Search NASASearch

SEARCH · Search NASA

Results for “stack”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Unidirectional ray polaritons in twisted asymmetric stacks

Abstract The vast repository of van der Waals (vdW) materials supporting polaritons offers numerous possibilities to tailor electromagnetic waves at the nanoscale. The development of twistoptics—the modulation of the optical properties by twisting stacks of vdW materials—enables directional propagation of phonon polaritons (PhPs) along a single spatial direction, known as canalization. Here we demonstrate a complementary type of directional propagation of polaritons by reporting the visualization of unidirectional ray polaritons (URPs). They arise naturally in twisted hyperbolic stacks with very different thicknesses of their constituents, demonstrated for homostructures of$$\alpha$$ α -MoO 3 and heterostructures of$$\alpha$$ α -MoO 3 and$$\beta$$ β -Ga 2 O 3 . Importantly, their ray-like propagation, characterized by large momenta and constant phase, is tunable by both the twist angle and the illumination frequency. Apart from their fundamental importance, our findings introduce twisted asymmetric stacks as efficient platforms for nanoscale directional polariton propagation, opening the door for applications in nanoimaging, (bio)-sensing, or polaritonic thermal management.

Science & Technology - Other Topics

Stacking polymorphism of PtSe 2 : its implication to layer-dependent metal-insulator transitions

Using diffusion Monte Carlo (DMC) and density functional theory (DFT) calculations, we examine the structural stability and interlayer binding properties of PtSe 2 . Our DMC study reveals that AA and AB-r bilayer stacking modes are nearly degenerate, highlighting the significant role of interlayer hybridization in offsetting the energy cost due to larger interlayer separations in the AB-r mode. Additionally, our DMC-benchmarked DFT calculations with the r 2 SCAN+rVV10 functional uncover pronounced stacking polymorphism in few-layer PtSe 2 , driven by degenerate AA and AB-r interfaces, which leads to substantial band gap variations across different stacking configurations. This polymorphism, along with selenium vacancies, influences a layer-dependent metal-insulator transition observed in few-layer PtSe 2 . Our findings emphasize the importance of both van der Waals interactions and interlayer hybridization in determining the phase stability and electronic properties of PtSe 2 , advancing our understanding of its fundamental properties and refining theoretical models for practical applications in nanoelectronic devices.

Electronic materials

Masses of Sunyaev-Zel’dovich galaxy clusters detected by the Atacama Cosmology Telescope: Stacked lensing measurements with Subaru HSC year 3 data

We present a stacked lensing analysis of 96 galaxy clusters selected by the thermal Sunyaev-Zel’dovich (SZ) effect in maps of the cosmic microwave background (CMB). We select foreground galaxy clusters with a 5 σ -level SZ threshold in CMB observations from the Atacama Cosmology Telescope, while we define background source galaxies for the lensing analysis with secure photometric redshift cuts in Year 3 data of the Subaru Hyper Suprime Cam survey. We detect the stacked lensing signal in the range of 0.1 < R [ h - 1 Mpc ] < 100 in each of three cluster redshift bins, 0.092 < z ≤ 0.445 , 0.445 < z ≤ 0.695 , and 0.695 < z ≤ 1.180 , with 32 galaxy clusters in each bin. The cumulative signal-to-noise ratios of the lensing signal are 14.6, 12.0, and 6.6, respectively. Using a halo-based forward model, we then constrain statistical relationships between the mass inferred from the SZ observation (i.e. SZ mass) and the total mass derived from our stacked lensing measurements. At the average SZ mass in the cluster sample ( 2.1 - 2.4 × 10 14 h - 1 M ⊙ ), our likelihood analysis shows that the average total mass differs from the SZ counterpart by a factor of 1.3 ± 0.2 , 1.6 ± 0.2 , and 1.6 ± 0.3 (68%) in the aforementioned redshift ranges, respectively. Our limits are consistent with previous lensing measurements, and we find that the cluster modeling choices can introduce a 1 σ -level difference in our parameter inferences.

