Search NASA⌕ Search

SEARCH · Search NASA

Results for “nominal operating cell temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

72 records · Page 4

Development and Validation of a High-Vacuum Thermal Conductivity Testbed for Aerospace Interface Materials

Thermal Interface Materials (TIMs) are critical components in spacecraft thermal management systems, where thermal performance is strongly influenced by vacuum conditions, interface contact resistance, and layered metallic joint behavior. However, manufacturer-reported thermal conductivity values are often derived under idealized conditions and may not accurately represent performance within operational aerospace applications. To address this limitation, the Testbed for Advanced Interface Materials in Vacuum (TAIMV) was developed as a modular vacuum-compatible thermal conductivity characterization platform capable of evaluating aerospace-relevant TIM configurations under both ambient and high-vacuum environments. The testbed was derived from the ASTM C1044-16 guarded hot plate methodology and incorporates interchangeable layers of stainless steel coupon geometries, independently controlled main and guard heaters, embedded resistance temperature detectors (RTDs), thermocouples, multi-layer insulation (MLI), and a temperature-controlled cold plate to characterize through-thickness thermal gradients across layered interfaces. In the current configuration, interface compression is limited to the nominal contact pressure generated by the experimental stack assembly. Initial experimental campaigns were conducted at ambient pressure and below 1×10-5 torr for vacuum cases using multiple interface materials including Braycote 601EF and Krytox-based greases across a range of thermal operating conditions. In parallel, a coupled numerical Python thermal model was developed to predict temperature distribution throughout the stack while accounting for conduction, radiation, and parasitic heat transfer pathways and effective interface resistance effects. Experimental measurements and numerical predictions showed consistent thermal trends across multiple operating conditions and environmental states. Results also revealed measurable differences between ambient and vacuum thermal behavior, demonstrating the importance of interface resistance, parasitic heat transfer mechanisms, and stack geometry in determining effective thermal performance within layered thermal interfaces. The presented work establishes a foundation for future thermal model correlation efforts and expanded characterization of aerospace thermal interface materials under representative environmental conditions. Future work will focus on the integration of a load cell system to enable controlled pressure-dependent characterization of thermal interface materials under compressive loading. This capability will allow investigation of the influence of contact pressure on effective thermal conductivity, interface resistance, and thermal performance within layered aerospace thermal interfaces under representative operational conditions.

Thermal Development Testing↗

An Update on the Lithium-Ion Cell Low-Earth-Orbit Verification Test Program

A Lithium-Ion Cell Low-Earth-Orbit Verification Test Program is being conducted by NASA Glenn Research Center to assess the performance of lithium-ion (Li-ion) cells over a wide range of low-Earth-orbit (LEO) conditions. The data generated will be used to build an empirical model for Li-ion batteries. The goal of the modeling will be to develop a tool to predict the performance and cycle life of Li-ion batteries operating at a specified set of mission conditions. Using this tool, mission planners will be able to design operation points of the battery system while factoring in mission requirements and the expected life and performance of the batteries. Test conditions for the program were selected via a statistical design of experiments to span a range of feasible operational conditions for LEO aerospace applications. The variables under evaluation are temperature, depth-of-discharge (DOD), and end-of-charge voltage (EOCV). The baseline matrix was formed by generating combinations from a set of three values for each variable. Temperature values are 10 C, 20 C and 30 C. Depth-of-discharge values are 20%, 30% and 40%. EOCV values are 3.85 V, 3.95 V, and 4.05 V. Test conditions for individual cells may vary slightly from the baseline test matrix depending upon the cell manufacturer s recommended operating conditions. Cells from each vendor are being evaluated at each of ten sets of test conditions. Cells from four cell manufacturers are undergoing life cycle tests. Life cycling on the first sets of cells began in September 2004. These cells consist of Saft 40 ampere-hour (Ah) cells and Lith ion 30 Ah cells. These cells have achieved over 10,000 cycles each, equivalent to about 20 months in LEO. In the past year, the test program has expanded to include the evaluation of Mine Safety Appliances (MSA) 50 Ah cells and ABSL battery modules. The MSA cells will begin life cycling in October 2006. The ABSL battery modules consist of commercial Sony hard carbon 18650 lithium-ion cells configured in series and parallel combinations to create nominal 14.4 volt, 3 Ah packs (4s-2p). These modules have accumulated approximately 3000 cycles. Results on the performance of the cells and modules will be presented in this paper. The life prediction and performance model for Li-ion cells in LEO will be built by analyzing the data statistically and performing regression analysis. Cells are being cycled to failure so that differences in performance trends that occur at different stages in the life of the cell can be observed and accurately modeled. Cell testing is being performed at the Naval Surface Warfare Center in Crane, IN.

Reid, Concha M.↗

Moderate temperature rechargeable sodium batteries

Cells utilizing the organic electrolyte, NaI in triglyme, operated at approx. 130 C with Na(+) - intercalating cathodes. However, their rate and stability were inadequate. NaAlCl4 was found to be a highly useful electrolyte for cell operation at 165-190 C. Na(+) intercalating chalcogenides reacted with NaAlCl4 during cycling to form stable phases. Thus, VS2 became essentially VS2Cl, with reversible capacity of approx 2.8 e(-)/V, and a mid-discharge voltage of approx 2.5V and 100 deep discharge cycles were readily achieved. A positive electrode consisting of VCl3 and S plus NaAlCl4 was subjected to deep-discharge cycles 300 times and it demonstrated identity with the in-situ-formed BSxCly cathode. NiS2 and NiS which are not Na(+)-intercalating structures formed highly reversible electrodes in NaAlCl4. The indicated discharge mechanism implies a theoretical capacity 4e(-)/Ni for NiS2 and 2e(-)/Ni for NiS. The mid-discharge potentials are, respectively, 2.4V and 2.1V. A Na/NiS2 cell cycling at a C/5 rate has exceeded 500 deep discharge cycles with 2.5e(-)/Ni average utilization. A 4 A-hr nominal capacity prototype Na/NiS2 cell was tested at 190 C. It was voluntarily terminated after 80 cycles. Further development, particularly of cathode structure and hardware should produce a battery capable of at least 50-W-hr/lb and more than 1000 cycles.

