Search NASA⌕ Search

SEARCH · Search NASA

Results for “rapid analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Low Gravity Rapid Thermal Analysis of Glass

It has been observed by two research groups that ZrF4-BaF2-LaF3-AlF3-NaF (ZBLAN) glass crystallization is suppressed in microgravity. The mechanism for this phenomenon is unknown at the present time. In order to better understand the mechanism, an experiment was performed on NASA's KC135 reduced gravity aircraft to obtain quantitative crystallization data. An apparatus was designed and constructed for performing rapid thermal analysis of milligram quantities of ZBLAN glass. The apparatus employs an ellipsoidal furnace allowing for rapid heating and cooling. Using this apparatus nucleation and crystallization kinetic data was obtained leading to the construction of time-temperature-transformation curves for ZBLAN in microgravity and unit gravity.

Tucker, Dennis S.↗

Rapid Biochemical Analysis on the International Space Station (ISS): Preparing for Human Exploration of the Moon and Mars

The Lab-on-a-Chip Application Development - Portable Test System, known as LOCAD-PTS, was launched to the International Space Station (ISS) aboard Space Shuttle Discovery (STS-116) on December 9th,2006. Since that time, it has remained onboard ISS and has been operated by the crew on 10 separate occasions LOCAD-PTS is a handheld device for rapid biochemical analysis; it consists of a spectrophotometer, a series of interchangeable cartridges, a pipette and several clean/sterilized swabbing kits to obtain samples from ISS surfaces. Sampling, quantitative analysis and data retrieval is performed onboard, therefore reducing the need to return samples to Earth. Less than 20 minutes are required from sampling to data, significantly faster than existing culture-based methods on ISS, which require 3-5 days. Different cartridges are available for the detection of different target molecules (simply by changing the formulation within each cartridge), thereby maximizing the benefit and applications addressed by a single instrument. Initial tests on ISS have focused on the detection of the bact.erial macromolecule endotoxin, a component of bacterial cell walls. LOCAD-PTS detects endotoxin with a cartridge that contains a formulation known as Limulus Amebocyte Lysate (LAL) assay. LAL is derived from blood of the horseshoe crab, Limulus polyphemus, and detects enodotoxin with an enzyme cascade that triggers generation Of a yellow colored dye, p-nitroanaline. The more p-nitroanaline product, the more endotoxin is in the original sample. To enable quantitative analysis, the absorbance of this color is measured by LOCAD-PTS through a 395 nm filter and compared with an internal calibration curve, to provide a reading on the LED display that ranges from 0.05 Endotoxin Units (EU)/ml to 5 EU/ml. Several surface sites were analyzed within ISS between March 2007 and February 2008, including multiple locations in the US Laboratory Destiny, Node 1 Unity, AMock, and Service Module Zvezda. The goals of this initial study were to i) test the cleanliness of reagents/supplies on orbit, ii) test the crew's ability to collect and process a sample in microgravity without contamination, iii) demonstrate nominal function of the LOCAD-PTS, and iv) provide a general survey of endotoxin within the ISS. The surface sites varied greatly in terms of their frequency-of-use and material texture/composition; from relatively smooth aluminum, to fabric, to the room temperature vulcanizing (RTV) rubber of a Extravehicular Mobility Unit (EMU) spacesuit. Results showed that: i) the swabbing kits and reagents remained clean on orbit, ii) the crew could collect and process a sample without contamination, and iii) the LOCAD-PTS functioned nominally in > 99% of the 55 tests completed. We will present detailed results of the survey of endotoxin on ISS surfaces. These results and technology are important in the near-term - by providing an extra tool in the toolbox for ISS microbial monitoring. They are also important in the longer term as valuable preparation for human exploration of the Moon and Mars. One of the proposed science goals for the human exploration of Mars will be to detect and characterize any indigenous biological molecules that may exist on the Martian surface. To achieve that goal, the crew must have the technology available onboard to differentiate indigenous biology from any terrestrial biological material brought to Mars by the spacecraft and crew (termed 'forward contamination'). The LAL assay is already one of the official methods used by NASA's planetary protection program to certify cleanliness of interplanetary robotic spacecraft prior to launch; and therefore endotoxin is a good marker of forward contamination (as well as other microbial molecules detectable with LOCAD-PTS e.g. box-1, 3-glucan and lipoteichoic acid). Furthermore, the distribution and abundance of these molecules on the ISS provides a good indicator of what to expect on the Crew Exploratioehicle Orion, the lunar lander Antares, and future crewed spacecraft destined for Mars. In addition, technology such as LOCAD-PTS has been proposed to help evaluate forward contamination during lunar surface operations by the crew, as preparation for the human exploration of Mars.

