Search NASA⌕ Search

SEARCH · Search NASA

Results for “peak load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Estimating the impact of tariff-driven behind-the-meter storage operation on distribution grid investments

Increasing growth of distributed solar photovoltaics (PV) and electric vehicles (EV) can strain local distribution networks and require costly upgrades. Distributed battery storage, often deployed alongside PV, can be used to mitigate those costs, depending on how batteries are operated. This study evaluates the potential deferral value of distributed battery storage across a range of tariff structures, focusing on the rate structures most commonly available to residential customers today and related variants. Deferrals are evaluated with a least-cost distribution grid expansion optimization model to identify requirements on line reconductoring, transformer upgrades, and voltage regulator installations under each tariff. Results show that TOU rates and net billing tariffs can yield meaningful deferral value, depending on specific tariff structure features. Under the best performing tariff structure tested, storage produced a median annualized deferral value of $7.18 per kW of storage capacity ( kW S ) across all feeders in the sample, though deferral values were considerably larger for feeders with peak loads that coincide with utility system peak, i.e., timing of TOU peak period. In contrast, under an unrestricted TOU design with no restrictions on grid charging or discharging, the median deferral value was $0/ kW S illustrating the critical importance of tariff structure details.

Rodriguez-Garcia, Luis↗

Initial guidelines and estimates for a power system with inertial (flywheel) energy storage

The starting point for the assessment of a spacecraft power system utilizing inertial (flywheel) energy storage. Both general and specific guidelines are defined for the assessment of a modular flywheel system, operationally similar to but with significantly greater capability than the multimission modular spacecraft (MMS) power system. Goals for the flywheel system are defined in terms of efficiently train estimates and mass estimates for the system components. The inertial storage power system uses a 5 kw-hr flywheel storage component at 50 percent depth of discharge (DOD). It is capable of supporting an average load of 3 kw, including a peak load of 7.5 kw for 10 percent of the duty cycle, in low earth orbit operation. The specific power goal for the system is 10 w/kg, consisting of a 56w/kg (end of life) solar array, a 21.7 w-hr/kg (at 50 percent DOD) flywheel, and 43 w/kg power processing (conditioning, control and distribution).

Slifer, L. W., Jr.↗

Scalability of Cohesive Fatigue Analyses Using Explicit Solvers

A cohesive fatigue law has been integrated into a constitutive material model compatible with an explicit finite element solver. The cohesive fatigue model response is based on engineering approximations of the endurance limit and the Goodman diagram. This approach can predict stress-life diagrams for crack initiation, the Paris law regime, and transient effects of crack initiation and stable tearing. Simplified cyclic loading is utilized so that the applied load(or displacement) corresponds to the peak load of a fatigue cycle. Loads are held constant during fatigue while damage develops with increasing solution increments. An automatically-calculated ratio of fatigue cycles per solution increment controls the rate of damage growth, ensuring that damage growth is modeled with a sufficient minimum number of increments and damage growth advances to a minimum desired extent within the explicit analysis step time. The compatibility with an explicit finite element solver enables the analysis of structures that are computationally intractable for implicit finite element solvers. Scalability studies are conducted for geometrically nonlinear problems involving fiber-reinforced composite structures that exhibit fatigue damage growth of interacting matrix cracks and delaminations

Frank A Leone↗

Mechanisms of compressive failure in woven composites and stitched laminates

Stitched laminates and angle interlock woven composites have been studied in uniaxial, in-plane, monotonic compression. Failure mechanisms have been found to depend strongly on both the reinforcement architecture and the degree of constraint imposed by the loading grips. Stitched laminates show higher compressive strength, but are brittle, possessing no load bearing capacity beyond the strain for peak load. Post-mortem inspection shows a localized shear band of buckled and broken fibers, which is evidently the product of an unstably propagating kink band. Similar shear bands are found in the woven composites if the constraint of lateral displacements is weak; but, under strong constraint, damage is not localized but distributed throughout the gauge section. While the woven composites tested are weaker than the stitched laminates, they continue to bear significant loads to compressive strains of approx. 15 percent, even when most damage is confined to a shear band.

