Life test summary and high vacuum tests of 10 mlb resistojets
Long term life test and vacuum tests of high temperature resistojets using ammonia and hydrogen propellants
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Long term life test and vacuum tests of high temperature resistojets using ammonia and hydrogen propellants
Long term life test and vacuum tests of high temperature resistojets, using ammonia and hydrogen propellants
Accelerated life tests were performed on CMOS microcircuits to predict their long term reliability. The consistency of the CMOS microcircuit activation energy between the range of 125 C to 200 C and the range 200 C to 250 C was determined. Results indicate CMOS complexity and the amount of moisture detected inside the devices after testing influences time to failure of tested CMOS devices.
The initial checkout of the control moment gyro system for the astronaut stabilizer maneuvering unit is described, and the test results are presented. The life test proceeded smoothly to its completion, and problem areas encountered in the engineering tests are described. These tests included command rate and torquer current transfer, cage and lock, static inverter and signal noise, dynamic response, closed loop drift rate, and gimbal disturbance torque evaluation tests.
Testing on a variety of secondary silver-zinc (Ag-Zn) cells has continued at MSFC for the past six years. The latest test involves a 350 amp/hr cell design that was cycled for 12 months and has undergone approximately 5400 low-earth-orbit cycles as well as 12 deep discharges. This test is not only a life test of these cells, but it also addresses different methods of storing the cells between deep discharges. Also, impedance measurements are made on one of the packs during periodic deep discharges. It is hoped that this will give a good correlation between the health of a cell and its impedance.
The life test results of five 16 low pressure CW CO2 lasers with a nominal output of 1 watt are presented. One laser quickly died while the remaining four lasers reached half power output at 38,000, 40,000, 40,000 and 40,000 hours respectively. These results show the potential for a 50,000 hour laser while the average life of the 16 tested lasers was 22,500 hours. It is further indicated that the cathode sputtering products, which settle on the glass walls of the cathode sleeve, form an increasingly heavy film as the laser ages.
Life testing of electron-bombardment cesium ion engine designed for power-to-thrust ratio of 160 kw/lb
The goal of this study is to verify the long term stability of Yb14MnSb11 for high performance thermoelectric (TE) couples. Three main requirements need to be satisfied to ensure the long term stability of thermoelectric couples: 1) stable thermoelectric properties, 2) stable bonding interfaces, and 3) adequate sublimation suppression. The efficiency of the couple is primarily based on the thermoelectric properties of the materials selected for the couple. Therefore, these TE properties should exhibit minimal degradation during the operating period of the thermoelectric couples. The stability of the bonding is quantified by low contact resistances of the couple interfaces. In order to ensure high efficiency, the contact resistances of the bonding interfaces should be negligible. Sublimation suppression is important because the majority of thermoelectric materials used for power generation have peak figures of merit at temperatures where sublimation rates are high. Controlling sublimation is also essential to preserve the efficiency of the couple. During the course of this research, three different life tests were performed with Yb14MnSb11 coupons. TE properties of Yb14MnSb11 exhibited no degradation after 6 months of aging at 1273K, and the electrical contact resistance between a thin metallization layer and the Yb14MnSb11 remained negligible after 1500hr aging at 1273K. A sublimation suppression layer for Yb14MnSb11 was developed and demonstrated for more than 18 months with coupon testing at 1273K. These life test data indicate that thermoelectric elements based on Yb14MnSb11 are a promising technology for use in future high performance thermoelectric power generating couples.
Heat pipe life tests described in the literature have seldom been conducted on a systematic basis. Typically one or more heat pipes are built and tested for an extended period at a single temperature with simple condenser loading. This paper describes an approach to generate carefully controlled data that can conclusively establish heat pipe operating life with material-fluid combinations capable of extended operation. Approximately 10 years of operational life might be compressed into 3 years of laboratory testing through a combination of increased temperature and mass fluence. Two specific test series have been identified and include: investigation of long term corrosion rates based on the guidelines contained in ASTM G-68-80 (using 7 heat pipes); and investigation of corrosion trends in a cross correlation sequence at various temperatures and mass fluences based on a central composite test design (using 9 heat pipes). The heat pipes selected for demonstration purposes are fabricated from a Mo-44.5%Re alloy with a length of 0.3 meters and a diameter of 1.59 cm(to conserve material) with a condenser to evaporator length ratio of approximately 3. The wick is a crescent annular design formed from 400-mesh Mo-Re alloy material hot isostatically pressed to produce a final wick core of 20 microns or less.
