Search NASA⌕ Search

SEARCH · Search NASA

Results for “spectral imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Spatio-Spectral Characterization of Multipolar Plasmonic Modes of Au Nanorods via Tip-Enhanced Raman Scattering

Tip-enhanced Raman (TER) spectral images of 4-thiobenzonitrile-coated Au nanorods map the spatial profiles and trace the resonances of dipolar and multipolar plasmonic modes that are characteristic of the imaged particles. For any particular rod, we observe sequential transitions between high-order modes at low frequency shifts and lower-order modes at higher frequencies. We also notice that higher-order modes (up to $m$ = 4) are generally observed for long rods as compared to their shorter analogues, where longitudinal dipolar resonances ($m$ = 1) are observable. In effect, this research adds a new dimension to local optical field mapping via TERS, which we have previously explored. Not only can the magnitudes, vector components, local/nonlocal characters of local optical fields be imaged through molecular TERS, but spatially varying local optical resonances are also direct observables.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

AC Magnetometry Using Nano-ferrofluid Cladded Multimode Interferometric Fiber Optic Sensors for Power Grid Monitoring Applications

The AC magnetic field response of the superparamagnetic nano-ferrofluid is an interplay between the Neel and Brownian relaxation processes and is generally quantified via the susceptibility measurements at high frequencies. The high frequency limit is dictated by these relaxation times which need to be shorter than the time scale of the time varying magnetic field for the nano-ferrofluid to be considered in an equilibrium state at each time instant. Even though the high frequency response of ferrofluid has been extensively investigated for frequencies up to GHz range by non-optical methods, harnessing dynamic response by optical means for AC magnetic field sensing in fiber-optic-based sensors-field remains unexplored. Instead, the incorporation of nano-ferrofluid as sensing materials has been only limited to DC magnetic field sensing, often citing their long response time as a limiting factor to AC field sensing. This work reports the finding of high frequency (up to 15 kHz) AC magnetic field sensing capability of nanomagnetic fluid as the cladding material of a fiber-optic multimode interferometry (MMI) structure optimized for the fourth self-imaging spectral response. The key parameter enabling high frequency response is the short response time (<1 ms) achieved by optimizing both the sensing structure and nano-ferrofluid solution. Focus has been imparted on 60 Hz line-frequency profiles of various current/magnetic fields to test the efficacy of these sensors in metering and monitoring current and current-induced magnetic fields in the electrical power grid systems. The magnetic field sensitivity of 240 mV/Gauss per dBm of transmitted power was achieved for 60 Hz field applied via Helmholtz coil, whereas the 60 Hz AC current sensitivity of 2.83 mV/A was measured due to magnetic field induced by current in a straight conducting wire.

42 ENGINEERING↗

Beyond Optimization: Exploring Novelty Discovery in Autonomous Experiments

Autonomous experiments (AEs) are transforming how scientific research is conducted by integrating artificial intelligence with automated experimental platforms. Current AEs primarily focus on the optimization of a predefined target; while accelerating this goal, such an approach limits the discovery of unexpected or unknown physical phenomena. Here, we introduce a novel framework, INS 2 ANE (Integrated Novelty Score−Strategic Autonomous Non-Smooth Exploration), to enhance the discovery of novel phenomena in autonomous microscopy experimentation. Our method integrates two key components: (1) a novelty scoring system that evaluates the uniqueness of experimental results and (2) a strategic sampling mechanism that promotes exploration of under-sampled regions even if they appear less promising by conventional criteria. We validate this approach on a preacquired data set with a known ground truth comprising of image−spectral pairs. We further implement the process on autonomous scanning probe microscopy experiments. INS 2 ANE significantly increases the diversity of explored phenomena in comparison to conventional optimization routines, enhancing the likelihood of discovering previously unobserved phenomena. These results demonstrate the potential for autonomous microscopy experiments to enhance the scientific discovery by navigating complex experimental spaces to uncover novel phenomena.