Cox, B. N.↗

Design and Testing of an Active Heat Rejection Radiator with Digital Turn-Down Capability

NASA's proposed lunar lander, Altair, will be exposed to vastly different external environment temperatures. The challenges to the active thermal control system (ATCS) are compounded by unfavorable transients in the internal waste heat dissipation profile: the lowest heat load occurs in the coldest environment while peak loads coincide with the warmest environment. The current baseline for this fluid is a 50/50 inhibited propylene glycol/water mixture with a freeze temperature around -35 C. While the overall size of the radiator's heat rejection area is dictated by the worst case hot scenario, a turn-down feature is necessary to tolerate the worst case cold scenario. A radiator with digital turn-down capability is being designed as a robust means to maintain cabin environment and equipment temperatures while minimizing mass and power consumption. It utilizes active valving to isolate and render ineffective any number of parallel flow tubes which span across the ATCS radiator. Several options were assessed in a trade-study to accommodate flow tube isolation and how to deal with the stagnant fluid that would otherwise remain in the tube. Bread-board environmental tests were conducted for options to drain the fluid from a turned-down leg as well an option to allow a leg to freeze/thaw. Each drain option involved a positive displacement gear pump with different methods of providing a pressure head to feed it. Test results showed that a start-up heater used to generate vapor at the tube inlet held the most promise for tube evacuation. Based on these test results and conclusions drawn from the trade-study, a full-scale radiator design is being worked for the Altair mission profile.

Sunada, Eric↗

Optimal Electric Vehicle Charging and Discharging Strategies Under DER Compensation Programs: Preprint

The adoption of electric vehicles (EVs) is becoming increasingly popular because of environmental concerns, the greater availability of models, and increased cost-competitiveness with gas vehicles. Because EVs have both charging and discharging capabilities, they provide great potential to help electric utilities with grid operation. When the grid demand is high, EVs can discharge to the grid to reduce the peak load, and vice versa; therefore, electric utilities have designed different policies to encourage EV charging station operators to charge or discharge at certain time periods. The New York State Public Service Commission established the Value of Distributed Energy Resources (VDER), or the Value Stack, to compensate for energy created by distributed energy resources, including EVs. This paper presents an optimization-based approach to identify the "golden hours" and "golden spots," i.e., the effective time periods and geographic locations for EV charging station operators to charge or discharge under the VDER program that can provide them the highest benefit. The proposed methodology can be applied to other compensation mechanisms and distribution systems as well. By working with industry partner NineDot Energy, realistic charging station information is used in this study, and the proposed approach is tested on a distribution feeder. The results from this study can help electric utilities and EV charging station operators determine the ideal charging/discharging time and the ideal locations for the charging station(s) in their distribution systems to achieve maximized benefit.

electric vehicle↗

Demand Response in Residential Energy Code: Technical Brief

As buildings account for over 75% of U.S. electricity use, effectively managing their loads can greatly facilitate the transition towards a clean, reliable grid. Grid-interactive efficient buildings (GEBs) combine efficiency and demand flexibility with smart technologies and communication to provide occupant comfort and productivity while serving the grid as a distributed energy resource (DER). In turn, GEBs can play a key role in ensuring access to an affordable, reliable, sustainable, and modern U.S. electric power system. Their national adoption could provide $\$$100-200 billion in U.S. electric power system cost savings over the next two decades. The associated reduction in CO 2 emissions is estimated at 6% per year by 2030 (DOE 2021). Building codes represent standard design practice in the construction industry and continually evolve to include advanced technologies and innovative practices. Historically, national model energy codes establish minimum efficiency requirements for new construction (ICC 2020). Expanding codes to support GEB capabilities is a pivotal step towards realizing demand flexibility in support of a clean grid by addressing capabilities to improve interoperability between smart building systems, the grid, and renewable energy resources. Realizing GEBs requires buildings with automated demand response (DR) capabilities that enable standardized communication with or control of, subject to explicit consumer consent, energy smart appliances or home energy management systems. This is achieved through direct or indirect (i.e., via an aggregator) communication between appliances and the electric grid. Energy codes can also support DR communication standardization and advance the deployment of building-integrated DERs such as energy storage, generation, and electric vehicles (EVs). Incorporating automated DR capabilities in energy codes provides many benefits to the consumers. Specifically, it aligns building electric load demand with intermittent renewable energy source availability, decreases peak load on the electric grid, allows buildings to respond to utility price signals, supports electrical network reliability and market growth of products and processes aligned with clean economic growth. The incorporation of DR into the model residential energy codes was considered for both the 2021 and 2024 International Energy Conservation Code (IECC) code development cycles. The approved DR measures in the 2021 cycle were removed in response to appeals (ICC 2020). Updated language was presented for consideration again for the 2024 IECC, where it was negotiated and again approved, and again removed in response to appeals (ICC 2024). This resulted in many sections, including sections on demand responsive controls, being moved to the credits options or an appendix as a voluntary application. This technical brief updates the proposed DR components such that they can be considered by states and local governments for direct incorporation into their codes, as well as for future IECC energy code development. The proposal refinements are intended to support consistency in approach and provide a degree of certainty for building owners, designers, contractors, manufacturers, and building and fire safety professionals. The scope of this technical brief includes three strategies for DR in residential buildings: 1) smart thermostats with demand-responsive control, 2) electric water heating incorporating demand-responsive controls and communication and 3) grid Integrated solar and energy storage systems.

