Search NASA⌕ Search

SEARCH · Search NASA

Results for “iterative analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

ITER LIDAR performance analysis

The core LIDAR Thomson scattering for ITER is specified for core profile measurements with a spatial resolution of 7 cm (a/30) for the range of 500 eV<T{sub e}<40 keV and n{sub e}>3x10{sup 19} m{sup -3} at an accuracy of <10% for T{sub e}. These specifications are verified using a full profile Monte Carlo simulation code. In the simulations it is assumed that the input transmission is 50% and the collection transmission is 10% for {lambda}=300-1200 nm and F/=6-17. A crucial design decision lies on the choice of laser and detector combination. It is evaluated that the system can meet its spatial and accuracy specifications for higher temperatures of T{sub e}>5 keV with a combination of a neodymium-doped yttrium aluminum garnet (Nd:YAG) laser ({lambda}{sub 0}=1064 nm, {delta}{lambda}<1 nm, 5 J, and {delta}t{sub FWHM}=250 ps, 5-10 Hz) and S20, GaAs, and GaAsP microchannel plate photomultipliers ({delta}t{sub FWHM}<300 ps, effective quantum efficiency, EQE=3%-4%, and D=18 mm). In order to reach the required T{sub e} of 500 eV with Nd:YAG first harmonic, this choice requires a development of fast near infrared detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TH-E-9A-01: Medical Physics 1.0 to 2.0, Session 4: Computed Tomography, Ultrasound and Nuclear Medicine

Medical Physics 2.0 is a bold vision for an existential transition of clinical imaging physics in face of the new realities of value-based and evidencebased medicine, comparative effectiveness, and meaningful use. It speaks to how clinical imaging physics can expand beyond traditional insular models of inspection and acceptance testing, oriented toward compliance, towards team-based models of operational engagement, prospective definition and assurance of effective use, and retrospective evaluation of clinical performance. Organized into four sessions of the AAPM, this particular session focuses on three specific modalities as outlined below. CT 2.0: CT has been undergoing a dramatic transition in the last few decades. While the changes in the technology merits discussions of their own, an important question is how clinical medical physicists are expected to effectively engage with the new realities of CT technology and practice. Consistent with the upcoming paradigm of Medical Physics 2.0, this CT presentation aims to provide definitions and demonstration of the components of the new clinical medical physics practice pertaining CT. The topics covered include physics metrics and analytics that aim to provide higher order clinicallyrelevant quantification of system performance as pertains to new (and not so new) technologies. That will include the new radiation and dose metrics (SSDE, organ dose, risk indices), image quality metrology (MTF/NPS/d’), task-based phantoms, and the effect of patient size. That will follow with a discussion of the testing implication of new CT hardware (detectors, tubes), acquisition methods (innovative helical geometries, AEC, wide beam CT, dual energy, inverse geometry, application specialties), and image processing and analysis (iterative reconstructions, quantitative CT, advanced renditions). The presentation will conclude with a discussion of clinical and operational aspects of Medical Physics 2.0 including training and communication, use optimization (dose and technique factors), automated analysis and data management (automated QC methods, protocol tracking, dose monitoring, issue tracking), and meaningful QC considerations. US 2.0: Ultrasound imaging is evolving at a rapid pace, adding new imaging functions and modes that continue to enhance its clinical utility and benefits to patients. The ultrasound talk will look ahead 10–15 years and consider how medical physicists can bring maximal value to the clinical ultrasound practices of the future. The roles of physics in accreditation and regulatory compliance, image quality and exam optimization, clinical innovation, and education of staff and trainees will all be considered. A detailed examination of expected technology evolution and impact on image quality metrics will be presented. Clinical implementation of comprehensive physics services will also be discussed. Nuclear Medicine 2.0: Although the basic science of nuclear imaging has remained relatively unchanged since its inception, advances in instrumentation continue to advance the field into new territories. With a great number of these advances occurring over the past decade, the role and testing strategies of clinical nuclear medicine physicists must evolve in parallel. The Nuclear Medicine 2.0 presentation is designed to highlight some of the recent advances from a clinical medical physicist perspective and provide ideas and motivation for designing better evaluation strategies. Topics include improvement of traditional physics metrics and analytics, testing implications of hybrid imaging and advanced detector technologies, and strategies for effective implementation into the clinic. Learning Objectives: Become familiar with new physics metrics and analytics in nuclear medicine, CT, and ultrasound. To become familiar with the major new developments of clinical physics support. To understand the physics testing implications of new technologies, hardware, software, and applications. Identify approaches for implementing comprehensive medical physics services in future imaging practices.

