Search NASA⌕ Search

SEARCH · Search NASA

Results for “inlets”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Detailed Design and Cost Estimation of a 300 MWe Oxy-Fuel sCO2 Turbine

The detailed design of a 300 MWe, utility scale oxy-fuel turbine has been completed for purposed operation in the sCO2 direct fired Allam-Fetvedt cycle, targeting near-zero emissions and a 50% LHV system efficiency. The turbine and its supporting plant aim to offer a lower levelized cost of energy than a natural gas combined cycle plant employing carbon capture. The oxy-fuel turbine conditions include an inlet temperature of 1150°C and inlet pressure of 305 bar, representing temperatures near that of a gas turbine simultaneously with pressures near an ultra-supercritical steam turbine. The combustor housing and turbine designs were completed according to the ASME BPVC; the turbine case specifically incorporates a multi-body design with inner high-pressure barrel case and low-pressure (30 bar) horizontally split outer case of low-chromium steel material. Lateral rotordynamic evaluation demonstrated acceptable vibration response for a range of imbalance conditions per API standards. The cooling flow required in the six-stage turbine flowpath for 30,000 hr. blade and stator lifetime is predicted through thermal and structural modeling of the first stage. The provided cost estimate of the turbine is formed through a combination of scaled up-costs from procured 10 MWe scale sCO2 turbomachinery hardware, and vendor provided budgetary quotes of larger components including the turbine case requiring casting, welding, and final machining processes. The performance and cost estimation of the oxy-fuel turbine predicted for the completed detailed design provides important information towards future development needs for market penetration of utility scale direct fired sCO2 power cycles.

Marshall, Michael [Southwest Research Institute, S↗

Experimental Analysis of Advanced Turbine for Supercritical CO2 Power Cycle

An advanced first stage high pressure turbine blade for a supercritical CO2 power cycle is tested in the Big Rig for Aerothermal Stationary Turbine Analysis (BRASTA) annular cascade at the Purdue Experimental Turbine Aerothermal Laboratory (PETAL) high pressure blow down facility alongside a baseline blade for comparison of aerodynamic performance. Both geometries are tested simultaneously using a novel off-axis rig design to allow for the blade geometries to be scaled up to achieve higher Reynolds numbers. The off-axis design necessitates the use of discrete sectors of airfoils, which are designed and additively manufactured in house using an mSLA printer. Printing the blades allows for unique routing of passage for blade surface static pressure taps that contour to the blade shape instead of requiring a straight line view from surface tap to egress, allowing all instrumentation for 15%, 50%, and 85% span to exist in the same passage. A flow conditioning gauze [1] is placed upstream of the blade passages to impart pressure, Mach, and swirl profiles to mimic the rotor relative frame inlet conditions to the blade. Downstream, a sonic valve is used to alter the backpressure to achieve different pressure ratios for different blowdown setpoints. The design of the rig, sonic wheel, and instrumentation are discussed along with the manufacturing and GD&T of the blades with respect to the build-up of this novel experimental apparatus. Initial commissioning data is obtained from inlet total pressure and temperature rakes, blade static pressure taps, and exit total pressure rakes. Oil visualization is performed using a silicone oil mixture containing titanium dioxide and pigmented for contrast of the blade suction side surface with the hub and shroud endwalls. The viscosity of the oil is tuned so that the oil does not fully thin and blow away during the time of the test, and endoscopic cameras are placed in the rig for live monitoring and recording. The preliminary oil visualization and rake profiles are presented, showcasing the operability of this additively manufactured off-axis flow path design.