Maule, J.↗

An Energy-Based Low-Order Approach for Mission Analysis of Air Vehicles in LEAPS

Mission analysis methods that allow rapid analysis of conceptual aircraft provide great benefits to designers because a large number of feasibility and optimization studies can be performed quickly. This paper presents a novel low-order mission analysis approach that will be included in a new aircraft analysis tool called the Layered and Extensible Aircraft Performance System, also known as LEAPS. This approach is based on the mission analysis method used in the Flight Optimization System, also known as FLOPS. FLOPS has been developed at NASA Langley Research Center for over 30 years, and it is mainly used to analyze conventional aircraft (e.g., gas turbine-powered aircraft). One of the main features of FLOPS is its ability to perform rapid mission analysis. This quick analysis turnaround makes FLOPS a suitable tool to perform a large number of trade studies and optimizations. For this reason, the main concepts applied in FLOPS will be used and expanded in LEAPS to allow the analysis of unconventional aircraft that use novel propulsion systems. This expanded approach includes the capability to handle electric propulsion systems as well as multiple propulsor classes at the same time. A novel hybrid-electric aircraft configuration is used to investigate the potential benefits of the proposed mission analysis approach. The results show that the design space increases which can potentially lead to better designs.

Capristan, Francisco M.↗

Challenges in the Use of AI-Driven Non-Destructive Spectroscopic Tools for Rapid Food Analysis

Routine, remote, and process analysis for foodstuffs is gaining attention and can provide more confidence for the food supply chain. A new generation of rapid methods is emerging both in the literature and in industry based on spectroscopy coupled with AI-driven modelling methods. Current published studies using these advanced methods are plagued by weaknesses, including sample size, abuse of advanced modelling techniques, and the process of validation for both the acquisition method and modelling. This paper aims to give a comprehensive overview of the analytical challenges faced in research and industrial settings where screening analysis is performed while providing practical solutions in the form of guidelines for a range of scenarios. After extended literature analysis, we conclude that there is no easy way to enhance the accuracy of the methods by using state-of-the-art modelling methods and the key remains that capturing good quality raw data from authentic samples in sufficient volume is very important along with robust validation. A comprehensive methodology involving suitable analytical techniques and interpretive modelling methods needs to be considered under a tailored experimental design whenever conducting rapid food analysis.

59 BASIC BIOLOGICAL SCIENCES↗

Stamping Nanoparticles onto the Electrode for Rapid Electrochemical Analysis in Microfluidics

Electrochemical analysis is an efficient way to study various materials. However, nanoparticles are challenging due to the difficulty in fabricating a uniform electrode containing nanoparticles. We developed novel approaches to incorporate nanoparticles as a working electrode (WE) in a three-electrode microfluidic electrochemical cell. Specifically, conductive epoxy was used as a medium for direct application of nanoparticles onto the electrode surface. Three approaches in this work were illustrated, including sequence stamping, mix stamping, and droplet stamping. Shadow masking was used to form the conductive structure in the WE surface on a thin silicon nitride (SiN) membrane. Two types of nanomaterials, namely cerium oxide (CeO2) and graphite, were chosen as representative nanoparticles. The as-fabricated electrodes with attached particles were characterized using atomic force microscopy (AFM) and time-of-flight secondary ion mass spectrometry (ToF-SIMS). Electrochemical analysis was performed to verify the feasibility of these nanoparticles as electrodes. Nanomaterials can be quickly assessed for their electrochemical properties using these new electrode fabrication methods in a microfluidic cell, offering a passport for rapid nanomaterial electrochemical analysis in the future.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Rapid subsurface analysis of frequency-domain thermoreflectance images with K-means clustering