79 ASTRONOMY AND ASTROPHYSICS

System-Level Efficiency Study of Modular DC/DC and Fuel Cell Stack Series–Parallel Configurations

This paper presents a system-level efficiency study of modular DC/DC converter and fuel cell stack configurations under series, parallel, and series–parallel connections. The investigation considers selected DC/DC converter topologies, including isolated and non-isolated architectures, boost, non-inverting buck-boost, and resonant converters, integrated with commercially available fuel cell stacks, including the Accelera FCE150, Ballard FCgen-HPS, and Toyota TFCM2. DC/DC converter modules are evaluated in modular configurations rated at 60 kW and 90 kW and two distinct output voltage ranges, specifically 580–730V and 780–930V, examining how different interconnection schemes impact overall system efficiency. The converters are evaluated under full load (100%), partial load (66%), and light load (33%) conditions, providing a comprehensive assessment of efficiency and operational characteristics across varying power demands. Approximately two-thousand efficiency data points are obtained from laboratory prototype–level component measurements and validated design evaluations across multiple converter topologies, modular configurations, voltage ranges, and load conditions, providing a robust dataset for comparative system-level efficiency analysis. The results highlight the effects of modularity and topology selection on system-level efficiency, offering a “playbook” framework for designers to select appropriate DC/DC converter arrangements and fuel cell stack connections for series, parallel, or hybrid configurations based on efficiency considerations.

DC/DC

BIL High Speed Fuel Cell Stack Manufacturing

General Motors LLC (GM) was awarded a project to develop and implement technologies for manufacturing 20,000 units of Fuel Cell Stacks per year on two shifts per day basis. GM leveraged prior in-house expertise in designing the Fuel Cells, deploying the manufacturing process steps in the laboratory environment as well as the deployment in the industrial environment on a smaller scale. The project focus was to design, build, and deploy a manufacturing line consisting of an anode and cathode electrode processing, unitized electrode assembly, fuel cell stacking, compression, testing, and final assembly of the fuel cell stack. The project was terminated in the first budget period.

08 HYDROGEN

Evaluation of a 5kW Solid Oxide Electrolysis Cell Stack

Solid oxide electrolysis cells (SOECs) are a developing technology for hydrogen production. They are promising due to their utilization of thermal energy to reduce their electricity consumption. The Department of Energy (DOE) has set goals to reduce the price per kilogram of hydrogen, and Idaho National Laboratory (INL) is conducting research to develop and demonstrate advanced methods and technologies to achieve making hydrogen a more affordable, efficient, and sustainable energy source. In this project, INL is collaborating with a vendor to evaluate and validate the design of a 5kW SOEC stack. The test aims to demonstrate a safe startup, operation, and shutdown on INL’s 5kW test stand, providing third-party validation in a different environment. A successful 50-hour test with stable hydrogen production will pave the way for a subsequent 1000-hour test. This project emphasized learning about electrolysis and the various support systems, referred to as balance of plant (BOP) equipment. These systems required modification while swapping to the vendor 5kW SOEC stack, most prominently the furnace door design and the controls system. It also included gaining skills in creating computer-aided design (CAD) drawings for the new door while using available materials and ensuring it met high-temperature requirements. Upon completion of modifications to the test stand, the SOEC will be test-fitted with respective wiring and piping. Instrumentation and piping will be checked for leaks and quality. This must be completed before the vendor’s engineers arrive to observe the test plan, startup, and a collection of 50 hours of data. The vendor’s engineers will ensure their stack performed sufficiently in the 50-hour test to enable the progression to a 1000-hour test.

08 - HYDROGEN

XRISM Constraints on Unidentified X-Ray Emission Lines, Including the 3.5 keV Line, in the Stacked Spectrum of 10 Galaxy Clusters

We stack 3.75 Ms of early XRISM Resolve observations of 10 galaxy clusters to search for unidentified spectral lines in the E = 2.5–15 keV band (rest frame), including the E = 3.5 keV line reported in earlier low spectral resolution studies of cluster samples. Such an emission line may originate from the decay of the sterile neutrino, a warm dark matter (DM) candidate. No unidentified lines are detected in our stacked cluster spectrum, with the 3σ upper limit on the m s ∼ 7.1 keV DM particle decay rate (which corresponds to an E = 3.55 keV emission line) of Γ ∼ 1.0 × 10 −27 s −1 . This upper limit is 3–4 times lower than the one derived by Hitomi Collaboration from the Perseus observation but still 5 times higher than the XMM-Newton detection reported by E. Bulbul et al. in the stacked cluster sample. XRISM Resolve, with its high spectral resolution but small field of view, may reach the sensitivity needed to test the XMM-Newton cluster sample detection by combining several years worth of future cluster observations.

