Search NASA⌕ Search

DOE OSTI · 1764133

Photoelectrochemically Self Improving Si/GaN Photocathode: Figure 1d Raw Data

Abstract

Fig1d results were obtained using a 3-electrode configuration with IrOx as the counter electrode and saturated calomel electrode as the reference electrode. Two Si/GaN photocathodes were compared. Sample #1 (named as S#1) was the as-received sample, and sample #2 (named as S#2) was CA tested for 4 hours under same testing conditions described in Fig.1a. The PEC performance (J-V curve) was recorded for both samples. Then a photodeposition of Pt was performed on both samples, each loading time was set to be 5 minutes, then the J-V curve was recorded to track the changes of the performance. The Pt photodeposition was stopped until the J-V curve won't shift (the maximum onset potential was achieved). The results show that, S#1 needs at least 20 minutes of Pt photodeposition to achieve its best PEC performance while S#2, which is after CA testing, only needs 5 minutes of Pt photodeposition to achieve its best PEC performance.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Zeng, Guosong, Pham, Tuan Anh, Vanka, Srinivas, Liu, Guiji, Song, Chengyu, Cooper, Jason K, Mi, Zetian, Ogitsu, Tadashi, Toma, Francesca. 2021-02-04. Photoelectrochemically Self Improving Si/GaN Photocathode: Figure 1d Raw Data. https://doi.org/10.17025/1764133

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Photoelectrochemically Self Improving Si/GaN Photocathode: Figure 1a Raw Data

10 hours chronoamperometry (CA) testing under 1 sun illumination and constant bias at -0.6 V vs RHE, the corresponding Faradaic efficiency reveals a self-improving nature of GaN, inset: CA testing on bare Si for 5 hours under 1 sun illumination and -0.6 V vs RHE, this bare Si photocathode rapidly drops down to < 0.05 mA/cm2 within an hour. Both CA testing performed in 0.5 M H2SO4 (pH=0.4).

photocathode↗

Photoelectrochemically Self Improving Si/GaN Photocathode: Figure 1c Raw Data

Intermittent chronoamperometry (CA) testing was performed on Si/GaN photocathode in hourly manner. The LSV scan at 0 hour, 1 hour CA, 2 hours CA, 3 hours CA, 4 hours CA, 6 hours CA, 8 hours CA and 10 hours CA were recorded to track the changes of the photoelectrochemica (PEC) performance of the photocathode. The scan range was set to be 0V vs open circuit voltage (Eoc) to -0.7V vs RHE. Test was performed under one sun illumination in 0.5M H2SO4 (pH=0.4).

photocathode↗