Investigations into EGR dilution tolerance in a pre-chamber ignited GDI engine

EGR is a useful means to improve fuel economy in spark-ignited gasoline engines, especially under part-load conditions by means of reducing throttling losses. There is also a significant reduction in NOx emissions due to the reduced peak cylinder temperatures. However, the ability of conventional spark ignition systems to reliably ignite dilute mixtures limits the dilution tolerance due to the onset of combustion instability. In this study, an active pre-chamber system was evaluated at part load condition with various EGR rates using a regular grade full boiling range gasoline. A premixed air-fuel mixture was supplied to the pre-chamber, which assists in scavenging the residual mass fractions to enable reliable ignition of EGR dilute mixtures in the main combustion chamber. A range of pre-chamber injection, air-fuel mixture formulation, and ignition timing strategies were evaluated during the EGR sweeps. In addition, 0-D and 1-D simulations were conducted in GT-Power to assess the thermodynamic state and composition in the pre-chamber, as well as estimate the jet momentum at the various dilution rates. The active pre-chamber extended the EGR dilution limit from 20% for conventional SI to above 30%, with a higher pre-chamber flow rate (more scavenging) resulting in increased combustion stability. A tradeoff between the jet momentum and spark timing was observed when analyzing the GT-Power simulations and the pre-chamber jet momentum was found to decrease with increasing EGR rate. At unstable high EGR operation, no relation could be found between the pre-chamber indicated data and main chamber combustion stability.

33 ADVANCED PROPULSION SYSTEMS↗

Impact of Time-Dependent Reactor and Sensor Physics on Core Power Synthesis (Rev.1)

Online synthesis of power distribution is critical in the operation and control of nuclear power reactors to ensure that the core is operating within safety margins and to provide essential knowledge associated with the burnup of the fuel. In light-water reactors, power synthesis is achieved by using some a priori knowledge of the state of the reactor core and updating based on the signals coming from in-core sensors—namely, self-powered neutron detectors (SPNDs). This report examines the effects of fuel burnup and sensor degradation on the ability to accurately synthesize the power distribution in a pressurized water reactor (PWR), considering the typical low-enriched uranium (LEU, 3%-5% enrichment) fuel cycle as well as the higher enrichment LEU+ (5%-8% enrichment) fuel cycle. Several modeling tools were used to simulate power synthesis based on the responses of SPNDs, with emitters made out of Rh or V. A representative PWR LEU core was modeled using the Polaris/Purdue Advanced Reactor Core Simulator (PARCS) approach. The Monte Carlo N-Particle Transport 6 (MCNP6) code was used as well to calculate response functions between different segments of fuel to individual SPNDs; this is a crucial parameter for power synthesis. The Oak Ridge Isotope GENeration (ORIGEN) package in the Standardized Computer Analyses for Licensing Evaluation (SCALE) code was used to model the time-dependent isotopic transmutation in the SPND emitters. All these data were fed into a custom code that enacted the point-based iterative method to simulate power synthesis. Developmental work was also performed on high-fidelity SPND models in the GEometry ANd Tracking 4 (Geant4) code, which enables higher-accuracy modeling of the current responses from SPNDs. In this work, five sets of time-dependent power synthesis test cases were conducted. In these test cases, systematic changes in the input conditions enabled an analysis of the effect of (1) slightly inaccurate a priori power distribution assumptions with respect to fuel burnup, (2) highly inaccurate a priori power distribution assumptions with respect to fuel burnup (such that burnup is not included in the a priori assumed distribution), and (3) differences between Rh and V SPNDs in terms of downstream consequences of the transmutation in the emitters and the extended nature of the LEU+ fuel cycle in comparison with LEU. The authors discovered that one may permissibly have slightly inaccurate a priori assumptions of the fuel burnup (such that the level of burnup may be slightly underapproximated or overapproximated by the accumulated burnup in approximately 9.3 full power days), but to not account for burnup at all in the a priori assumptions leads to severe levels of error, approaching 25% at maximum (for LEU). The authors also discovered that V SPNDs are extraordinarily robust in both the LEU and LEU+ fuel cycles considered in this modeling work, whereas Rh SPNDs undergo significant transmutation that can result in large errors in the synthesized power distribution.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Probabilistic Resource Adequacy Suite (PRAS) v0.6 Model Documentation

The Probabilistic Resource Adequacy Suite, or PRAS, is a software package for studying power system resource adequacy. It allows the user to simulate power system operations under a wide range of operating conditions, in order to study the system’s risk of failing to meet demand due to a resource shortfall, and identify the time periods and regions in which that risk occurs. This reports documents version 0.6 of the tool.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Probabilistic Resource Adequacy Suite (PRAS) v0.8 Model Documentation

