Search NASA⌕ Search

SEARCH · Search NASA

Results for “patterned electrode”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Electrodynamic Dust Shield for Lunar/ISS Experiment Project

The Electrostatics and Surface Physics Laboratory at Kennedy Space Center is developing a dust mitigation experiment and testing it on the lunar surface and on the International Space Station (ISS). The Electrodynamic Dust Shield (EDS) clears dust off surfaces and prevents accumulation by using a pattern of electrodes to generate a non-uniform electric field over the surface being protected. The EDS experiment will repel dust off materials such as painted Kapton and glass to demonstrate applications for thermal radiators, camera lenses, solar panels, and other hardware and equipment.

Zeitlin, Nancy↗

Surface Acoustic Wave H2 and O2 Sensors Based on Conducting Metal Oxides/Langasite for Elevated Temperature Applications - presentation

<p style="text-align: justify;"><span style="font-family: Arial; font-size: 10pt;">• </span><span style="color: black; font-family: Arial; font-size: 10pt;">SAW reflective delay line devices were designed and successfully fabricated on Langasite by patterning platinum electrodes.</span><p style="text-align: justify;"><span style="font-family: Arial; font-size: 10pt;">• </span><span style="color: black; font-family: Arial; font-size: 10pt;">Fabricated devices successfully tested up to 500°C for temperature sensing applications.</span><p style="text-align: justify;"><span style="font-family: Arial; font-size: 10pt;">• </span><span style="color: black; font-family: Arial; font-size: 10pt;">Indium oxide (IO) and indium tin oxide (ITO) sensing layers were developed on the SAW devices using sputtering and sol-gel method.</span><p style="text-align: justify;"><span style="font-family: Arial; font-size: 10pt;">• </span><span style="color: black; font-family: Arial; font-size: 10pt;">IO- and ITO-functionalized langasite SAW reflective delay line devices were used for sensing H2 and O2 at 350°C. </span><br>

Mao, Elizabeth↗

A simple, validated approach for design of two-dimensional periodic particle patterns via acoustophoresis

Two-dimensional patterning of microparticles enables a wide range of functional materials, including patterned energy storage electrodes, flexible electronics, and sensor arrays. Particle patterning via acoustics offers an attractive path to generate a wide variety of 2D periodic patterns that introduce tailorable hierarchical porosity, useful for controlling surface area, transport distances, and other properties. This method is most effective with micron scale particles and patterns of tens to hundreds of microns. To enable systematic exploration of the broad design space for such patterns, this work develops a model of 2D and 3D assembly of particles at high loadings and validates the obtained patterns against both experiments and more computationally intensive modeling techniques. Using this simple model, connections are mapped between input parameters (like actuation conditions, particle volume fraction, material properties) and output geometrical features (like void size and shape, pattern connectivity, and surface area) so that they can be tailored to given applications. The utility of this simple model is illustrated by predicting and then experimentally demonstrating new hierarchical patterns resulting from multiple waves of different frequencies interacting. These multiscale patterns offer the potential to lift the limits on surface area, diffusion distances, and other features.

42 ENGINEERING↗

Copper Electrode on Flexible Substrate by Intense Pulsed Light Sintering of Microsized Copper Particles

Metal electrodes deposited in a grid pattern onto flexible polymer substrates have been shown to be a viable alternative to replace indium tin oxide (ITO) as the transparent anode for organic photovoltaics. copper may be a better alternative in terms of cost and stability for large area low-cost solar modules, specifically on roll-to-roll platforms. These customized electrode patterns can be fabricated from copper nanoparticles through various printing techniques applicable to solution phase processing. The Intense Pulsed Light (IPL) technique has been used to sinter copper nanoparticles (~100nm) to fabricate conductive copper electrodes on flexible polymer substrates. However, compared to nanosized (~100 nm) copper particles, microsized (~2 um) copper is much cheaper. In this work, microsized (~2 um) copper is used to produce high conductive copper inks. The conductivity of the print can be adjusted through the use of surfactant. IPL sintering was optimized to obtain high conductivity copper films. In conclusion, several microscopic and electrical spectroscopic characterization techniques such as scanning electron microscopy (SEM), x-ray diffraction (XRD), 4-point probe resistivity measurements were employed to characterize the copper electrodes.

