Search NASA⌕ Search

SEARCH · Search NASA

Results for “laser ion source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Investigation of a digitizer for the plastic scintillation detectors of time-of-flight mass measurements

A CAEN DT5742 digitizer has been investigated to process the fast signals from the photomultiplier tubes of the time-of-flight detectors for fast ion beams. A test setup consisting of two plastic scintillation detectors and a pulsed laser source provided signals which were recorded by the digitizer and systematically analyzed with different algorithms to derive the amplitude, rise time and arrival time of the detection signal. To obtain the best amplitude and time resolutions, various optimization techniques including peak fitting and signal smoothing, interpolation improvement, and time-walk correction by amplitude and rise time have been performed and compared in detail. Here we compared the time resolutions obtained by three digital algorithms of leading-edge, zero-crossing constant-fraction (ZC-CFD) and direct constant-fraction discriminations. Finally, we found that the best time-of-flight resolution between two PMTs can be achieved as 12 ps by the method using sample minimum for peak location and using the time-walk-resistant ZC-CFD with 4-point interpolation for timing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser and optical transport line for laser-based ion beam diagnostics and control in the SNS linear accelerator

We report our recent upgrade of the laser and optical transport line for the laser-based ion beam diagnostics (laser wire) system at the linear accelerator (linac) of the Spallation Neutron Source (SNS). A new light source based on diodepumped solid-state laser amplifiers has been developed to provide near diffraction-limited laser beam with a variety of pulse structures. The free-space optical transport line has been modified to include image relay optics with remote control, which greatly improved the laser beam quality and position stability at individual measurement stations. The upgraded system enables novel beam diagnostics/control capabilities including longitudinal profile measurement and high-energy proton beam extraction from the SNS linac.

Liu, Yun↗

Structured light approaches in laser-based plasma diagnostics

There is a growing demand for plasma diagnostics suitable for industrial plasma reactors employed in semiconductor nanofabrication, especially relevant to microelectronics and quantum information systems. Such reactors typically have limited optical access and pose considerable diagnostic challenges, including intense background emission, significant thermal loads, and contamination of optical viewports. In this study, we outline research into structured light techniques (laser beams with tailored spatial, temporal, or phase characteristics) that effectively overcome these issues using laser-induced fluorescence (LIF) as an example. The focus of presented diagnostics is on ion kinetics analysis within an industrial plasma source, although this approach is broadly applicable to other plasma systems and diagnostic contexts. We present a confocal LIF implementation using an axicon-generated Bessel annular beam, achieving spatial resolutions of approximately 5 mm at a focal distance of 300 mm, with potential improvements to about 1 mm. This approach matches conventional orthogonal LIF performance but requires only one optical port. Wavelength-modulation LIF employs nonlinear laser wavelength tuning to measure spectral line derivatives, suppressing background emission and enhancing details of spectral line shape. Additionally, we present new results on applying vortex beams (laser beams carrying orbital angular momentum, OAM) for LIF measurements in an industrial plasma device. These measurements enable simultaneous axial and tangential velocity determination using a single laser beam and have been tested with xenon ion transition. Initial quantification of results was performed. Together, these structured-light approaches provide robust, background-resilient, multi-dimensional diagnostics for complex plasma environments.

Romadanov, Ivan [Princeton Plasma Physics Laborato↗

Demonstration of plasma mirror capability for the OMEGA Extended Performance laser system

A plasma mirror platform was developed for the OMEGA-EP facility to redirect beams, thus enabling more flexible experimental configurations as well as a platform that can be used in the future to improve laser contrast. The plasma mirror reflected a short pulse focusing beam at 22.5° angle of incidence onto a 12.5 μm thick Cu foil, generating Bremsstrahlung and k α x rays, and accelerating ions and relativistic electrons. By measuring these secondary sources, the plasma mirror key performance metrics of integrated reflectivity and optical quality are inferred. It is shown that for a 5 ± 2 ps, 310 J laser pulse, the plasma mirror integrated reflectivity was 62 ± 13% at an operating fluence of 1670 J cm –2 , and that the resultant short pulse driven particle acceleration and x-ray generation indicate that the on target intensity was 3.1 × 10 18 W cm –2 , which is indicative of a good post-plasma mirror interaction beam optical quality. By deriving the plasma mirror performance metrics from the secondary source scalings, it was simultaneously demonstrated that the plasma mirror is ready for adoption in short pulse particle acceleration and high energy photon generation experiments using the OMEGA-EP system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Harnessing Ultra-Intense Long-Wave Infrared Lasers: New Frontiers in Fundamental and Applied Research

