Search NASA⌕ Search

SEARCH · Search NASA

Results for “reference electrode”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Use of platinum electrodes for the electrochemical detection of bacteria

Platinum electrodes with surface area ratios of four to one were used to detect and enumerate a variety of gram-positive and gram-negative organisms. Linear relationships were established between inoculum size and detection time. End points for platinum electrodes were similar to those obtained with a platinum-reference electrode combination. Shape of the overall response curves and length of detection times for gram-positive organisms were markedly different than those for the majority of gram-negative species. Platinum electrodes are better than the platinum-reference electrode combination because of cost, ease of handling, and clearer definition of the end point.

Wilkins, J. R.↗

The Influence of Water Vapor on the Electrochemical Shift of an Ionic Liquid Measured by Ambient Pressure X-ray Photoelectron Spectroscopy

Ionic liquids (ILs) are considered to be one of the steppingstones to fabricate next generation electrochemical devices given their unique physical and chemical properties. The addition of water to ILs significantly impact electrochemical related properties including viscosity, density, conductivity, and electrochemical window. Here, we utilize ambient pressure X-ray photoelectron spectroscopy (APXPS) to examine the impact of water on values of the electrochemical shift (S), which is determined by measuring changes in binding energy shifts as a function of an external bias. APXPS spectra of C 1s, O 1s and N 1s regions are examined for the IL 1-butyl-3-methylimidazolium acetate, [C 4 mim][OAc], at the IL/gas interface as a function of both water vapor pressure and external bias. Results reveal that in the absence of water vapor there is an IL ohmic drop between the working electrode and quasi reference electrode, giving rise to chemical specific S values of less than one. Upon introducing water vapor, S values approach one as a function of increasing water vapor pressure, indicating a decrease in the IL ohmic drop as the IL/water mixture becomes more conductive and the potential drop is driven by the electric double layer at the electrode/IL interface.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Chlorination of uranium metal in molten NaCl-CaCl 2 via bubbling HCl

Molten chloride salt fast reactors (MCFRs) will require UCl 3 dissolved in molten salt mixtures as fuel for nuclear fission. For infusing the salt with UCl 3 , bubbling HCl into NaCl-CaCl 2 in contact with U metal was investigated. The reaction was run up to 9 h and yielded U concentration up to 0.652 wt.%. Open circuit potential between a W electrode and Ag/AgCl reference electrode yielded a potential consistent with uranium existing as U(III) in the salt. Furthermore, this demonstrates that HCl can be a very effective chlorinating agent to infuse MCFR fuel with UCl 3 starting from U metal.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Photoelectrochemically Self Improving Si/GaN Photocathode: Figure 1d Raw Data

Fig1d results were obtained using a 3-electrode configuration with IrOx as the counter electrode and saturated calomel electrode as the reference electrode. Two Si/GaN photocathodes were compared. Sample #1 (named as S#1) was the as-received sample, and sample #2 (named as S#2) was CA tested for 4 hours under same testing conditions described in Fig.1a. The PEC performance (J-V curve) was recorded for both samples. Then a photodeposition of Pt was performed on both samples, each loading time was set to be 5 minutes, then the J-V curve was recorded to track the changes of the performance. The Pt photodeposition was stopped until the J-V curve won't shift (the maximum onset potential was achieved). The results show that, S#1 needs at least 20 minutes of Pt photodeposition to achieve its best PEC performance while S#2, which is after CA testing, only needs 5 minutes of Pt photodeposition to achieve its best PEC performance.

photocathode↗

Electrochemical amperometric gas sensors for environmental monitoring and control

Theoretical considerations and experimental results regarding a unique class of vapor sensors are presented, and the sensors are compared to semiconductor-based sensors. The electrochemical sensors are based on nonaquaeous electrolytes, and gas-detection selectivity achieved by applying a known potential to the sensing electrode using a reference electrode and a counter electrode. Results are given regarding the detection of oxygen and carbon dioxide using one cell, the detection of 3-percent carbon dioxide in nitrogen, and the detection of carbon dioxide in air at percentages ranging from 3 to 6. The sensors are found to be effective in the detection of toxic chemical species including CO, NO2, and formaldehyde; the sensors are further found to require minimal power, operate over long periods of time, and function over a wide temperature range.