60 APPLIED LIFE SCIENCES↗

Coherent diffraction imaging in the undergraduate laboratory

We present an undergraduate optics instructional laboratory designed to teach skills relevant to a broad range of modern scientific and technical careers. In this laboratory project, students image a custom aperture using coherent diffraction imaging, while learning principles and skills related to digital image processing and computational imaging, including multidimensional Fourier analysis, iterative phase retrieval, noise reduction, finite dynamic range, and sampling considerations. After briefly reviewing these imaging principles, we describe the required experimental materials and setup for this project. Our experimental apparatus is both inexpensive and portable, and a software application we developed for interactive data analysis is freely available.

Porter, J. Nicholas↗

A Knowledge Graph Approach for the Secondary Use of Cancer Registry Data

Population-based central cancer registries collect valuable structured and unstructured data primarily for cancer surveillance and research, enhancing insights into clinical features associated with cancer occurrence, cancer treatment, and cancer outcomes to guide interventions which reduce the cancer burden. Cancer registries primarily collect data on (1) cancer type (case or tumor); (2) patient demographics such as age, gender, and residential address at time of diagnosis; (3) planned first course of treatment; and (4) date of last contact, vital status, and cause of death. Cancer registry data is dynamic, structured data, which is extracted from many unstructured sources such as electronic healthcare records, and consolidated for reporting and other purposes. While available advanced analytic tools such as SEER*Stat have the ability to build SAS queries, we, however, explore an innovative knowledge graph approach to organizing cancer registry data for advanced analytics and visualization, which has unique advantages over approaches of existing tools. This innovative knowledge graph approach semantically enriches the data and easily enables linkage with third-party data, which can better explain variation in outcomes. We have developed a prototype knowledge graph based on data from the Louisiana Tumor Registry and other publicly available datasets including Behavioral Risk Factor Surveillance System, Clinical Trials, DBpedia, GeoNames, Rural-Urban Continuum Codes, and Semantic MEDLINE. The resource description framework (RDF) data model was selected to represent our knowledge graph, which contains more than 25 billion triples and is ~4TB in storage size. To exhibit the benefits of the knowledge graph approach, we used scenario specific queries, which find the relationships between cancer treatment sequences and outcomes. To illustrate its ease of use in iterative analysis, the knowledge graph was linked to external datasets for performing complex queries across multiple datasets. In addition, we used knowledge graphs to identify data discrepancies and to handle schema changes. Finally, we visualized the knowledge graph to discover data patterns. Our results demonstrate this graph-based solution enables cancer researchers to execute complex queries and more easily perform iterative analyses to improve understanding of cancer registry data. In the future, we would like to use high-performance computing (HPC) resources for faster-generating hypotheses with clinical potential from our knowledge graph.

Hasan, S M Shamimul↗

Radiograph and passive data analysis using mixed variable optimization

Disclosed herein are representative embodiments of methods, apparatus, and systems for performing radiography analysis. For example, certain embodiments perform radiographic analysis using mixed variable computation techniques. One exemplary system comprises a radiation source, a two-dimensional detector for detecting radiation transmitted through a object between the radiation source and detector, and a computer. In this embodiment, the computer is configured to input the radiographic image data from the two-dimensional detector and to determine one or more materials that form the object by using an iterative analysis technique that selects the one or more materials from hierarchically arranged solution spaces of discrete material possibilities and selects the layer interfaces from the optimization of the continuous interface data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantifying Optical Loss of High-Voltage Degradation Modes in PV Modules Using Spectral Analysis [Slides]

