Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical flow cell”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Continuous culture of anaerobic fungi enables growth and metabolic flux tuning without use of genetic tools

Anaerobic gut fungi (AGF) have potential to valorize lignocellulosic biomass owing to their diverse repertoire of carbohydrate-active enzymes (CAZymes). However, AGF metabolism is poorly understood, and no stable genetic tools are available to manipulate growth and metabolic flux to enhance production of specific targets, e.g., cells, CAZymes, or metabolites. Herein, a cost-effective, Arduino-based, continuous-flow anaerobic bioreactor with online optical density control is presented to probe metabolism and predictably tune fluxes in Caecomyces churrovis. Varying the C. churrovis turbidostat setpoint titer reliably controlled growth rate (from 0.04 to 0.20 h −1 ), metabolic flux, and production rates of acetate, formate, lactate, and ethanol. Bioreactor setpoints to maximize production of each product were identified, and all continuous production rates significantly exceed batch rates. Formate spike-ins increased lactate flux and decreased acetate, ethanol, and formate fluxes. The bioreactor and turbidostat culture schemes demonstrated here offer tools to tailor AGF fermentations to application-specific hydrolysate product profiles.

Agriculture↗

Diel Variations in Optical Properties of Micromonas pusilla, a Prasinophyte

A laboratory experiment was conducted on cultures of Micromonas pusilla, a marine prasinophyte, to investigate how cell growth and division affect the optical properties over the light:dark cycle. Measurements were made of cell size and concentration, attenuation and absorption coefficients, flow cytometric light scattering (in forward and side directions), chlorophyll and carbon content. Refractive index was calculated using the anomalous diffraction approximation Cells were about 1.5 micrometers in diameter and exhibited phased division, with the major division burst occurring during the night. Typical diel variations were observed, with cells increasing in size and light scattering during the day as they photosynthesize and decreasing at night upon division. The cells were in ultradian growth, with more than one division per day, at a light level of 120 Mu-mol photons m/sq/sec. Since these cells are similar in size to small phytoplankton that are typically abundant in field samples, these results can be used in the interpretation of diel variations in light scattering in natural populations of phytoplankton.

DuRand, Michele D.↗

Phytoplankton-Fluorescence-Lifetime Vertical Profiler

A battery-operated optoelectronic instrument is designed to be lowered into the ocean to measure the intensity and lifetime of fluorescence of chlorophyll A in marine phytoplankton as a function of depth from 0 to 300 m. Fluorescence lifetimes are especially useful as robust measures of photosynthetic productivity of phytoplankton and of physical and chemical mechanisms that affect photosynthesis. The knowledge of photosynthesis in phytoplankton gained by use of this and related instruments is expected to contribute to understanding of global processes that control the time-varying fluxes of carbon and associated biogenic elements in the ocean. The concentration of chlorophyll in the ocean presents a major detection challenge because in order to obtain accurate values of photosynthetic parameters, the intensity of light used to excite fluorescence must be kept very low so as not to disturb the photosynthetic system. Several innovations in fluorometric instrumentation were made in order to make it possible to reach the required low detection limit. These innovations include a highly efficient optical assembly with an integrated flow-through sample interface, and a high-gain, low-noise electronic detection subsystem. The instrument also incorporates means for self-calibration during operation, and electronic hardware and software for control, acquisition and analysis of data, and communications. The electronic circuitry is highly miniaturized and designed to minimize power demand. The instrument is housed in a package that can withstand the water pressure at the maximum depth of 300 m. A light-emitting diode excites fluorescence in the sample flow cell, which is placed at one focal point of an ellipsoidal reflector. A photomultiplier tube is placed at the other focal point. This optical arrangement enables highly efficient collection of fluorescence emitted over all polar directions. Fluorescence lifetime is measured indirectly, by use of a technique based on the same principle as the one described in "Fluorometer for Analysis of Photosynthesis in Phytoplankton" (SSC-00110), NASA Tech Briefs, Vol. 24, No. 1 (November 2000), page 79. The excitation is modulated at a frequency of 70 MHz, and the phase shift between the excitation light and the emitted fluorescence is measured by a detection method in which the 70 MHz signal is down-converted to a 400 Hz signal. The fluorescence lifetime can be computed from the known relationship among the fluorescence lifetime, phase shift, and modulation frequency