Venkatasetty, H. V.↗

Fabricating porous silicon carbide

The formation of porous SiC occurs under electrochemical anodization. A sample of SiC is contacted electrically with nickel and placed into an electrochemical cell which cell includes a counter electrode and a reference electrode. The sample is encapsulated so that only a bare semiconductor surface is exposed. The electrochemical cell is filled with an HF electrolyte which dissolves the SiC electrochemically. A potential is applied to the semiconductor and UV light illuminates the surface of the semiconductor. By controlling the light intensity, the potential and the doping level, a porous layer is formed in the semiconductor and thus one produces porous SiC.

Shor, Joseph S.↗

Detecting the presence of microorganisms

The presence of microorganisms in a sample is determined by culturing microorganisms in a growth medium which is in contact with a measuring electrode and a reference electrode and detecting a change in potential between the electrodes caused by the presence of the microorganisms in the medium with a high impedance potentiometer.

Wilkins, Judd R.↗

Microbial sensor system for monitoring and imaging of an environment

A microbial sensor, microbial sensing system, and method that can be used to determine the chemical environment of unsaturated soils, rhizosphere, and/or plants are disclosed. The microbial sensing system can be used for monitoring the health of plants including nutrients, salinity, contaminants, chemicals (pesticides, herbicides) and diseases. A microbial sensing system can include one or more indicator electrodes and a reference electrode. The microbial sensing system can include a signal acquisition and/or communication module to allow the real-time collection of data from field deployments and laboratory investigations.

Burge, Scott R.↗

Redox Potential of Intermittently Wet Soil, Old Woman Creek National Estuarine Research Reserve, Huron, OH, 2023-05-10 to 2023-12-15

This dataset contains collected reduction-oxidation (redox) potential measurements of the underlying soil at various depths within a wetland, referred to as The Cove, at Old Woman Creek Estuarine Research Reserve in Huron, OH. Redox potential was measured in the sediments of a coastal wetland to assess how redox potential varies over time with changes in hydrological events. Measurements were collected by Campbell Scientific CR1000X dataloggers paired with a PaleoTerra redox probe and reference electrodes. Measurements were collected at 3 different locations within The Cove at multiple depths into the underlying soil of the wetland and were collected every 10 minutes. The Redox_Datafile.csv contains the recorded measurements of the redox probes, and the RefElecDataFile.csv contains the background-noise measurements collected by the reference electrodes. Redox_InstallMethods describes the installation methods of the datalogger and associated probes.

54 ENVIRONMENTAL SCIENCES↗

Double ChemFET for the In-Line Monitoring of Silver Dosing in Potable Water Systems

With NASA Advanced Exploration Systems (AES) Life Support Systems (LSS) baselining ionic silver (Ag+) as the biocide of choice, development in silver monitoring technologies becomes necessary to monitor and control Ag+ release. Ion-selctive field effect transistors (ISFETs) and chemically-sensitive field effect transistors (ChemFETs) are capable of selective detection of Ag+ with reversible and low detection limit responses. However, one major hurdle to ChemFET technologies is the requirement of a reference electrode, which can leak its fill solution into the potable water system and is prone to drift requiring frequent calibration. To circumvent this issue, we are developing a double chemically-sensitive field effect transistor (dChemFET). The dChemFET uses a second ChemFET to selectively monitor the counter ion and serves in place of the reference electrode. We report our work in developing the dChemFET, starting with the development of the Ag+ and NO3- ion selective memberanes (ISMs) to be used in the ChemFETs. The Ag+ ISM has a detection range of 50-105 ppb . The counter ion ISM, NO3- ISM, has shown a detection range of 400-105 ppb. NO3- ISMs are limited in detecting at lower ppb levels required for the dChemFET application on the potable water system. In response to this issue, we also report our studies in using the Ag+ ISM to measure deionized (DI) water as a reference measurement to be implemented in-line before the Ag+ is dosed.