Tuite, Logan [Purdue University]↗

Determining tolerance requirements for spray-duct alignment in ducted fuel injection

Several ducted fuel injection (DFI) studies have highlighted the importance of accuracy in aligning the duct axis with that of its corresponding spray for optimal effectiveness, as misalignment adversely impacts the method’s performance. The need for accurate alignment could lead to added manufacturing complexity via tighter tolerances. This study systematically explores cases of horizontal, vertical, and rotational misalignment, analyzing their respective effects on DFI performance. Vertical and horizontal misalignments at the duct inlet plane were varied at magnitudes of 6.25%, 12.5%, and 25.0% of the duct diameter, corresponding to 0.125, 0.25, and 0.5 mm, respectively. Rotational misalignments were set at 1°, 2°, and 4°, corresponding to 3.65%, 7.30%, and 14.6%, respectively, of the duct diameter at its inlet plane. The investigation yields spray-duct alignment tolerance limits and highlights the influence of misalignment direction on emissions due to the interactions with swirl and squish inside the combustion chamber. The results indicate that the tolerance limits for the alignment are within 4° and 0.5 mm relative to the geometrically aligned position. If the misalignment exceeds 4°of rotation or 0.5 mm in the horizontal direction, the beneficial effects on soot reduction using this method are no longer observed. The findings contribute to an understanding that can be used to optimize DFI for cleaner and more efficient combustion in compression-ignition engines.

Şener, Ramazan↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CFD and systems engineering to minimize membrane-based carbon capture costs

In this study, we propose a superstructure for membrane-based carbon capture, addressing these challenges through the formulation of an optimization problem. The case study considers a flue gas with a flowrate of 1000 mol/s and a 30 % CO2 (molar basis), which is representative of steel plants. Reduced models, derived from rigorous CFD simulations of membrane modules, are utilized to enhance the efficiency of the optimization process. The reduced model includes specific input variables such as inlet flow rate, retentate and permeate pressures, and inlet CO2 concentration; while the CO2 recovery and purity in the permeate side are considered as output variables. In this way, we exploit the information from the CFD simulations in the superstructure, aiding in the selection of the optimal configuration for the multi-stage membrane process. The results underscore the efficiency of a multi-stage membrane design, showing capture costs around 45 $/t-CO2.

Pedrozo, Hector A.↗

CharIN Megawatt Charging System: 4 th Event Summary Report

Medium- and heavy-duty electric vehicles require higher charging power levels than are supported by present light-duty EV charging standards. The Charging Interface Initiative (CharIN) Megawatt Charging System (MCS) Task Force is undertaking efforts to develop a new high-power charging standard for medium- and heavy-duty vehicle electrification. The fourth MCS evaluation event at NREL focused on thermal and mechanical performance evaluations of high-power MCS electric vehicle charging connectors and inlets from several different manufacturers, at current levels up to 3000A. Additionally, the event evaluated the performance of a reference inlet design, which will provide a baseline level of thermal performance for use in future evaluation and certification efforts of MCS connectors.