Abraham, K. M.↗

High Voltage Solar Concentrator Experiment with Implications for Future Space Missions

This paper describes the design, development, fabrication, and test of a high performance, high voltage solar concentrator array. This assembly is believed to be the first ever terrestrial triple-junction-cell solar array rated at over 1 kW. The concentrator provides over 200 W/square meter power output at a nominal 600 Vdc while operating under terrestrial sunlight. Space-quality materials and fabrication techniques were used for the array, and the 3005 meter elevation installation below the Tropic of Cancer allowed testing as close as possible to space deployment without an actual launch. The array includes two concentrator modules, each with a 3 square meter aperture area. Each concentrator module uses a linear Fresnel lens to focus sunlight onto a photovoltaic receiver that uses 240 series-connected triple-junction solar cells. Operation of the two receivers in series can provide 1200 Vdc which would be adequate for the 'direct drive' of some ion engines or microwave transmitters in space. Lens aperture width is 84 cm and the cell active width is 3.2 cm, corresponding to a geometric concentration ratio of 26X. The evaluation includes the concentrator modules, the solar cells, and the materials and techniques used to attach the solar cells to the receiver heat sink. For terrestrial applications, a finned aluminum extrusion was used for the heat sink for the solar cells, maintaining a low cell temperature so that solar cell efficiency remains high.

Mehdi, Ishaque S.↗

Hydrogen desorption using honeycomb finned heat exchangers integrated in adsorbent storage systems

One of the main technical hurdles associated with adsorbent based hydrogen storage systems is relative to their ability to discharge hydrogen effectively, as dictated by fuel cell requirements. In this study, a new honeycomb finned heat exchanger concept was examined to evaluate its potential as a heat transfer system for hydrogen desorption. A bench scale 0.5 L vessel was equipped with the proposed heat exchanger, filled with MOF-5® adsorbent material. The heating power, required to desorb hydrogen, was provided by a 100 W electric heater placed in the center of the honeycomb structure. Two desorption tests, at room temperature and under cryogenic temperatures, were carried out to evaluate the hydrogen desorption performance of the proposed system under different operating conditions. The bench scale vessel performance was verified from both an experimental and a modeling point of view, demonstrating the ability to desorb about 45% of the adsorbed hydrogen in reduced time and applying low heating power. Further modeling analyses were also carried out showing the potential of the proposed system to reach high hydrogen discharging rates at cryogenic temperature conditions and operating pressures between 100 bar and 5 bar. The proposed adsorption system also demonstrated to be able to discharge all the available hydrogen in less than 500 s operating at cryogenic conditions and with a nominal heating power of 100 W.

25 ENERGY STORAGE↗

Rapid Biochemical Analysis on the International Space Station (ISS): Preparing for Human Exploration of the Moon and Mars

The Lab-on-a-Chip Application Development - Portable Test System, known as LOCAD-PTS, was launched to the International Space Station (ISS) aboard Space Shuttle Discovery (STS-116) on December 9th,2006. Since that time, it has remained onboard ISS and has been operated by the crew on 10 separate occasions LOCAD-PTS is a handheld device for rapid biochemical analysis; it consists of a spectrophotometer, a series of interchangeable cartridges, a pipette and several clean/sterilized swabbing kits to obtain samples from ISS surfaces. Sampling, quantitative analysis and data retrieval is performed onboard, therefore reducing the need to return samples to Earth. Less than 20 minutes are required from sampling to data, significantly faster than existing culture-based methods on ISS, which require 3-5 days. Different cartridges are available for the detection of different target molecules (simply by changing the formulation within each cartridge), thereby maximizing the benefit and applications addressed by a single instrument. Initial tests on ISS have focused on the detection of the bact.erial macromolecule endotoxin, a component of bacterial cell walls. LOCAD-PTS detects endotoxin with a cartridge that contains a formulation known as Limulus Amebocyte Lysate (LAL) assay. LAL is derived from blood of the horseshoe crab, Limulus polyphemus, and detects enodotoxin with an enzyme cascade that triggers generation Of a yellow colored dye, p-nitroanaline. The more p-nitroanaline product, the more endotoxin is in the original sample. To enable quantitative analysis, the absorbance of this color is measured by LOCAD-PTS through a 395 nm filter and compared with an internal calibration curve, to provide a reading on the LED display that ranges from 0.05 Endotoxin Units (EU)/ml to 5 EU/ml. Several surface sites were analyzed within ISS between March 2007 and February 2008, including multiple locations in the US Laboratory Destiny, Node 1 Unity, AMock, and Service Module Zvezda. The goals of this initial study were to i) test the cleanliness of reagents/supplies on orbit, ii) test the crew's ability to collect and process a sample in microgravity without contamination, iii) demonstrate nominal function of the LOCAD-PTS, and iv) provide a general survey of endotoxin within the ISS. The surface sites varied greatly in terms of their frequency-of-use and material texture/composition; from relatively smooth aluminum, to fabric, to the room temperature vulcanizing (RTV) rubber of a Extravehicular Mobility Unit (EMU) spacesuit. Results showed that: i) the swabbing kits and reagents remained clean on orbit, ii) the crew could collect and process a sample without contamination, and iii) the LOCAD-PTS functioned nominally in > 99% of the 55 tests completed. We will present detailed results of the survey of endotoxin on ISS surfaces. These results and technology are important in the near-term - by providing an extra tool in the toolbox for ISS microbial monitoring. They are also important in the longer term as valuable preparation for human exploration of the Moon and Mars. One of the proposed science goals for the human exploration of Mars will be to detect and characterize any indigenous biological molecules that may exist on the Martian surface. To achieve that goal, the crew must have the technology available onboard to differentiate indigenous biology from any terrestrial biological material brought to Mars by the spacecraft and crew (termed 'forward contamination'). The LAL assay is already one of the official methods used by NASA's planetary protection program to certify cleanliness of interplanetary robotic spacecraft prior to launch; and therefore endotoxin is a good marker of forward contamination (as well as other microbial molecules detectable with LOCAD-PTS e.g. box-1, 3-glucan and lipoteichoic acid). Furthermore, the distribution and abundance of these molecules on the ISS provides a good indicator of what to expect on the Crew Exploratioehicle Orion, the lunar lander Antares, and future crewed spacecraft destined for Mars. In addition, technology such as LOCAD-PTS has been proposed to help evaluate forward contamination during lunar surface operations by the crew, as preparation for the human exploration of Mars.