This review explores two main topics: the state-of-the-art and emerging capabilities of high-peak-power, ultrafast (picosecond and femtosecond) long-wave infrared (LWIR) laser technology based on CO2 gas laser amplifiers, and the current and advanced scientific applications of this laser class. The discussion is grounded in expertise gained at the Accelerator Test Facility (ATF) of Brookhaven National Laboratory (BNL), a leading center for ultrafast, high-power CO2 laser development and a National User Facility with a strong track record in high-intensity physics experiments. We begin by reviewing the status of 9–10 μm CO2 laser technology and its applications, before exploring potential breakthroughs, including the realization of 100 terawatt femtosecond pulses. These advancements will drive ongoing research in electron and ion acceleration in plasma, along with applications in secondary radiation sources and atmospheric energy transport. Throughout the review, we highlight how wavelength scaling of physical effects enhances the capabilities of ultra-intense lasers in the LWIR spectrum, expanding the frontiers of both fundamental and applied science.

43 PARTICLE ACCELERATORS↗

Early-stage dynamics of chloride ion–pumping rhodopsin revealed by a femtosecond X-ray laser

Chloride ion–pumping rhodopsin (ClR) in some marine bacteria utilizes light energy to actively transport Cl – into cells. How the ClR initiates the transport is elusive. Here, we show the dynamics of ion transport observed with time-resolved serial femtosecond (fs) crystallography using the Linac Coherent Light Source. X-ray pulses captured structural changes in ClR upon flash illumination with a 550 nm fs-pumping laser. High-resolution structures for five time points (dark to 100 ps after flashing) reveal complex and coordinated dynamics comprising retinal isomerization, water molecule rearrangement, and conformational changes of various residues. Combining data from time-resolved spectroscopy experiments and molecular dynamics simulations, this study reveals that the chloride ion close to the Schiff base undergoes a dissociation–diffusion process upon light-triggered retinal isomerization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Origin and effect of film sub-stoichiometry on ultraviolet, ns-laser damage resistance of hafnia single layers

Understanding the origin of laser damage-prone precursors in high index materials such as hafnia holds the key to the development of laser damage-resistant multilayer dielectric coated optics for high power and energy laser systems. In this study, we investigate the source of sub-stoichiometry, a potent laser damage precursor, in hafnia films produced by an ion beam sputtering (IBS) deposition method and the effect of such defects on the film performance upon ns ultraviolet (UV) laser (8 ns, 355 nm) exposure. Chemical analysis of data obtained via Rutherford backscattering spectroscopy (RBS) suggests that hafnia films deposited at two different planetary locations from the same deposition run exhibit anisotropic and location-dependent stoichiometries. While the oxygen-to-hafnium ratio is at the stoichiometric value of 2 for the hafnia film at the edge location, the ratio is significantly deviated and is 1.7 for that deposited at the planetary center. The sub-stoichiometric hafnia films display a much lower 1-on-1 damage onset at 1.6 ± 0.2 J/cm 2 compared to 2.3 ± 0.2 J/cm 2 in a stoichiometric film. The low damage performance films also have an over three times higher damage density at fluences above initiation. Coupled with Monte Carlo simulations, we reveal that sub-stoichiometry is primarily attributed to preferential removal of oxygen during film deposition by the bombardment of energetic reflected argon neutrals. The resulting oxygen deficiencies create the sub-bandgap states which facilitate the strong laser energy coupling and reduce the resistance to laser-induced damage in the hafnia single layer films.

36 MATERIALS SCIENCE↗

Towards Portable Laser Desorption Postionization Mass Spectrometry Utilizing Microchip Laser Pulses

A 355 nm, 1.5 ns, up to 1 kHz microchip laser system has been tested to both yield ablation spots and postionize material within a plasma plume. A 30 µJ pulse energy microchip laser successfully ablated all samples: 6601 aluminum, 316 and 304 stainless steel, and Mo metal. While visible ablation craters were observed on all samples mentioned above, the stainless-steel samples displayed visible color changes in the resolidified iron, indicating ionization with the 355 nm pulses during ablation. Additionally, when used to intercept a plasma plume of Cs 2 CO 3 made with a separate laser system, the microchip laser pulses yielded Cs + emission signal otherwise not observed. With these experiments completed, the microchip laser has been successfully verified for readiness to be integrated into the front end of a mass spectrometer system as the ion source.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A multi-sheath model for highly nonlinear plasma wakefields

