Search NASA⌕ Search

SEARCH · Search NASA

Results for “interlaboratory study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

69 records · Page 4

Testing nuclear data libraries with burnup for reactor applications

Recently US and European nuclear data libraries have been released, namely ENDF/B-VIII.0 and JEFF-3.3 libraries, which are the result of years of evaluation and validation work in both communities. Consequently, efforts have been made to validate the evaluations in calculations of integral experiments (critical benchmarks, ..etc). Nevertheless, less stringent testing and validation efforts were performed on burnup applications before releasing the libraries. The presented work focusses on the testing of these recent nuclear data libraries for burnup calculations on two benchmarks at the pin and at the assembly level. Monte-Carlo depletion calculations were performed using the VESTA 2.2 code. The K{sub ∞} results between nuclear data libraries are compared. A strong k{sub ∞} bias is observed with burnup using both JEFF-3.3 and JEFF-4T0 compared to all other libraries, and especially ENDF/B-VIII.0, consisting in a strong k{sub ∞} over-estimation at low burnup and a high under-estimation at high burnup. JEFF-3.3 {sup 235}U and {sup 239}Pu evaluations mainly explain this result, as well as fission yields. New {sup 235}U and {sup 239}Pu evaluations were proposed for JEFF-4T0, but they do not address totally the bias issue, even if JEFF-4T0 {sup 239}Pu allows slightly reducing the k{sub ∞} underestimation at high burnup.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Interlaboratory Reproducibility of Contour Method Data in a High Strength Aluminum Alloy

The contour method for residual stress measurement has seen significant development, but an experimental reproducibility study utilizing physical samples has not been published. A double-blind reproducibly study is reported, having scope beginning with EDM cutting and ending with residual stress calculation. A reinforced I-beam sample geometry is identified for its unique residual stress profile when extracted from residual stress bearing quenched aluminum bar (7050-T74). Contour measurements are prescribed on a midplane of symmetry with dimensions 24.0 mm by 50.0 mm. Fourteen identically prepared samples are fabricated from a single long bar with well characterized and uniform residual stress. Five samples throughout the bar are identified for planning measurements to validate sample uniformity and overall suitability of the residual stress field. The planning measurements employ a range of techniques: contour method, neutron diffraction, and hole-drilling. Eight samples are distributed to an international group of participants to execute their standard measurement practice. A double-blind process is followed to provide anonymity. Results are provided by eight participants: six being self-similar and two being quite different, the latter set aside as outliers. An average residual stress field is established from non-outlying results and the spatial distribution of reproducibility standard deviation is determined. The average stress field ranges from -60 to 70 MPa and the reproducibility standard deviation averages 8.1 MPa on the measurement plane. The average reproducibility standard deviation is about 3 × larger for points within 1.0 mm of plane boundaries (17.6 MPa) than for the remaining points (6.1 MPa). Reproducibility standard deviation (among different labs) for contour method residual stress measurement is found to be very similar to repeatability standard deviation (in a single lab) reported in prior work. The reproducibility observed here, for the entire measurement process, is also similar to that found in a prior reproducibility study limited to contour method data analysis.

36 MATERIALS SCIENCE↗

Degradation in PV Encapsulant Transmittance: Results of the First PVQAT TG5 Study

Reduced optical transmittance of encapsulants resulting from ultraviolet (UV) degradation has frequently been identified as a cause of decreased PV module performance through the life of service in the field. The present module safety and qualification standards, however, apply short UV doses only capable of examining design robustness or 'infant mortality' failures. The latest versions of the safety and qualification apply ~40 - ~160 days cumulative dose of the AM1.5G total UV radiation. Essential information that might be used to screen encapsulation through product lifetime also remains unknown. For example, the relative efficacy of xenon-arc and UVA-340 fluorescent sources or the typical range of activation energy for degradation is not quantified. We have conducted an interlaboratory experiment to provide the understanding that will be used towards developing a higher fidelity, more rigorous UV weathering test. Five representative, known formulations of EVA were studied in addition to one TPU material. Replicate laminated silica/polymer/silica specimens were examined at 10 institutions using a variety of indoor chambers (including Xenon, UVA-340, and high pressure mercury light sources). Specimens were artificially weathered for 180 cumulative days at pre-designated accelerated test conditions. The solar-weighted transmittance, yellowness index, and the UV cut-off wavelength, determined from the measured hemispherical transmittance, are examined to provide understanding and guidance for the UV light source (lamp type) and temperature used in accelerated UV aging tests.