Materials↗

A Solvatochromic Near Infrared Fluorophore Sensitive to the Full Amyloid Beta Aggregation Pathway

Alzheimer's disease has long been associated with the aggregation of amyloid beta peptides (Aβ42) into macroscale plaques, although specific neurodegenerative agents have not been definitively identified. Much evidence has pointed to the soluble nanoscale oligomers that form early in the Aβ42 aggregation pathway, but there is little understanding of these structures, their mechanisms of formation, or how they grow into plaques. Here, we show that a solvatochromic fluorophore with near-infrared (NIR) emission can track synthetic Aβ42 aggregation through environment-sensitive spectral shifts from the earliest time points through plaque formation. This azide-functionalized phosphine oxide azetidine rhodol (Phazr-N3) shows large polarity-dependent changes in fluorescence emission, with maxima shifting from 630 nm in toluene to 703 nm in aqueous buffer, and a maximum quantum yield of 62%. Upon induction of Aβ42 aggregation, we observe immediate solvatochromic changes in Phazr-N3 fluorescence, with multiple apparent phases over 12 h, and which culminate before the onset of any major fluorescence changes of conformation-specific aggregation fluorophore thioflavin T. Solution anisotropy measurements show a low micromolar affinity of Phazr-N3 for disordered, free Aβ42 in solution, and real-time measurements are consistent with rapid liquid-liquid phase separation and slow dehydration of the growing aggregate. Spectral imaging of synthetic plaques stained in the presence of live cells and lipid-binding protein albumin shows over 4000-fold Phazr-N3 fluorescence intensity above background under no-wash conditions, and over 100-fold intensity above coplated microglial cells or a large excess of albumin. This use of a solvatochromic probe with structure-independent binding to free Aβ42 offers real-time, minimally invasive insight into the full Aβ42 aggregation pathway.

Wang, Zeming↗

Sub-diffractional cavity modes of terahertz hyperbolic phonon polaritons in tin oxide

Abstract Hyperbolic phonon polaritons have recently attracted considerable attention in nanophotonics mostly due to their intrinsic strong electromagnetic field confinement, ultraslow polariton group velocities, and long lifetimes. Here we introduce tin oxide (SnO 2 ) nanobelts as a photonic platform for the transport of surface and volume phonon polaritons in the mid- to far-infrared frequency range. This report brings a comprehensive description of the polaritonic properties of SnO 2 as a nanometer-sized dielectric and also as an engineered material in the form of a waveguide. By combining accelerator-based IR-THz sources (synchrotron and free-electron laser) with s-SNOM, we employed nanoscale far-infrared hyper-spectral-imaging to uncover a Fabry–Perot cavity mechanism in SnO 2 nanobelts via direct detection of phonon-polariton standing waves. Our experimental findings are accurately supported by notable convergence between theory and numerical simulations. Thus, the SnO 2 is confirmed as a natural hyperbolic material with unique photonic properties essential for future applications involving subdiffractional light traffic and detection in the far-infrared range.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Frequency comb ptychoscopy

Multiheterodyne techniques using frequency combs—radiation sources whose lines are perfectly evenly-spaced—have revolutionized science. By beating sources with the many lines of a comb, their spectra are recovered. Even so, these approaches are fundamentally limited to probing coherent sources, such as lasers. They are unable to measure most spectra that occur in nature. Here we present frequency comb ptychoscopy, a technique that allows for the spectrum of any complex broadband source to be retrieved using a comb. In this approach, the spectrum is reconstructed by unfolding the simultaneous beating of a source with each comb line. We demonstrate this both theoretically and experimentally, at microwave frequencies. This approach can reconstruct the spectrum of nearly any complex source to high resolution, and the speed, resolution, and generality of this technique will allow chip-scale frequency combs to have an impact in a wide swath of new applications, such as remote sensing and passive spectral imaging.