2021 IECC↗

Deformation and damage of composite laminates under impact loading

An analysis was conducted of quasi-isotropic graphite/epoxy plates 8-ply and 16-ply thick clamped around a circumference, subjected to central impact loading. The imparted energy, load history, and transient strains at various locations through the thickness were obtained. The dynamic load history for the thin laminate demonstrates a higher peak load of shorter duration than for the thick laminate, whereas the load record for the thick laminate shows more pronounced fluctuations than for the thin laminate, related to more extensive damage development and flexural oscillations in the former.

Daniel, I. M.↗

Comparison Testing and Analysis of Braided Cords Constructed from Varying Kevlar Fiber Types

Material advancements move quickly, resulting in material obsolescence issues that require parachute engineers to understand how the material properties change with a material upgrade and if there are expected impacts to overall performance of the parachute. The objective of this test was to measure the elongation of different Kevlar types at both the cord-level and at the yarn-level to determine if a change in Kevlar type impacted parachute performance. An Instron machine with a pin-to-pin connection was used to measure load and displacement time histories for various Kevlar cord and yarn samples in a cyclic load profile. Twenty-four cord samples and twenty-four yarn samples were tested; each sample was cycled five times to the relevant maximum load (either to breaking strength or to the 30% peak load expected in flight). In addition to the Instron measurements, a photogrammetric technique was also implemented to measure elongation of the samples using button targets. Modulus test data shows approximately a 10% difference in elongation between Kevlar 29AP and Kevlar 129, and another 10% difference in elongation between Kevlar 29 and Kevlar 29AP. Although this is a measurable change in modulus, the effect on parachute performance is likely small, particularly for non-primary structure elements of relatively small length. This test campaign provides an example of the type of testing and analysis that parachute engineers could do to understand how material upgrades affect performance of their systems.

Parachutes↗

Comparison Testing and Analysis of Braided Cords Constructed from Varying Kevlar Fiber Types

Material advancements move quickly, resulting in material obsolescence issues that require parachute engineers to understand how the material properties change with a material upgrade and if there are expected impacts to overall performance of the parachute. The objective of this test was to measure the elongation of different Kevlar types at both the cord-level and at the yarn-level to determine if a change in Kevlar type impacted parachute performance. An Instron machine with a pin-to-pin connection was used to measure load and displacement time histories for various Kevlar cord and yarn samples in a cyclic load profile. Twenty-four cord samples and twenty-four yarn samples were tested; each sample was cycled five times to the relevant maximum load (either to breaking strength or to the 30% peak load expected in flight). In addition to the Instron measurements, a photogrammetric technique was also implemented to measure elongation of the samples using button targets. Modulus test data shows approximately a 10% difference in elongation between Kevlar 29AP and Kevlar 129, and another 10% difference in elongation between Kevlar 29 and Kevlar 29AP. Although this is a measurable change in modulus, the effect on parachute performance is likely small, particularly for non-primary structure elements of relatively small length. This test campaign provides an example of the type of testing and analysis that parachute engineers could do to understand how material upgrades affect performance of their systems.

Modulus Testing↗

Thermally anisotropic composites for thermal management in building environments

An improved system for thermal management is provided. The system includes thermally anisotropic composites coupled with a thermal loop to re-direct, reduce, and shape heat flows through a building envelope, having the potential to (1) significantly reduce envelope-generated heating and cooling loads and (2) provide grid services such as decreasing peak loads and shaping energy use. In one embodiment, the thermal management system includes an anisotropic composite that consists of alternating layers of thermal insulation and thermally conductive materials that are immediately adjacent to each other, including polyisocyanurate foam boards and aluminum sheets. The thermal management system also includes a thermal loop along the long edge or the entire the perimeter of the anisotropic composite, the thermal loop having dynamically controlled or floating temperature that is maintained at lower than an outdoor ambient temperature (for cooling). An interior wall structure is inwardly adjacent to the anisotropic composite.