The Probabilistic Resource Adequacy Suite, or PRAS, is a software package for studying power system resource adequacy. It allows the user to simulate power system operations under a wide range of operating conditions, in order to study the system's risk of failing to meet demand due to a resource shortfall, and identify the time periods and regions in which that risk occurs. This reports documents version 0.8 of the tool.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Understanding Power and Energy Utilization in Large Scale Production Physics Simulation Codes

Power is an often-cited reason for moving to advanced architectures on the path to Exascale computing. This is due to the practical concern of delivering enough power to successfully site and operate these machines, as well as concerns over energy usage while running large simulations. Since accurate power measurements can be difficult to obtain, processor thermal design power (TDP) is a possible surrogate due to its simplicity and availability. However, TDP is not indicative of typical power usage while running simulations. Using commodity and advance technology systems at Lawrence Livermore National Laboratory (LLNL) and Sandia National Laboratory, we performed a series of experiments to measure power and energy usage in running simulation codes. These experiments indicate that large scale LLNL simulation codes are significantly more efficient than a simple processor TDP model might suggest.

97 MATHEMATICS AND COMPUTING↗

Charaterization of Emerging Computing Architectures for Dynamic Simulation of Future Power Grids with Large-Scale Power Electronics

The increasing penetration of power electronics in power grids significantly raises the computing requirements in a real-time (and/or fast) simulation of the power grid. The real-time simulation is an enabler for evaluating controllers, protection systems, new equipment, and twinning. In this paper, emerging computing architectures such as tensor processing units (TPU), neural/neuromorphic processing units (NPU), and quantum processing units (QPU) are introduced and characterized for the real-time (and/or fast) simulation of power electronics-dominated power grids. The metrics and the process to characterize emerging computing architectures to perform real-time (and/or fast) simulations of future power grids with power electronics are discussed. Three of the emerging computing units are characterized based on these metrics and the process developed. This characterization will enable identification and comparison of emerging computing architectures that can perform real-time (and/or fast) simulation of future power grids.

Choi, Jongchan↗

Networked HIL Simulation System for Modeling Large-scale Power Systems

This paper presents a networked hardware-in-the-loop (HIL) simulation system for modeling large-scale power systems. Researchers have developed many HIL test systems for power systems in recent years. Those test systems can model both microsecond-level dynamic responses of power electronic systems and millisecond-level transients of transmission and distribution grids. By integrating individual HIL test systems into a network of HIL test systems, we can create large-scale power grid digital twins with flexible structures at required modeling resolution that fits for a wide range of system operating conditions. This will not only significantly reduce the need for field tests when developing new technologies but also greatly shorten the model development cycle. In this paper, we present a networked OPAL-RT based HIL test system for developing transmission-distribution coordinative Volt-VAr regulation technologies as an example to illustrate system setups, communication requirements among different HIL simulation systems, and system connection mechanisms. Impacts of communication delays, information exchange cycles, and computing delays are illustrated. Simulation results show that the performance of a networked HIL test system is satisfactory.

Xie, Fuhong↗

PHIL Interface Design for Use With a Voltage-Regulated Amplifier: Preprint

As inverter controls have become increasingly complex, power hardware-in-the-loop (PHIL) has emerged as a leading strategy to thoroughly assess the impact of proprietary inverter controls on a specific power system. The development of a PHIL test bed typically involves the desired inverter, a power amplifier, and a digital real-time simulator (DRTS) to control the simulated power system. As a result of PHIL nonidealities, a form of digital compensation within the DRTS is used, which is commonly referred to as a PHIL interface. The interface design for PHIL test beds has been previously examined in the literature, but many existing methods use older power amplifiers that do not contain internal voltage regulation. These existing interface methods are based around a voltage regulator within the DRTS rather than one preexisting in hardware. In this study, a three-step approach of PHIL interface development for modern power amplifiers with built-in voltage regulation is introduced and validated in hardware with a single 30-kW grid-following inverter.

DRTS↗

Understanding power and energy utilization in large scale production physics simulation codes

Power is an often-cited reason for the move to advanced architectures on the path to Exascale computing. Here, this is due to practical considerations related to delivering enough power to successfully site and operate these machines, as well as concerns about energy usage while running large simulations. Since obtaining accurate power measurements can be challenging, it may be tempting to use the processor thermal design power (TDP) as a surrogate due to its simplicity and availability. However, TDP is not indicative of typical power usage while running simulations. Using commodity and advanced technology systems at Lawrence Livermore and Sandia National Labs, we performed a series of experiments to measure power and energy usage in running simulation codes. These experiments indicate that large scale Lawrence Livermore simulation codes are significantly more efficient than a simple processor TDP model might suggest.