14 SOLAR ENERGY↗

Wideband Single-Crystal Transducer for Bone Characterization

The microgravity conditions of space travel result in unique physiological demands on the human body. In particular, the absence of the continual mechanical stresses on the skeletal system that are present on Earth cause the bones to decalcify. Trabecular structure decreases in thickness and increases in spacing, resulting in decreased bone strength and increased risk of injury. Thus, monitoring bone health is a high priority for long-term space travel. A single probe covering all frequency bands of interest would be ideal for such measurements, and this would also minimize storage space and eliminate the complexity of integrating multiple probes. This invention is an ultrasound transducer for the structural characterization of bone. Such characterization measures features of reflected and transmitted ultrasound signals, and correlates these signals with bone structure metrics such as bone mineral density, trabecular spacing, and thickness, etc. The techniques used to determine these various metrics require measurements over a broad range of ultrasound frequencies, and therefore, complete characterization requires the use of several narrowband transducers. This is a single transducer capable of making these measurements in all the required frequency bands. The device achieves this capability through a unique combination of a broadband piezoelectric material; a design incorporating multiple resonator sizes with distinct, overlapping frequency spectra; and a micromachining process for producing the multiple-resonator pattern with common electrode surfaces between the resonators. This device consists of a pattern of resonator bars with common electrodes that is wrapped around a central mandrel such that the radiating faces of the resonators are coplanar and can be simultaneously applied to the sample to be measured. The device operates as both a source and receiver of acoustic energy. It is operated by connection to an electronic system capable of both providing an excitation signal to the transducer and amplifying the signal received from the transducer. The excitation signal may be either a wide-bandwidth signal to excite the transducer across its entire operational spectrum, or a narrow-bandwidth signal optimized for a particular measurement technique. The transducer face is applied to the skin covering the bone to be characterized, and may be operated in through-transmission mode using two transducers, or in pulse-echo mode. The transducer is a unique combination of material, design, and fabrication technique. It is based on single-crystal lead magnesium niobate lead titanate (PMN-PT) piezoelectric material. As compared to the commonly used piezoceramics, this piezocrystal has superior piezoelectric and elastic properties, which results in devices with superior bandwidth, source level, and power requirements. This design necessitates a single resonant frequency. However, by operating in a transverse length-extensional mode, with the electric field applied orthogonally to the extensional direction, resonators of different sizes can share common electrodes, resulting in a multiply-resonant structure. With carefully sized resonators, and the superior bandwidth of piezocrystal, the resonances can be made to overlap to form a smooth, wide-bandwidth characteristic.

Liang, Yu↗

Wideband Single-Crystal Transducer for Bone Characterization

The microgravity conditions of space travel result in unique physiological demands on the human body. In particular, the absence of the continual mechanical stresses on the skeletal system that are present on Earth cause the bones to decalcify. Trabecular structure decreases in thickness and increases in spacing, resulting in decreased bone strength and increased risk of injury. Thus, monitoring bone health is a high priority for long-term space travel. A single probe covering all frequency bands of interest would be ideal for such measurements, and this would also minimize storage space and eliminate the complexity of integrating multiple probes. This invention is an ultrasound transducer for the structural characterization of bone. Such characterization measures features of reflected and transmitted ultrasound signals, and correlates these signals with bone structure metrics such as bone mineral density, trabecular spacing, and thickness, etc. The techniques used to determine these various metrics require measurements over a broad range of ultrasound frequencies, and therefore, complete characterization requires the use of several narrowband transducers. This is a single transducer capable of making these measurements in all the required frequency bands. The device achieves this capability through a unique combination of a broadband piezoelectric material; a design incorporating multiple resonator sizes with distinct, overlapping frequency spectra; and a micromachining process for producing the multiple-resonator pattern with common electrode surfaces between the resonators. This device consists of a pattern of resonator bars with common electrodes that is wrapped around a central mandrel such that the radiating faces of the resonators are coplanar and can be simultaneously applied to the sample to be measured. The device operates as both a source and receiver of acoustic energy. It is operated by connection to an electronic system capable of both providing an excitation signal to the transducer and amplifying the signal received from the transducer. The excitation signal may be either a wide-bandwidth signal to excite the transducer across its entire operational spectrum, or a narrow-bandwidth signal optimized for a particular measurement technique. The transducer face is applied to the skin covering the bone to be characterized, and may be operated in through transmission mode using two transducers, or in pulse-echo mode.