Maule, J.↗

AGC-4 Disassembly Report

The Advanced Reactor Terminology Graphite Research and Development program is currently measuring irradiated material property changes in several grades of nuclear graphite to predict behavior and operating performance within the core of these new high temperature reactor designs. The Advanced Graphite Creep (AGC) experiment, consisting of six irradiation capsules, will generate the irradiated graphite performance data for the Very High Temperature Reactor operating conditions. All six capsules in the experiment conducted at Idaho National Laboratory will be irradiated in the Advanced Test Reactor, disassembled in the Hot Fuel Examination Facility, and examined at the Idaho National Laboratory Research Center. This is the disassembly report describing the disassembly, shipment, post irradiation inspection, and storage of the graphite specimens contained within the AGC 4 irradiation test series capsule (the fourth irradiation capsule of the series). AGC 4 was irradiated in the Advanced Test Reactor (ATR) East Flux Trap (EFT) during ATR Cycle 157D, 158A, 162A, 162B, 164A, 164B, 166A, and Cycle 166B. Approximately 3.6 dpa was achieved. Desired experiment temperatures were exceeded by at least 100C during the second Cycle of irradiation due to the insertion of the KJRR experiment. The capsule was removed from the ATR and transferred to the Hot Fuel Examination Facility on May 15, 2020 and eventually unloaded into the Hot Fuel Examination Facility (HFEF) Decon Cell through Penetration 2D on February 26, 2021. It was moved to the HFEF Main Cell Window 3M for disassembly on March 15, 2021. Disassembly and specimen extraction began March 18, 2021, and packaging of the graphite specimens was completed on April 16, 2021. Several anomalies were noted, specifically that the radiological dose rates were nominally an order of magnitude higher than that of the previous AGC experiments. This report summarizes the disassembly of the AGC 4 experiment.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

AGC-4 Disassembly Report

The Advanced Reactor Terminology Graphite Research and Development program is currently measuring irradiated material property changes in several grades of nuclear graphite to predict behavior and operating performance within the core of these new high temperature reactor designs. The Advanced Graphite Creep (AGC) experiment, consisting of six irradiation capsules, will generate the irradiated graphite performance data for the Very High Temperature Reactor operating conditions. All six capsules in the experiment conducted at Idaho National Laboratory will be irradiated in the Advanced Test Reactor, disassembled in the Hot Fuel Examination Facility, and examined at the Idaho National Laboratory Research Center. This is the disassembly report describing the disassembly, shipment, post irradiation inspection, and storage of the graphite specimens contained within the AGC 4 irradiation test series capsule (the fourth irradiation capsule of the series). AGC 4 was irradiated in the Advanced Test Reactor (ATR) East Flux Trap (EFT) during ATR Cycle 157D, 158A, 162A, 162B, 164A, 164B, 166A, and Cycle 166B. Approximately 3.6 dpa was achieved. Desired experiment temperatures were exceeded by at least 100C during the second Cycle of irradiation due to the insertion of the KJRR experiment. The capsule was removed from the ATR and transferred to the Hot Fuel Examination Facility on May 15, 2020 and eventually unloaded into the Hot Fuel Examination Facility (HFEF) Decon Cell through Penetration 2D on February 26, 2021. It was moved to the HFEF Main Cell Window 3M for disassembly on March 15, 2021. Disassembly and specimen extraction began March 18, 2021, and packaging of the graphite specimens was completed on April 16, 2021. Several anomalies were noted, specifically that the radiological dose rates were nominally an order of magnitude higher than that of the previous AGC experiments. This report summarizes the disassembly of the AGC 4 experiment.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

MODELING THE IMPACT OF ELEVATED MERCURY IN DEFENSE WASTE PROCESSING FACILITY MELTER FEED ON THE MELTER OFF-GAS SYSTEM-PRELIMINARY REPORT

The Defense Waste Processing Facility (DWPF) is currently evaluating an alternative Chemical Process Cell (CPC) flowsheet to increase throughput. It includes removal of the steam-stripping step, which would significantly reduce the CPC processing time and lessen the sampling needs. However, its downside would be to send 100% of the mercury that comes in with the sludge straight to the melter. For example, the new mercury content in the Sludge Batch 5 (SB5) melter feed is projected to be 25 times higher than that in the SB4 with nominal steam stripping of mercury. This task was initiated to study the impact of the worst-case scenario of zero-mercury-removal in the CPC on the DWPF melter offgas system. It is stressed that this study is intended to be scoping in nature, so the results presented in this report are preliminary. In order to study the impact of elevated mercury levels in the feed, it is necessary to be able to predict how mercury would speciate in the melter exhaust under varying melter operating conditions. A homogeneous gas-phase oxidation model of mercury by chloride was developed to do just that. The model contains two critical parameters pertaining to the partitioning of chloride among HCl, Cl, Cl{sub 2}, and chloride salts in the melter vapor space. The values for these parameters were determined at two different melter vapor space temperatures by matching the calculated molar ratio of HgCl (or Hg{sub 2}Cl{sub 2}) to HgCl{sub 2} with those measured during the Experimental-Scale Ceramic Melter (ESCM) tests run at the Pacific Northwest National Laboratory (PNNL). The calibrated model was then applied to the SB5 simulant used in the earlier flowsheet study with an assumed mercury stripping efficiency of zero; the molar ratio of Cl-to-Hg in the resulting melter feed was only 0.4, compared to 12 for the ESCM feeds. The results of the model run at the indicated melter vapor space temperature of 650 C (TI4085D) showed that due to excessive shortage of chloride, only 6% of the mercury fed is expected to get oxidized, mostly as HgCl, while the remaining mercury would exist either as elemental mercury vapor (90%) or HgO (4%). Noting that the measured chloride level in the SB5 qualification sample was an order of magnitude lower than that used in the SB5 simulant, the degree of chloride shortage will be even greater. As a result, the projected level of HgCl in the actual SB5 melter exhaust will be even lower than 6% of the total mercury fed, while that of elemental mercury is likely to be greater than 90%. The homogeneous oxidation of mercury in the off-gas was deemed to be of primary importance based on the postulation that mercury and other volatile salts form submicron sized aerosols upon condensation and thus remain largely in the gas stream downstream of the quencher where they can deposit in the off-gas lines, Steam-Atomized Scrubbers (SAS), and High-Efficiency Mist Eliminator (HEME). Formation of these submicron semi-volatile salts in the condensate liquid is considered to be unlikely, so the liquid phase reactions were considered to be less important. However, subsequent oxidation of mercury in the liquid phase in the off-gas system was examined in a simplified model of the off-gas condensate. It was found that the condensate chemistry was consistent with further oxidation of elemental mercury to Hg{sub 2}Cl{sub 2} and conversion of HgO to chlorides. The results were consistent with the available experimental data. It should also be noted that the model predictions presented in this report do not include any physically entrained solids, which typically account for much of the off-gas carryover on a mass basis. The high elemental mercury vapor content predicted at the DWPF Quencher inlet means that physically entrained solids could provide the necessary surface onto which elemental mercury vapor could condense, thereby coating the solids as well as the internal surfaces of the off-gas system with mercury. Clearly, there are many process benefits to be gained by removing the steam-stripping step from the CPC cycle. The goal of this task was to study what adverse impact the zero-mercury-removal scenario would have on the DWPF melter off-gas system operation. It is stressed again that this study was intended to be scoping in nature, so the results presented in this report are preliminary. Any further substantiation of these results for actual implementation into the DWPF flowsheet would require an in-depth modeling study of all three reaction zones, including the aqueous-phase reactions in the quencher, OGCT, Steam Atomized Scrubber (SAS), and off-gas condenser with recirculated condensate, and the proof-of-principle experiments.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

