Search NASA⌕ Search

SEARCH · Search NASA

Results for “synchronization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Software-Defined Virtual Synchronous Condenser

Synchronous condensers (SCs) play important roles in integrating wind energy into relatively weak power grids. However, the design of SCs usually depends on specific application requirements and may not be adaptive enough to the frequently-changing grid conditions caused by the transition from conventional to renewable power generation. This paper devises a software-defined virtual synchronous condenser (SDViSC) method to address the challenges. Our contributions are fourfold: 1) design of a virtual synchronous condenser (ViSC) to enable full converter wind turbines to provide built-in SC functionalities; 2) engineering SDViSCs to transfer hardware-based ViSC controllers into software services, where a Tustin transformation-based software-defined control algorithm guarantees accurate tracking of fast dynamics under limited communication bandwidth; 3) a software-defined networking-enhanced SDViSC communication scheme to allow enhanced communication reliability and reduced communication bandwidth occupation; and 4) Prototype of SDViSC on our real-time, cyber-in-the-loop digital twin of large-wind-farm in an RTDS environment. Furthermore, extensive test results validate the excellent performance of SDViSC to support reliable and resilient operations of wind farms under various physical and cyber conditions.

17 WIND ENERGY↗

Implementation of quantum key distribution and quantum clock synchronization via time bin encoding

Quantum key distribution allows for a provably secure transmission of cryptographic keys over an optical channel. Encoded polarization states or time-bin degree of freedom have been used for successful demonstrations. However, photon losses in long fibers, slow single photon detectors, and detector dark counts significantly limit the overall bit rate. Improving key throughput and reducing the overhead of key reconciliation remain as major challenges. Methods which utilize multiple time bins allow for multiple key bits to be encoded in a single photon, thus increasing the fidelity of transmitted keys and decreasing the overhead of key reconciliation in real-world conditions. Previous implementations of these methods required that Alice and Bob share a time reference by sharing a dedicated classical channel used for synchronization. This work presents a technique that allows two parties to exchange time-bin encoded photons without the need for synchronized time references. Our technique uses a framing protocol which allows Alice to encode a time reference along with a key which is determined by Alice before transmission. Security can be achieved by monitoring the visibility of a pair of Franson interferometers, using decoy pulses and measuring the round trip time between Alice and Bob. The bit rate of this technique is limited only by the recovery time of the detector and the speed of the modulation electronics. We experimentally demonstrate a raw bit rate of 5Mb/s over an optical channel with 55dB of loss, which is competitive with current research. We also demonstrate absolute timing synchronization with an accuracy of 20ps.

encryption↗

Virtual Time III, Part 2: Combining Conservative and Optimistic Synchronization

This is Part 2 of a trio of works intended to provide a unifying framework in which conservative and optimistic synchronization for parallel discrete event simulations can be freely and transparently combined in the same logical process on an event-by-event basis. Here, in this article, we continue the outline of an approach called Unified Virtual Time (UVT) that was introduced in Part 1, showing in detail via two extended examples how conservative synchronization can be refactored and combined with optimistic synchronization in the UVT framework. We describe UVT versions of both a basic time windowing algorithm called Unified Simple Time Windows and a refactored version of the Chandy-Misra-Bryant Null Message algorithm called Unified CMB.

97 MATHEMATICS AND COMPUTING↗

Resilience of the slow component in timescale separated synchronized oscillators

Physiological networks are usually made of a large number of biological oscillators evolving on a multitude of different timescales. Phase oscillators are particularly useful in the modelling of the synchronization dynamics of such systems. If the coupling is strong enough compared to the heterogeneity of the internal parameters, synchronized states might emerge where phase oscillators start to behave coherently. Here, we focus on the case where synchronized oscillators are divided into a fast and a slow component so that the two subsets evolve on separated timescales. We assess the resilience of the slow component by, first, reducing the dynamics of the fast one using Mori-Zwanzig formalism. Second, we evaluate the variance of the phase deviations when the oscillators in the two components are subject to noise with possibly distinct correlation times. From the general expression for the variance, we consider specific network structures and show how the noise transmission between the fast and slow components is affected. Interestingly, we find that oscillators that are among the most robust when there is only a single timescale, might become the most vulnerable when the system undergoes a timescale separation. We also find that layered networks seem to be insensitive to such timescale separations.

97 MATHEMATICS AND COMPUTING↗

Resilience of the slow component in timescale-separated synchronized oscillators

Physiological networks are usually made of a large number of biological oscillators evolving on a multitude of different timescales. Phase oscillators are particularly useful in the modelling of the synchronization dynamics of such systems. If the coupling is strong enough compared to the heterogeneity of the internal parameters, synchronized states might emerge where phase oscillators start to behave coherently. Here, we focus on the case where synchronized oscillators are divided into a fast and a slow component so that the two subsets evolve on separated timescales. We assess the resilience of the slow component by, first, reducing the dynamics of the fast one using Mori-Zwanzig formalism. Second, we evaluate the variance of the phase deviations when the oscillators in the two components are subject to noise with possibly distinct correlation times. From the general expression for the variance, we consider specific network structures and show how the noise transmission between the fast and slow components is affected. Interestingly, we find that oscillators that are among the most robust when there is only a single timescale, might become the most vulnerable when the system undergoes a timescale separation. We also find that layered networks seem to be insensitive to such timescale separations.