An improved description for nonlinear plasma wakefields with phase velocities near the speed of light is presented and compared against fully kinetic particle-in-cell simulations. These wakefields are excited by intense particle beams or lasers pushing plasma electrons radially outward, creating an ion bubble surrounded by a sheath of electrons characterized by the source term S≡−1enp(ρ−Jz/c), where ρ and Jz are the charge and axial current densities, respectively. Previously, the sheath source term was described phenomenologically with a positive-definite function, resulting in a positive definite wake potential. In reality, the wake potential is negative at the rear of the ion column which is important for self-injection and accurate beam loading models. To account for this, we introduce a multi-sheath model in which the source term, S, of the plasma wake can be negative in regions outside the ion bubble. Using this model, we obtain a new expression for the wake potential and a modified differential equation for the bubble radius. Numerical results obtained from these equations are validated against particle-in-cell simulations for unloaded and loaded wakes. The new model provides accurate predictions of the shape and duration of trailing bunch current profiles that flatten plasma wakefields. It is also used to design a trailing bunch for a desired longitudinally varying loaded wakefield. We present beam loading results for laser wakefields and discuss how the model can be improved for laser drivers in future work. Finally, we discuss differences between the predictions of the multi- and single-sheath models for beam loading.

Dalichaouch, T. N. (ORCID:0000000247350150)↗

Single-Cell Metabolomics with Rapid Determination of Chemical Formulas from Isotopic Fine Structures

Metabolomic measurements can provide functional readouts of cellular states and phenotypes. Here, we present a protocol for single-cell metabolomics that permits direct untargeted detection of a broad number of metabolites under ambient conditions, without the need for sample processing, and with high confidence in the discovery and identification of the molecular formulas for detected metabolites. This protocol describes combining fiber-based laser ablation electrospray ionization (f-LAESI) with a 21 Tesla Fourier transform ion cyclotron resonance mass spectrometer (21T-FTICR-MS) to obtain high confidence molecular formula information about detected metabolites. The f-LAESI source utilizes mid-infrared laser ablation through a sharp optical fiber tip, affording direct ambient analysis of cells without the need for sample processing. Using the 21T-FTICR-MS as a mass analyzer enabled measurement of the isotopic fine structure (IFS) for numerous metabolites simultaneously from single cells, and the IFSs were in turn computationally processed to rapidly determine the corresponding elemental compositions. This metabolomics technique complements other single cell omics measurement methods, helping to resolve complex molecular interactions that take place within cells unattainable from single cell transcriptomic and proteomics methods.

mass spectrometry, FTICR, FTMS, ultrahigh mass res↗

Dual-energy fast neutron imaging using tunable short-pulse laser-driven sources

Here a novel dual-energy fast neutron imaging technique is presented using short-pulse laser-driven neutron sources to leverage their inherent adaptive spectral control to enable 3D volume segmentation and reconstruction. Laser-accelerated ion beams incident onto secondary targets create directional, broadband, MeV-class neutrons. Synthetic radiographs are produced of multi-material objects using ion and neutron spectra derived from analytic and numerical models. It is demonstrated that neutron images generated from small changes to the neutron spectra, controlled by altering the initial laser conditions, are sufficient to isolate materials with differing attenuation coefficients. This is first demonstrated using a simplistic combinatorial isolation method and then by employing more advanced reconstruction algorithms to reduce artifacts and generate a segmentation volume of the constituent materials.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laser-plasma ion beam booster based on hollow-channel magnetic vortex acceleration

Laser-driven ion acceleration provides ultrashort, high-charge, low-emittance beams, which are desirable for a wide range of high-impact applications. Yet after decades of research, a significant increase in maximum ion energy is still needed. This paper introduces a quality-preserving staging concept for ultraintense ion bunches that is seamlessly applicable from the nonrelativistic plasma source to the relativistic regime. Full three-dimensional particle-in-cell simulations prove robustness and capture of a high-charge proton bunch, suitable for readily available and near-term laser facilities.

43 PARTICLE ACCELERATORS↗

Single-ion addressing via trap potential modulation in global optical fields

To date, individual addressing of ion qubits has relied primarily on local Rabi or transition frequency differences between ions created via electromagnetic field spatial gradients or via ion transport operations. Alternatively, it is possible to synthesize arbitrary local one-qubit gates by leveraging local phase differences in a global driving field. Here we report individual addressing of 40 Ca + ions in a two-ion crystal using axial potential modulation in a global gate laser field. We characterize the resulting gate performance via one-qubit randomized benchmarking, applying different random sequences to each co-trapped ion. We identify the primary error sources and compare the results with single-ion experiments to better understand our experimental limitations. These experiments form a foundation for the universal control of two ions, confined in the same potential well, with a single gate laser beam.

quantum computing↗

In situ calibration of charged particle spectrometers on the OMEGA Laser Facility using 241 Am and 226 Ra sources