HPC↗

Air attenuation of high power XFEL beams

The Linac Coherent Light Source-II, a high-repetition-rate x-ray free electron laser, produces high average power as well as high peak power. Air is a key radiation safety element, helping to contain the FEL beams from reaching accessible areas. At high average power, air absorption can produce a high temperature and low-density channel along the x-ray beam path. In this case, the x-ray attenuation no longer follows the Beer-Lambert equation, e-μx . Air attenuation measurements were performed with x-rays focused into a gas cell at the LCLS Time-resolved AMO instrument. The air transmission was observed to significantly increase with x-ray power. Simulations were also performed, which include the thermal processes related to the high average power. In comparison to the measurements, the calculated air transmission is higher, confirming that the simulations are conservative and suitable for radiation safety analyses.

42 ENGINEERING↗

The power reliability event simulator tool (PRESTO): A novel approach to distribution system reliability analysis and applications

The growing interest in onsite solar photovoltaic and energy storage systems is partially motivated by customer concerns regarding grid reliability. However, accurately assessing the effectiveness of PVESS in mitigating these interruptions requires a comprehensive understanding of location-specific outage patterns and the ability to simulate realistic scenarios. To address the gap, we introduce the Power Reliability Event Simulation TOol (PRESTO), the first publicly available tool that simulates location-specific power interruptions at the county level. PRESTO allows for a more realistic assessment of system reliability by considering the unpredictability and location-specific patterns of power interruptions. We applied PRESTO in a case study of a single-family home across three U.S. counties, examining the performance of a solar photovoltaic system with 10kWh of battery storage during short-duration power interruptions. Our findings show that this system reliably met 93% of energy demand for essential non-heating and cooling loads, fully serving these loads in 84% of events, despite the constraints of daily time-of-use bill management which limits the battery's state-of-charge reserve. However, when heating and cooling loads were included, system performance decreased significantly, with only 70% of demand met and full service in 43% of events. These results highlight the challenges of using solar photovoltaic and energy storage systems for short-duration outages, emphasizing the need to consider factors like battery size and grid charging strategies to improve reliability. Our study demonstrates the practical applications of PRESTO, providing valuable insights into potential mitigation strategies including grid charging and optimizing battery size.

14 SOLAR ENERGY↗

Enhancing Monte Carlo Workflows for Nuclear Reactor Analysis with Metamodel-Driven Modeling

Monte Carlo codes are essential components of many reactor physics simulation workflows as high-fidelity continuous-energy neutron transport solvers. Among Monte Carlo radiation transport codes, MCNP is particularly notable due to its diverse simulation capabilities, large user base, and long validation history. Despite being a powerful simulation tool, MCNP provides limited capabilities to allow automated execution, model transformation, or support for user-defined logic and abstractions that limit its compatibility with modern workflows. Here, to better integrate MCNP into a modern scientific workflow, we have developed an intuitive yet full-featured MCNP Application Program Interface (API) in Python, named MCNPy, which provides a specialized set of classes for MCNP input development. Moreover, to guarantee that our reading, writing, and modeling capabilities remain self-consistent (and to render the huge scope of the MCNP API manageable), we have adopted a strategy of model-driven software development in which a generalized model of the MCNP input format has been created. From this generalized model, or “metamodel,” problem-specific implementations such as an engine for input validation or a codebase for programmatic operations may be automatically generated. Since MCNPy primarily acts as a Python front-end to the underlying Java API that directly interfaces with the metamodel, it is intrinsically linked to the metamodel and thus remains maintainable. With MCNPy, users can programmatically read, write, and modify any syntactically valid MCNP input file regardless of its origin. These capabilities allow users to automate complicated tasks like design optimization and model translation for nuclear systems. As examples, this work demonstrates the use of MCNPy to find the critical radius of a plutonium sphere and to translate a 9000+ line MCNP input file into a corresponding OpenMC model.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Dynamic Modeling of Power Conversion Stages for an Exascale Supercomputer

In this paper a power conversion and energy consumption model for an exascale supercomputer is investigated. Power consumption, energy loss and efficiency are derived for the 27.2 MW liquid-cooled, centralized, High Performance Computing (HPC) power system, which is supplied directly from the 480 V three-phase mains. Two energy conversion stages are analyzed, measured and modeled. The model is developed in order to be adapted and implemented in a digital twin platform utilizing a Resource Allocator and Power Simulator (RAPS) module. RAPS enables estimation of potential energy savings in the direct AC power supply architecture via both conventional rectifier load sharing (commonly used in HPC systems), as well as smart rectifier load sharing. Moreover, besides the direct AC supply architecture analysis, the full direct DC supply architecture with with 1 kV DC bus were also studied. Comparison of 10 hour time frame operation of the system, with direct 480 V AC voltage supply with conventional and smart load sharing and medium dc voltage supply were done. For the direct AC supply architecture, with conventional and smart load sharing the predicted power loss was approximately 840 kW and 820 kW, respectively and the predicted total system efficiency was 92.87% and 93.05%, respectively. For the direct DC supply architecture with the 1000 V DC supply bus power loss was approximately 340 kW and the predicted total system efficiency was 97.02%.