The Clouds and the Earth's Radiant Energy System (CERES) elevation scan bearings lubricated with Pennzane SHF X2000 and 2% lead naphthenate (PbNp) were life tested for a seven-year equivalent Low Earth Orbit (LEO) operation. The bearing life assembly was tested continuously at an accelerated and normal rate using the scanning patterns developed for the CERES Earth Observing System AM-1 mission. A post-life-test analysis was performed on the collected data, bearing wear, and lubricant behavior.
Spacecraft component ceramic capacitor life tests and failure modes
Thermionic converter life-test results and failure mechanisms noting braze failure, collector deposit, emitter warpage and separation and cesium reservoir leak
Life test facility for SERT II mercury ion thruster
The application of high temperature accelerated test techniques was shown to be an effective method of microcircuit defect screening. Comprehensive microcircuit evaluations and a series of high temperature (473 K to 573 K) life tests demonstrated that a freak or early failure population of surface contaminated devices could be completely screened in thirty two hours of test at an ambient temperature of 523 K. Equivalent screening at 398 K, as prescribed by current Military and NASA specifications, would have required in excess of 1,500 hours of test. All testing was accomplished with a Texas Instruments' 54L10, low power triple-3 input NAND gate manufactured with a titanium- tungsten (Ti-W), Gold (Au) metallization system. A number of design and/or manufacturing anomalies were also noted with the Ti-W, Au metallization system. Further study of the exact nature and cause(s) of these anomalies is recommended prior to the use of microcircuits with Ti-W, Au metallization in long life/high reliability applications. Photomicrographs of tested circuits are included.
Life tests were conducted on a 22-N (5-lb) hydrazine rocket thruster which incorporates the latest technology to obtain long life from the catalyst bed. A spring mechanism surrounding the catalyst bed continually applies compression to the catalyst bed to prevent the formation of any void channels. The research rocket thruster was tested over an operational cycle of both steady state and pulse firing which simulated a possible space station duty cycle. The thruster ran as expected for about 40 hours, or 3.2 times 10 to the 6th power N-sec (7.2 times 10 to the 5th power lb-sec) total impulse. Subsequently, some thrust chamber pressure decreases were noted during long steady state test periods. After 60.2 hours of run time, tests had to be terminated due to a blockage in the propellant injector tube which occurred during heating of the thruster by a heat lamp. A chemical analysis of the catalyst indicated that iron and nickel metals had poisoned some of the catalyst, thereby causing a degradation in performance. It was determined that a contaminated barrel of hydrazine was the source of the metal poisoning.
Two main cathodes have successfully completed 2800 and 1980 cycles and three neutralizers, 3928, 3050, and 2850 cycles in ongoing cycle life tests of flight-type cathode-isolator-vaporizer and neutralizer-isolator-vaporizer assemblies for the 4.45 mN 8-cm Hg ion thruster system. Each cycle included one hour of cathode operation. Starting and operating conditions simulated those expected in a typical auxiliary propulsion mission duty cycle. The cycle life test results are presented along with results of an insert comparison test which led to the selection of a rolled foil insert type for the 8-cm Engineering Model Thruster cathodes.
Two main cathodes have successfully completed 2800 and 1980 cycles and three neutralizers, 3928, 3050, and 2850 cycles in ongoing cycle life tests of flight-type cathode-isolator-vaporizer and neutralizer-isolator-vaporizer assemblies for the 4.45 mN 8-cm Hg ion thruster system. Each cycle included one hour of cathode operation. Starting and operating conditions simulated those expected in a typical auxiliary propulsion mission duty cycle. This paper presents the cycle life test results and also results of an insert comparison test which led to the selection of a rolled foil insert type for the 8-cm Engineering Model Thruster cathodes.
Life cycle tests being run on the 50 A lightweight nickel hydrogen flight battery are discussed and the preliminary results are presented.