K-means clustering analysis is applied to frequency-domain thermoreflectance (FDTR) hyperspectral image data to rapidly screen the spatial distribution of thermophysical properties at material interfaces. Performing FDTR while raster scanning a sample consisting of 8.6 μm of doped-silicon (Si) bonded to a doped-Si substrate identifies spatial variation in the subsurface bond quality. Routine thermal analysis at select pixels quantifies this variation in bond quality and allows assignment of bonded, partially bonded, and unbonded regions. Performing this same routine thermal analysis across the entire map, however, becomes too computationally demanding for rapid screening of bond quality. To address this, K-means clustering was used to reduce the dimensionality of the dataset from more than 20 000 pixel spectra to just K = 3 component spectra. The three component spectra were then used to express every pixel in the image through a least-squares minimized linear combination providing continuous interpolation between the components across spatially varying features, e.g., bonded to unbonded transition regions. Fitting the component spectra to the thermal model, thermal properties for each K cluster are extracted and then distributed according to the weighting established by the regressed linear combination. Thermophysical property maps are then constructed and capture significant variation in bond quality over 25 μm length scales. The use of K-means clustering to achieve these thermal property maps results in a 74-fold speed improvement over explicit fitting of every pixel.

36 MATERIALS SCIENCE↗

Single Degree-of-Freedom Modeling of SLS Liquid Hydrogen Pre-Valve Flow Guide to Enable Rapid Transient Analysis

A unique single degree-of-freedom approximation technique has been developed to enable rapid application of a temporally-defined multi-spectral semi-narrow-band loading for generation of realistic stress/cycle values compared to a resonant analysis. The technique uses the harmonic analysis at resonance of a high-fidelity finite element model to produce a transfer function, which is then used to calibrate the response of the SDOF model. A standard numerical ordinary differential equation solver is then used to obtain the temporal response, and its histogram is used in a fatigue/fracture model. This technique is related to other SDOF methods used widely in industry, such as Miles' Equation and the Shock Response Spectra, but it is unique in that it produces a realistic time history of the response. The most obvious error in the process, which is the effect of closely-spaced modes, was also assessed using the parallel application of several SDOF models, and the error is shown to be small. The application of this unique and tractable reduced-order methodology has enabled the SLS program to avoid substantial cost and schedule penalties if a redesign or change of material were required. It has also enabled quick analysis of a number of other structures undergoing the same or similar excitation fields, and quick assessment when the excitation and structural configuration has been altered due to design changes in the system.

Brown, Andrew M.↗

Rapid distortion analysis and direct simulation of compressible homogeneous turbulence at finite Mach number

The effect of rapid mean compression on compressible turbulence at a range of turbulent Mach numbers is investigated. Rapid distortion theory (RDT) and direct numerical simulation results for the case of axial (one-dimensional) compression are used to illustrate the existence of two distinct rapid compression regimes. These regimes are set by the relationships between the timescales of the mean distortion, the turbulence, and the speed of sound. A general RDT formulation is developed and is proposed as a means of improving turbulence models for compressible flows.

Cambon, C.↗

Rapid Distortion Analysis and Direct Simulation of Compressible Homogeneous Turbulence at Finite Mach Number

The effect of rapid mean compression on compressible turbulence at a range of turbulent Mach numbers is investigated. Rapid dist'ortion theory (RDT) and direct numerical simulation results for the case of axial (one-dimensional) compression are used to illustrate the existence of two distinct rapid compression regimes. These regimes - the nearly solenoidal and the 'pressure-released' - are defined by a single parameter involving the timescales of the mean distortion, the turbulence, and the speed of sound. A general RDT formulation is developed and is proposed as a means of improving turbulence models for compressible flows. In contrast to the well-documented observation that 'compressibility' (measured, for example, by the turbulent Mach number) is often associated with a decrease in the growth rate of turbulent kinetic energy, we find that under rapid distortion compressibility can produce an amplification of the kinetic energy growth rate. We also find that as the compressibility increases, the magnitude of the pressure-dilation correlation increases, in absolute terms, but its relative importance decreases compared to the magnitude of the kinetic energy production.

Cambon, C.↗

Statistical Methods for Rapid Aerothermal Analysis and Design Technology

The cost and safety goals for NASA's next generation of reusable launch vehicle (RLV) will require that rapid high-fidelity aerothermodynamic design tools be used early in the design cycle. To meet these requirements, it is desirable to establish statistical models that quantify and improve the accuracy, extend the applicability, and enable combined analyses using existing prediction tools. The research work was focused on establishing the suitable mathematical/statistical models for these purposes. It is anticipated that the resulting models can be incorporated into a software tool to provide rapid, variable-fidelity, aerothermal environments to predict heating along an arbitrary trajectory. This work will support development of an integrated design tool to perform automated thermal protection system (TPS) sizing and material selection.