The direct current bias for photovoltaic (PV) modules interconnected in series-strings may include both high voltage negative ("HV-") and positive ("HV+") polarity with respect to the electrical ground. Multiple degradation modes, resulting in quantifiable optical loss, were found to occur during HV-/HV+ sequential stress, including: corrosion of the external glass surface, encapsulant delamination (at its interfaces with the glass and the PV cell), internal haze formation (resulting from a chemical interaction between the glass and the encapsulant), corrosion and migration of the gridlines, and corrosion of the silicon nitride (SixNy) antireflective coating on the cell. The effects of these separate modes were examined using monolithic (e.g., glass or PV cell) and laminated-coupon (glass/encapsulant/glass or glass/encapsulant/cell/encapsulant/backsheet) specimens. Characterizations during and after unbiased accelerated testing at 85 degrees C/85% relative humidity included: spectrophotometry, optical microscopy, electron microscopy, and ellipsometry. For some module components (i.e., the glass and the SixNy coating), the optical performance was determined through iterative analysis of empirical measurements. Concentrating on just their spectral effect, a novel model was then developed to estimate the transfer of light to the PV cell and the return of light from the PV module with simultaneous degradation mechanisms, which was compared to a mini-module previously subjected to HV-/HV+ stress. The model suggests one-third of the current loss observed for the mini-module can be attributed to the optical degradation of the packaging materials. The dominant degradation modes include encapsulant delamination and corrosion of the SixNy coating. Recommendations are given so that the optical model may be improved relative to accelerated testing and validated relative to field aging.

14 SOLAR ENERGY↗

Quantifying optical loss of high-voltage degradation modes in photovoltaic modules using spectral analysis

The direct current bias for photovoltaic (PV) modules interconnected in series-strings may include both high voltage negative (“HV-”) and positive (“HV+”) polarity with respect to the electrical ground. Multiple degradation modes, resulting in quantifiable optical loss, were found to occur during HV-/HV+ sequential stress, including corrosion of the external glass surface, encapsulant delamination (at its interfaces with the glass and the PV cell), internal haze formation (resulting from a chemical interaction between the glass and the encapsulant), corrosion and migration of the gridlines, and corrosion of the silicon nitride (Si x N y ) antireflective coating on the cell. The effects of these separate modes were examined using monolithic (e.g., glass or PV cell) and laminated-coupon (glass/encapsulant/glass or glass/encapsulant/cell/encapsulant/backsheet) specimens. Characterizations during and after unbiased accelerated testing at 85°C/85% relative humidity included spectrophotometry, optical microscopy, electron microscopy, and ellipsometry. For some module components (i.e., the glass and the Si x N y coating), the optical performance was determined through iterative analysis of empirical measurements. Concentrating on just their spectral effect, a novel model was then developed to estimate the transfer of light to the PV cell and the return of light from the PV module with simultaneous degradation mechanisms, which was compared with a mini-module previously subjected to HV-/HV+ stress. Here the model suggests that one third of the current loss observed for the mini-module can be attributed to the optical degradation of the packaging materials. The dominant degradation modes include encapsulant delamination and corrosion of the Si x N y coating. Recommendations are given so that the optical model may be improved relative to accelerated testing and validated relative to field aging.

14 SOLAR ENERGY↗

PLANET HUNTERS. V. A CONFIRMED JUPITER-SIZE PLANET IN THE HABITABLE ZONE AND 42 PLANET CANDIDATES FROM THE KEPLER ARCHIVE DATA

We report the latest Planet Hunter results, including PH2 b, a Jupiter-size (R{sub PL} = 10.12 ± 0.56 R{sub ⊕}) planet orbiting in the habitable zone of a solar-type star. PH2 b was elevated from candidate status when a series of false-positive tests yielded a 99.9% confidence level that transit events detected around the star KIC 12735740 had a planetary origin. Planet Hunter volunteers have also discovered 42 new planet candidates in the Kepler public archive data, of which 33 have at least 3 transits recorded. Most of these transit candidates have orbital periods longer than 100 days and 20 are potentially located in the habitable zones of their host stars. Nine candidates were detected with only two transit events and the prospective periods are longer than 400 days. The photometric models suggest that these objects have radii that range between those of Neptune and Jupiter. These detections nearly double the number of gas-giant planet candidates orbiting at habitable-zone distances. We conducted spectroscopic observations for nine of the brighter targets to improve the stellar parameters and we obtained adaptive optics imaging for four of the stars to search for blended background or foreground stars that could confuse our photometric modeling. We present an iterative analysis method to derive the stellar and planet properties and uncertainties by combining the available spectroscopic parameters, stellar evolution models, and transiting light curve parameters, weighted by the measurement errors. Planet Hunters is a citizen science project that crowd sources the assessment of NASA Kepler light curves. The discovery of these 43 planet candidates demonstrates the success of citizen scientists at identifying planet candidates, even in longer period orbits with only two or three transit events.