42 ENGINEERING↗

A framework for quantitative analysis of spectral data in two channels

Simultaneous acquisition of emission intensity from two channels in dual-color fluorescence measurements can be used to determine the spectral properties of an emitter. We detail a method to extract quantitative information from dual-color measurements by considering two models: a single spectral component model for peak wavelength determination and a dual spectral component model for relative strength determination. The former model is useful for spectral characterization and establishing heterogeneity within an emitter species, while the latter model is useful for analyzing energy transfer efficiency. Both models are formalized to yield probability distributions that reflect uncertainties due to shot noise. We applied these analysis tools to single-particle measurements of CdSe/CdS quantum dots. Isolated emitters had narrow spectral-intensity distributions that reflected their static emission profiles and fluorescence stability. Small assemblies of mixed donor/acceptor particles exhibited dynamic behavior where emission configuration changes reveal different spectral characteristics due to energy transfer.

36 MATERIALS SCIENCE↗

Kiloparsec-scale AGN outflows and feedback in merger-free galaxies

ABSTRACT Recent observations and simulations have challenged the long-held paradigm that mergers are the dominant mechanism driving the growth of both galaxies and supermassive black holes (SMBH), in favour of non-merger (secular) processes. In this pilot study of merger-free SMBH and galaxy growth, we use Keck Cosmic Web Imager spectral observations to examine four low-redshift (0.043 < z < 0.073) disc-dominated ‘bulgeless’ galaxies hosting luminous active galactic nucleus (AGN), assumed to be merger-free. We detect blueshifted broadened [O iii] emission from outflows in all four sources, which the $\mathrm{[O\, \small {III}]}$/$\rm {H}\beta$ ratios reveal are ionized by the AGN. We calculate outflow rates in the range $0.12{-}0.7~\rm {M}_{\odot }~\rm {yr}^{-1}$, with velocities of $675{-}1710~\rm {km}~\rm {s}^{-1}$, large radial extents of $0.6{-}2.4~\rm {kpc}$, and SMBH accretion rates of $0.02{-}0.07~\rm {M}_{\odot }~\rm {yr}^{-1}$. We find that the outflow rates, kinematics, and energy injection rates are typical of the wider population of low-redshift AGN, and have velocities exceeding the galaxy escape velocity by a factor of ∼30, suggesting that these outflows will have a substantial impact through AGN feedback. Therefore, if both merger-driven and non-merger-driven SMBH growth lead to co-evolution, this suggests that co-evolution is regulated by feedback in both scenarios. Simulations find that bars and spiral arms can drive inflows to galactic centers at rates an order of magnitude larger than the combined SMBH accretion and outflow rates of our four targets. This work therefore provides further evidence that non-merger processes are sufficient to fuel SMBH growth and AGN outflows in disc galaxies.

Smethurst, R. J. (ORCID:0000000164177196)↗

IRIXS Spectrograph: an ultra high-resolution spectrometer for tender RIXS

The IRIXS Spectrograph represents a new design of an ultra-high-resolution resonant inelastic X-ray scattering (RIXS) spectrometer that operates at the Ru L 3 -edge (2840 eV). First proposed in the field of hard X-rays by Shvyd'ko [(2015), Phys. Rev. A, 91, 053817], the X-ray spectrograph uses a combination of laterally graded multilayer mirrors and collimating/dispersing Ge(111) crystals optics in a novel spectral imaging approach to overcome the energy resolution limitation of a traditional Rowland-type spectrometer [Gretarsson et al. (2020), J. Synchrotron Rad. 27, 538–544]. In combination with a dispersionless nested four-bounce high-resolution monochromator design that utilizes Si(111) and Al 2 O 3 (110) crystals, an overall energy resolution better than 35 meV full width at half-maximum has been achieved at the Ru L 3 -edge, in excellent agreement with ray-tracing simulations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

HERMES

HERMES - High-speed Event Retrieval and Management for Enhanced Spectral imaging code. This code is meant to unpack and process neutron imaging data from the TPX3Cam made by Amsterdam Scientific Instruments. The TPX3Cam utilizes the Timepix3 chip in a single photon counting mode of image acquisition. The photon counting data streaming off the TPX3Cam needs to be process and analyzed in order to create final images. Therefore we are developing both python and cpp codes to allow for users of the TPX3Cam to efficiently analyze data and create images.