14 SOLAR ENERGY↗

International interlaboratory compilation of trace element concentrations in the CUP-2 uranium ore concentrate standard

Herein, a nuclear forensics investigation involving a uranium ore concentrate relies on accurate and precise analysis of impurities. Analytical data defensibility requires the use of reference materials as part of quality control. This study presents a compilation of trace element concentration results of the CUP-2 Uranium Ore Concentrate Standard measured by 11 different laboratories. The laboratories employed various dissolution methods, analytical preparation methods, and instrumental platforms. The data presented here contain concentrations of 66 impurities with up to 138 individual data points for each impurity. Consensus values have been assigned to each impurity following a statistical analysis of the data set.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Additive manufacturing of platinum group element (PGE) reference materials with a silica matrix

The microanalytical community has an outstanding need for platinum group element (PGE) reference materials, particularly for trace element analysis by laser ablation inductively coupled plasma mass spectrometry (LA-ICPMS). National Institute of Standards and Technology (NIST) glasses contain Rh, Pd, and Pt, but lack Ru, Os, and Ir. Synthesis of silicate PGE standards has proven difficult due the tendency of PGEs to form metallic nuggets. Additive manufacturing methods were used to produce PGE standards with a silica matrix. Monodispersed submicron PGE-doped Stöber particles were used as feedstock materials for electrophoretic deposition (EPD). Two-cm-sized samples produced by EPD were subsequently densified by thermal processing. The homogeneity of PGEs was tested using LA-ICPMS and concentrations were measured by laser ablation and solution ICPMS. The PGE concentrations ranged from 0.5 to 3 μg/g. The inhomogeneity was at the 3% RSD level for Ru, Rh, Ir, and Os throughout and 5% for Pt and Pd in the interior of the samples. Based on LA-ICPMS analyses, the interiors of the two samples have near identical concentrations in PGEs. The samples fabricated in this study represent the most complete and homogeneous PGE standards produced with a silicate matrix. The ability to produce multiple samples with the same composition provides opportunities for validating methods, monitoring long-term reproducibility, and facilitating interlaboratory comparisons.