33 ADVANCED PROPULSION SYSTEMS↗

Computational Analysis of Hydraulic Efficiency of Michigan DOT Cover C

Drainage structures are used to capture stormwater runoff in streets and highways in urban environments. These drainage structures, which typically consist of catch basins with grates, inlets, or combination grates/inlets, collect stormwater runoff and discharge through buried conveyance systems. They are strategically placed for public safety in curb and gutter systems to provide efficient drainage of water from roadways and thus reduce the risk of hydroplaning. The performance of drainage structures is measured in terms of hydraulic efficiency, which is defined as the percentage of flow captured by the basin as compared to the total flow drainage to the structure. Understanding of the performance of these drainage structures helps designers properly space inlets to promote an economic design that ensures the safety of the traveling public. The current design methodology used to determine drainage structure follows guidelines established in the current Michigan Department of Transportation (MDOT) Drainage Manual (2006). The guidelines in the MDOT Drainage Manual were modeled after the Federal Highway Administration’s (FHWA) Hydraulic Engineering Circular 22 “Urban Drainage Design” (HEC-22). HEC-22 includes empirically derived equations to calculate the interception capacity of drainage structures for several commonly used grate configurations, such as the parallel bar, curved vane and tilt bar grates, which are based on a research study performed by Burgi et al. in the 1970s. MDOT uses several drainage structures to capture runoff that are detailed as Standard Plans. Many of these drainage structures utilize sinusoidal type grates that are not described in HEC-22. Physical modeling of these structures has been limited, posing the need to have them analyzed to verify their capture efficiency. Current MDOT practice is to assume a similar sized reticuline grate, as described in HEC-22, for capture efficiencies. Until recently, evaluating the hydraulic performance of drainage structures was limited to physical modeling in a hydraulics laboratory. With advances in engineering software and computing power, computational fluid dynamics (CFD) modeling has become a more cost-effective alternative. The Federal Highway Administration (FHWA) provides states the option to evaluate their drainage structures using CFD through the Transportation Pooled Fund Program. This study, “Computational Analysis of Hydraulic Efficiency of Michigan DOT Cover C,” was carried out using the pooled fund. MDOT’s Cover C was chosen as the first test candidate, given its similar sinusoidal pattern to other MDOT grates, but it is typically used for high-volume, higher speed applications. A similar version, Cover CX, is used on interstate highways but does not have traverse bars for bicycle safety. Additional grates may be considered for evaluation in the future.

42 ENGINEERING↗

Ducted Fuel Injection And Cooled Spray Technologies For Particulate Control In Heavy-duty Diesel Engines (Final Report)

Cooled Spray (CS) and Ducted Fuel Injection (DFI) are in-cylinder technologies for diesel engines that can reduce particulate matter and soot emissions and data has been published showing that these technologies can reduce soot emissions by 75-100% for some engines at some operating conditions. However, little is known about scaling the devices for engine size. Additionally, the performance of either technology over the engine duty cycle has not been explored. This project addresses both of these points through single-cylinder engine investigations. The objectives of this project are to provide details about dimensional scaling of these devices and to demonstrate 75% PM reduction over a range of operating conditions on a single-cylinder engine. Two engines were used for this project: a 125mm bore optically accessible engine at Sandia National Laboratories and a 168mm bore metal engine at Southwest Research Institute. The optical engine was used to study the performance of DFI and CS inserts for a large injector orifice diameter injector that is characteristic of a locomotive engine and to perform scaling studies for DFI. The metal engine was used to perform scaling and alignment studies for CS and to evaluate the technology for both EGR and non-EGR engines over the engine operating map. Modifications were required for both engines to accept the prototype inserts being tested. The optical engine required a new fuel injector, cylinder head and piston so that tests could be run at the pressures and engine speeds required. Additionally, a novel rotating stage was designed for the optical engine to simplify alignment of the modules. The metal engine required a modified cylinder head to accept CS inserts and a modified piston to provide additional space around the fuel injector for the CS inserts. Tests on the optical engine showed that DFI reduces PM emissions for both small injector orifices (0.170mm diameter) and large injector orifices (0.290mm). For high load testing, the DFI modules were not as effective as at low load testing, but it was acknowledged that minimal geometric optimization was performed and more improvements may be possible. Comparing DFI to CS and conventional diesel combustion (CDC), DFI performed better than CS or CDC. The CS geometries used in these studies may not be ideal for that engine and additional modifications likely would improve performance. Tests on the metal engine showed PM reductions as high has 80% at some operating conditions with duty-cycle PM reductions of ~50% for EGR and non-EGR configurations. The CS testing on the metal engine showed that chamfering of the fuel passage inlet either through hydro-erosion or mechanical grinding provided significant improvements in the PM reduction capabilities of the insert. Additionally, alignment sensitivities were explored and the data show that the tolerance to misalignment is approximately 0.05 to 0.1mm for the inserts that were studied here. Air-fuel ratio was shown to be important in the effectiveness of the CS inserts. In several tests, it was shown that the CS inserts are more effective at reducing the PM for high-AFR operating conditions compared to low AFR conditions. In summary, multiple designs were evaluated on both engines. It was found that for the conditions and configurations studied here, a fuel passage diameter of ~2.5mm performed best overall. Significant duty-cycle PM reductions are possible using these technologies and sensitivities to AFR, alignment fuel passage diameter and inlet fuel passage shaping were explored and are reported here. More PM reduction may be possible with improved geometric design and attention to alignment practices.