Lance Dean Delzeit↗

Double ChemFET for the In-Line Monitoring of Silver Dosing in Potable Water Systems

With NASA Advanced Exploration Systems (AES) Life Support Systems (LSS)baselining ionic silver (Ag+) as the biocide of choice, development in silver monitoring technologies becomes necessary to monitor and control Ag+ release. Ion-selective field effect transistors (ISFETs) and chemically-sensitive field effect transistors (ChemFETs) are capable of selective detection of Ag+ with reversible and low detection limit responses. However, one major hurdle to ChemFET technologies is the requirement of a reference electrode, which can leak its fill solution into the potable water system and is prone to drift requiring frequent calibration. To circumvent this issue, a double chemically-sensitive field effect transistor (dChemFET) is proposed. The dChemFET uses a second ChemFET to selectively monitor the counter ion and serves in place of the reference electrode. This work reports on the development of the dChemFET, starting with the development of the Ag+ andNO3- ion selective membranes (ISMs) to be used in the ChemFETs. The Ag+ ISM was tested in 50-105 ppb Ag+ and showed linear, sub-Nernstian response. The NO3- ISM was tested in50-500 ppb silver ion equivalents of nitrate ion (Ag+ equiv. of NO3-) and shows linear, sub-Nernstian response as well . However, the Ag+ and NO3- ISMs face significant challenges in terms of drift that obstruct its application for long-term monitoring, but it can serve as a starting point for demonstrating the dChemFET proof of concept.

John Abdou↗

Microbial potentiometric sensor: A new approach to longstanding challenges

The underlying hypothesis of this study is that simple potentiometric measurements between sensing electrodes and a shared reference electrode - Microbial Potentiometric Sesnor (MPS) system - can be employed in a long-term, continuous mode of operation to resolve the spatial and temporal changes in environmental systems. To address the hypothesis, (1) a conceptual description of the MPS system and its postulated principle of operation are provided; (2) the MPS system performance is documented under controlled laboratory conditions; and (3) the capabilities of the MPS system are documented under quiescent and dynamic field condition. In a laboratory setting, the variability among different MPS signals was insignificant confirming the postulated high accuracy and reproducibility of the sensor performance. It also demonstrated statistically significant correlations with dissolved oxygen (DO) and oxidation-reduction potential (ORP) sensors, while showing capabilities of operating under anoxic and anaerobic conditions. Regardless of their locations in the model wetland system, three MPS sensors functioned without interruption and cleaning for a period >2 years, and thus demonstrating long-term durability of the MPS technology. In real batch-wastewater treatment facility, the deployed MPS system signals were able to describe the organic carbon trends and correlate with each treatment phase in a cycle. Data reproducibility and reliability exceeded the expectations better describing the carbon treatment levels than the DO and ORP sensors (p < 4.4 × 10 –162 vs phase adjusted p < 3.0 × 10 –58 ). While MPS signals correlate with specific parameters that describe the local process or environments, it is more prudent to employ both the magnitude and pattern of a composite signal like the MPS signal describe the change to reflect any shift in the local environment. Finally, when compared to a baseline pattern, this change in signal magnitude and pattern reveals important information that can be employed to tailor and optimize any condition or process which involves microorganisms.

47 OTHER INSTRUMENTATION↗

Determination of Kinetic Properties of Ni(II) Ions in Molten LiF-NaF-KF via Voltammetry

Kinetic properties of Ni(II) in eutectic LiF-NaF-KF (FLiNaK) molten salt were determined at T = 748–823 K using cyclic voltammetry (CV), square wave voltammetry (SWV), and chronoamperometry (CA) measurements using a glassy C working electrode, Ni(II)/Ni reference electrode, and Ni counter electrode. Reduction of Ni(II) to Ni(s) was determined to be a single step, two-electron transfer process. Diffusivity values were calculated using the Berzins and Delahay equation and semi-integral electroanalysis from the CV measurements as well as using the Cottrell equation from the CA measurements. Diffusivity of Ni(II) in molten FLiNaK at T = 748–823 K was determined to be 3.27 × 10 –7 –3.04 × 10 –6 cm 2 s –1 with an activation energy of 62–104 kJ mol –1 . The estimated kinetic properties varied appreciably among methodologies possibly due to inherent assumptions in theory regarding reversibility and unit activity during Ni metal deposition on the working electrode.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Science Driven Discovery of Nanoparticle Photocatalysts