Shrestha, Som S.↗

Space station common module thermal management: Design and construction of a test bed

In this project, a thermal test bed was designed, simulated, and planned for construction. The thermal system features interior and exterior thermal loads and interfacing with the central-radiator thermal bus. Components of the test bed include body mounted radiator loop with interface heat exchangers (600 Btu/hr); an internal loop with cabin air-conditioning and cold plates (3400 Btu/hr); interface heat exchangers to the central bus (13,000 Btu/hr); and provisions for new technology including advanced radiators, thermal storage, and refrigeration. The apparatus will be mounted in a chamber, heated with lamps, and tested in a vacuum chamber with LN2-cooled walls. Simulation of the test bed was accomplished using a DEC PRO 350 computer and the software package TK! olver. Key input variables were absorbed solar radiation and cold plate loads. The results indicate temperatures on the two loops will be nominal when the radiation and cold plate loads are in the range of 25% to 75% of peak loads. If all loads fall to zero, except the cabin air system which was fixed, the radiator fluid will drop below -100 F and may cause excessive pressure drop. If all loads reach 100%, the cabin air temperature could rise to 96 F.

Barile, R. G.↗

Experimental investigation on phase change material–based finned tube heat exchanger for thermal energy storage and building envelope thermal management

Phase change materials (PCMs) are attractive solutions for thermal energy storage (TES) applications by absorbing and releasing large amounts of latent heat during solid–liquid phase transitions. However, their relatively low thermal conductivity requires novel heat exchanger–based solutions to improve the power density and overall energy storage efficiency of the TES system. This work presents the design and experimental results of a finned tube heat exchanger to store collected natural thermal energy from a building envelope in a latent-based TES and to release it later for building heating/cooling applications. We experimentally evaluate the finned tube heat exchanger and evaluate the performance of TES in reducing building heating and cooling loads over 3–4 h of desired time of operation (e.g., peak load). The optimized design allows for maximum energy density by minimizing the heat exchanger volume, and the system is evaluated experimentally using commercially available heat exchanger materials and an organic PCM. Here, the experimental results reveal that the TES system is able to charge and discharge stored latent energy within 3–4 h, matching peak building electricity demand duration under an average fluid flow rate of 0.136 kg/s and temperature difference of 5.55 °C. Importantly, such optimized designs illuminate a path toward TES designs that are low-cost, scalable, and optimized for thermal energy and power availability under the desired time of operation.

25 ENERGY STORAGE↗

Electrical and Thermal Load Impacts of Three District Heating and Cooling Designs for an Existing Community in Washington, DC

District energy systems that provide building heating and cooling are a promising option to provide low-cost, energy efficient heating and cooling solutions for communities. As some buildings move to electrified heating designs, there may be significant increases in electric grid demand, particularly in the winter. District energy systems may be able to help reduce these high electrical demands on the electric grid, while also providing decreased overall energy consumption with an increased flexibility in electrical energy usage. To evaluate and compare district options for district-based heating and cooling, an existing neighborhood of Washington, DC consisting of 35 existing buildings was selected as a case study. This study models and compares a fourth generation (4G) district heating and cooling systems that provide hot and chilled water from a central plant directly to each prosumer and a fifth generation (5G) district heating and cooling systems that provide near-ambient water via geothermal boreholes to interface with an energy transfer station with a heat pump at each prosumer. These district systems are compared against a baseline of the non-connected buildings with their self-contained and current HVAC systems. The neighborhood was selected as a good candidate for a district system for its diversity of loads (mix of different commercial and property types) and the availability of building characteristics. URBANopt District Energy Systems (DES) was used to model the buildings and create initial Modelica models for the district systems. Finally, the DES models were tuned and simulated in Dymola, and the outputs were post-processed for verification and to calculate the electrical and thermal grid impact metrics. This is the first documentation of this workflow and its complete analysis. The three designed systems are compared via their grid metrics including: total energy consumption, electrical demand peak loads, daily peak-to-valley ratios, and system ramping. A detailed discussion is provided about how each system impacts and interacts with the electric grid.

