Plasma double-layers produced by ponderomotive force

Non-linear rectification of the RF electric fields excited in a convectively amplifying electron beam-plasma interaction results in a dc electric field, and a corresponding ponderomotive force acting on the charged particles to produce a space-charge separation, i.e. a type of plasma double-layer. This paper analyses the effect, taking into account plasma electron temperature and electron-neutral collisions. To measure such double-layers, an electron beam probe constitutes a convenient non-perturbing diagnostic technique, but great care is required in its calibration. An analysis is presented taking into account significant non-linear effects which had been neglected in previous work. The paper concludes with some preliminary experimental results illustrating the use of the technique in a beam-plasma interaction for which a weak double-layer electric field is predicted.

Levine, J. S.↗

Radiometry using synchrotron radiation

It is possible to use synchrotron radiation from electron synchrotrons and electron storage rings as an absolute source, especially in the VUV and soft X-ray regions where other standards are difficult to find. At the NBS, an electron storage ring (SURF-II) has been used to calibrate spectrometers and photometers utilized in solar and aeronomy research and in fusion plasma diagnostics. The radiation incident on these spectrometers can be calculated to uncertainties of 3%, and a technique to exactly determine the number of electrons orbiting in the ring is currently being developed to reduce this uncertainty. Detector calibrations between 5 and 55 nm are routinely performed at SURF-II and transfer standard detectors with 6-10% uncertainties over the range 5-254 nm are supplied.

Saloman, E. B.↗

Diagnostic for Plasma Enhanced Chemical Vapor Deposition and Etch Systems

In order to meet NASA's requirements for the rapid development and validation of future generation electronic devices as well as associated materials and processes, enabling technologies ion the processing of semiconductor materials arising from understanding etch chemistries are being developed through a research collaboration between Stanford University and NASA-Ames Research Center, Although a great deal of laboratory-scale research has been performed on many of materials processing plasmas, little is known about the gas-phase and surface chemical reactions that are critical in many etch and deposition processes, and how these reactions are influenced by the variation in operating conditions. In addition, many plasma-based processes suffer from stability and reliability problems leading to a compromise in performance and a potentially increased cost for the semiconductor manufacturing industry. Such a lack of understanding has hindered the development of process models that can aid in the scaling and improvement of plasma etch and deposition systems. The research described involves the study of plasmas used in semiconductor processes. An inductively coupled plasma (ICP) source in place of the standard upper electrode assembly of the Gaseous Electronics Conference (GEC) radio-frequency (RF) Reference Cell is used to investigate the discharge characteristics and chemistries. This ICP source generates plasmas with higher electron densities (approximately 10(exp 12)/cu cm) and lower operating pressures (approximately 7 mTorr) than obtainable with the original parallel-plate version of the GEC Cell. This expanded operating regime is more relevant to new generations of industrial plasma systems being used by the microelectronics industry. The motivation for this study is to develop an understanding of the physical phenomena involved in plasma processing and to measure much needed fundamental parameters, such as gas-phase and surface reaction rates. species concentration, temperature, ion energy distribution, and electron number density. A wide variety of diagnostic techniques are under development through this consortium grant to measure these parameters. including molecular beam mass spectrometry (MBMS). Fourier transform infrared (FTIR) spectroscopy, broadband ultraviolet (UV) absorption spectroscopy, a compensated Langmuir probe. Additional diagnostics. Such as microwave interferometry and microwave absorption for measurements of plasma density and radical concentrations are also planned.

Cappelli, Mark A.↗

A heavy ion beam probe system for investigation of a modified Penning discharge

An ion beam probe diagnostic system can measure time- and space-resolved profiles of plasma space potential and electron density. In combination with a computer iterative technique, the ion beam probe can determine both the space potential profile in plasmas containing strong electric fields and potentials comparable in magnitude to the energy of the probing ion beam. During ion beam probing of a modified Penning discharge, several groups of secondary ions were observed coming from the plasma with a fixed primary beam energy and momentum. The energies of these ions were within 10 percent of the values predicted by a computer-generated model of the potential profile in the plasma. The mechanical and electronic components of the system are described, with particular emphasis on those features required to probe plasma potentials comparable in magnitude to the ion beam energy.