36 MATERIALS SCIENCE↗

FINAL TECHNICAL REPORT

NIST has played a key role in many of the one-on-one, domestic, and international interlaboratory comparisons of measurements on superconductors. The history of interlaboratory comparisons of measurements on superconductors tells us that careful measurement methods are needed to obtain consistent results. Inconsistent results can lead to many problems including: a mistrust of the results of others, unfair advantages in commerce, and erroneous feedback in the optimization of conductor performance. NIST has experience in many interlaboratory comparisons; a long-term commitment to measurement accuracy; and independent, third-party laboratory status. The principal investigator's direct involvement in the measurements and daily supervision of sample mounting is the unique situation that has allowed important discoveries and evolution of our capabilities over the last 30 years. The principal investigator's research and metrology has helped to improve the accuracy of critical-current (I{sub c}) measurements in laboratories throughout the world. As conductors continue to improve and design limits are tested, the continuation of the long-term commitment to measurement accuracy could be vitally important to the success of new conductor development programs. It is extremely important to the U.S. wire manufacturers to get accurate (high certainty) I{sub c} measurements in order to optimize conductor performance. The optimization requires the adjustment of several fabrication parameters (such as reaction time, reaction temperature, conductor design, doping, diffusion barrier, Cu to non-Cu ratio, and twist pitch) based on the I{sub c} measurement of the conductor. If the I{sub c} measurements are made with high variability, it may be unclear whether or not the parameters are being adjusted in the optimal direction or whether or not the conductor meets the target specification. Our metrology is vital to the U.S. wire manufacturers in the highly competitive international arena and to meet the aggressive performance goals. The latest high-performance Nb{sub 3}Sn wires are being designed with higher current densities, larger effective filament diameter, less Cu stabilizer, and, in some cases, larger wire diameters than ever before. In addition, some of the conductor designs and heat treatments cause the residual resistivity ratio (RRR, ratio of room temperature resistivity to the resistivity at 20 K) of the stabilizer to be less than 20. These parameters are pushing the conductors towards less intrinsic stability, into a region we call marginally stable. These parameters also create a whole series of challenges for routine I{sub c} testing on short-samples, even when tested with the sample immersed in liquid helium. High-current, variable-temperature I{sub c} measurements are even more difficult than those made in liquid helium because the sample is only cooled by flowing helium gas. Providing accurate I{sub c} results under these conditions requires a complex system that provide adequate cooling as well as uniform sample temperature. We have been make variable-temperature measurements for about 15 years, but we started to design the first high-current (at least 500 A), variable-temperature, variable-strain apparatus in late 2006. Our first critical-current measurements as a function of strain, temperature, and magnetic field, I{sub c}(B,T,{var_epsilon}), in a new single, unified apparatus (full matrix characterization) were made in the summer of 2008. This is the only such facility in the U.S. and it has some unique components that are not duplicated anywhere in the world. The compounding of all three variables (H, T, {var_epsilon}) makes an already labor and time intensive characterization very formidable; however, the results cannot be generated any other way and are needed to answer key questions about strain and temperature safety margins and about the reliability of using scaling laws based on small data sets to predict performance. In the future, this new apparatus will allow NIST to create a database on strands that would benefit U.S. superconductor wire manufacturers, national research laboratories, and programs using superconductor strands such as HEP and International Thermonuclear Experimental Reactor (ITER).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Radiochronometric discordance in cast uranium metal: a multi-laboratory intercomparison exercise

Here, the model age of a nuclear material is crucial in nuclear forensic analysis. Uranium metals with complex production histories often exhibit discordant model ages from the 230 Th– 234 U and 231 Pa– 235 U chronometers. Recent studies involving targeted uranium metal castings have enhanced our understanding of decay product behavior during casting, aiding nuclear forensic interpretation. Building on this prior work, forensics laboratories at Atomic Weapons Establishment (AWE), Lawrence Livermore National Laboratory (LLNL), and Los Alamos National Laboratory (LANL) conducted an interlaboratory comparison to investigate spatial heterogeneity in uranium metal cast under controlled conditions. Each laboratory measured samples of a mixed feedstock and its corresponding cast product. This work furthers our understanding of discordant model ages and the use of discordance as a signature to enhance confidence in interpretations of radiochronometric data for nuclear forensics.

230Th/234U↗

An interlaboratory comparison of mid-infrared spectra acquisition: Instruments and procedures matter

Diffuse reflectance spectroscopy has been extensively employed to deliver timely and cost-effective predictions of a number of soil properties. However, although several soil spectral laboratories have been established worldwide, the distinct characteristics of instruments and operations still hamper further integration and interoperability across mid-infrared (MIR) soil spectral libraries. In this study, we conducted a large-scale ring trial experiment to understand the lab-to-lab variability of multiple MIR instruments. By developing a systematic evaluation of different mathematical treatments with modeling algorithms, including regular preprocessing and spectral standardization, we quantified and evaluated instruments' dissimilarity and how this impacts internal and shared model performance. We found that all instruments delivered good predictions when calibrated internally using the same instruments' characteristics and standard operating procedures by solely relying on regular spectral preprocessing that accounts for light scattering and multiplicative/additive effects, e.g., using standard normal variate (SNV). When performing model transfer from a large public library (the USDA NSSCKSSL MIR library) to secondary instruments, good performance was also achieved by regular preprocessing (e. g., SNV) if both instruments shared the same manufacturer. However, significant differences between the KSSL MIR library and contrasting ring trial instruments responses were evident and confirmed by a semi-unsupervised spectral clustering. For heavily contrasting setups, spectral standardization was necessary before transferring prediction models. Non-linear model types like Cubist and memory-based learning delivered more precise estimates because they seemed to be less sensitive to spectral variations than global partial least square regression. In summary, the results from this study can assist new laboratories in building spectroscopy capacity utilizing existing MIR spectral libraries and support the recent global efforts to make soil spectroscopy universally accessible with centralized or shared operating procedures.