MODELING THE IMPACT OF ELEVATED MERCURY IN DEFENSE WASTE PROCESSING FACILITY MELTER FEED ON THE MELTER OFF-GAS SYSTEM - PRELIMINARY REPORT

The Defense Waste Processing Facility (DWPF) is currently evaluating an alternative Chemical Process Cell (CPC) flowsheet to increase throughput. It includes removal of the steam-stripping step, which would significantly reduce the CPC processing time and lessen the sampling needs. However, its downside would be to send 100% of the mercury that come in with the sludge straight to the melter. For example, the new mercury content in the Sludge Batch 5 (SB5) melter feed is projected to be 25 times higher than that in the SB4 with nominal steam stripping of mercury. This task was initiated to study the impact of the worst-case scenario of zero-mercury-removal in the CPC on the DWPF melter off-gas system. It is stressed that this study is intended to be scoping in nature, so the results presented in this report are preliminary. In order to study the impact of elevated mercury levels in the feed, it is necessary to be able to predict how mercury would speciate in the melter exhaust under varying melter operating conditions. A homogeneous gas-phase oxidation model of mercury by chloride was developed to do just that. The model contains two critical parameters pertaining to the partitioning of chloride among HCl, Cl, Cl{sub 2}, and chloride salts in the melter vapor space. The values for these parameters were determined at two different melter vapor space temperatures by matching the calculated molar ratio of HgCl (or Hg{sub 2}Cl{sub 2}) to HgCl{sub 2} with those measured during the Experimental-Scale Ceramic Melter (ESCM) tests run at the Pacific Northwest National Laboratory (PNNL). The calibrated model was then applied to the SB5 simulant used in the earlier flowsheet study with an assumed mercury stripping efficiency of zero; the molar ratio of Cl-to-Hg in the resulting melter feed was only 0.4, compared to 12 for the ESCM feeds. The results of the model run at the indicated melter vapor space temperature of 650 C (TI4085D) showed that due to excessive shortage of chloride, only 6% of the mercury fed is expected to get oxidized, mostly as HgCl, while the remaining mercury would exist either as elemental mercury vapor (90%) or HgO (4%). Noting that the measured chloride level in the SB5 qualification sample was an order of magnitude lower than that used in the SB5 simulant, the degree of chloride shortage will be even greater. As a result, the projected level of HgCl in the actual SB5 melter exhaust will be even lower than 6% of the total mercury fed, while that of elemental mercury is likely to be greater than 90%. The homogeneous oxidation of mercury in the off-gas was deemed to be of primary importance based on the postulation that mercury and other volatile salts form submicron sized aerosols upon condensation and thus remain largely in the gas stream downstream of the quencher where they can deposit in the off-gas lines, Steam-Atomized Scrubbers (SAS), and High-Efficiency Mist Eliminator (HEME). Formation of these submicron semi-volatile salts in the condensate liquid is considered to be unlikely, so the liquid phase reactions were considered to be less important. However, subsequent oxidation of mercury in the liquid phase in the off-gas system was examined in a simplified model of the off-gas condensate. It was found that the condensate chemistry was consistent with further oxidation of elemental mercury to Hg{sub 2}Cl{sub 2} and conversion of HgO to chlorides. The results were consistent with the available experimental data. It should also be noted that the model predictions presented in this report do not include any physically entrained solids, which typically account for much of the off-gas carryover on a mass basis. The high elemental mercury vapor content predicted at the DWPF Quencher inlet means that physically entrained solids could provide the necessary surface onto which elemental mercury vapor could condense, thereby coating the solids as well as the internal surfaces of the off-gas system with mercury. Clearly, there are many process benefits to be gained by removing the steam-stripping step from the CPC cycle. The goal of this task was to study what adverse impact the zero-mercury-removal scenario would have on the DWPF melter off-gas system operation. It is stressed again that this study was intended to be scoping in nature, so the results presented in this report are preliminary. Any further substantiation of these results for actual implementation into the DWPF flowsheet would require an in-depth modeling study of all three reaction zones, including the aqueous-phase reactions in the quencher, OGCT, Steam Atomized Scrubber (SAS), and off-gas condenser with recirculated condensate, and the proof-of-principle experiments.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

National Solar Radiation Database (NSRDB)