02 PETROLEUM↗

Coastal Cloud Chemistry during EPCAPE Field Campaign Report

For this campaign, Principal Investigator Markus Petters deployed a suite of instruments inside Lynn Russell’s container that was sited at Mt. Soledad during the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE) campaign. Funding for this activity was provided by National Science Foundation Award 2410536. The instrument rack (Figure 1) included a differential mobility analyzer, a condensation particle counter, a portable optical particle spectrometer, and a continuous flow diffusion cloud condensation nuclei counter (CCN). The instruments sampled from a counterflow virtual impactor (CVI) inlet and an isokinetic inlet. The measurements provided aerosol size distribution, size-resolved CCN activity, and denuded versus undenuded CCN activity of aerosols and cloud drop residuals.

54 ENVIRONMENTAL SCIENCES↗

Pressure Gain, Stability, and Operability of Methane/Syngas Based RDEs Under Steady and Transient Conditions (Final Project Report)

The scope of this work addresses key issues associated with losses associated with the detonation wave and other processes internal to the RDE operation, as well as it develops modeling tools for the evaluation of these losses and exhaust emissions in RDEs. The main challenge in studying RDEs is that RDE performance is highly reliant on the specifics of the design so much so that simple/canonical systems alone cannot provide useful engineering information, but practical RDE designs are sufficiently complex and involve extreme operational environments that detailed access either experimentally (laser diagnostics, for instance) or computationally (direct numerical simulations) are as yet to become practical. To overcome this challenge, we have conducted a combined experimental/simulation/analytical study investigating key phenomena that control the characteristics of operation of RDEs. As a result, the study has developed tools and methods that can be used to evaluate performance and design approaches using reduced-physics models, with the assumptions validated using detailed simulations, and the model prediction tested using experimental observations. The specific objectives of the research were: (1) Develop and demonstrate a low-loss fully axial injection concept, taking advantage of stratification effects to alter the detonation structure and position the wave favorably within the combustor; (2) Obtain stability and operability characteristics of an RDE across operating conditions to aid in the development of operability and performance rules for the operations of other systems; and (3) Develop quantitative metrics for performance gain as well as quantitative description of the loss mechanisms through a combination of diagnostics development, reduced-order modeling, and detailed simulations. The work conducted here has made contribution on design of low-loss inlets that has broad application within the power generation industry for use with pressure gain combustion. The operability and stability of different designs, while focusing on axial air inlet designs, has been analyzed. The effect of nozzle and injection conditions was studied. Models and simulations of exhaust emissions, focusing on NOx emission has been developed and used to investigate how operation of the RDE affect NOx production using Lagrangian analysis of RDE simulations. This work has built on previous programs, with the goal of further understanding operation of RDEs and elevate the readiness of design consideration. In addition, a suite of diagnostic and modeling tools have been developed to obtain quantitative metrics on performance based on measurements, which can be readily transferred to other experimental configurations.