58 GEOSCIENCES↗

SERPENT 2 and TRIPOLI-4 neutronics benchmarking of the Jules Horowitz reactor

Jules Horowitz Reactor (JHR) is a future center for nuclear material testing in Europe, currently under construction at CEA Cadarache in southern France. It has been modelled extensively with CEA's HORUS3D/N neutron calculation package, that includes a Monte-Carlo neutron transport code TRIPOLI-4. In order to support the future computational analyses on the reactor core physics, VTT's Monte Carlo neutronics code SERPENT 2 has been used to create an alternative model of the JHR, taking advantage of the pre-existing Constructive Solid Geometry (CSG) structures on which the TRIPOLI-4 model was built. This work describes a benchmark, in which two JHR core configurations were analyzed using both of these models. The first configuration is a fresh fuel core at the beginning of life, in which aluminum based dummy-devices are installed in the reactor test positions. The second configuration represents the end-of-cycle equilibrium core with a heterogeneous burnup distribution, in which CALIPSO devices containing cladding material samples are installed at the in-core experimental positions, while the reflector positions are occupied by DEN-REP devices containing UO{sub 2} fuel. Neutron flux spectra and heat deposition are the parameters of interest in this study, due to their high importance in creating the desired experimental irradiation environment. The impact of delayed gamma energy deposition will be studied in detail, since the two models account for it with different methods. This work aims to establish a SERPENT 2 model of JHR, understanding its differences and agreements with TRIPOLI-4, and discussing its potential future applications. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Uncertainty Analysis of Consequence Management Data Products

An interlaboratory effort has developed a probabilistic framework to characterize uncertainty in data products that are developed by the US Department of Energy Consequence Management Program in support of the Federal Radiological Monitoring and Assessment Center. The purpose of this paper is to provide an overview of the probability distributions of input variables and the statistical methods used to propagate and quantify the overall uncertainty of the derived response levels that are used as contours on data products due to the uncertainty in input parameters. Uncertainty analysis results are also presented for several study scenarios. This paper includes an example data product to illustrate the potential real-world implications of incorporating uncertainty analysis results into data products that inform protective action decisions. Data product contours that indicate areas where public protection actions may be warranted can be customized to an acceptable level of uncertainty. Finally, the investigators seek feedback from decision makers and the radiological emergency response community to determine how uncertainty information can be used to support the protective action decision-making process and how it can be presented on data products.

61 RADIATION PROTECTION AND DOSIMETRY↗

Rapid and automated separation of uranium ore concentrates for trace element analysis by inductively coupled plasma – optical emission spectroscopy/triple quadrupole mass spectrometry

The present study documents an automated approach to performing elemental analysis on a large group uranium ore concentrate (UOC) samples. In this work, 17 UOC samples, 2 quality control samples, and 26 process blanks were purified sequentially through a single 500 μL Uranium and TEtra Valent Actinides (UTEVA®) column. For each sample, the trace elemental impurities were separated from its dissolved uranium matrix on the UTEVA column and collected for analysis by inductively coupled plasma – optical emission spectroscopy / triple quadrupole mass spectrometry (ICP-OES/TQMS). The UTEVA column was subsequently regenerated prior to separation of the following sample. The column was efficiently regenerated, for each UOC, even after processing ~50 mg of uranium, cumulatively. The validity of the method was established by determining the trace impurities of two quality control uranium reference samples (CRM 124–1 and CUP-2). The current trace element measurements from the 17 UOC samples were compared to previously reported values from an interlaboratory comparison exercise, when available. The methodology employed here produces trace elemental analysis with excellent correlation to the previously reported data for many of the elements / samples, particularly when viewed through the context of existing geochemical comparisons tools (e.g. chondrite normalized variation plots).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