The National Solar Radiation Database (NSRDB) is a serially complete collection of meteorological and solar irradiance data sets for the United States and a growing list of international locations for 1998-2023. The NSRDB is updated annually and provides foundational information to support U.S. Department of Energy programs, research, industry and the general public. The NSRDB provides time-series data at 30-minute resolution of resource averaged over surface cells of 0.038 degrees in both latitude and longitude, or nominally 4 km in size. Additionally time series data at 5 minutes for the US and 10 minutes for North, Central and South America at 2 km resolution are produced from the next generation of GOES satellites and made available from 2019. The solar radiation values represent the resource available to solar energy systems. The data was created using cloud properties which are generated using the AVHRR Pathfinder Atmospheres-Extended (PATMOS-x) algorithms developed by the University of Wisconsin. Fast all-sky radiation model for solar applications (FARMS) in conjunction with the cloud properties, and aerosol optical depth (AOD) and precipitable water vapor (PWV) from ancillary source are used to estimate solar irradiance (GHI, DNI, and DHI). The Global Horizontal Irradiance (GHI) is computed for clear skies using the REST2 model. For cloud scenes identified by the cloud mask, FARMS is used to compute GHI and FARMS DNI is used to compute the Direct Normal Irradiance (DNI). The PATMOS-X model uses radiance images in visible and infrared channels from the Geostationary Operational Environmental Satellite (GOES) series of geostationary weather satellites. Ancillary variables needed to run REST2 and FARMS (e.g., aerosol optical depth, precipitable water vapor, and albedo) are derived from NASA's Modern Era-Retrospective Analysis (MERRA-2) dataset. Temperature and wind speed data are also derived from MERRA-2 and provided for use in NREL's System Advisor Model (SAM) to compute PV generation.

aerosol↗

Study of the influence of heat sources on the out-of-pile calibration curve of calorimetric cells used for nuclear energy deposition quantification

At present the Jules Horowitz Reactor is under construction in Cadarache research center of CEA 'French Alternative Energies and Atomic Energy Commission' center located in the south-east of France. This new Material Testing Reactor (MTR) will be operational in late 2019 and will allow the generation of a new experimental potential (up to 20 irradiation devices simultaneously) and new harsh conditions such as higher neutron fluxes (5.10{sup 14} n.cm{sup -2}.s{sup -1} for E≥1 MeV), faster material ageing and higher nuclear heating (up to 20 W/g for nominal capacity of 100 MW). In nuclear research field, the control and the measurement of the nuclear heating (energy deposition rate per mass unit induced by the interactions of radiations with matter) is crucial to carry out accurate studies on ageing of materials and on the behavior of nuclear fuels under irradiation. Several experiments need to know precisely this key parameter in order to establish dedicated thermal conditions. The measurement of the nuclear heating inside MTRs is realized by three kinds of sensors: single-cell calorimeter, differential calorimeter and gamma thermometer. One scientific objective of the IN-CORE program, between CEA and Aix-Marseille University in 2009, is to improve the nuclear heating measurement. In this context a new multi-sensor device, called CARMEN, was made. This device contains in particular a differential calorimeter which was designed to measure the nuclear heating in the periphery of OSIRIS reactor (a MTR located at Saclay, France) up to 2 W/g and tested during two irradiation campaigns. Results obtained during these campaigns showed that temperatures reached inside the calorimeter are higher than ones obtained during the preliminary out-of-pile calibration experiments. For instance for 1.74 W/g, the in-pile temperature of the calorimeter rod is equal to 305 deg. C against 225 deg. C in laboratory conditions by simulating the nuclear heating by Joule Effect inside the calorimeter cell head. This discrepancy is higher than in previous experiments because the calorimeter owns a high sensitivity. Consequently, a new prototype was created and instrumented by other heat sources in order to impose an energy deposition on the calorimetric cell structure (in particular in the base) and to improve the calibration step in out-of-pile conditions. In this paper, on the first part a detailed description of the new calorimetric sensor will be given. On the second part, the experimental response of the sensor obtained for several internal heating conditions will be shown. The influence of these conditions on the calibration curve will be discussed. Then the response of this prototype will be also presented for different external cooling fluid conditions (in particular flow temperature). In this part, the comparison between the in-pile and out-of-pile experimental results will be performed. On the last part, these out-of-pile experiments will be completed by 2D axisymmetrical thermal simulations with the CEA code CAST3M using Finite Elements Method. After a comparison between experimental and numerical works, improvements of the sensor prototype will be studied (new heat sources). (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SB5 WITH THE ESTIMATED IMPACT OF LOW TEMPERATURE ALUMINUM DISSOLUTION: PRELIMINARY FRITS FOR MELT RATE TESTING

Composition projections for Sludge Batch 5 (SB5) were developed to evaluate possible impacts of the Al-dissolution process on the availability of viable frit compositions for vitrification at the DWPF. The study included two projected SB5 compositions that bound potential outcomes (or degrees of effectiveness) of the Al-dissolution process, as well as a nominal SB5 composition projection based on the results of the recent Al-dissolution demonstration at SRNL. A Nominal Stage assessment was used to evaluate the two SB5 projections combined with an array of 19,305 frit compositions over a range of waste loading (WL) values against the DWPF process control models. The Nominal Stage results allowed for the down-selection of a small number of frits that provided reasonable projected operating windows (typically 25 to 40 wt %) and permitted some compositional flexibility (i.e., the ability to further tailor the frit to improve melt rate). Variation Stage assessments were then performed using the down-selected frits and the two SB5 composition projections with variation applied to each sludge component. The Variation Stage results showed that the operating windows were somewhat reduced in width, as expected when sludge variation is applied. Three of the down-selected frits continued to perform well for both SB5 projections through the Variation Stage, providing WL windows of approximately 26 to 35 wt %. The maximum WLs were limited by a processing constraint, TL, rather than a waste form affecting constraint (e.g., nepheline crystallization) in the Variation Stage assessments. Subsequent Nominal Stage assessments were performed with an updated SB5 projection based on the results of the Al-dissolution demonstration performed in the SRNL Shielded Cells facility (representing 40% removal of Al). The three frits identified in the earlier paper studies continued to perform well with this updated projection. The available operating windows were slightly wider, although maximum WL was limited by both the TL and nepheline constraints for all three frits. Changes in the projected SB5 composition are anticipated before processing begins at the DWPF, which will likely require additional paper study assessments as well as experimental frit development studies. This study identifies several frits which provide insight into potential operating windows for SB5 vitrification in DWPF. However, until experimental studies can be performed to gain information on melt rate and other parameters needed to optimize frit selection, no final frit recommendation can be made. Information regarding melt rate cannot be inferred from the paper study results. Experimental studies to evaluate this critical factor in DWPF processing must be performed to support frit optimization for any projected sludge composition. Five frit compositions were identified for melt rate testing at SRNL with simulated SB5 Case F SRAT product. The results of these tests will be used to evaluate the impact of the frit components--particularly B{sub 2}O{sub 3} and Na{sub 2}O--that are expected to influence melt rate for SB5-like sludges. The results of the melt rate testing will be documented in a separate report and will be used to help guide the frit recommendation process as the final SB5 composition becomes clearer.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Acoustic sensors for fission gas characterization: R and D skills devoted to innovative instrumentation in MTR, non-destructive devices in hot lab facilities and specific transducers for measurements of LWR rods in nuclear plants