08 HYDROGEN↗

Experimental Characterization of High-Surface Area Thermal Energy Storage

There is growing interest in energy storage technologies due to the expansion of renewable energy sources that are inherently intermittent and the increasing frequency of extreme weather events that disturb the power grid. Power consumption in buildings makes up approximately 76% of all electricity usage on the grid and is primarily used for thermal applications such as space conditioning, hot water, and cooking. This makes thermal energy storage (TES) an ideal solution for many of these applications. Many TES technologies rely on latent energy storage, which utilizes the melting/solidification of phase change materials (PCM) to store energy. Typically, TES designs suffer from low power density due to their low inherent thermal conductivity. This limitation makes the deployment of TES in active applications difficult as the ease of access to energy is essential for effective use. Common routes for improving power density include high thermal conductivity additives or extended features such as fins that increase cost. This study presents an alternative approach to improving performance through increasing the overall surface area to volume ratio of the device, to increase the available area for convection to occur between the working fluid and PCM. In the study a commercial PCM was selected with a transition temperature ideal for space heating applications. The heat exchanger design utilizes a unique application of triply periodic minimal surfaces (TPMS) for macro-encapsulation of the PCM. The use of TPMS for heat exchangers has been growing in interest due to their high-surface area to volume ratios, which were previously unmanufacturable until the development of additive manufacturing. A modular system was designed and manufactured with a stereolithography resin printing system that is then backfilled with PCM. An experiment test set-up is designed to test the charge and discharge performance of the thermal storage using a conditioned air stream. The pressure drop of the design is tested across a variety of flow rates. When compared to existing experimental data within literature, there is excellent agreement based on the Reynolds number at similar hydraulic diameters. Several inlet temperatures are tested at consistent temperature differences from the phase change temperature for both charging and discharging. Additionally, the volumetric flow rate is varied for each temperature set point. It was found that increasing flow rate had diminishing returns in reducing the overall charge time of the TES. The temperature delta from the melting temperature was the primary contributor to the change in average heat flux with limited variation in average heat transfer rate between charging and discharging at similar inlet temperatures and flow rates. The TPMS heat exchanger design has a high air-side pressure drop but it provides high heat transfer rates. This helps maintain a high outlet temperature during discharge, which is important to thermal comfort applications. The design, manufacturing, and experimental characterization of the TES device will be presented as part of this study.

25 ENERGY STORAGE↗

Numerical Investigation of Fluid Flow and Space Charge in Liquid Argon Time Projection Chamber (LArTPC) Detectors

Overview This project focused on developing a high-fidelity numerical framework to simulate the multiphysics environment within Liquid Argon Time Projection Chamber (LArTPC) detectors. The primary objective was to characterize the complex interplay between ion transport, background fluid dynamics, and electric field distortions—a critical factor for the calibration and sensitivity of next-generation High Energy Physics experiments, such as DUNE. Technical Achievements The research successfully yielded a hybrid numerical space-charge solver utilizing a Cell-Centered Finite Volume Method (FVM) for ion transport coupled with a Finite Element Method (FEM) for electric potential. Key accomplishments include: • Verification & Validation: The 3-D solver was rigorously verified against 1-D analytical solutions, demonstrating high numerical accuracy in predicting space-charge-induced field deviations. • Field Distortion Analysis: 3D simulations revealed that space charge effects introduce significant non-uniformities in the electric field. Critically, the research identified that background LAr flow velocities, when comparable to ion drift velocities, markedly exacerbate these distortions. • Technology Transfer: The resulting source code and comprehensive user manuals were successfully transferred to collaborators at Fermilab, providing a portable computational tool for the broader scientific community. Challenges and Future Directions While the space-charge solver achieved all performance metrics, the integrated fluid dynamics modeling encountered convergence challenges stemming from the extreme 200-fold disparity in length scales between the detector's 37 mm inlet pipes and the 8-meter global domain. To address this, the project has identified a clear technical pivot toward Hierarchical Geometric Adaptive Mesh Refinement (HG-AMR). By implementing an h-type refinement strategy with hanging nodes, future iterations of this solver will be capable of resolving localized high-gradient inlet flows without the prohibitive computational costs of regular grids. This advancement, combined with data-driven uncertainty quantification based on MicroBooNE-style calibration, will enable the precise modeling of detector responses in large-scale cryogenic environments where direct measurement remains difficult. Impact The computational tools developed under this award provide a foundation for enhancing the energy resolution and spatial reconstruction of noble liquid detectors. By bridging the gap between theoretical fluid dynamics and experimental field calibration, this work supports the DOE’s mission to advance the frontiers of neutrino physics and dark matter detection.