Photocatalytic water splitting using suspensions of nanoparticle photocatalysts is a promising route to economically sustainable production of green hydrogen. The principal challenge is to develop photocatalysts with overall solar-to-hydrogen conversion efficiency that exceeds 10 percent. In this project we have developed a new platform for investigating candidate materials for photocatalytic water splitting. Our platform consists of patterned Au electrodes and a Ag/AgCl reference electrode on an insulating substrate onto which we disperse nanoparticle photocatalysts. We then cover the substrate with a thin layer of ionogel containing a protic ionic liquid that dissolves water from the ambient. Using this platform we have demonstrated photoelectrochemical activity mapping for single and small clusters of BiVO 4 nanoparticle photocatalysts and correlated these results to their Raman and photoluminescence spectra. The preliminary results suggest a strong correlation for low efficiency nanoparticles, followed by saturation for those with higher activities, indicating that interface reaction or electrolyte transport become the limiting factor. We anticipate that further application of this platform to investigation of candidate photocatalyst materials will provide useful insights into the mechanisms that limit their performance.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Microbial detection method based on sensing molecular hydrogen

A simple method for detecting bacteria, based on the time of hydrogen evolution, was developed and tested against various members of the Enterobacteriaceae group. The test system consisted of (1) two electrodes, platinum and a reference electrode, (2) a buffer amplifier, and (3) a strip-chart recorder. Hydrogen evolution was measured by an increase in voltage in the negative (cathodic) direction. A linear relationship was established between inoculum size and the time hydrogen was detected (lag period). Lag times ranged from 1 h for 1 million cells/ml to 7 h for 1 cell/ml. For each 10-fold decrease in inoculum, length of the lag period increased 60 to 70 min. Based on the linear relationship between inoculum and lag period, these results indicate the potential application of the hydrogen-sensing method for rapidly detecting coliforms and other gas-producing microorganisms in a variety of clinical, food, and other samples.

Wilkins, J. R.↗

Characterization of physiochemical properties of polymeric and electrochemical materials for aerospace flight

Nickel-cadmium rechargeable batteries are a vital and reliable energy storage source for aerospace applications. As the demand for longer life and more reliable space batteries increases, the understanding and solving of cell aging factors and mechanisms become essential. Over the years, many cell designs and manufacturing process changes have been developed and implemented. Cells fabricated with various design features were life cycled in a simulated low-Earth orbit regime. Following the test program, a comprehensive electrochemical analysis of cell components was undertaken to study cell degradation mechanisms. Discharge voltage degradation or voltage plateau has been observed during orbit cycling, but, its cause and explanation have been the subject of much discussion. A Hg/HgO reference electrode was used to monitor the reference versus each electrode potential during the discharge of a cycled cell. The results indicate that the negative electrode was responsible for the voltage plateau. Cell analysis revealed large crystals of cadmium hydroxide on the surface of the negative electrode and throughout the separator.

Rock, M.↗

Examining Effects of Negative to Positive Capacity Ratio in Three-Electrode Lithium-Ion Cells with Layered Oxide Cathode and Si Anode

The negative to positive electrode capacity ratio (N:P) is crucial for lithium-ion cell design because it affects both energy density and long-term performance. Here, the effect of N:P ratio on electrochemical performance has been investigated for NMC 532 /Si cells containing a reference electrode. By monitoring individual electrode potentials, depths of lithiation/delithiation at the anode and cathode could be determined. The superior performance of the higher N:P cell, including greater reversibility, better capacity retention and lower impedance rise, can be attributed to smaller volume changes in the silicon particles during electrochemical cycling.

25 ENERGY STORAGE↗

Electrolytes with Improved Safety Developed for High Specific Energy Li-Ion Cells with Si-Based Anodes

A number of electrolyte formulations that have improved safety characteristics have been developed for use with high capacity silicon-based anodes. To improve the compatibility with Si-based anodes, a number of technical approaches have been employed, including: (1) the use of mono-fluoroethylene carbonate (FEC) in conjunction with, or in lieu of, ethylene carbonate (EC), (2) the use of high proportions of fluorinated co-solvents, (3) the use of vinylene carbonate (VC) to stabilize the Si/C electrode, and (4) the use of lithium bis(oxalato)borate (LiBOB) to improve the compatibility of the electrolyte when Si/C electrodes are used in conjunction with high voltage cathodes. Candidate electrolytes were studied in Li/Si-C and Si-C/ Li(MnNiCo)O2 (NMC) coin cells, as well as in larger Si-C/NMC three-electrode cells equipped with lithium reference electrodes. In summary, many electrolytes that contain triphenyl phosphate (TPP), which is used as a flame retardant additive up to concentrations of 15 volume percent, and possess FEC as a co-solvent have been demonstrated to outperform the all-carbonate baseline electrolytes when evaluated in Si-C/ Li(MnNiCo)O2 cells.

Silicon-Based Anode↗