Liang, Yu↗

Solution-Deposited and Patternable Conductive Polymer Thin-Film Electrodes for Microbial Bioelectronics

Microbial bioelectronic devices integrate naturally occurring or synthetically engineered electroactive microbes with microelectronics. These devices have a broad range of potential applications, but engineering the biotic–abiotic interface for biocompatibility, adhesion, electron transfer, and maximum surface area remains a challenge. Prior approaches to interface modification lack simple processability, the ability to pattern the materials, and/or a significant enhancement in currents. We report a novel conductive polymer coating that significantly enhances current densities relative to unmodified electrodes in microbial bioelectronics is reported. The coating is based on a blend of poly(3,4-ethylenedioxythiophene)-poly(styrenesulfonate) (PEDOT:PSS) crosslinked with poly(2-hydroxyethylacrylate) (PHEA) along with a thin polydopamine (PDA) layer for adhesion to an underlying indium tin oxide (ITO) electrode. When used as an interface layer with the current-producing bacterium Shewanella oneidensis MR-1, this material produces a 178-fold increase in the current density compared to unmodified electrodes, a current gain that is higher than previously reported thin-film 2D coatings and 3D conductive polymer coatings. The chemistry, morphology, and electronic properties of the coatings are characterized and the implementation of these coated electrodes for use in microbial fuel cells, multiplexed bioelectronic devices, and organic electrochemical transistor based microbial sensors are demonstrated. It is envisioned that this simple coating will advance the development of microbial bioelectronic devices.

patterned bioelectronics↗

The Effect of Surface Induced Flows on Bubble and Particle Aggregation

Almost 20 years have elapsed since a phenomenon called "radial specific coalescence" was identified. During studies of electrolytic oxygen evolution from the back side of a vertically oriented, transparent tin oxide electrode in alkaline electrolyte, one of the authors (Sides) observed that large "collector" bubbles appeared to attract smaller bubbles. The bubbles moved parallel to the surface of the electrode, while the electric field was normal to the electrode surface. The phenomenon was reported but not explained. More recently self ordering of latex particles was observed during electrophoretic deposition at low DC voltages likewise on a transparent tin oxide electrode. As in the bubble work, the field was normal to the electrode while the particles moved parallel to it. Fluid convection caused by surface induced flows (SIF) can explain these two apparently different experimental observations: the aggregation of particles on an electrode during electrophoretic deposition, and a radial bubble coalescence pattern on an electrode during electrolytic gas evolution. An externally imposed driving force (the gradient of electrical potential or temperature), interacting with the surface of particles or bubbles very near a planar conducting surface, drives the convection of fluid that causes particles and bubbles to approach each other on the electrode.

Guelcher, Scott A.↗

Method of Fabricating a Piezoelectric Composite Apparatus

A method for fabricating a piezoelectric macro-fiber composite actuator comprises providing a piezoelectric material that has two sides and attaching one side upon an adhesive backing sheet. The method further comprises slicing the piezoelectric material to provide a plurality of piezoelectric fibers in juxtaposition. A conductive film is then adhesively bonded to the other side of the piezoelectric material, and the adhesive backing sheet is removed. The conductive film has first and second conductive patterns formed thereon which are electrically isolated from one another and in electrical contact with the piezoelectric material. The first and second conductive patterns of the conductive film each have a plurality of electrodes to form a pattern of interdigitated electrodes. A second film is then bonded to the other side of the piezoelectric material. The second film may have a pair of conductive patterns similar to the conductive patterns of the first film.

Wilkie, W. Keats↗

Patterning of Indium Tin Oxide Films

A relatively rapid, economical process has been devised for patterning a thin film of indium tin oxide (ITO) that has been deposited on a polyester film. ITO is a transparent, electrically conductive substance made from a mixture of indium oxide and tin oxide that is commonly used in touch panels, liquid-crystal and plasma display devices, gas sensors, and solar photovoltaic panels. In a typical application, the ITO film must be patterned to form electrodes, current collectors, and the like. Heretofore it has been common practice to pattern an ITO film by means of either a laser ablation process or a photolithography/etching process. The laser ablation process includes the use of expensive equipment to precisely position and focus a laser. The photolithography/etching process is time-consuming. The present process is a variant of the direct toner process an inexpensive but often highly effective process for patterning conductors for printed circuits. Relative to a conventional photolithography/ etching process, this process is simpler, takes less time, and is less expensive. This process involves equipment that costs less than $500 (at 2005 prices) and enables patterning of an ITO film in a process time of less than about a half hour.