First of all, we will present the main principle of the method. A piezoelectric transducer, driven by a pulse generator, generates the acoustic waves in a cavity that may be the fuel rod or a chamber connected to an instrumented rod. The composition determination consists in measuring the time of flight of the acoustic signal emitted. The pressure can be estimated by a calibration process, above the measurement of the amplitude of the signal. Two projects will then be detailed. The first project consists in the development of advanced instrumentation for in-pile experiments in Material Testing Reactor. It constitutes a main goal for the improvement of the nuclear fuel behavior knowledge. This acoustic method was tested with success during a first experiment called REMORA 3, and the results were used to differentiate helium and fission gas release kinetics under transient operating conditions. This experiment was lead at OSIRIS reactor (CEA Saclay, France). As a first step of the development program, we performed in-pile tests on the most sensitive component, i.e., the piezoelectric transducer. For this purpose, the active part of this sensor has been qualified on gamma and neutron radiations and at high temperature. Various industrial piezo-ceramics were exposed to a high activity Cobalt source for few days. The cumulated dose was ranged from 50 kGy up to 2 MGy. Next, these devices were placed inside a Material Test Reactor to investigate their reliability towards neutron fluence. The final fluence after 150 days of irradiation was up to 1.6.10{sup 21}n/cm{sup 2} (for thermal neutron). Irreversible variations have been measured. Next, a specific sensor has been implemented on an instrumented fuel rod and tested in the frame of a REMORA 3 Irradiation test. It was the first experiment under high mixed, temperature neutron and gamma flux. A first irradiation phase took place in March 2010 in the OSIRIS reactor and in November 2010 for the second step of the irradiation. The instrumented fuel rod incorporating the ultrasonic gas composition sensor was finally irradiated during 2 weeks in nominal conditions. Neutronics calculation will be performed in order to calculate the thermal and fast neutron fluence and the gamma dose absorbed by acoustic sensor. A first evaluation gives a thermal fluence about 4,5.10{sup 19} n/cm{sup 2}, a fast neutrons fluence about 4,5.1018 n/cm{sup 2} and a total gamma dose up to 0,25 MGy The maximal temperature during the irradiation test was about 150 C. Although the ultrasonic sensor appears to be damaged, the optimization of the electrical attack parameters and the development of a new signal processing maintain the measurement feasibility up the end of the irradiation campaign. It was the first time that the composition of fission gas has been monitored all along an irradiation experiment in a MTR, giving access to the gas release kinetics. New researches involve thick film transducers produced by screen-printing process in order to propose piezoelectric structures for harsh temperature and irradiation measurements. The second project consists in the development of a non-destructive device that can be directly applied on a LWR fuel rod. The problem to be solved relates to the measurement of the fission gas pressure and composition in a fuel rod using a non-destructive method. Fuel rod internal pressure is one of the safety criteria applied in nuclear power analyses. This criterion must be verified in order to avoid any fuel-cladding gap reopening risk and therefore any local clad ballooning. Apart from the safety implications, this parameter is also a fuel behaviour indicator and reflects the overall fuel performance in operation, but also during shipping and long-term storage. Rod internal pressure is one criterion amongst others, like cladding corrosion, against which the acceptable fuel burn-up limit is set. A sensor has been achieved in 2007. A full-scale hot cell test of the internal gas pressure and composition measurement by an acoustic sensor was conducted successfully between 2008 and 2010 on 5 high burn-up MOX fuel rods and 2 very high burn-up UO{sub 2} fuel rods in LECA Facility at Cadarache Centre. An improvement of this sensor has been proposed, allowing us to divide by two the uncertainty on the pressure measurement. In the case of hot-cell measurements, viscous liquid can be used to couple the sensor with the rod. For gas content with a pressure exceeding 15 bars and a 10% Xe/Kr ratio, such coupling may reduce relative acoustic method accuracy by ±7% for pressure measurement result and ±0.25 % for the assessment of gas composition. These results make it possible to demonstrate the feasibility of the technique on LWR fuel rods. The transducer and the associated methodology are now operational for non-destructive measurements in hot lab facilities and allow characterising the fission gas without puncturing the fuel rods. Up to now, any other non-destructive method can be proposed. A next step will be the development of an industrial application in a fuel storage pool in order to perform a large number of measurements on a fuel assembly in nuclear plants.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Dynamic Self-Locking of an OEO Containing a VCSEL