Kambic, G. X.↗

Deriving Large Coronal Magnetic Loop Parameters Using LOFAR J Burst Observations

Large coronal loops around one solar radius in altitude are an important connection between the solar wind and the low solar corona. However, their plasma properties are ill-defined, as standard X-ray and UV techniques are not suited to these low-density environments. Diagnostics from type J solar radio bursts at frequencies above 10 MHz are ideally suited to understand these coronal loops. Despite this, J-bursts are less frequently studied than their type III cousins, in part because the curvature of the coronal loop makes them unsuited for using standard coronal density models. We used LOw-Frequency-ARray (LOFAR) and Parker Solar Probe (PSP) solar radio dynamic spectrum to identify 27 type III bursts and 27 J-bursts during a solar radio noise storm observed on 10 April 2019. We found that their exciter velocities were similar, implying a common acceleration region that injects electrons along open and closed magnetic structures. We describe a novel technique to estimate the density model in coronal loops from J-burst dynamic spectra, finding typical loop apex altitudes around 1.3 solar radius. At this altitude, the average scale heights were 0.36 solar radius, the average temperature was around 1 MK, the average pressure was 0.7mdyn cm -2 , and the average minimum magnetic field strength was 0.13 G. We discuss how these parameters compare with much smaller coronal loops.

Jinge Zhang↗

Electron cyclotron resonance deposition and plasma diagnostics of a-Si:H and a-C:H films

Amorphous silicon (a-Si:H) and amorphous carbon (a-C:H) films deposited by electron cyclotron resonance (ECR) microwave plasma-enhanced chemical vapor deposition are discussed. It is shown that the ECR microwave plasma deposition technique can produce a-Si:H films with material qualities similar to and with a deposition rate one order of magnitude higher than for films deposited by radio-frequency glow discharge. The ECR-deposited a-C:H films are characterized by fluorescence, IR, and Raman spectroscopy. In situ optical emission spectroscopy plasma diagnostics indicates that ECR plasmas have a strong emission at 434 nm, which indicates a higher chemical reactivity than radio-frequency glow discharge plasmas. The radio frequency bias to the substrate is found to play a critical role in determining the film structure and the carbon bonding configuration of ECR-deposited a-C:H films.

Shing, Y. H.↗

Monolithic millimeter-wave diode array beam controllers: Theory and experiment

In the current work, multi-function beam control arrays have been fabricated and have successfully demonstrated amplitude control of transmitted beams in the W and D bands (75-170 GHz). While these arrays are designed to provide beam control under DC bias operation, new designs for high-speed electronic and optical control are under development. These arrays will fill a need for high-speed watt-level beam switches in pulsed reflectometer systems under development for magnetic fusion plasma diagnostics. A second experimental accomplishment of the current work is the demonstration in the 100-170 GHz (D band) frequency range of a new technique for the measurement of the transmission phase as well as amplitude. Transmission data can serve as a means to extract ('de-embed') the grid parameters; phase information provides more complete data to assist in this process. Additional functions of the array beam controller yet to be tested include electronically controlled steering and focusing of a reflected beam. These have application in the areas of millimeter-wave electronic scanning radar and reflectometry, respectively.

Sjogren, L. B.↗

Electric Field Double Probe Measurements on Satellites with Very Low Perigees

Measurements of DC and AC electric Fields at low altitudes (less than 150 km) in the Earth's ionosphere address a wide array of important scientific questions including Joule Heating, the closure of field aligned currents, and the deviation of E x B electron velocities from ion velocity vectors influenced by collisions. Double probes represent a well-proven technique for gathering high quality DC and AC electric field measurements for which the design of the boom system is of critical importance for the success of the experiment. In general, ionospheric DC electric field instruments that achieve accuracies of 0.1 mV/m or better, place sensors at large distances from the spacecraft body in order to extend well beyond the spacecraft wake and sheath and to achieve the large signal-to-noise ratios for DC and long wavelength measurements. Additional sets of sensors inboard of the primary, outermost sensors provide useful additional information, both for diagnostics of the plasma contact potentials, which particularly enhance the DC electric field measurements on non-spinning spacecraft, and for wavelength and phase velocity measurements that use the spaced receiver or "Interferometer" technique. Accurate attitude knowledge enables V x B contributions to be subtracted from the measured potentials, and permits the measured components to be rotated into meaningful geophysical reference frames. This presentation discusses the expected performance of electric field double probe experiments and their boom mechanisms on both spinning and non-spinning satellite platforms with very low perigees. Careful selection of probe surface materials, such as titanium nitride, for the low perigee environment, as well as thermal considerations are also discussed.