T24 HRAS transformed NIH/3T3 mouse cells (GhrasT-NIH/3T3) in serial tumorigenic in vitro/in vivo passages give rise to increasingly aggressive tumorigenic cell lines T1-A and T2-A and metastatic cell lines T3-HA and T4-PA

Cancer cells often arise progressively from “normal” to “pre-cancer” to “transformed” to “local metastasis” to “metastatic disease” to “aggressive metastatic disease”. Recent whole genome sequencing (WGS) and spectral karyotyping (SKY) of cancer cells and tumorigenic models have shown this progression involves three major types of genome rearrangements: ordered small step-wise changes, more dramatic “punctuated evolution” (chromoplexy), and large catastrophic steps (chromothripsis) which all occur in random combinations to generate near infinite numbers of stochastically rearranged metastatic cancer cell genomes. This paper describes a series of mouse cell lines developed sequentially to mimic this type of progression. This starts with the new GhrasT-NIH/Swiss cell line that was produced from the NIH/3T3 cell line that had been transformed by transfection with HRAS oncogene DNA from the T24 human bladder carcinoma. These GhrasT-NIH/Swiss cells were injected s.c. into NIH/Swiss mice to produce primary tumors from which one was used to establish the T1-A cell line. T1-A cells injected i.v. into the tail vein of a NIH/Swiss mouse produced a local metastatic tumor near the base of the tail from which the T2-A cell line was established. T2-A cells injected i.v. into the tail vein of a nude NIH/Swiss mouse produced metastases in the liver and one lung from which the T3-HA (H=hepatic) and T3-PA (P=pulmonary) cell lines were developed, respectively. T3-HA cells injected i.v. into a nude mouse produced a metastasis in the lung from which the T4-PA cell line was established. PCR analysis indicated the human T24 HRAS oncogene was carried along with each in vitro/in vivo transfer step and found in the T2-A and T4-PA cell lines. Light photomicrographs indicate that all transformed cells are morphologically similar. GhrasT-NIH/Swiss cells injected s.c. produced tumors in 4% of NIH/Swiss mice in 6–10 weeks; T1-A cells injected s.c. produced tumors in 100% of NIH/Swiss mice in 7–10 days. T1-A, T-2A, T3-HA and T4-PA cells when injected i.v. into the tail produced local metastasis in non-nude or nude NIH/Swiss mice. T4-PA cells were more widely metastatic than T3-HA cells when injected i.v. into nude mice. Evaluation of the injected mice indicated a general increase in metastatic potential of each cell line in the progression as compared to the GhrasT-NIH/3T3 transformed cells. A new photomicrographic technique to follow growth rates within six preselected 2×2 mm{sup 2} grids per plate is described. Average doubling times of the transformed cells GhrasT-NIH/3T3 (17 h), T1A (17.5 h), T2A (15.5 h), T3-HA (17.5 h) and T4-PA (18.5 h) (average 17.2 h) were significantly faster (P=0.006) than NIH Swiss primary embryonic cells and NIH/3T3 cells (22 h each). This cell series is currently used in this lab for studies of cancer cell inhibitors, mitochondrial biogenesis and gene expression and is available for further study by other investigators for intra- and inter-laboratory comparisons of WGS, transcriptome sequencing, SKY and other analyses. The genome rearrangements in these cells together with their phenotypic properties may help provide more insights into how one tumorigenic progression occurred to produce the various cell lines that led to the highly metastatic T4-PA cell line. - Highlights: • A tumor progression model derived from a new T24 HRAS transformed NIH/3T3 cell line. • T1-A, T2-A, T3-HA, T4PA lines derived from GhrasT-NIH/3T3, T1-A, T2-A, T3-HA tumors. • PCR detected the human HRAS oncogene in T2-A and T4-PA metastatic tumors. • These five new cell lines showed a progressive increase in tumorigenic potential. • New method obtained doubling times using daily photomicrographs of gridded plates.