15 GEOTHERMAL ENERGY↗

Factors Influencing Grid-connected Heat Pump Water Heater Performance in the Southeast U.S.

Grid-connected heat pump water heaters (HPWH) can shift electrical load while minimizing impacts to hot water availability for occupants. This capability provides a flexible grid resource to utilities seeking to manage peak loads Such load control also can feasibly improve renewable utilization within the utility electric production mix, for instance using off-peak generation during periods with high renewable energy generation. It also offers lower electric bills to customers through increased energy efficiency of HPWH and cuts greenhouse gas emissions. In particular, the Southeast U.S. due to its high penetration of electric water heating presents a promising opportunity for grid-connected HPWHs. This paper builds upon the results of an extensive HPWH load shifting field study conducted in 51 occupied homes in Florida using EcoPort technology (Butzbaugh et al, 2022). In 2022, only an initial evaluation was available. Here, long term load results are available as well as examination of various control strategies and influences. Analysis is conducted for HPWH energy use and load shifting performance based on home occupancy (i.e., low and high) and water heater location (i.e., conditioned and unconditioned) across different temperature profiles. An unexpected outcome of this analysis was the poor performance of HPWHs located in conditioned spaces, possibly because of inadequate air volume from improper installation. We did find higher demand reductions from 2-hour load ups and slightly improved for critical peak signals in the afternoon control periods. As expected, higher occupancy households showed great load reductions.

Fenaughty, Karen↗

Energy, power, and infrastructure demands from electrifying airport ground support equipment at United States airports

As the airline industry seeks to reduce costs and transition to clean energy, electric ground support equipment is emerging as a favorable option. The integration of electric ground support equipment into airport operations requires careful planning for vehicle deployment, charging infrastructure, and grid impacts. We develop a flexible, bottom-up modeling framework to assess energy and infrastructure needs across more than 300 U.S. airports. Our analysis estimates site-specific power and energy demand, equipment counts by type, charger requirements, and costs. Here we quantify the magnitude of new electrical loads created by the electrification of airport ground support equipment, finding that peak power demand at the largest airports can reach up to 20 megawatts, with annual electricity consumption approaching 51,000 megawatt-hours. We further show that behind-the-meter battery energy storage systems and solar photovoltaic systems can reduce peak load and lower total system costs by as much as 10 million dollars.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The influence of modifications of a fatigue loading history program on fatigue lifetime

Rectangular specimens of 7075 and 2014 aluminum alloys with two holes (stress concentration factor of 3.24) have been tested under axial fatigue loading on a six-rod test bed with modifications of the loading program, the surface particulars, and the frequency. The length of the precrack stage was investigated by use of a new crack detector. In most cases the two alloys behaved similarly, with similar life to crack start under the same loading. Some overloads lengthened the life. Truncation by omission of the lowest peak loads should be limited to about 20 percent of the ultimate load. Simplifying counting methods gave misleading results. Very thin surface layers of anodizing, protection by vinyl, dry nitrogen atmosphere, as well as stepwise reaming or grinding the surface of the holes, lengthened the life; thick anodized layers shortened the life. Compressing the hole surface by rolling had no influence. Frequencies at about 210 to 240 cpm produced shorter lives than those at 40 cpm. At 5.4 cpm the life was considerably longer. A model to better understand the precrack-stage fatigue mechanism is discussed.

Branger, J.↗

Studies of aerothermal loads generated in regions of shock/shock interaction in hypersonic flow

Experimental studies were conducted to examine the aerothermal characteristics of shock/shock/boundary layer interaction regions generated by single and multiple incident shocks. The presented experimental studies were conducted over a Mach number range from 6 to 19 for a range of Reynolds numbers to obtain both laminar and turbulent interaction regions. Detailed heat transfer and pressure measurements were made for a range of interaction types and incident shock strengths over a transverse cylinder, with emphasis on the 3 and 4 type interaction regions. The measurements were compared with the simple Edney, Keyes, and Hains models for a range of interaction configurations and freestream conditions. The complex flowfields and aerothermal loads generated by multiple-shock impingement, while not generating as large peak loads, provide important test cases for code prediction. The detailed heat transfer and pressure measurements proved a good basis for evaluating the accuracy of simple prediction methods and detailed numerical solutions for laminar and transitional regions or shock/shock interactions.

Holden, Michael S.↗