Fernandez, Salvador M.↗

Continuous precipitation‐filtration process for initial capture of a monoclonal antibody product using a four‐stage countercurrent hollow fiber membrane washing step

The significant increase in product titers, coupled with the growing focus on continuous bioprocessing, has renewed interest in using precipitation as a low‐cost alternative to Protein A chromatography for the primary capture of monoclonal antibody (mAb) products. In this work, a commercially relevant mAb was purified from clarified cell culture fluid using a tubular flow precipitation reactor with dewatering and washing provided by tangential flow microfiltration. The particle morphology was evaluated using an inline high‐resolution optical probe, providing quantitative data on the particle size distribution throughout the precipitation process. Data were obtained in both a lab‐built 2‐stage countercurrent washing system and a commercial countercurrent contacting skid that provided 4 stages of continuous washing. The processes were operated continuously for 2 h with overall mAb yield of 92 ± 3% and DNA removal of nearly 3 logs in the 4‐stage system. The high DNA clearance was achieved by selective redissolution of the mAb using a low pH acetate buffer. Host cell protein clearance was 0.59 ± 0.08 logs, comparable to that based on model predictions. The process mass intensity was slightly better than typical Protein A processes and could be significantly improved by preconcentration of the antibody feed material.

59 BASIC BIOLOGICAL SCIENCES↗

High repetition rate mapping of the interaction between a laser plasma and magnetized background plasma via laser induced fluorescence

In this work, the laminar coupling of energy between a laser-produced plasma and a background magnetized plasma was investigated via planar laser induced fluorescence diagnostic and magnetic flux probes. Experiments performed on the Large Plasma Device at the University of California, Los Angeles, mapped out the two-dimensional spatiotemporal evolution of the laser-plasma (debris) ion velocity distribution function (VDF) to assess debris-background coupling in a sub-Alfvénic regime. The acquisition of these data necessitates high repetition rate (1 Hz) as each dataset is the accumulation of thousands of laser shots, which would not be feasible in single-shot experiments. Fully kinetic, three-dimensional particle-in-cell simulations are compared to the measured VDFs to provide a framework in which we can understand the coupling of a sub-Alfvénic plasma flow through a preformed, magnetized plasma. The simulations display the same departure from the expected gyromotion of the debris plasma as observed in the experimental data, and in conjunction with the measured magnetic field traces, have led to the direct observation of the collisionless coupling via laminar fields.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Orbital atomic oxygen effects on thermal control and optical materials - STS-8 results

The effects of exposing 23 specimens of optical and thermal control materials to space at 120 km altitude for over 40 hrs during the STS-8 mission are discussed. Ten samples of paint targeted for the Space Telescope (ST) and the Tethered Satellite were exposed, and included polyurethane, oxide, silicone, and glossy black and white samples which were scanned for alterations in the optical properties after being retrieved. Nine mirror-type materials were also investigated, along with silver specimens typical of solar cell interconnects. The oxygen flow at the orbital altitude was 3.5 x 10 to the 20th atoms/cu cm. The exposures caused no degradation of the magnesium fluoride mirror coatings, while the Kapton coating for the ST solar cell panels showed evidence of losing thickness. The Ag solar cell contacts will require coatings to extend their lifetimes. Overcoatings were also proven necessary for inhibiting degradation of painted surfaces.