Immer, Christopher↗

Fabrication of Microshutter Arrays for James Webb Space Telescope

Two-dimensional MEMS microshutter arrays are being developed at NASA Goddard Space Flight Center for use in the near-infrared region on the Next Generation Space Telescope (NGST). The microshutter arrays are designed for the selective transmission of light with high efficiency and high contrast. The NGST environment requires cryogenic operation at 45K. Microshutter arrays are fabricated out of silicon-oxide-insulated (SOI) silicon wafers. Arrays are close-packed silicon nitride membranes with a pixel size of 100x100 microns. Individual shutters are patterned with a torsion flexure permitting shutters to open 90 degrees with a minimized mechanical stress concentration. The mechanical shutter arrays are fabricated using MEMS technologies. The processing includes a multi-layer metal deposition and patterning of shutter electrodes and magnetic pads, reactive ion etching (RE) of the front side to form shutters out of the nitride membrane, an anisotropic back-etch for wafer thinning, followed by a deep RIE (DRIE) back-etch down to the nitride shutter membrane to form frames and relieve shutters from the silicon substrate. An additional metal deposition and patterning is used to form back electrodes. Shutters are actuated using a magnetic force and latched using an electrostatic force.

Li, Mary J.↗

Microshutter Arrays for James Webb Space Telescope

Two-dimensional MEMS microshutter arrays are being developed at NASA Goddard Space Flight Center for use in the near-infrared region on the James Webb Space Telescope (JWST). The microshutter arrays are designed for the selective transmission of light with high efficiency and high contrast. The JWST environment requires cryogenic operation at 35K. Microshutter arrays are fabricated out of silicon-oxide-insulated (SOI) silicon wafers. Arrays are close-packed silicon nitride membranes with a pixel size of 100x200 p. Individual shutters are patterned with a torsion flexure permitting shutters to open 90 degrees with a minimized mechanical stress concentration. The mechanical shutter arrays are fabricated using MEMS technologies. The processing includes a multi- layer metal deposition and patterning of shutter electrodes and magnetic pads, reactive ion etching (NE) of the front side to form shutters out of the nitride membrane, an anisotropic back-etch for wafer thinning, followed by a deep RIE (DRIE) back-etch down to the nitride shutter membrane to form W e s and relieve shutters from the silicon substrate. An additional metal deposition and patterning is used to form back electrodes. Shutters are actuated using a magnetic force and latched using an electrostatic force. . . . KEYWORDS: microshutter, MEMS, RIE, DRIE, micro-optics, near inbred, space telescope

Li, Mary J.↗

Deep-Learning-Enabled Crack Detection and Analysis in Commercial Lithium-Ion Battery Cathodes

We report in Li-ion batteries, the mechanical degradation initiated by micro cracks is one of the bottlenecks for enhancing the performance. Quantifying the crack formation and evolution in complex composite electrodes can provide important insights into electrochemical behaviors under prolonged and/or aggressive cycling. However, observation and interpretation of the complicated crack patterns in battery electrodes through imaging experiments are often time-consuming, labor intensive, and subjective. Herein, a deep learning-based approach is developed to extract the crack patterns from nanoscale hard X-ray holo-tomography data of a commercial 18650-type battery cathode. Efficient and effective quantification of the damage heterogeneity with automation and statistical significance is demonstrated. The crack characteristics are further associated with the active particles’ packing densities and a potentially viable architectural design is discussed for suppressing the structural degradation in an industry-relevant battery configuration.

25 ENERGY STORAGE↗

Solar cell having improved back surface reflector

The operating temperature is reduced and the output of a solar cell is increased by using a solar cell which carries electrodes in a grid finger pattern on its back surface. These electrodes are sintered at the proper temperature to provide good ohmic contact. After sintering, a reflective material is deposited on the back surface by vacuum evaporation. Thus, the application of the back surface reflector is separate from the back contact formation. Back surface reflectors formed in conjunction with separate grid finger configuration back contacts are more effective than those formed by full back metallization of the reflector material.

Chai, A. T.↗

In Situ Raman Mapping of Si Island Electrodes and Stress Modeling as a Function of Lithiation and Size

Si is known for cracking and delamination during electrochemical cycling of a battery due to the large volume change associated with Li insertion and extraction. However, it has been found experimentally that patterned Si island electrodes that are 200 nm thick and less than 7 μm wide can deform in a purely elastic manner. Inspired by this, we performed in situ Raman stress characterization of model poly-crystalline Si island electrodes using an electrochemical cell coupled with an immersion objective lens and designed for a short working distance. A 5 μm wide Si island electrode showed a parabolic stress profile during lithiation, while for a 15 μm Si island electrode, a stress plateau in the center of the electrode was observed. A continuum model with coupled electro-chemo-mechanical (ECM) physics was established to understand the stress measurement. A qualitative agreement was reached between modeling and experimental data, and the critical size effect could be explained by the Li diffusive flux as governed by competition between the Li concentration and hydrostatic stress gradients. Below the critical size, the stress gradient drives Li toward the edges, where the electrode volume is free to expand, while above the critical size, the stress plateau inhibits Li diffusion to the edge and forces destructive stress relief by cracking. Furthermore, this work represents a promising methodology for in situ characterization of ECM coupling in battery electrodes, with suggestions provided for further improvement.