A method of dynamic self-locking has been demonstrated to be effective as a means of stabilizing the wavelength of light emitted by a vertical-cavity surface-emitting laser (VCSEL) that is an active element in the frequency-control loop of an optoelectronic oscillator (OEO) designed to implement an atomic clock based on an electromagnetically- induced-transparency (EIT) resonance. This scheme can be considered an alternative to the one described in Optical Injection Locking of a VCSEL in an OEO (NPO-43454), NASA Tech Briefs, Vol. 33, No. 7 (July 2009), page 33. Both schemes are expected to enable the development of small, low-power, high-stability atomic clocks that would be suitable for use in applications involving precise navigation and/or communication. To recapitulate from the cited prior article: In one essential aspect of operation of an OEO of the type described above, a microwave modulation signal is coupled into the VCSEL. Heretofore, it has been well known that the wavelength of light emitted by a VCSEL depends on its temperature and drive current, necessitating thorough stabilization of these operational parameters. Recently, it was discovered that the wavelength also depends on the microwave power coupled into the VCSEL. This concludes the background information. From the perspective that led to the conception of the optical injection-locking scheme described in the cited prior article, the variation of the VCSEL wavelength with the microwave power circulating in the frequency-control loop is regarded as a disadvantage and optical injection locking is a solution of the problem of stabilizing the wavelength in the presence of uncontrolled fluctuations in the microwave power. The present scheme for dynamic self-locking emerges from a different perspective, in which the dependence of VCSEL wavelength on microwave power is regarded as an advantageous phenomenon that can be exploited as a means of controlling the wavelength. The figure schematically depicts an atomic-clock OEO of the type in question, wherein (1) the light from the VCSEL is used to excite an EIT resonance in selected atoms in a gas cell (e.g., 87Rb atoms in a low-pressure mixture of Ar and Ne) and (2) the power supplied to the VCSEL is modulated by a microwave signal that includes components at beat frequencies among the VCSEL wavelength and modulation sidebands. As the VCSEL wavelength changes, it moves closer to or farther from a nearby absorption spectral line, and the optical power transmitted through the cell (and thus the loop gain) changes accordingly. A change in the loop gain causes a change in the microwave power and, thus, in the VCSEL wavelength. It is possible to choose a set of design and operational parameters (most importantly, the electronic part of the loop gain) such that the OEO stabilizes itself in the sense that an increase in circulating microwave power causes the VCSEL wavelength to change in a direction that results in an increase in optical absorption and thus a decrease in circulating microwave power. Typically, such an appropriate choice of operational parameters involves setting the nominal VCSEL wavelength to a point on the shorter-wavelength wing of an absorption spectral line.

Strekalov, Dmitry↗

Magnification Determination for AGHCF Metallographic Images

Metallographic images generated in the Alpha Gamma Hot Cell Facility (AGHCF) have been used for quantitative and qualitative characterization of irradiated metallic fuel pins. Individual high-magnification images (micrographs) contained in AGHCF file folders and experimental notebooks are in the form of polaroid photographs labeled with AGHCF identification number, magnification, and surface condition (as-polished or etched). Low magnification composite images (photomosaics) are also available for fuel cross sections, for radial strips from the fuel center to the cladding outer diameter, and for circumferential strips of the cladding and outer fuel region. The individual images do not have scale bars. Only a few of the composite images contain scale bars. The purpose of this work is to describe and apply methods for checking the magnification (50X to 500X) of individual images and for determining the magnification (~25X to ~100X) of composite images. The metallographic images used to verify and/or determine magnification were generated during the 1989 to 1993 timeframe for cross sections of U-10Zr/HT9 fuel rods irradiated in EBR-II and for cross sections of irradiated U-10Zr/HT9 fuel-rod samples following elevated-temperature tests conducted in the out-of-pile AGHCF Fuel Behavior Test Apparatus (FBTA). Procedures are documented in the AGHCF Operations Manual for preparation of metallographic samples, for calibration verification, and for constructing composites from individual images. Calibration verification of magnification was performed at least semiannually. One standard used for calibration verification was a glass slide with vertical lines indicating distances of 1 mm, 0.1 mm and 0.01mm. Guidance is provided in the current work for determining magnification from images of the standard. In addition to the periodic calibration verification, consistency checks are recommended to verify the magnification of images taken between the routine calibration verifications. For cladding samples with or without significant fuel-cladding chemical interaction (FCCI), images taken at different magnifications (e.g., 150X and 200X) of the unaffected cladding thickness can be compared. This process is independent of changes in cladding thickness due to swelling and creep. For images taken at only one magnification of cladding regions with no FCCI, the cladding thickness determined from the images may be compared to the nominal as-built cladding thickness (15.0 ± 0.5 mils for examples used in current work)). This procedure works best for cladding that has not experienced significant swelling and/or creep (e.g., ≤2% circumferential strain at the cladding outer surface). Composite images were constructed by pasting together higher magnification images and photographing the composite to generate a negative from which the hard-copy photograph was developed. The primary purpose of the composite images was to identify interesting areas of the fuel and cladding for imaging at higher magnification. However, procedures are recommended in the current work for determining composite magnifications to allow quantitative characterization of the fuel. Composites are not recommended for determining cladding thickness or FCCI depth because magnifications are too low (generally ≤110X) and image contrast is low. Fuel cross-section composites were created by pasting together 50X or 75X images. The nominal magnification for the photographed fuel cross-section composites is 25.4X. A more precise magnification can be determined by comparing the average cladding outer diameter measured from the composite to the average cladding outer diameter measured by profilometry. Radial-strip composites were constructed by pasting together high-magnification (150X or 250X) images. The nominal magnification of radial-strip composites photographs is about 100X. A more precise method for determining the magnification of radial strips is to compare the cladding thick

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Monitoring of Double-Stud Wall Moisture Conditions in the Northeast