Morgan, Carolyn↗

Statistical Methods for Rapid Aerothermal Analysis and Design Technology: Validation

The cost and safety goals for NASA s next generation of reusable launch vehicle (RLV) will require that rapid high-fidelity aerothermodynamic design tools be used early in the design cycle. To meet these requirements, it is desirable to identify adequate statistical models that quantify and improve the accuracy, extend the applicability, and enable combined analyses using existing prediction tools. The initial research work focused on establishing suitable candidate models for these purposes. The second phase is focused on assessing the performance of these models to accurately predict the heat rate for a given candidate data set. This validation work compared models and methods that may be useful in predicting the heat rate.

DePriest, Douglas↗

Rapid Quantification of 237 U Specific Activity for Nuclear Forensics

In the event of an unattributed nuclear explosion, rapid assessment of the short-lived uranium isotope activity and mass can provide valuable information for subsequent forensic analysis. Rapid analysis in the field is enabled by using microfluidic chemistry and deployable instrumentation. Here, this work presents a flow chemistry system, controlled in LabVIEW, that integrates three functionalities: (1) selective extraction of uranium from the sample matrix via a 3D-printed supported liquid membrane module; (2) UV–visible absorbance spectrophotometry to measure the total uranium concentration in the strip flow; and (3) a portable CdTe γ-ray spectrometer coupled to a 3D-printed flow cell to measure 237 U activity concentration in the strip solution. The system was calibrated using standard solutions, and its functionality was demonstrated using a solution of depleted uranium spiked with 237 U. Uranium concentrations of 40–5000 μg/mL were directly quantified online using a 100 mm optical flow cell, while concentrations of 0.5–10 μg/mL were quantified online using a colorimetric reagent. The mass concentration measurement takes approximately 60 min while the activity concentration via γ-ray spectrometry varies depending on the activity of 237 U, with 1 kBq/mL requiring about 30 min of acquisition time to obtain <10% uncertainty at 1σ. This platform provides a fieldable approach for quantifying uranium mass and radioactivity relevant to postdetonation nuclear debris.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rapid correlation analysis in a group of motions and homogeneous scale transforms of the plane (M(2)xR sub +)

A method is proposed for picking out a given image, in a plane, irrespective of translations, rotations, and homogeneous scale transforms of the plane. The correlation integral is calculated, using the method of abstract harmonic analysis. In this case, and also for groups of translations, it is possible to carry out the calculations using the rapid Fourier transform. The latter fact makes it possible to substantially reduce the number of computer operations for calculating the correlation integral, as compared with direct methods.

Tkhabisimov, D. K.↗

New capabilities for rapid depletion analysis of pebble-bed reactors in SCALE

The SCALE Leap-In for Cores at Equilibrium (SLICE) method leverages capabilities available in the SCALE modeling and simulation suite to facilitate rapid estimation of equilibrium core inventories for flowing-pebble reactor systems in support of a variety of fuel cycle applications. New capabilities that compliment the SLICE method have been developed for the ORIGAMI interface to ORIGEN in SCALE to facilitate rapid depletion calculations for flowing-pebble systems. New features include a more generalized and flexible means of specifying interpolation dimensions, the ability to evaluate pebbles moving through user-defined “axial zones” in each of the pebble’s multiple passes through the core, and the treatment of differential velocities across radial channels (representing both pebble-to-pebble and wall-to-pebble friction effects). ORIGAMI thus provides an efficient user interface to define a pebble’s path and irradiation histories of its multiple passes through the core to calculate the pebble’s time-dependent inventories, which can be useful in various applications domains such as safeguards, criticality safety, and disposal analyses. The consistency of new ORIGAMI approach was verified against the solution obtained using the SLICE method with ORIGEN-ARP, showing excellent agreement.

Skutnik, Steven E. [Oak Ridge National Laboratory ↗

Aerodynamic Properties Analysis of Rapid Prototyped Models Versus Conventional Machined Models

Initial studies of the aerodynamic characteristics of proposed launch vehicles can be made more accurately if lower cost, high fidelity aerodynamic models are available for wind tunnel testing early in the design phase. This paper discusses the results of a study undertaken at NASA's Marshall Space Flight Center to determine if four rapid prototyping methods using a variety of materials are suitable for the design and manufacturing of high speed wind tunnel models in direct testing applications. It also gives an analysis of whether these materials and processes are of sufficient strength and fidelity to withstand the testing environment. In addition to test data, costs and turn-around times for the various models are given. Based on the results of this study, it can be concluded that rapid prototyping models show promise in limited direct application for preliminary aerodynamic development studies at subsonic, transonic, and supersonic speeds.