Astronomy and AstroPhysics

Stacked networks improve physics-informed training: Applications to neural networks and deep operator networks

Physics-informed neural networks and operator networks have shown promise for effectively solving equations modeling physical systems. However, these networks can happen to be difficult or impossible to train accurately. Here, we present a novel multifidelity framework for stacking physics-informed neural networks and operator networks that facilitates training. We successively build a chain of networks, where the output at one step can act as a low-fidelity input for training a longer chain, gradually increasing the expressivity of the learnt model. The equations imposed at each step of the iterative process can be the same or different (akin to simulated annealing). The iterative (stacking) nature of the proposed method allows us to learn progressively features of a solution which could have been hard to learn directly. Through benchmark problems including a nonlinear pendulum, the wave equation, and the viscous Burgers equation, we show how stacking can be used to improve the accuracy and reduce the required size of physics-informed neural networks and operator networks.

97 MATHEMATICS AND COMPUTING

Adjustable cutting guide aligns and positions stacks of material

Adjustable guide tool aligns and positions stacks of material for cutting at various angles. The device adapts its shape to stacks of any corner angle, adjusts to any cutting angle, and quickly aligns the stacks for repeated cutting. With this device, an operator need not place his hands under the knife during alignment.

Thiel, A. M.

Calibration of a laboratory spectrophotometer for specular light by means of stacked glass plates.

Stacked glass plates have been used to calibrate a laboratory spectrophotometer, over the spectral range 0.5-2.5 microns, for specular light. The uncalibrated instrument was characterized by systematic errors when used to measure the reflectance and transmittance of stacked glass plates. Calibration included first, a determination of the reflectance of a standard composed of barium sulfate paint deposited on an aluminum plate; second, the approximation of the reflectance and transmittance residuals between observed and computed values by means of cubic equations; and, finally, the removal of the systematic errors by a computer. The instrument, after calibration, was accurate to 1% when used to measure the reflectance and transmittance of stacked glass plates.

Allen, W. A.

Remote fire stack igniter

An igniter is described mounted on a vent stack with an upper, flame cage near the top of the stack to ignite emissions from the stack. The igniter is a tube with a lower, open, flared end having a spark plug near the lower end and a solenoid-controlled valve which supplies propane fuel from a supply tank. Propane from the tank is supplied at the top under control of a second, solenoid-controlled valve. The valve controlling the lower supply is closed after ignition at the flame cage. The igniter is economical, practical, and highly reliable.

Ray, W. L.

Energy Conservation Alternatives Study (ECAS): Conceptual Design and Implementation Assessment of a Utility Steam Plant with Conventional Furnace and Wet Lime Stack Gas Scrubbers

A study was performed to estimate the technical/economic characteristics of a steam power plant (3500 pounds per square inch gauge, 1000 degrees Fahrenheit / 1000 degrees Fahrenheit) with a coal-burning radiant furnace and a wet lime stack gas scrubber to control sulfur emissions. Particulate emissions were controlled by an electrostatic precipitator operating at 300 degrees Fahrenheit. The stack gas from the scrubber was reheated from 125 degrees Fahrenheit to 250 degrees Fahrenheit as a base case, and from 125 degrees Fahrenheit to 175 degrees Fahrenheit as an alternate case. The study was performed on a basis consistent with the General Electric ECAS Phase II evaluation of advanced energy conversion systems for electric utility baseload applications using coal or coal-derived fuels. A conceptual design of the power plant was developed, including the on-site calcination of limestone to lime and the provision of sludge ponds to store the products of flue gas scrubbing. From this design, estimates were derived for power plant efficiency, capital cost, environmental intrusion characteristics, natural resource requirements, and cost of electricity at an assumed capacity factor of 65 percent. An implementation assessment was performed where factors affecting applicability of the conceptual design power plant in electric utility generation systems were appraised. At 250 degrees Fahrenheit and 175 degrees Fahrenheit stack gas temperatures respectively, the plants showed a cost of electricity of 39.8 and 37.0 mills per kilowatt-hours and overall plant efficiencies of 32 percent and 34 percent.

Brown, Dale H.

Comparison of stack plume properties obtained from aircraft and spacecraft measurements

Landsat II imagery data and aircraft nephelometer measurements were analyzed to determine the quantitative properties of a stack plume emitted from a moderate-sized pulpmill. Aircraft measurements were obtained at several heights across the plume at 1.0, 3.0, and 6.5 km downwind from the stack, and for comparative purposes, the Landsat data were also analyzed at these same three locations and at 0.5 and 10.0 km. Overlapping, consecutive-day MSS data provided plume/no-plume radiances upwelling from the stack site. Imagery data from a 10- by 10 km region in the vicinity of the mill were normalized to correct for atmospheric, solar, and viewing angle differences for the 2 observation days, and cloud-shadow data were used to evaluate sky radiance. Particle concentrations, vertical and lateral dispersions, and plume heights determined from both the aircraft and spacecraft measurement techniques are in good agreement.