BSC TO5 Task 2.2 Monitoring of Double Stud Wall Moisture Conditions in the Northeast Field test data available for wood moisture contents, temperature, and relative humidity. STRUCTURE - House - Devens, MA 01432 Three double-stud assemblies were compared: 12-in. ocSPF, 12-in. cellulose, and 5.5-in. ocSPF at the exterior of a double-stud wall (to approximate conventional 2 x 6 wall construction and insulation levels, acting as a control wall). These assemblies were repeated on the north and south orientations, for a total of six assemblies. Data were collected from December 2011 through July 2014, capturing three winters of operation in various states. Winter 2011-2012 was very mild (warm) and the house had very low interior relative humidity (RH) because it was unoccupied. Winter 2012-2013 was colder and the house had very high (40%-50%) interior RH until the ventilation system was put into operation (mid-February 2013). Winter 2013-2014 was very cold, but the ventilation system was operated, resulting in moderate interior RHs. Under "normal" interior conditions (functioning ventilation system, wintertime RH 10%-30%), ocSPF walls (both 12 in. and 5.5 in.) with latex paint as interior vapor control (nominally Class III, but possibly more vapor open) showed low risk; all sheathing moisture contents (MCs) remained lower than 20%. However, the 12-in. cellulose wall had MCs higher than 20% on the north side. In addition, the cellulose wall sheathing-insulation interface had high RH conditions. Under high interior humidity loading (nonfunctional ventilation system, 40%-50% interior RH), all test walls showed MCs and sheathing-insulation interface RHs well into the high risk range. The cellulose walls showed particularly high MCs (sheathing in excess of 30%), while the ocSPF walls showed MCs in the 18%-25% range. In addition, the monitoring showed evidence of liquid water condensation (which can result in quick degradation) in all walls; the condensation was substantial in the cellulose walls. These condensation issues occurred on the north and south sides. But in all walls, during each summer after a winter of wetting, moisture levels fell well into the safe range. Based on the difference between the winters, it is clear that interior RH can have a tremendous effect on the performance of enclosure systems, in terms of interstitial condensation risks, when using more vapor-open interior finishes such as latex paint. The ocSPF walls showed consistently lower MCs and interface RH levels than the cellulose walls. Although air leakage cannot be eliminated as a possibility, it is likely that at the thicknesses applied, the ocSPF provided reasonable vapor control (1.5-3.5 perms when combined with Class III latex paint) under normal loading conditions. The collected data were analyzed in terms of ASHRAE Standard 160 criteria (tabulating hours with RH and temperatures that support mold growth), using the calculated surface RH at the sheathing-insulation interface. All north-facing walls failed through all three winters; in particular, there were large numbers of failure hours during the high humidity winter (2012-2013). Sheathing-insulation interface temperatures and RHs during the high humidity winter showed many hours with mold risk conditions (high humidity and sufficient temperature for mold growth).

Array↗

A Preliminary Analysis of Dose Rates Associated with ITER CVCS Equipment/Area Location

A preliminary analysis of the ITER Chemical and Volume Control System (CVCS) Area was performed to assess dose rates outside the walls and ceiling of the facility after 1.5 years of operation at shutdown, 2 days, and 10 days after shutdown. For this purpose a simplified Monte Carlo computer model was developed using the MCNP (MCNP5 Ver. 1.51) code. Two components are included: the smaller filter tank and the larger ion exchanger. These pieces of equipment are associated with the Integrated Blanket ELM Divertor Primary Heat Transfer System, which will have the largest dose rates associated with activated corrosion products during operation in comparison with other systems. The ion exchanger contained two source regions, a 1.2-m-thick resin bed above a 0.55 m-thick skirt, and a 0.8-m-thick water region. The filter constituted an additional source. Thus the model consisted of three sources (filter, resin, water), homogeneously distributed within the appropriate source regions. However, much of the results (that address individual isotopes) are presented with the two sources in the ion exchanger combined. In these cases the sources are referred to as the 'ion exchanger source' and the 'filter source.' Dimensions for the facility and components, as well as source isotopes and strengths, and material densities, were supplied by US ITER. Because of its simplification, the model does not contain pipes. Consequently, radiation streaming through pipe penetrations, radiation emanating from the pipes, and shielding from the pipes were not considered in this analysis. Dose rates on the outside of two walls and the ceiling were calculated. The two walls are labeled as the 'long' wall (aligned with the X-axis) and the 'short' wall (aligned with the Y-axis). These walls and ceiling were nominally set to 30-cm-thick concrete. In the original analysis, standard concrete (2.3 g/cc density) was used. In addition to the shielding walls/ceiling, a floor and an additional wall opposite the long wall were added for photon scattering contributions. These were both 10-cm-thick, standard concrete structures. Other components (tanks, pipes, etc.), that were not included in the model, would potentially add additional scattering and shielding. Possibly these additional effects will be addressed in a later, more detailed analysis. The room was 29.6 m in length (X-axis), but was limited to 15 m in the model. The inside width (Y axis) and height (Z axis) were 4 m and 3.4 m, respectively. The origin for the model was located inside the room at the corner opposite the long wall and adjacent to the short wall at the floor level. The room was filled with air at standard temperature and pressure. The stainless steel (SS304) wall thicknesses for the ion exchanger and filter were 2.2 cm and 0.8 cm, respectively. The axial center of the filter was located 140 cm from the short wall and 100 cm from the long wall (outer surface). The axial center of the ion exchanger was located 440 cm from the short wall and 250 cm from the long wall (inner surface). The resin was assumed to be a homogeneous mixture of equal atom density fractions of hydrogen and carbon* at a specified density of 1.136 g/cc. The filter material was assumed to be homogeneous carbon at a specified density of 1.8 g/cc. If the filter media were stainless steel and the accumulated activity were the same, the dose rate outside the filter would be lower, provided the density of the stainless steel sintered filter material is significantly higher than 1.8g/cc. The densities of the water and air were assumed to be 1.0 g/cc and 1.096E-3 g/cc, respectively. The model included 10 small volumes placed outside the model adjacent to the wall at locations where the dose rates were expected to be highest and which showed to a degree the fall-off of the dose rate with distance along a particular wall or ceiling. These 'tally cells' are shown in Fig. 2 and are described in Table 1. Each cell had dimensions of 50 cm x 50 cm x 1 cm and was oriented so that the 1-cm-thick dimension was perpendicular to the wall against which the cell was located. Also, smaller tally volumes were placed at 5 cm (updated model), 30 cm, 50 cm, and 100 cm from each source, both radially from the outside of each component at the height of each source mid-plane, and vertically, along the axial centerline, above the ion-exchanger and below the filter. (For the ion exchanger, the vertical distance was limited to 75 cm because of interference from the ceiling.) These tally regions can be seen in Fig. 3. Each cell had dimensions of 5 cm x 5 cm x 1 cm, oriented so that the 1-cm-thick dimension was perpendicular to the X, Y or Z axis.

08 HYDROGEN↗