60 APPLIED LIFE SCIENCES↗

Interlaboratory Evaluation of in Vitro Cytotoxicity and Inflammatory Responses to Engineered Nanomaterials: The NIEHS Nano GO Consortium

Background: Differences in interlaboratory research protocols contribute to the conflicting data in the literature regarding engineered nanomaterial (ENM) bioactivity. Objectives: Grantees of a National Institute of Health Sciences (NIEHS)-funded consortium program performed two phases of in vitro testing with selected ENMs in an effort to identify and minimize sources of variability. Methods: Consortium program participants (CPPs) conducted ENM bioactivity evaluations on zinc oxide (ZnO), three forms of titanium dioxide (TiO2), and three forms of multiwalled carbon nanotubes (MWCNTs). In addition, CPPs performed bioassays using three mammalian cell lines (BEAS-2B, RLE-6TN, and THP-1) selected in order to cover two different species (rat and human), two different lung epithelial cells (alveolar type II and bronchial epithelial cells), and two different cell types (epithelial cells and macrophages). CPPs also measured cytotoxicity in all cell types while measuring inflammasome activation [interleukin-1β (IL-1β) release] using only THP-1 cells. Results: The overall in vitro toxicity profiles of ENM were as follows: ZnO was cytotoxic to all cell types at ≥ 50 μ g/mL, but did not induce IL-1β. TiO2 was not cytotoxic except for the nanobelt form, which was cytotoxic and induced significant IL-1β production in THP-1 cells. MWCNTs did not produce cytotoxicity, but stimulated lower levels of IL-1β production in THP-1 cells, with the original MWCNT producing the most IL-1β. Conclusions: The results provide justification for the inclusion of mechanism-linked bioactivity assays along with traditional cytotoxicity assays for in vitro screening. In addition, the results suggest that conducting studies with multiple relevant cell types to avoid false-negative outcomes is critical for accurate evaluation of ENM bioactivity.

cell viability↗

Gross Alpha Beta Radioactivity in Air Filters Measured by Ultra Low Level alpha/beta Counter

Study of radioactivity in air as very important for life is done regularly using different methods in every country. As a result of nuclear reactors, atomic centrals, institutions and laboratories, which use the radioactivity substances in open or closed sources, there are a lot radioactive wastes. Mixing of these wastes after treatment with rivers and lakes waters makes very important control of radioactivity. At the other side nuclear and radiological accidents are another source of the contamination of air and water. Due to their radio toxicity, especially those of Sr{sup 90}, Pu{sup 239}, etc. a contamination hazard for human begins exist even at low concentration levels. Measurements of radioactivity in air have been performed in many parts of the world mostly for assessment of the doses and risk resulting from consuming air. In this study we present the results of international comparison organized by IAEA Vienna, Austria for the air filters spiked with unknown Alpha and Beta Activity. For the calibration of system we used the same filters spiked: a) with Pu-239 as alpha source; b) Sr-90 as beta source and also the blank filter. The measurements of air filter samples after calibration of the system are done with Ultra Low Level alpha/beta Counter (MPC 9604) Protean Instrument Corporation. The high sensitivity of the system for the determination of the Gross Alpha and Beta activity makes sure detection of low values activity of air filters. Our laboratory results are: Aalpha = (0.19+-0.01) Bq/filter and Aalpha(IAEA) = (0.17+-0.009) Bq/filter; A{sub b}eta = (0.33+-0.009) Bq/filter and A{sub b}eta (IAEA) = (0.29+-0.01) Bq/filter. As it seems our results are in good agreement with reference values given by IAEA (International Atomic Energy Agency).

54 ENVIRONMENTAL SCIENCES↗