Pfaff, R. F., Jr.↗

Electric Field Double Probe Measurements for Ionospheric Space Plasma Experiments

Double probes represent a well-proven technique for gathering high quality DC and AC electric field measurements in a variety of space plasma regimes including the magnetosphere, ionosphere, and mesosphere. Such experiments have been successfully flown on a variety of spacecraft including sounding rockets and satellites. Typical instrument designs involve a series of trades, depending on the science objectives, type of platform (e.g., spinning or 3-axis stabilized), expected plasma regime where the measurements will be made, available telemetry, budget, etc. In general, ionospheric DC electric field instruments that achieve accuracies of 0.1 mV/m or better, place spherical sensors at large distances (10m or more) from the spacecraft body in order to extend well beyond the spacecraft wake and sheath and to achieve large signal-to-noise ratios for DC and long wavelength measurements. Additional sets of sensors inboard of the primary, outermost sensors provide useful additional information, both for diagnostics of the plasma contact potentials, which particularly enhance the DC electric field measurements on non-spinning spacecraft, and for wavelength and phase velocity measurements that use the spaced receiver or "interferometer" technique. Accurate attitude knowledge enables B times V contributions to be subtracted from the measured potentials, and permits the measured components to be rotated into meaningful geophysical reference frames. We review the measurement technique for both DC and wave electric field measurements in the ionosphere discussing recent advances involving high resolution burst memories, multiple baseline double probes, new sensor surface materials, biasing techniques, and other considerations.

Pfaff, R.↗

A comparison of the C III, O V, F VI, and Ne VII Delta n = 0 (2-2) line emissions from a laboratory plasma with theoretical predictions and astrophysical observations

Spectra of the Delta n = 0 (2-2) transitions of Be I-like ions, C III, O V, F VI, and Ne VII emitted from the TEXT tokamak, were measured with photometrically calibrated instrumentation and compared to the predictions of several models which differ in their treatment of electron impact excitation, using either the distorted wave or R-matrix approach. It was found that the ions from C III to Ne VII were located near the edge of the plasma, at densities between 10 to the 12th and 13th/cu cm. The experimental line ratios were compared with several sets of computations. Agreement is obtained between the experimental data and computations by using the R-matrix technique. This leads to the conclusion that the effect resonances must be included in collision strength calculations, particularly at low nuclear charge. The results show that the line ratios studied may be used with confidence as electron density diagnostics for laboratory or astrophysical plasmas.

Finkenthal, M.↗

SUMMA hot-ion plasma heating research at NASA Lewis Research Center

This report describes the SUMMA superconducting magnetic mirror facility at the NASA Lewis Research Center and the hot-ion plasma research conducted therein. SUMMA is characterized by intense magnetic fields (designed for 8.6 T at the mirrors) and a large-diameter working bore (41 cm diameter) with room-temperature access. The goal of the plasma research program is to produce steady-state plasmas of fusion reactor densities and temperatures (but not confinement times). The program includes electrode development to produce a hot, dense, large-volume, steady-state plasma and diagnostics development to document the plasma properties. SUMMA and its hot-ion plasma are ideally suited to develop advanced plasma diagnostics methods. Two such methods whose requirements are well matched to SUMMA are: (1) heavy ion beam probing to measure plasma space potential, and (2) submillimeter wavelength laser Thomson scattering to measure local ion temperature. Two NASA University Grants were established to identify major requirements for developing these two diagnostic techniques in SUMMA.

Reinmann, J. J.↗

Demonstrating the limitations of line ratio temperature diagnostic using Fe X and Fe XIV spectral line intensity observations

The electron temperature in the inner corona can be derived from spectral line intensity measurements by comparing the ratio of the measured intensities of two spectral lines to the ratio calculated from theoretical models. In a homogeneous plasma the line ratio technique can be used for any two lines if the ratio of the intensities is independent of the density. The corona, however, is far from homogeneous. Even large coronal holes present at the solar poles at solar minimum can be partly or completely obscured by emission from hotter and denser surrounding regions. In this paper we investigate the effect of these surrounding regions on coronal hole temperatures. using daily intensity measurements at 1.15 Rs of the Fe XIV 5303 A and Fe X 6374 A spectral lines carried out at the National Solar Observatory at Sacramento Peak. We show that the temperatures derived using the line ratio technique for these two spectral lines can vary by more than 0.8 x 10(exp 6) K due to the contribution from surrounding regions. This example demonstrates the inadequacy of spectral lines with widely separate peak temperatures for temperature diagnostic.

Brickhouse, Nancy↗

Spectroscopic Diagnostics and an Arc Jet Heated Air Plasma

Spectral radiation measurements were made in the range of 200 to 900 nm across a section of the plenum of an arc jet wind tunnel using a series of optical fibers. The spectra contained line radiation from Oxygen and Nitrogen atoms and molecular radiation from N2(+), N2, and NO. Abel inversion technique is used to obtain radial distribution of the spectra. The analysis yielded radial profiles of the electronic excitation, vibrational and rotational temperatures of the flow field. Spectral fitting yielded branching ratios for different vibrational and rotational bands. Relatively mild flow conditions, i.e. enthalpy and mass flow rate, were used for prolonged measurements of up to and over two hours to establish the best experimental methods of temperature determinations. Signal to noise was improved by at least an order of magnitude enabling the molecular vibrational band heads of N2(+) (first negative system), N2 (second positive system), and NO (beta, gamma, delta, and epsilon systems) to be resolved in the lower ultraviolet wavelength regions. The increased signal to noise ratio also enabled partial resolution of the rotational lines of N2(+) and N2 in certain regions of minimal overlap. Comparison of the spectra with theoretical models such as the NEQAIR2 code are presented and show potential for fitting the spectra when reliable calibration is performed for the complete wavelength range.