42 ENGINEERING↗

Extension of Clad Damage Propagation Model for Fission Gas Dispersal and Two-Phase Flow Effects in MOOSE SubChannel Module

This report presents an extension of the Clad Damage Propagation (CDAP) model implemented in the MOOSE SubChannel Module (SCM) to capture post-failure fission-gas dispersal and two-phase flow effects in sodium-cooled fast reactor assemblies. The extended model tracks discharged gas axially and radially, computes channel-averaged flow quality and void fraction using a Lockhart–Martinelli framework, evaluates two-phase frictional pressure-drop multipliers, determines inlet mass-flow degradation under fixed core pressures, and applies an intensified-void-based heat-transfer degradation to affected fuel pins. Radial plume expansion is parameterized using mineral-oil jet experiments mapped to sodium conditions via Reynolds–Weber similarity. Implementation details are documented, along with the new methods and user inputs needed to control plume mapping and two-phase behavior. Demonstration simulations for 19- and 37-pin bundles show that breach size and inlet velocity strongly influence propagation potential: small breaches (≤0.5 mm) produce limited degradation while larger breaches (~1 mm) can drive oscillatory temperature spikes and enhanced failure propagation, especially at higher velocities. These results demonstrate that the extended CDAP model provides a more complete framework for quantifying cladding damage propagation and evaluating propagation potential in transient scenarios. The approach remains computationally efficient, consistent with subchannel-level analysis, yet incorporates sufficient physics to bridge localized post-failure effects with bundle- and assembly-scale degradation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Computational Analysis of Hydraulic Efficiency of Michigan DOT Covers J and K

Drainage structures are used in urban street and highway systems to capture stormwater runoff. These structures typically consist of catch basins fitted with grates, inlets, or combination grate/inlet configurations that collect runoff and convey it through buried drainage systems. They are strategically placed within curb-and-gutter systems to enhance public safety by efficiently removing water from roadways and thereby reducing the risk of hydroplaning. The performance of drainage structures is commonly evaluated in terms of hydraulic efficiency, defined as the percentage of flow captured by the basin relative to the total flow reaching the structure. Understanding the hydraulic performance of these structures allows designers to properly space inlets, resulting in cost-effective designs that also help ensure the safety of the traveling public. MDOT uses a variety of drainage structures for runoff capture, as documented in Michigan Department of Transportation (MDOT) Drainage Manual. Many of these structures incorporate sinusoidal-type grates that are not addressed in HEC-22. Because physical modeling of these structures has been limited, further analysis is needed to verify their capture efficiency. Under current MDOT practice, the capture efficiency of these grates is estimated by assuming performance similar to that of a comparably sized reticuline grate described in HEC22. The first phase of this effort, titled Computational Analysis of Hydraulic Efficiency of Michigan DOT Cover C, focused on evaluating the hydraulic performance of MDOT’s Cover C grate. Cover C was selected as the initial test candidate because its sinusoidal pattern is representative of other MDOT grates, while it is typically used in high-volume, higher-speed applications. A similar version, Cover CX, is used on interstate highways but does not include transverse bars for bicycle safety. The current second phase of the study expands this work to evaluate MDOT’s Covers J and K. These grates were selected for additional analysis to further assess the hydraulic performance of MDOT drainage structures that are not directly represented by grate configurations in HEC-22. The results of this phase will build on the findings from the Cover C analysis and support improved understanding of the capture efficiency of MDOT’s standard drainage grates. This report is intended to serve as a companion document to the earlier study, Computational Analysis of Hydraulic Efficiency of Michigan DOT Cover C [3]. The present work applies the same overall CFD-based evaluation approach to MDOT Covers J and K and compares the resulting performance trends with those previously identified for Cover C. In particular, both studies assess on-grade interception efficiency, sag-location hydraulic capacity, and the effects of partial obstruction relative to HEC-22-based design estimates.