Staylor, W. F.

Manual of phosphoric acid fuel cell stack three-dimensional model and computer program

A detailed distributed mathematical model of phosphoric acid fuel cell stack have been developed, with the FORTRAN computer program, for analyzing the temperature distribution in the stack and the associated current density distribution on the cell plates. Energy, mass, and electrochemical analyses in the stack were combined to develop the model. Several reasonable assumptions were made to solve this mathematical model by means of the finite differences numerical method.

Lu, C. Y.

Hydrogen Embrittlement And Stacking-Fault Energies

Embrittlement in Ni/Cu alloys appears related to stacking-fault porbabilities. Report describes attempt to show a correlation between stacking-fault energy of different Ni/Cu alloys and susceptibility to hydrogen embrittlement. Correlation could lead to more fundamental understanding and method of predicting susceptibility of given Ni/Cu alloy form stacking-fault energies calculated from X-ray diffraction measurements.

Parr, R. A.

PEM fuel cell stack heat and mass management

PEM stacks are under evaluation as candidates for future space power technology. Results of long-term operation on a set of contemporary stacks fitted with different proton exchange membrane materials are given. Data on water balances show effects of membrane materials on stack performance.

Vanderborgh, Nicholas E.

Arbitrarily shaped dual-stacked patch antennas: A hybrid FEM simulation

A dual-stacked patch antenna is analyzed using a hybrid finite element - boundary integral (FE-BI) method. The metallic patches of the antenna are modeled as perfectly electric conducting (PEC) plates stacked on top of two different dielectric layers. The antenna patches may be of any shape and the lower patch is fed by a coaxial cable from underneath the ground plane or by an aperture coupled microstrip line. The ability of the hybrid FEM technique for the stacked patch antenna characterization will be stressed, and the EM coupling mechanism is also discussed with the aid of the computed near field patterns around the patches.

Gong, Jian

Effects of Geometric Azimuthal Asymmetries of the PPM Stack on Electron Beam Characteristics

The effects of geometric azimuthally asymmetric properties of a periodic permanent magnet (PPM) focusing stack on electron beam characteristics obtained using a fully three dimensional (3D) particle-in-cell (PIC) code will be presented. The simulation model, using MAFIA (Solution of MAxwell's equations by the Finite-Integration-Algorithm), incorporates 3D behavior of the beam immersed in static fields calculated directly from the exact geometry and material properties of the 3D magnetic focusing structure. The Hughes 8916H, 18-40 GHz helical TWT for the millimeter-wave power module (MMPM) was used as a prototype. Firstly, the effects of C-magnets used at the input and output of the TWT to allow for coupling of the RF signal into and out of the tube are considered. The 8916H input and output C-magnets differ because coaxial couplers are used at the input and waveguide couplers are used at the output The repositioning of the beam from its central axis due to the inclusion of the output C-magnet was found to be most significant. The modeled output C-magnet and its orientation in the Cartesian coordinate system is shown, and a two-dimensional beam profile including the output C-magnet is also shown. A table presents the shift of the beam center off the central axis relative to the average radius of the beam at the longitudinal points A, B and C designated on an enclosed figure. Secondly, the addition of shunts, or rectangular iron pieces applied manually by a skilled technician in order to improve beam transmission, is considered. The shunts are applied to the top of the tube; thus, azimuthal symmetry of the focusing stack is interrupted. Although shunts are typically added during RF focusing, they are also typically added at the input section of the tube where RF forces are minimal, making an electron optics analysis meaningful. Because several shunts are usually applied to one pole piece, the simulations have been simplified by modeling a half washer with the same radius and longitudinal length as a shunt over the entire x, positive-y half of the transverse plane. A modeled pole piece and shunt as described are shown. Lastly, in order to study the effects of magnet misalignments, a magnet in the PPM stack was arbitrarily chosen and adjusted so that its central axis was shifted both 0.7 percent and 1.0 percent of the magnet outer diameter in the positive-y direction. In practice, positioning the magnets so that their central axis is accurately aligned with the central axis of the tube is challenging. Thus, it is a strong possibility that one or more magnets will be misaligned relative to the tube central axis.

Kory, Carol L.