Long, Alexander↗

Improved Infrared Optical Constants from Pressed Pellets: II. Ellipsometric n and k Values for Ammonium Sulfate with Variability Analysis

Infrared spectral imaging is facilitated via the comparison of spectra recorded in situ to a databank of actual or synthetic infrared reflectance spectra. It has recently been shown that reference spectra corresponding to the many different morphological forms of the same chemical can be generated synthetically using the imaginary, k, and real, n, components of the complex refractive index, n~ = n + ik. One method to obtain the n and k vectors is infrared ellipsometry, which measures the changes in amplitude, tan ?, and phase, ?, of polarized light reflected from the sample both as a function of wavenumber and angle of incidence. The method requires specularly reflected light so best results are usually obtained with polished planar samples of large surface area. Due to the difficulties of obtaining such samples, however, we investigate the possibility of pressing powders of neat materials and obtaining the corresponding optical constants from the pellets. In this paper, variability in the sample pellet and preparation method is investigated, as is variability in the fitting procedure for the derived optical constants. The n/k vectors are derived from the measured ellipsometric parameters, tan ? and ?, as they are fit by an oscillator model which yield n(?) and k(?) vectors as a function of wavenumber, ?. Construction of the oscillator model is not automatic and depends on significant input from the analyst as well as the sample’s physical characteristics. For the pellet pressing, the experimental variability was found to be minimized for size-selected powdered samples as gauged by the minimal variance in ? and ? for three different pellets; similarly, the analytical precision for multiple measurements of the same pellet was also quite good, suggesting that a pressed pellet is a viable sample preparation method. The greatest variability came in the analytic fitting procedure with differences up to 20% arising from four different fits to the same data set. The final ellipsometric n/k data are compared to literature values obtained from crystalline (NH4)2SO4 samples as well as single-angle reflectance measurements that also used pressed pellets. Comparison with the previous literature values shows generally good agreement although higher k-values are observed for the independent sets of data derived from pressed pellets. These data are suggested as an improved set of optical constants for (NH4)2SO4.

optical constants, ellipsometry, ammonium sulfate,↗

Plasma Emission, Wave Speeds, and Temperatures of Laser-Supported Plasmas in Air

A study of the generation and subsequent expansion of plasmas using a single beam (532 nm) from the second harmonic generator of a Q-switched Nd:YAG laser is described. The plasmas in air are studied using an intensified charge-coupled device camera over periods of 1000 ns following the laser pulses. The plasma experimental results are interpreted in terms of wave speeds and plasma temperatures. Energy balance equations are considered to estimate the plasma temperatures and the laser-supported radiation (LSR) and the laser-supported detonation (LSD) wave speeds. Within 1000 ns observation time, the circular spectral images turn elliptical because of plasma expansion toward the laser beam. The plasma expansion increases with increasing laser irradiance. A laser irradiance range of [Formula: see text] yields LSR wave speeds between 45 and 170 km/s and LSD wave speeds of 90–130 km/s. The measured wave speeds are compared with the LSR and the LSR wave speed models. The plasma temperatures are between 90,000 and 120,000 K at 15 ns after the laser pulse based on measured emission spectra and are between 640,000 and 760,000 K at 3 ns based on the LSR model.

Engineering↗

Biological insights from multi-omics analysis strategies: Complex pleotropic effects associated with autophagy

Research strategies that combine molecular data from multiple levels of genome expression (i.e., multi-omics data), often referred to as a systems biology strategy, has been advocated as a route to discovering gene functions. In this study we conducted an evaluation of this strategy by combining lipidomics, metabolite mass-spectral imaging and transcriptomics data from leaves and roots in response to mutations in two AuTophaGy-related ( ATG ) genes of Arabidopsis . Autophagy is an essential cellular process that degrades and recycles macromolecules and organelles, and this process is blocked in the atg7 and atg9 mutants that were the focus of this study. Specifically, we quantified abundances of ~100 lipids and imaged the cellular locations of ~15 lipid molecular species and the relative abundance of ~26,000 transcripts from leaf and root tissues of WT, atg7 and atg9 mutant plants, grown either in normal (nitrogen-replete) and autophagy-inducing conditions (nitrogen-deficient). The multi-omics data enabled detailed molecular depiction of the effect of each mutation, and a comprehensive physiological model to explain the consequence of these genetic and environmental changes in autophagy is greatly facilitated by the a priori knowledge of the exact biochemical function of the ATG7 and ATG9 proteins.