Whitaker, A. F.↗

NASA Tech Briefs, April 2002

The contents include: 1) Application Briefs; 2) Sneak Preview of Sensors Expo; 3) The Complexity of the Diagnosis Problem; 4) Design Concepts for the ISS TransHab Module; 5) Characteristics of Supercritical Transitional Mixing Layers; 6) Electrometer for Triboelectric Evaluation of Materials; 7) Infrared CO2 Sensor With Built-In Calibration Chambers; 8) Solid-State Potentiometric CO Sensor; 9) Planetary Rover Absolute Heading Detection Using a Sun Sensor; 10) Concept for Utilizing Full Areas of STJ Photodetector Arrays; 11) Development of Cognitive Sensors; 12) Enabling Higher-Voltage Operation of SOl CMOS Transistors; 13) Estimating Antenna-Pointing Errors From Beam Squints; 14) Advanced-Fatigue-Crack-Growth and Fracture- Mechanics Program; 15) Software for Sequencing Spacecraft Actions; 16) Program Distributes and Tracks Organizational Memoranda; 16) Flat Membrane Device for Dehumidification of Air; 17) Inverted Hindle Mount Reduces Sag of a Large, Precise Mirror; 18) Heart-Pump-Outlet/Cannula Coupling; 19) Externally Triggered Microcapsules Release Drugs In Situ; 20) Combinatorial Drug Design Augmented by Information Theory; 21) Multiple-Path-Length Optical Absorbance Cell; 22) Model of a Fluidized Bed Containing a Mixture of Particles; 23) Refractive Secondary Concentrators for Solar Thermal Systems; 24) Cold Flow Calorimeter; 25) Methodology for Tracking Hazards and Predicting Failures; 26) Estimating Heterodyne-Interferometer Polarization Leakage; 27) An Efficient Algorithm for Propagation of Temporal- Constraint Networks; 28) Software for Continuous Replanning During Execution; 29) Surface-Launched Explorers for Reconnaissance/Scouting; 30) Firmware for a Small Motion-Control Processor; 31) Gear Bearings and Gear-Bearing Transmissions; and 32) Linear Dynamometer With Variable Stroke and Frequency.

Source record↗

NASA Tech Briefs, November 2009

Topics covered include: Cryogenic Chamber for Servo-Hydraulic Materials Testing; Apparatus Measures Thermal Conductance Through a Thin Sample from Cryogenic to Room Temperature; Rover Attitude and Pointing System Simulation Testbed; Desktop Application Program to Simulate Cargo-Air-Drop Tests; Multimodal Friction Ignition Tester; Small-Bolt Torque-Tension Tester; Integrated Spacesuit Audio System Enhances Speech Quality and Reduces Noise; Hardware Implementation of a Bilateral Subtraction Filter; Simple Optoelectronic Feedback in Microwave Oscillators; Small X-Band Oscillator Antennas; Free-Space Optical Interconnect Employing VCSEL Diodes; Discrete Fourier Transform Analysis in a Complex Vector Space; Miniature Scroll Pumps Fabricated by LIGA; Self-Assembling, Flexible, Pre-Ceramic Composite Preforms; Flight-speed Integral Image Analysis Toolkit; Work Coordination Engine; Multi-Mission Automated Task Invocation Subsystem; Autonomously Calibrating a Quadrupole Mass Spectrometer; Determining Spacecraft Reaction Wheel Friction Parameters; Composite Silica Aerogels Opacified with Titania; Multiplexed Colorimetric Solid-Phase Extraction; Detecting Airborne Mercury by Use of Polymer/Carbon Films; Lattice-Matched Semiconductor Layers on Single Crystalline Sapphire Substrate; Pressure-Energized Seal Rings to Better Withstand Flows; Rollerjaw Rock Crusher; Microwave Sterilization and Depyrogenation System; Quantifying Therapeutic and Diagnostic Efficacy in 2D Microvascular Images; NiF2/NaF:CaF2/Ca Solid-State High-Temperature Battery Cells; Critical Coupling Between Optical Fibers and WGM Resonators; Microwave Temperature Profiler Mounted in a Standard Airborne Research Canister; Alternative Determination of Density of the Titan Atmosphere; Solar Rejection Filter for Large Telescopes; Automated CFD for Generation of Airfoil Performance Tables; Progressive Classification Using Support Vector Machines; Active Learning with Irrelevant Examples; A Data Matrix Method for Improving the Quantification of Element Percentages of SEM/EDX Analysis; Deployable Shroud for the International X-Ray Observatory; Improved Model of a Mercury Ring Damper; Optoelectronic pH Meter: Further Details; X-38 Advanced Sublimator; and Solar Simulator Represents the Mars Surface Solar Environment.

Source record↗

Electrophoresis experiment. Experiment MA-014

A continuous free-flow electrophoresis study was conducted during the Apollo-Soyuz Test Project Mission to investigate and evaluate the increase in sample flow rate and sample resolution achievable in space. The electrophoresis equipment was designed for the separation of four mixtures of biological cells with variable sample flow rates, buffer flow rates, and electric field gradients. Separation quality was assessed by measuring the light from a quartz lamp through the electrophoresis channel and onto a photodiode system. The data evaluation indicates that all monitored systems operated correctly during the experiment. The optical system produced a light that was too bright to discern true cell distributions, but final analysis of scientific data by computer processing shows the expected distribution of separated cells.