79 ASTRONOMY AND ASTROPHYSICS↗

Iterative Monte Carlo analysis of spin-dependent parton distributions

We present a comprehensive new global QCD analysis of polarized inclusive deep-inelastic scattering, including the latest high-precision data on longitudinal and transverse polarization asymmetries from Jefferson Lab and elsewhere. The analysis is performed using a new iterative Monte Carlo fitting technique which generates stable fits to polarized parton distribution functions (PDFs) with statistically rigorous uncertainties. Inclusion of the Jefferson Lab data leads to a reduction in the PDF errors for the valence and sea quarks, as well as in the gluon polarization uncertainty at x ≳ 0.1. Furthermore, the study also provides the first determination of the flavor-separated twist-3 PDFs and the d 2 moment of the nucleon within a global PDF analysis.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design and Synthesis of Selective Phosphodiesterase 4D (PDE4D) Allosteric Inhibitors for the Treatment of Fragile X Syndrome and Other Brain Disorders

Novel pyridine- and pyrimidine-based allosteric inhibitors are reported that achieve PDE4D subtype selectivity through recognition of a single amino acid difference on a key regulatory domain, known as UCR2, that opens and closes over the catalytic site for cAMP hydrolysis. The design and optimization of lead compounds was based on iterative analysis of X-ray crystal structures combined with metabolite identification. Selectivity for the activated, dimeric form of PDE4D provided potent memory enhancing effects in a mouse model of novel object recognition with improved tolerability and reduced vascular toxicity over earlier PDE4 inhibitors that lack subtype selectivity. The lead compound, 28 (BPN14770), has entered midstage, human phase 2 clinical trials for the treatment of Fragile X Syndrome.

60 APPLIED LIFE SCIENCES↗

Steady state scenario development with elevated minimum safety factor on DIII-D

On DIII-D, a high β scenario with minimum safety factor (q min ) near 1.4 has been optimized with new tools and shown to be a favourable candidate for long pulse or steady state operation in future devices. Furthermore, the new capability to redirect up to 5 MW of neutral beam injection (NBI) from on- to off-axis improves the ability to sustain elevated q min with a less peaked pressure profile. The observed changes increase the ideal magnetohydrodynamics (MHD) n = 1 mode β N limit thus providing a path forward for increasing the noninductive current drive fraction by operating at high β N . Quasi-stationary discharges free of tearing modes have been sustained at βN = 3.5 and β T = 3.6% for two current profile diffusion timescales (about 3 s) limited by neutral beam duration. The discharge performance has normalized fusion performance expected to give fusion gain Q ≈ 5 in a device the size of ITER. Analysis of the poloidal flux evolution and current drive balance show that the loop voltage profile is almost relaxed even with 25% of the current driven inductively, and q min remains elevated near 1.4. Our observations increase confidence that the current profile will not evolve to one unstable to a tearing mode. In preliminary tests a divertor heat flux reduction technique based on producing a radiating mantle with neon injection appears compatible with this operating scenario. 0D model extrapolations suggest it may be possible to push this scenario up to 100% noninductive current drive by raising β N . Similar discharges with q min = 1.5–2 were susceptible to tearing modes and off-axis fishbones, and with q min > 2 lower normalized global energy confinement time is observed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Testing predictions of electron scale turbulent pedestal transport in two DIII-D ELMy H-modes