Wojda, Rafal↗

STEPS: A Portable Numerical Simulation Toolkit for Electrical Power System Dynamic Studies

Numerical simulation is the key technique for large scale power system analysis. Redistribution of global renewable power via international interconnections requires new simulation tools to study the interconnected systems with different nominal frequencies as a whole. In this paper we introduce an open source simulation toolkit for electrical power systems (STEPS) which is hosted at Github. Its kernel is coded in C++ with major functions of power flow and electro-mechanical dynamic simulation. Flexible options are provided and configurable to improve power flow solution and dynamic simulation. Common devices and models are supported in STEPS for AC/DC hybrid system studies. Studies of interconnected systems with different nominal frequencies is supported in STEPS for research of international interconnection. Application program interfaces are provided and wrapped with Python to enable high-level interfaces for general applications. STEPS is thread safe and parallel computation is supported in both kernel and script levels to accelerate simulation. It is portable and works on Windows and GNU/Linux platforms. Cases from small to large scale systems are thoroughly tested to validate the toolkit with commercial packages as benchmarks.

42 ENGINEERING↗

Multi-Physics Coupled Seismic Safety Analysis of Molten-Salt Reactors

Pool-type Molten Salt Reactors (MSRs) are a promising advanced nuclear reactor concept relying on passive physical behavior to provide increased safety characteristics. The high heat capacity, high boiling point, unpressurized liquid salt contains the nuclear fuel and as it passes through the vessel achieves criticality and produces nuclear power. The salt then carries away the heat produced along with the delayed neutron precursors towards heat exchangers and primary pumps before entering the core. This forms a highly coupled multiphysics problem between neutronics and fluid flow, which makes modeling these reactors challenging. The safety/licensing case heavily relies on modeling and simulation to prove their safety, and significant effort has been expanded by the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program to develop the appropriate simulation tools. Their safety/licensing will require a thorough analysis of their behavior during earthquake-based transients. Earthquakes are a transient condition commonly experienced in many regions, and are safely survived by dozens of reactors every year. Nonetheless, significant conservatisms were introduced with limited predictive modeling and simulation available. The first-of-a-kind capability developed by this research will allow for engineers to analyze ranges of design-basis and beyond-design basis accident scenarios to assess the integrity of the reactor vessel and surrounding system, possibly allowing for limiting the costly conservatisms in the design. This projects uses MASTODON, Griffin, and Pronghorn in the NEAMS ecosystem to model the coupled multiphysics problem posed by an earthquake in a molten salt reactor. It marches through a number of number of coupling schemes, from uncoupled simulations to tightly two-way coupled simulations. The appropriate level of coupling for these simulations will then be determined based on the accuracy in the quantities of interest (QoI) and computational effort involved in each scheme. The QoIs chosen for this paper include the mass flow rate across the heat exchanger (for Pronghorn simulations), power output of the reactor (for Griffin simulations), and the maximum Von Mises stress (for MASTODON simulations). This summary paper reports on the current progress of this project, with 2D tightly coupled multiphysics results.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Integrated Transmission-and-Distribution System Modeling of Power Systems: State-of-the-Art and Future Research Directions

Integrated transmission-and-distribution (T&D) modeling is a new and developing method for simulating power systems. Interest in integrated T&D modeling is driven by the changes taking place in power systems worldwide that are resulting in more decentralized power systems with increasingly high levels of distributed energy resources. Additionally, the increasing role of the hitherto passive energy consumer in the management and operation of power systems requires more capable and detailed integrated T&D modeling to understand the interactions between T&D systems. Although integrated T&D modeling has not yet found widespread commercial application, its potential for changing the decades-old power system modeling approaches has led to several research efforts in the last few years that tried to (i) develop algorithms and software for steady-state and dynamic modeling of power systems and (ii) demonstrate the advantages of this modeling approach compared with traditional, separated T&D system modeling. In this paper, we provide a review of integrated T&D modeling research efforts and the methods employed for steady-state and dynamic modeling of power systems. We also discuss our current research in integrated T&D modeling and the potential directions for future research. This paper should be useful for power systems researchers and industry members because it will provide them with a critical summary of current research efforts and the potential topics where research efforts are needed to further advance and demonstrate the utility of integrated T&D modeling.

24 POWER TRANSMISSION AND DISTRIBUTION↗