritium control and capture a key technical challenge. It is anticipated that tritium can be captured by graphite, as graphite material showed a high affinity for tritium in the Molten Salt Reactor Experiment (MSRE) due to the porous and irregular crystallite microstructure. Two types of nuclear grade graphite which used as core components for FHR: matrix graphite, which encapsulates the TRISO (Tri-structural-isotropic) fuel particles in FHR, and high purity, isotropic nuclear grade graphite IG-110 which can be used as moderator and reflector in reactor core for both fission and fusion reactor. The microstructure of matrix graphite and IG-110 is different from that of matrix graphite, due to the raw material and manufacturing processes. There are three phenomena important for predicting tritium transport in graphite-salt systems: tritium species diffusion in molten flibe; tritium species transport at the salt-graphite interface; and tritium species transport in graphite. In this summary microstructure characterization of IG-110 and matrix graphite, characterization of graphite-salt interface as well as techniques for trace tritium detection in graphite are discussed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Pre-conceptual Development and characterization of an extruded graphite composite fuel for the TREAT Reactor

In an effort to explore fuel systems that are more robust under accident scenarios, the DOE-NE has identified the need to resume transient testing. The Transient Reactor Test (TREAT) facility has been identified as the preferred option for the resumption of transient testing of nuclear fuel in the United States. In parallel, NNSA’s Global Threat Reduction Initiative (GTRI) Convert program is exploring the needs to replace the existing highly enriched uranium (HEU) core with low enriched uranium (LEU) core. In order to construct a new LEU core, materials and fabrication processes similar to those used in the initial core fabrication must be identified, developed and characterized. In this research, graphite matrix fuel blocks were extruded and materials properties of were measured. Initially the extrusion process followed the historic route; however, the project was expanded to explore methods to increase the graphite content of the fuel blocks and explore modern resins. Materials properties relevant to fuel performance including density, heat capacity and thermal diffusivity were measured. The relationship between process defects and materials properties will be discussed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Baseline Graphite Initial Mechanical Test Report

The Next Generation Nuclear Plant (NGNP) Project is tasked with selecting a high temperature gas reactor technology that will be capable of generating electricity and supplying large amounts of process heat. The NGNP is presently being designed as a helium-cooled high temperature gas reactor (HTGR) with a large graphite core. The graphite baseline characterization project is conducting the research and development (R&D) activities deemed necessary to fully qualify nuclear-grade graphite for use in the NGNP reactor. One of the major fundamental objectives of the project is establishing nonirradiated thermomechanical and thermophysical properties by characterizing lot-to-lot and billet-to-billet variations (for probabilistic baseline data needs) through extensive data collection and statistical analysis. The reactor core will be made up of stacks of graphite moderator blocks. In order to gain a more comprehensive understanding of the varying characteristics in a wide range of suitable graphites, any of which can be classified as “nuclear grade,” an experimental program has been initiated to develop an extensive database of the baseline characteristics of numerous candidate graphites. Various factors known to affect the properties of graphite will be investigated, including specimen size, spatial location within a graphite billet, specimen orientation within a billet (either parallel to [P] or transverse to [T] the long axis of the as-produced billet), and billet-to-billet variations within a lot or across different production lots. Because each data point is based on a certain position within a given billet of graphite, particular attention must be paid to the traceability of each specimen and its spatial location and orientation within each billet. The evaluation of these properties is discussed in the Graphite Technology Development Plan (Windes et. al 2007). One of the key components in the evaluation of these graphite types will be mechanical testing of specimens drawn from carefully controlled sections of each billet. This report is confirmation that the test procedures are in place and approved, and that mechanical testing of graphite under the Baseline Graphite Characterization program has commenced.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Summary of Graphite Data Stored within NDMAS

The Graphite Technology Development Project provides data to support the design of graphite core components within specific reactor service conditions of the next generation of high-temperature, gas-cooled nuclear reactors. Physical, mechanical, and thermal properties of nuclear grade graphite were characterized for specimens that were unirradiated, irradiated, and irradiated under various stress conditions. The material properties include diameter, length, mass, density, compressive strength, tensile strength, flexural strength, modulus, resistivity, thermal diffusivity, and thermal expansion coefficient. Baseline graphite specimens are unirradiated from different grades (2114, IG-110, NBG-17, NBG-18, and PCEA) and different types used in different characterization tests (compressive, flexural, tensile, one-inch cylinder, and quarter-inch cylinder). The Advanced Graphite Creep (AGC) irradiation specimens are from a much larger number of grades and cylinder types (creep, piggyback, and pencil). For baseline graphite, characterization data for 7,756 specimens extracted from thirteen graphite billets were captured to the NDMAS database. For AGC experiments, four irradiation campaigns have been completed: AGC-1, AGC-2, AGC-3, and AGC-4. The ongoing HDG-1 (High-Dose Graphite) experiment, which began irradiation with Cycle 168B on August 26, 2020, includes specimens previously irradiated in AGC-2 in addition to the specimens originally destined for AGC-5.. Besides the characterization data, the AGC data includes irradiation monitoring and physics data representing the irradiation conditions of AGC specimens. Currently, all data for AGC-1, AGC-2, and AGC-3 have been captured to the NDMAS database. Only AGC-4 pre-irradiation and irradiation monitoring data have been captured, and HDG-1 pre-irradiation data are in process of being captured for unirradiated specimens. To date, a total of 38,149 material property records have been captured into NDMAS database for baseline and AGC specimens. All characterization data are qualified for use according to their perspective data verification reports. For the AGC irradiation campaigns, a total of 41,502 qualified physics calculation records were added for AGC-1, AGC-2, and AGC-3. Finally, a total of 173,698,505 AGC irradiation monitoring data records (thermocouple temperature, gas flow rate, gas pressure, gas moisture, applied load, and specimen displacement) have been captured to NDMAS; the majority of those records (~94%) are qualified data records.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Ytterbium Ion Collection on Graphite Plates

Surface characterization and analysis of the graphite collection and strike plates was conducted in this report. These plates were from an electromagnetic isotope separation collector that had been irradiated with an ytterbium ion beam. The results of this study are reported along with analysis and discussion of the potential growth mechanism of the ytterbium layer on graphite. It is proposed that directional deposition of ytterbium ions occurs first in the defect regions of the graphite plate. As deposition continues, it leads to the eventual formation of directional globs that elongate and grow into plates, then stacks, and finally into sheets of ytterbium. The ytterbium layer appears to have a definite phase boundary with the graphite layer. It was also determined that during irradiation with the ytterbium ion beam, the sputtered carbon becomes interpolated in the ytterbium surface layer on the graphite plate and has an amorphous microstructure.

36 MATERIALS SCIENCE↗