42 ENGINEERING↗

Particle Vertical Mixing and Horizontal Conveyance Within an Ambient Temperature Fluidized Bed

Previous studies have shown the advantages of particle-to-sCO2 fluidized bed (FB) heat exchangers, which include high heat transfer coefficients, low material cost, and the ability to horizontally convey solid particles. This paper outlines the design and testing of a compact cold flow FB test apparatus to characterize horizontal conveyance through convolutions within a 100 kWth FB heat exchanger design. Horizontal conveyance is an advantage in FBs because it enables more compact designs for heat exchangers. Two mass flow rates, 0.5 & 1 kg/s, at the inlet & outlet of the FB. To determine consistency of the flow rates, Student’s t-tests were used to assess whether the inlet & outlet values were statistically similar. The mass flow rate exiting the bed was statistically similar to the flow rate entering the bed for both cases, but each case featured a wider range and standard deviation. The range and standard deviation of the 1 kg/s flow rate was 0.69-1.23 kg/s and 0.12 kg/s respectively, and the 0.5 kg/s test featured a range and standard deviation of 0.37-0.73 kg/s and 0.09 kg/s, respectively. These measurements provide confidence that large-scale designs can successfully horizontally convey particles at ````~1.5x minimum fluidization velocity (U­mf) without significant variation in flow rate. A method to characterize the degree of particle vertical mixing and bubble frequency within the FB is also introduced. By using a high-resolution camera together with particle velocimetry, particle motion in the X and Y directions can be estimated to assess bed mixing and bubble frequency.

Khalaf, Jawad↗

Cloud Condensation Nuclei and Printed Optical Particle Spectrometer Measurements at Mt. Soledad during EPCAPE 2023-24

These measurements are provided by a differential mobility analyzer operated as a scanning mobility particle sizer, a printed particle optical spectrometer (POPS), and a continuous flow diffusion cloud condensation nuclei (CCN) counter. The instruments sample from either a counterflow virtual impactor inlet or an isokinetic inlet. The measurements provide the mobility aerosol size distribution (30-360 nm), optical size distribution (150 - 6000 nm), size-resolved CCN distribution (30-360 nm) at 0.2, 0.4, 0.6, 0.8, and 1.0% supersaturation. CCN measurements are performed in denuded and undenuded configuration, where denuded refers to the removal of low molecular weight organic vapors. A detailed NetCDF header is included with the datafiles. Users of these measurements are encouraged to consult with the authors about appropriate interpretation before submitting for publication, offering coauthorship where appropriate.

54 ENVIRONMENTAL SCIENCES↗

Volatile Organic Compounds in Bankhead National Forest (AMF3). August to September, 2025

The formation of atmospheric aerosols through the transformation of volatile organic compounds (VOCs) is a fundamental process in aerosol-climate interactions, as these particles serve as cloud condensation nuclei and ultimately influence Earth’s radiative balance. However, there remains a critical need to quantify the effects of multiple coexisting VOC precursors on aerosol formation beyond the limitations of laboratory-scale studies. This research aims to advance the mechanistic understanding of secondary organic aerosol formation in the southeastern United States by investigating interactions among coexisting VOC precursors observed at the third ARM Mobile Facility located in the Bankhead National Forest. The dataset was generated from the deployment of Oak Ridge National Laboratory’s PTR-TOF 6000 X2 Proton Transfer Reaction Time-of-Flight Mass Spectrometer (PTR-ToF-MS) for the real-time, continuous monitoring of VOCs from August 21 to September 15, 2025. To minimize sampling artifacts and compound losses, the PTR-ToF-MS inlet was connected to the cabin flow line by replacing the existing Tygon tubing with 1/2-inch outer diameter perfluoroalkoxy (PFA) tubing. The instrument operated on an hourly measurement cycle consisting of 8 minutes of zero-air measurements followed by 52 minutes of ambient air sampling, with a temporal resolution of 10 seconds. The dataset includes concentrations, reported in ppb, of methanol, acetone, acetonitrile, isoprene, methyl vinyl ketone and methacrolein (MVK + MACR), monoterpenes, benzene, toluene, and catechol.