Mack, Larry Howard, Jr.↗

Simulated O VI Doppler dimming measurements of coronal outflow velocities

The possibility of determining O(5+) outflow velocities by using a Doppler dimming analysis of the resonantly scattered intensities of O VI lambda 1031.9 and lambda 1037.6 is addressed. The technique is sensitive to outflow velocities, W, in the range W greater than 30 and less than 250 km/s and can be used for probing regions of the inner solar corona, where significant coronal heating and solar wind acceleration may be occurring. These velocity measurements, when combined with measurements of other plasma parameters (temperatures and densities of ions and electrons) can be used to estimate the energy and mass flux of O(5+). In particular, it may be possible to locate where the flow changes from subsonic to supersonic and to identify source regions for the high and low speed solar wind. The velocity diagnostic technique is discussed with emphasis placed on the requirements needed for accurate outflow velocity determinations. Model determinations of outflow velocities based on simulated Doppler observations are presented.

Strachan, Leonard↗

Microwave diagnostic for the determination of the electron temperature of a low density shock-heated argon plasma

The diffraction, defocusing and beam bending effects of microwaves transmitted through a bounded shock-heated argon plasma with low electron density are investigated with the purpose of developing an accurate method for electron temperature (Te) determination. This report describes the evaluation technique and presents results for an argon plasma with pressure between 3 and 10 torr, and T2 between 5500 and 9500 K. The electron temperature values obtained have a range of uncertainty between -20% and +10% only. The electron temperature is equal or lower by approximately 1000 K in comparison to the heavy particle temperature (T2).

Schneider, C. P.↗

Variable frequency VLF signals in the magnetosphere Associated phenomena and plasma diagnostics

Coherent variable-frequency signals (ramps) extending from 1 to 8 kHz, injected into the magnetosphere from Siple Station, Antarctica (L=4.3), exhibit upper and lower cutoffs when received at the conjugate station, Roberval, Quebec. Ramp group delay measurements and ionospheric sounding data are used to determine the cold plasma density and L shell of the propagation path. Relationships among f, df/dt, and the 'phase equator' for gyroresonance are calculated using second-order resonance equations generalized to relativistic electrons. The concept thereby introduced is used to develop a diagnostic technique which, for an assumed g(alpha)(v exp -n) electron distribution, provides an estimate of the energy dependence n. Additional aspects of the magnetospheric response to ramp injection, such as emission triggering, curvature due to dispersion, and amplitude saturation, are discussed.

Carlson, C. R.↗

Physics of Solar Prominences: I-Spectral Diagnostics and Non-LTE Modelling

This review paper outlines background information and covers recent advances made via the analysis of spectra and images of prominence plasma and the increased sophistication of non-LTE (i.e. when there is a departure from Local Thermodynamic Equilibrium) radiative transfer models. We first describe the spectral inversion techniques that have been used to infer the plasma parameters important for the general properties of the prominence plasma in both its cool core and the hotter prominence-corona transition region. We also review studies devoted to the observation of bulk motions of the prominence plasma and to the determination of prominence mass. However, a simple inversion of spectroscopic data usually fails when the lines become optically thick at certain wavelengths. Therefore, complex

Labrosse, N.↗

Transition region response of the symmetric double probe and its application in the lower ionosphere

The technique is discussed of the symmetric double-probe which readily lends itself to the in situ measurement of plasma temperature in the ionospheric D-region because it can lead to meaningful results under relatively high collision frequencies where the Langmuir probe has been observed to fail. It is shown that the modification to the original collision-free double-probe theory of Johnson and Malter for the determination of electron temperature is never greater than + or - 12%, with a value of (8 + or - 2)% nominally applicable in the case of D-region diagnostics. This technique was successfully operated on a Nike-Cajun payload flown at mid-day from White Sands, New Mexico to an apogee of 78.5 km. The associated electronics and deployed double-probe configuration are presented, and a current-voltage characteristic collected in the ascent stage at 73.7 km is briefly discussed. The values of electron temperature indicated by the sampled data are approximately 30% higher than those predicted by theory for the anticipated state of thermal equilibrium with the ambient neutrals.

Szuszczewicz, E. P.↗