Charged particle spectrometry is a critical diagnostic to study inertial-confinement-fusion plasmas and high energy density plasmas. The OMEGA Laser Facility has two fixed magnetic charged particle spectrometers (CPSs) to measure MeV-ions. In situ calibration of these spectrometers was carried out using 241 Am and 226 Ra alpha emitters. The alpha emission spectrum from the sources was measured independently using surface-barrier detectors (SBDs). The energy dispersion and broadening of the CPS systems were determined by comparing the CPS measured alpha spectrum to that of the SBD. The calibration method significantly constrains the energy dispersion, which was previously obtained through the measurement of charged particle fusion products. Overall, a small shift of 100 keV was observed between previous and the calibration done in this work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermal energy transport in laser-driven high x-ray conversion efficiency metallic silver nanowire foams

Here, we report on record brightness from Ag x-ray emission obtained using a novel laser-produced plasma source. The reported K-shell conversion efficiency of nearly 1% with a radiant energy of ≈ 0.6 kJ/sr from Ag ions is the highest presently recorded and is about twofold greater than more conventional metal-lined cavity targets. He-like Ag ions are the dominant radiators at ≈ 22.7 keV, which contrast the x-ray sources from other pulse power facilities that produce K-shell x-rays from Auger processes in near-neutral ions driven by the nonthermal hot electrons produced in the Z-pinch implosion. The reported x-ray emission was produced from a 4-mm-diameter, 4-mm-long underdense silver nanowire target at 10⁢ mg/⁢cm 3 . The National Ignition Facility laser beams deposited ≈ 1000 kJ of 3ω light into the target with a ≈ 400 TW, 2.5 ns square pulse. Finally, we show via comparisons of data with radiation-hydrodynamics simulations that flux-limited classical thermal energy transport models are inadequate in correctly modeling the behavior of these non-local thermodynamic equilibrium plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Generative modeling enables molecular structure retrieval from Coulomb explosion imaging

Capturing the structural changes that molecules undergo during chemical reactions in real space and time is a long-standing dream and an essential prerequisite for understanding and ultimately controlling femtochemistry. A key approach to tackle this challenging task is Coulomb explosion imaging, which benefited decisively from recently emerging high-repetition-rate X-ray free-electron laser sources. With this technique, information on the molecular structure is inferred from the momentum distributions of the ions produced by the rapid Coulomb explosion of molecules. Retrieving molecular structures from these distributions poses a highly non-linear inverse problem that remains unsolved for molecules consisting of more than a few atoms. Here, we address this challenge using a diffusion-based Transformer neural network. We show that the network reconstructs unknown molecular geometries from ion-momentum distributions with a mean absolute error below one Bohr radius, which is half the length of a typical chemical bond.

Artificial Intelligence (cs.AI)↗

Implementation of a portable diagnostic system for Thomson scattering measurements on an electrothermal arc source

To fulfill the increasing needs of diagnostic support for researchers in plasma technology, a portable diagnostic package (PDP) equipped for both laser Thomson scattering (TS) and optical emission spectroscopy has been designed and constructed at Oak Ridge National Laboratory (ORNL), aiming to measure the temperature and number density of electrons and temperatures of ions in plasma devices. The PDP has been initially implemented on a high density and low temperature electrothermal arc source (ET-arc) at ORNL to test its TS capability. TS from the plasmas in the ET-arc has been obtained using the PDP. The electron temperature and number density were determined from TS spectra. These results were then compared to measurements from previous studies on the ET-arc. The TS diagnostic measured 0.8 ± 0.1, 1.3 ± 0.2, and 0.7 ± 0.1 eV and (4.4 ± 0.5) × 1021, (5.9 ± 0.7) × 1021, and (4.3 ± 0.5) x 1021 m-3, respectively, from three lines of sight that transect the plasma column.

He, Z. (ORCID:0000000183159882)↗

Versatile tape-drive target for high-repetition-rate laser-driven proton acceleration

We present the development and characterization of a high-stability, multi-material, multi-thickness tape-drive target for laser-driven acceleration at repetition rates of up to 100 Hz. The tape surface position was measured to be stable on the sub-micrometre scale, compatible with the high-numerical aperture focusing geometries required to achieve relativistic intensity interactions with the pulse energy available in current multi-Hz and near-future higher repetition-rate lasers ( > kHz). Long-term drift was characterized at 100 Hz demonstrating suitability for operation over extended periods. The target was continuously operated at up to 5 Hz in a recent experiment for 70,000 shots without intervention by the experimental team, with the exception of tape replacement, producing the largest data-set of relativistically intense laser–solid foil measurements to date. This tape drive provides robust targetry for the generation and study of high-repetition-rate ion beams using next-generation high-power laser systems, also enabling wider applications of laser-driven proton sources.

47 OTHER INSTRUMENTATION↗