59 BASIC BIOLOGICAL SCIENCES↗

Spectral and polarization based imaging in deep-ultraviolet excited photoelectron microscopy

Using photoelectron emission microscopy, nanoscale spectral imaging of atomically thin MoS2 buried between Al2O3 and SiO2 is achieved by monitoring the wavelength and polarization dependence of the photoelectron signal excited by deep-ultraviolet light. Although photons induce the photoemission, images can exhibit resolutions below the photon wavelength as electrons sense the response. To validate this concept, the dependence of photoemission yield on the wavelength and polarization of the exciting light was first measured and then compared to simulations of the optical response quantified with classical optical theory. A close correlation between experiment and theory indicates that photoemission probes the optical interaction of UV-light with the material stack directly. The utility of this probe is then demonstrated when both the spectral and polarization dependence of photoemission observe spatial variation consistent with grains and defects in buried MoS2. Taken together, these new modalities of photoelectron microscopy allow mapping of optical property variation at length scales unobtainable with conventional light-based microscopy.

Beechem, Thomas E. (ORCID:0000000275360719)↗

Ghost-imaging-enhanced noninvasive spectral characterization of stochastic x-ray free-electron-laser pulses

Abstract High-intensity ultrashort X-ray free-electron laser (XFEL) pulses are revolutionizing the study of fundamental nonlinear x-ray matter interactions and coupled electronic and nuclear dynamics. To fully exploit the potential of this powerful tool for advanced x-ray spectroscopies, a noninvasive spectral characterization of incident stochastic XFEL pulses with high resolution is a key requirement. Here we present a methodology that combines high-acceptance angle-resolved photoelectron time-of-flight spectroscopy and ghost imaging to enhance the quality of spectral characterization of x-ray free-electron laser pulses. Implementation of this noninvasive high-resolution x-ray diagnostic can greatly benefit the ultrafast x-ray spectroscopy community by functioning as a transparent beamsplitter for applications such as transient absorption spectroscopy in averaging mode as well as covariance-based x-ray nonlinear spectroscopies in single-shot mode where the shot-to-shot fluctuations inherent to a self-amplified spontaneous emission (SASE) XFEL pulse are a powerful asset.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Excitation spectral microscopy for highly multiplexed fluorescence imaging and quantitative biosensing

The multiplexing capability of fluorescence microscopy is severely limited by the broad fluorescence spectral width. Spectral imaging offers potential solutions, yet typical approaches to disperse the local emission spectra notably impede the attainable throughput. Here we show that using a single, fixed fluorescence emission detection band, through frame-synchronized fast scanning of the excitation wavelength from a white lamp via an acousto-optic tunable filter, up to six subcellular targets, labeled by common fluorophores of substantial spectral overlap, can be simultaneously imaged in live cells with low (~1%) crosstalks and high temporal resolutions (down to ~10 ms). The demonstrated capability to quantify the abundances of different fluorophores in the same sample through unmixing the excitation spectra next enables us to devise novel, quantitative imaging schemes for both bi-state and Förster resonance energy transfer fluorescent biosensors in live cells. We thus achieve high sensitivities and spatiotemporal resolutions in quantifying the mitochondrial matrix pH and intracellular macromolecular crowding, and further demonstrate, for the first time, the multiplexing of absolute pH imaging with three additional target organelles/proteins to elucidate the complex, Parkin-mediated mitophagy pathway. Together, excitation spectral microscopy provides exceptional opportunities for highly multiplexed fluorescence imaging. The prospect of acquiring fast spectral images without the need for fluorescence dispersion or care for the spectral response of the detector offers tremendous potential.

59 BASIC BIOLOGICAL SCIENCES↗