Hannig, K. H.↗

Molar Absorptivities of U(VI), U(IV), and Pu(III) in Nitric Acid Solutions of Various Concentrations Relevant to Developing Nuclear Fuel Recycling Flowsheets

Testing of a co-decontamination (CoDCon) tributyl phosphate (TBP) based solvent extraction flowsheet is being performed to optimize conditions for achieving a target U/Pu ratio in the Pu-containing product. The flowsheet is designed to directly produce a mixture of U and Pu with a U/Pu mass ratio of 7/3. The system is monitored in real time using optical spectroscopy, which allows for control of the U/Pu ratio in the aqueous U/Pu nitrate product. On-line spectrophotometric monitoring of the aqueous stream at the reductive stripping step involves determination of U(VI), U(IV) and Pu(III) concentrations and relies on molar absorptivities of these species in nitric acid at a number of wavelengths corresponding to their peaks’ maxima. The magnitudes of these molar absorptivities are a sensitive function of nitric acid concentration and have to be determined as precisely as possible using an off-line spectrophotometry under well controlled conditions. This step (called training set acquisition) is typically performed not in a high contamination area of radiological glovebox where flow-through cells and other on-line equipment are installed but in a less aggressive environment of a radiological fume hood with much better control of stock solutions quality, dilution factors, optical absorbance scale calibration, etc. This is followed by the calibration transfer between the off-line instrument and the instrument deployed during extraction and stripping runs. This paper reports values of molar absorptivities of U(VI), U(IV), and Pu(III) in nitric acid solution of 0.5 M to 4 M concentration and compares them with available technical literature data. Results of off-line spectrophotometric analysis of selected aqueous grab samples from one of CoDCon runs show satisfactory agreement with total uranium and plutonium concentrations determined in the same samples by ICP-MS.

Sinkov, Sergey I.↗

An optical quality meter suitable for cryogenic liquids

Construction of instrument to measure ratio of liquid to gas of flowing transparent cryogenic fluid is described. Instrument consists of collimated light source and photoconductive cell. Operation of instrument is described and illustration of equipment is provided.

Hobart, H. F.↗

Electrophoresis experiment, experiment MA-014

A continuous, free flow electrophoresis study was conducted during the Apollo Soyuz Test Project mission to investigate and evaluate the increase in sample flow rate and sample resolution achievable in space. The electrophoresis equipment was designed for the separation of four mixtures of biological cells with variable sample flow rates, buffer flow rates, and electric field gradients. Separation quality was assessed by measuring the light from a quartz lamp through the electrophoresis channel and on to a photodiode system. The preliminary results indicate that all monitored systems operated correctly during the experiment. The optical system produced a light that was too bright to discern true cell distributions, but data were received that show a distribution of separated cells.

Hannig, K.↗

Electrodeposition in microgravity: Ground-based experiments

Electrodeposition was studied at one-hundreth g and compared with bench studies at 1 g. The low gravity was achieved during KC-135 aircraft parobolic flights. Flow in a simple cobalt cell (1 M CoSO4) operating under typical commercial conditions (10 to 20 mA/sq cm and 1 V) was monitored with a Schlieren optical system. Natural convection was absent at one-hundreth g. Quantitative comparisons on a cobalt cell with shielded electrodes using interferometry were carried out. Fringe shift differences indicate greater semi-infinite linear diffusion at 1 g than at one-hundreth g for cobalt. Since a shielded electrode operates under diffusion controlled conditions, no differences between 1 g and one-hundreth g would be expected. Similar comparisons on a shielded electrode copper cell were inconclusive. Bench codeposition experiments using polystyrene neutral buoyancy particles coupled with a shielded electrode cobalt cell were begun. Tracking of 12 micron particles showed no measurable difference between thermal/Brownian motion when the cell was operational or nonoperational. Initial experiments on codeposition quality showed a strong dependence upon cathode surface preparation in a shielded electrode configuration.