Atmospheric concentration of volatile organic comp↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - Simulated Marine Hydrokinetic Tidal Turbine

The U.S. Department of Energy and National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis, hydrogen compression and storage, and variable hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset is part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with other energy technologies. This dataset contains inputs and outputs from simulations of a floating marine hydrokinetic turbine over approximately half a tidal cycle (~6.6 hours). Inflow conditions were derived from field measurements in Alaska’s Cook Inlet and represent a tidal environment in which the current speed ramps from near 0 m/s to a peak of 3 m/s and back. The original acoustic doppler current profiler dataset is publicly available on the Marine and Hydrokinetic Data Repository. In a full tidal cycle, the flow reverses and the rotor would reorient; this reversal was not modeled. In the Cook Inlet campaign , turbulence intensity was similar in both directions. Two inflow cases are included. In the first case, labeled “raw” in the files, the measured current time series was used directly in the InflowWind module of OpenFAST. Speed and direction were applied as a function of time and elevation, uniformly in the horizontal direction. With full spatial coherence, this approach captures high turbulent variability and results in pronounced power fluctuations, so it is considered a conservative, near-worst-case representation of loading. In the second case, labeled “average” in the files, a 30-minute moving average was applied to extract the slowly varying mean speed. The residual fluctuations about this mean were used to generate spatially varying, full-field turbulence inputs with TurbSim, giving a more physically realistic representation of the inflow across the rotor disk. Two random realizations were used to produce distinct inflow conditions for two OpenFAST simulations representing a two-turbine array. The same turbulence intensity is applied across the full time series, producing larger fluctuations at the start and end, where the mean speed is low. The second case is the more appropriate framework for performance and power assessment but overpredicts turbulence at lower flow speeds and underpredicts it at higher speeds. As the floating platform moves and the rotor changes its x-position, Taylor’s frozen turbulence hypothesis used by InflowWind assumes a constant rather than a time-varying mean velocity, introducing some inaccuracy in the velocity plane sampling. The turbine modeled is the 500-kW Reference Model 1, a horizontal-axis two-bladed hydrokinetic turbine on a four-column floating semisubmersible substructure . Simulations were performed using OpenFAST v4.1 with the Reference Open Source Controller (ROSCO) v2.10. All input files required to reproduce the simulations are included. The electrolyzer is a 1.25-MW proton exchange membrane type MC250 system manufactured by Nel . This unit supports up to 2.5 MW, but NLR has only a single 1.25-MW stack. The datasets report hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. The system controls hydrogen production by varying direct current applied to the stack, from a maximum of 3,000 A to a minimum safe operating current of 300 A, or 10%. Because the current–voltage characteristic changes as the stack ages and efficiency degrades, the actual minimum safe operating power changes over time. The simulated tidal turbine time series data was translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz. Each zip file represents a single tidal electrolysis experiment and is named: {technology}_{inflow method}_{number of 500 kW tidal turbines connected} For instance, “tidal-500kW-RM1_average_2.zip” is a 6-hour experiment using the 500-kW tidal reference model, scaled by 2x (1-MW) to better match the electrolyzer maximum of 1.25MW, fed with the 30-minute moving average current case. Each zip folder contains the following files: A .csv file of raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production in kilograms per hour, electrolysis power consumption, and input wave power. A .csv file combines all tidal profiles as "combined_tidal_experiments.csv." A separate experiment, “characterization_200.zip,” shows the MC250 electrolyzer steady-state response with 30-minute load steps over 5 hours and is accessible with this entry.

08 HYDROGEN↗