In this study, we present linear and nonlinear gyrokinetic analyses in the pedestal region of two DIII-D ELMy H-mode discharges using the CGYRO code. The otherwise matched discharges employ different divertor configurations to investigate the impact of varying recycling and particle source on pedestal profiles. Linear gyrokinetic simulations find electrostatic ion-scale instabilities (ion temperature gradient and trapped electron modes, ITG-TEM) are present just inside the top of the pedestal with growth rates that are enhanced significantly by parallel velocity shear. In the sharp gradient region, E x B shearing rates are comparable or larger than ion scale growth rates, suggesting the suppression of ITG-TEM modes in this region. Instead, the electron temperature profiles are found to be correlated with and just above the electron temperature gradient (ETG) instability thresholds. Using gradients varied within experimental uncertainties, nonlinear electron-scale gyrokinetic simulations predict electron heat fluxes from ETG turbulence, that when added to neoclassical ion thermal transport simulated by NEO, account for 30-60% of the total experimental heat flux. In addition, the neoclassical electron particle flux is found to contribute significantly to the experimental fluxes inferred from SOLPS-ITER analysis. Additional nonlinear gyrokinetic simulations are run varying input gradients to develop a threshold-based reduced model for ETG transport, finding a relatively simple dependence on η e = L ne /L Te . Predictive transport simulations are used to validate this pedestal-specific ETG model, in conjunction with a model for neoclassical particle transport. In both discharges, the predicted electron temperatures are always overpredicted, indicative of the insufficient stiffness in the ETG pedestal model to account for all of the experimental electron thermal transport. In the case of the closed divertor discharge with lower particle source, the predicted electron density is close to the experiment, consistent with the magnitude of neoclassical particle transport in that discharge. However, the density profiles are overpredicted in the open divertor discharge (larger particle source), due to insufficient model transport. In conclusion, the implications for other mechanisms accounting for the remainder of transport in the sharp gradient region in the two discharges are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and Analysis Progress of ITER Diagnostic Equatorial Port #09

ITER is the world's largest fusion device currently under construction in the South of France with >50 diagnostic systems to be installed inside the port plugs (PPs), the interspace (IS), or the port cell region of various diagnostic ports. The plasma facing diagnostic first wall (DFW) and its supporting diagnostic shield modules (DSM) are designed to protect front-end diagnostics from plasma neutron and plasma radiation, while providing apertures for diagnostic access to the plasma. The design of ITER port plug structures including the DFW and the DSM is largely driven by the electromagnetic loads included on the PP structural components during plasma major disruptions and the vertical displacement events (VDEs). Unlike DFW and DSM, the design of diagnostic system, however, is likely driven by the steady-state thermal loads from plasma volumetric and surface heating and the dynamic response of the in-port components attached to the port-specific DSM or closure plate under transient loads induced on the vacuum vessel and the port extension during asymmetric VDEs. Three tenant diagnostic systems are integrated into the equatorial port 09. The toroidal interferometer/polarimeter, or TIP system, is installed in the left drawer (DSM3, left looking from plasma) for measuring the plasma density so to control the fuel input. The electron cyclotron emission (ECE) system is installed in the middle drawer (DSM2) to provide the high spatial and temporal resolution measurements of electron temperature evolution and the electron thermal transport inferences. The visible/infrared wide angle viewing system is installed in the right drawer (DSM1) to provide visible and infrared viewing and temperature data of the first wall for its protection in support of machine operation. The port plug integration design and multiphysics analyses are performed following port integration requirements including the weight limit (45 tones total), shut down dose rate limits, the cooling/heating and structural integrity validation. Mass distribution for TIP and ECE DSMs has been optimized to minimize the total weight by a new design of the boron carbide shielding pocket. Furthermore, the lightened DSM maintains its front-end load distribution and the structural stiffness with minimum impact to the DFW so to better protect on-board diagnostics; while still provides sufficient front-end stiffness for its structural integrity as well as the diagnostics function requirements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