Springer, A.↗

Study of Unsteady, Sphere-Driven, Shock-Induced Combustion for Application to Hypervelocity Airbreathing Propulsion

A premixed, shock-induced combustion engine has been proposed in the past as a viable option for operating in the Mach 10 to 15 range in a single stage to orbit vehicle. In this approach, a shock is used to initiate combustion in a premixed fuel/air mixture. Apparent advantages over a conventional scramjet engine include a shorter combustor that, in turn, results in reduced weight and heating loads. There are a number of technical challenges that must be understood and resolved for a practical system: premixing of fuel and air upstream of the combustor without premature combustion, understanding and control of instabilities of the shock-induced combustion front, ability to produce sufficient thrust, and the ability to operate over a range of Mach numbers. This study evaluated the stability of the shock-induced combustion front in a model problem of a sphere traveling in a fuel/air mixture at high Mach numbers. A new, rapid analysis method was developed and applied to study such flows. In this method the axisymmetric, body-centric Navier-Stokes equations were expanded about the stagnation streamline of a sphere using the local similarity hypothesis in order to reduce the axisymmetric equations to a quasi-1D set of equations. These reduced sets of equations were solved in the stagnation region for a number of flow conditions in a premixed, hydrogen/air mixture. Predictions from the quasi-1D analysis showed very similar stable or unstable behavior of the shock-induced combustion front as compared to experimental studies and higher-fidelity computational results. This rapid analysis tool could be used in parametric studies to investigate effects of fuel rich/lean mixtures, non-uniformity in mixing, contaminants in the mixture, and different chemistry models.

Axdahl, Erik↗

Singleplex, multiplex and pooled sample real-time RT-PCR assays for detection of SARS-CoV-2 in an occupational medicine setting

Abstract For workplaces which cannot operate as telework or remotely, there is a critical need for routine occupational SARS-CoV-2 diagnostic testing. Although diagnostic tests including the CDC 2019-Novel Coronavirus (2019-nCoV) Real-Time RT-PCR Diagnostic Panel (CDC Diagnostic Panel) (EUA200001) were made available early in the pandemic, resource scarcity and high demand for reagents and equipment necessitated priority of symptomatic patients. There is a clearly defined need for flexible testing methodologies and strategies with rapid turnaround of results for (1) symptomatic, (2) asymptomatic with high-risk exposures and (3) asymptomatic populations without preexisting conditions for routine screening to address the needs of an on-site work force. We developed a distinct SARS-CoV-2 diagnostic assay based on the original CDC Diagnostic Panel (EUA200001), yet, with minimum overlap for currently employed reagents to eliminate direct competition for limited resources. As the pandemic progressed with testing loads increasing, we modified the assay to include 5-sample pooling and amplicon target multiplexing. Analytical sensitivity of the pooled and multiplexed assays was rigorously tested with contrived positive samples in realistic patient backgrounds. Assay performance was determined with clinical samples previously assessed with an FDA authorized assay. Throughout the pandemic we successfully tested symptomatic, known contact and travelers within our occupational population with a ~ 24–48-h turnaround time to limit the spread of COVID-19 in the workplace. Our singleplex assay had a detection limit of 31.25 copies per reaction. The three-color multiplexed assay maintained similar sensitivity to the singleplex assay, while tripling the throughput. The pooling assay further increased the throughput to five-fold the singleplex assay, albeit with a subtle loss of sensitivity. We subsequently developed a hybrid ‘multiplex-pooled’ strategy to testing to address the need for both rapid analysis of samples from personnel at high risk of COVID infection and routine screening. Herein, our SARS-CoV-2 assays specifically address the needs of occupational healthcare for both rapid analysis of personnel at high-risk of infection and routine screening that is essential for controlling COVID-19 disease transmission. In addition to SARS-CoV-2 and COVID-19, this work demonstrates successful flexible assays developments and deployments with implications for emerging highly transmissible diseases and future pandemics.

60 APPLIED LIFE SCIENCES↗