25 ENERGY STORAGE↗

STRUCTURAL STABILITY OF MAGNETIC TUNNEL JUNCTION BASED MOLECULAR SPINTRONICS DEVICES (MTJMSD)

Harnessing the exotic properties of molecular level nanostructures to produce novel sensors, metamaterials, and futuristic computer devices can be technologically transformative. In addition, connecting the molecular nanostructures to ferromagnetic electrodes bring the unprecedented opportunity of making spin property based molecular devices. We have demonstrated that magnetic tunnel junction based molecular spintronics device (MTJMSD) approach to address numerous technological hurdles that have been inhibiting this field for decades. MTJMSD approach is based on producing a capacitor like a testbed where two metal electrodes are separated by an ultrathin insulator and subsequently bridging the molecule nanostructure across the insulator to transform a capacitor into a molecular device. Our prior work showed that MTJMSDs produced extremely intriguing phenomenon such as room temperature current suppression by six orders, spin photovoltaic effect, and evolution of new forms of magnetic metamaterials arising due to the interaction of the magnetic a molecule with two ferromagnetic thin films. However, making robust and reproducible electrical connections with exotic molecules with ferromagnetic electrodes is full of challenges and requires attention to MTJMSD structural stability. This paper focuses on MTJMSD stability by describing the overall fabrication protocol and the associated potential threat to reliability. MTJMSD is based on microfabrication methods such as (a) photolithography for patterning the ferromagnetic electrodes, (b) sputtering of metallic thin films and insulator, and (c) at the end electrochemical process for bridging the molecules between two ferromagnetic films separated by ~ 2nm insulating gap.

36 MATERIALS SCIENCE↗

Electrostatic Screen for Transport of Martian and Lunar Regolith

The Martian and Lunar Regolith contain fine particulate including those in the size range from 0.5 to 200 micron [1-2]. Martian dust can be transported and deposited by Aeolian processes, including "Dust Devils". Due to the ultra high vacuum (10e-12 Torr), transport of dust on the Moon is solely a result of collision/ballistic motion. Dust obscuration of solar cells is one of the primary factors limiting the duration of Martian missions, including the Mars Exploration Rovers. Dust contamination in vacuum seals is one of the primarily factors that limited lunar excursions during the Apollo missions. Controlled transportation of dust on Mars and the Moon is important for many reasons, including both contamination mitigation and in situ resource utilization (ISRU). Since both the monopole and dipole electrostatic moments result in non-trivial forces on particles in an electrostatic field, dust particles, whether charged or not, can be transported by electrostatic fields. In the electrostatic screen, alternating waveforms of voltage applied to patterned grids of electrodes will transport dust. The authors will show that the canonical methods for transporting dust via electrostatic screen can be readily applied to transport of Martian and Lunar regolith. Experiments have been performed in ambient, low humidity, Martian, and Lunar conditions. Screen parameters have been examined for application to each regolith, such as grid spacing, trace width, grid voltage, pulse pattern, pulse frequency, and coating type. The authors have also developed an electrostatic screen based on optically transparent conductors that can be placed over solar arrays, windows, visors, lenses, etc.

Immer, C.↗

Piezoelectric Resonator with Two Layers

A piezoelectric resonator device includes: a top electrode layer with a patterned structure, a top piezoelectric layer adjacent to the top layer, a middle metal layer adjacent to the top piezoelectric layer opposite the top layer, a bottom piezoelectric layer adjacent to the middle layer opposite the top piezoelectric layer, and a bottom electrode layer with a patterned structure and adjacent to the bottom piezoelectric layer opposite the middle layer. The top layer includes a first plurality of electrodes inter-digitated with a second plurality of electrodes. A first one of the electrodes in the top layer and a first one of the electrodes in the bottom layer are coupled to a first contact, and a second one of the electrodes in the top layer and a second one of the electrodes in the bottom layer are coupled to a second contact.

Stephanou, Philip J.↗