JET ITER-Like Antenna Analysis Using the TOPICA Code

In this work, we carried out the analysis of the recently installed JET ITER-Like antenna with TOPICA code. Comparisons between TOPICA simulations and measurements taken during the actual experiment are instead part of the overview talk on the JET ITER-Like antenna [4]. As routinely done for all simulated antennas, TOPICA inputs are the technical drawings of the launcher and the accurate density and temperature profiles, which, in this case, have been provided by the JET team. The standard outputs are the input parameters of the antenna, namely the impedance matrix, the electric current distribution and the electric field pattern at the interface between the antenna region and the plasma column. This work, together with [4], provides an additional proof that the code can be adopted to predict the behavior of the JET ITER-Like antenna, and to confidently pass to the next step, i.e. using TOPICA for the challenging task of optimizing the complex design of the actual ITER antenna. More generally viewed, the possibility to reliably simulate the detailed geometry of an ICRF antenna, given a realistic plasma description, and to obtain the actual antenna input parameters, is of paramount importance to evaluate and predict the system performances, and to assist in system operation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

ITER Central Solenoid Alternate Pre-Compression Structure Concept and Analysis

The ITER Central Solenoid (CS) is comprised of six independent coils held together by a pre-compression support structure. This structure must provide enough preload to maintain sufficient coil-to-coil contact throughout the current pulse. End of burn (EOB) represents one extreme time-point when the currents in the CS3 coils oppose those of CS1 & CS2. The present baseline design uses nine tie plate pairs located on the coil ID and OD to achieve this pre-compression. While this is an efficient structural approach, the outer tie plates limit access to the coil OD and result in very tight tolerances over the 12.75 m tall toroidal field (TF) coil bore. An alternative pre-compression structure has been developed by the US ITER Project Office, which addresses both of these issues using only internal tension members. This allows clear access to the outer CS surface for plumbing and current feeders, and more reasonable OD tolerances. In addition, the Tension Rod pre-compression structure utilizes existing technology (such as hydraulic tensioner or Superbolt{reg_sign}), which streamlines initial preloading and subsequent adjustments. Structural and transient electromagnetic FEA of the tension rod concept demonstrates that the stresses, displacements, and preliminary Eddy current heat loads are within allowable limits. Fabrication estimates demonstrate no additional cost of the tension rods compared to the tie plates.

36 MATERIALS SCIENCE↗

Analysis of the ITER ICRH Decoupling and Matching System

The reference ITER ICRH load resilient matching system uses four 3dB hybrid power splitters. It is proposed to use a 'double stub' tuner (DST) configuration for the matching on the reference load and a decoupling system placed between the antenna plug and the matching system to reduce the mutual coupling effects and also to actively control the array current spectrum while requesting the same forward power from all 4 power sources. The paper analyzes (i) the optimization of the matching layout e.g. by varying the distance between the stubs and by the use of two capacitors taking into account the role of the decouplers on the matching requirements; (ii) the practical realization of the decouplers and their insertion into the circuit; (iii) the requests in voltage and current capabilities in the different parts of the system. The paper presents solutions for saving space and to decrease the ratings of the components. The computations are done with the array loading simulated by the TOPICA matrix.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Preliminary Neutronics Analysis of the ITER Toroidal Interferometer and Polarimeter Diagnostic Corner Cube Retroreflectors

ITER is an international project under construction in France that will demonstrate nuclear fusion at a power plant-relevant scale. The Toroidal Interferometer and Polarimeter (TIP) Diagnostic will be used to measure the plasma electron line density along 5 laser-beam chords. This line-averaged density measurement will be input to the ITER feedback-control system. The TIP is considered the primary diagnostic for these measurements, which are needed for basic ITER machine control. Therefore, system reliability & accuracy is a critical element in TIP’s design. There are two major challenges to the reliability of the TIP system. First is the survivability and performance of in-vessel optics and second is maintaining optical alignment over long optical paths and large vessel movements. Both of these issues greatly depend on minimizing the overall distortion due to neutron & gamma heating of the Corner Cube Retroreflectors (CCRs). These are small optical mirrors embedded in five first wall locations around the vacuum vessel, corresponding to certain plasma tangency radii. During the development of the design and location of these CCRs, several iterations of neutronics analyses were performed to determine and minimize the total distortion due to nuclear heating of the CCRs. The CCR corresponding to TIP Channel 2 was chosen for analysis as a good middle-road case, being an average distance from the plasma (of the five channels) and having moderate neutron shielding from its blanket shield housing. Results show that Channel 2 meets the requirements of the TIP Diagnostic, but barely. These results suggest other CCRs might be at risk of exceeding thermal deformation due to nuclear heating.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