Riley, C.↗

Tutorial: The equations of electron emission and their evaluation

Electron emission and transport through and over potential barriers is an essential process requiring modeling and simulation to meet the design needs and characterization of an exceedingly broad range of technologically important devices and processes. The simulation and description of thermal, field, and photoemission, and the related concerns of space–charge affected electron flow, often make use of specialized formulations developed in the early days of quantum mechanics. Advancements in the utilization of electron sources and particularly the simulation of devices and applications using advanced particle-in-cell and trajectory methods for beam optics codes create a strong need for a pedagogical account of the emission models to ensure correct numerical evaluation of their equations. This Tutorial starts from simple phenomenological accounts and progressively builds to comprehensive models emphasizing straightforward and often rapid calculation. It recommends formulations to supplant the canonical Richardson–Laue–Dushman (thermal), Fowler–Nordheim (field), Fowler–DuBridge (photo), and Baroody (secondary) equations and provides a useful formulation of space–charge affected flow commonly described by the Child–Langmuir relation that takes into account cathode dependence on surface field.

Physics↗

Jet production in super-Eddington accretion disks

A two-dimensional, radiation-coupled, Newtonian hydrodynamic simulation is reported for a super-Eddington, mass accretion rate, M = 4 M(E) disk accretion flow onto a 3-solar mass pseudoblack hole. Near the disk midplane, convection cells effectively block the accretion flow, even though viscous heating maximizes there. Accretion predominantly occurs in a supersonic inflow which follows streamlines of approximately constant angular momentum. The optically thick inflow traps radiation so that 80 percent of the luminosity is absorbed by the black hole; the emergent power is sub-Eddington. An axial jet self consistently forms just outside a conical photosphere which bounds the accretion zone; radiation pressure accelerates the jet to about 10 to the 10th cm/s. The jet's mass efflux is only 0.4 percent of the total mass accretion rate.

Eggum, G. E.↗

HO2 detection by near infrared absorption using tunable diode lasers

The strongest absorption lines are in the v sub 2 vibrational band around 1400/cm; several near-coincident line pairs in this region provide max linestrengths of 1.2 x 10 exp -20 sq. cm/(molecule*cm). High Frequency wavelength modulation coupled with sweep integration were used to minimize noise and maintain spectral discrimination. Reduced pressure sampling was performed using supersonic nozzle and an aerodynamic flow cell to minimize residence time and wall losses of radicals. The astigmatic mirror design provides pathlengths up to 200 m in volume of 3 liters with minimal optical interference fringes; longer pathlengths are possible. The detection limit depends on pathlength and minimum fractional absorptions.

Nelson, David↗

Laser-Plasma Spatiotemporal Cyanide Spectroscopy and Applications

This article reports new measurements of laser-induced plasma hypersonic expansion measurements of diatomic molecular cyanide (CN). Focused, high-peak-power 1064 nm Q-switched radiation of the order of 1 TW/cm 2 generated optical breakdown plasma in a cell containing a 1:1 molar gas mixture of N 2 and CO 2 at a fixed pressure of 1.1 × 10 5 Pascal and in a 100 mL/min flow of the mixture. Line-of-sight (LOS) analysis of recorded molecular spectra indicated the outgoing shockwave at expansion speeds well in excess of Mach 5. Spectra of atomic carbon confirmed increased electron density near the shockwave, and, equally, molecular CN spectra revealed higher excitation temperature near the shockwave. Results were consistent with corresponding high-speed shadowgraphs obtained by visualization with an effective shutter speed of 5 nanoseconds. In addition, LOS analysis and the application of integral inversion techniques allow inferences about the spatiotemporal plasma distribution.

36 MATERIALS SCIENCE↗

Spectroscopic chemical analysis methods and apparatus

Spectroscopic chemical analysis methods and apparatus are disclosed which employ deep ultraviolet (e.g. in the 200 nm to 300 nm spectral range) electron beam pumped wide bandgap semiconductor lasers, incoherent wide bandgap semiconductor light emitting devices, and hollow cathode metal ion lasers to perform non-contact, non-invasive detection of unknown chemical analytes. These deep ultraviolet sources enable dramatic size, weight and power consumption reductions of chemical analysis instruments. Chemical analysis instruments employed in some embodiments include capillary and gel plane electrophoresis, capillary electrochromatography, high performance liquid chromatography, flow cytometry, flow cells for liquids and aerosols, and surface detection instruments. In some embodiments, Raman spectroscopic detection methods and apparatus use ultra-narrow-band angle tuning filters, acousto-optic tuning filters, and temperature tuned filters to enable ultra-miniature analyzers for chemical identification. In some embodiments Raman analysis is conducted simultaneously with native fluorescence spectroscopy to provide high levels of sensitivity and specificity in the same instrument.

Hug, William F.↗