59 BASIC BIOLOGICAL SCIENCES↗

Novel Rotated Virtual Synchronous Generator Control for Power-Sharing in Microgrids with Complex Line Impedance

Virtual synchronous generator (VSG) control is based on the fact that the line impedance in a microgrid is highly inductive. This assumption was made due to the emulation of the stator winding of an electrical machine. This concept can affect the controllability of a microgrid with complex line impedance, generating deviations in the chosen operation point. To overcome this issue, additional techniques must be implemented. This paper describes a novel mathematical approach that uses the power line characteristics in a microgrid to rotate the power control reference frame and proposes a new control method called a “Rotated Virtual Synchronous Generator” (RVSG). This RVSG control approach integrates the effect of complex impedance on the microgrid’s operation and adjusts the reference frame accordingly to improve the system’s stability and performance. The use of this proposed mathematical approach in microgrids allows the further emulation of virtual inertia in microgrids that lack inertia. Finally, a comparison between RVSG control and the classical virtual synchronous generator method is carried out to show that it allows the improvement of the transient power response, power quality, stability, and performance, mainly in microgrids with complex line impedance.

42 ENGINEERING↗

Time Synchronization Techniques in the Modern Smart Grid: A Comprehensive Survey

In modern smart grids, accurate and synchronized time signals are essential for effective monitoring, protection, and control. Various time synchronization methods exist, each tailored to specific application needs. Widely adopted solutions, such as GPS, however, are vulnerable to challenges such as signal loss and cyber-attacks, underscoring the need for reliable backup or supplementary solutions. This paper examines the timing requirements across different power grid applications and provides a comprehensive review of available time synchronization mechanisms. Through a comparative analysis of timing methods based on accuracy, flexibility, reliability, and security, this study offers insights to guide the selection of optimal solutions for seamless grid integration.

comparison↗

Small-Signal Stability Analysis of Low-Inertia Power Grids with Inverter-Based Resources and Synchronous Condensers: Preprint

With the potential environmental impacts of conventional fossil fuels and the technology advances of grid interactive power electronics, inverter-based resources (IBRs) are playing a crucial role in modern power grids. However, due to the lack of physical inertia, IBRs are vulnerable to system disturbances. Further, conventional grid-following (GFL) inverters cannot actively establish the frequency and voltage, which could not be a appropriate solution for 100% inverter-based power grids. Grid-forming (GFM) control, as an emerging inverter control function, has drawn great attention in recent years, while it is still under development and pre-mature for large-scale field deployment. A potential solution for gradually transitioning into a 100% inverter-based power grid is to combine both IBRs and synchronous machines into a mixed generation portfolio. More importantly, synchronous machines can be operated as synchronous condensers (SCs) until they are retired. It is also worth mentioning that the stability analysis is of great importance to ensure the smooth transition from existing power grids to 100% inverter-based system, which is the main focus of this work with detailed modeling and modal analysis.

100% renewable↗

Enhancing Synchronous Condenser Operation of Hydrogenerators

Hydropower plants are sometimes dispatched below capacity or even shut down to meet water regulations. These can temporarily be repurposed to operate as synchronous condensers. To enable this capability, this paper proposes a design that allows hydrogenerators to safely operate as synchronous condensers, providing fast voltage and reactive power support under both normal and boost conditions. The proposed design integrates capability curves with hydrogenerators’ excitation systems through modifications using proposed MVA-field current curve, current controller, and limiter. The design is implemented locally at the machine for rapid response. Simulation results demonstrate the effectiveness of the proposed design and using hydrogenerators as synchronous condensers in power grids.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Non-Synchronous Rotation on Europa Driven by Ocean Currents

It has been suggested that the ice shell of Jupiter's moon Europa may drift non-synchronously due to tidal torques. Here we argue that torques applied by the underlying ocean are also important and can result in non-synchronous rotation. The resulting spin rate can be slightly slower than the synchronous angular rate that would have kept the same point of the ice shell facing Jupiter. We develop an ice shell rotation model, driven by ocean stress calculated using a high-resolution state-of-the-art ocean general circulation model, and take into account the viscoelastic deformation of the ice shell. We use the ice shell model results together with observed limits on the ice shell drift speed to constrain ice shell parameters such as effective viscosity, which is currently uncertain by at least four orders of magnitude. Our results suggest, at best, sluggish ice shell convection. Depending on the relaxation time scale of the ice shell and on the ocean currents, the ice shell may exhibit negligible drift, constant drift, or oscillatory drift superimposed on random fluctuations. The expected rotation rate exceeds ~30 m/yr; future spacecraft observations can be used to test these predictions and yield insight into the properties of the ice shell and underlying ocean.

15 GEOTHERMAL ENERGY↗

Synchronizing the consistency relation

We study the N-point function of the density contrast to quadratic order in the squeezed limit during the matter-dominated (MD) and radiation-dominated (RD) eras in synchronous gauge. Since synchronous gauge follows the free-fall frame of observers, the equivalence principle dictates that in the gradient approximation for the long-wavelength mode there is only a single, manifestly time-independent consistency relation for the N-point function. This simple form is dictated by the initial mapping between synchronous and local coordinates, unlike Newtonian gauge and its correspondingly separate dilation and Newtonian consistency relations. Dynamical effects only appear at quadratic order in the squeezed limit and are again characterized by a change in the local background, also known as the separate universe approach. We show that for the 3-point function the compatibility between these squeezed-limit relations and second-order perturbation theory requires both the initial and dynamical contributions to match, as they do in single-field inflation. This clarifies the role of evolution or late-time projection effects in establishing the consistency relation for observable bispectra, which is especially important for radiation acoustic oscillations and for establishing consistency below the matter-radiation equality scale in the MD era. Defining an appropriate angle and time average of these oscillations is also important for making separate universe predictions of spatially varying local observables during the RD era, which can be useful for a wider range of cosmological predictions beyond N-point functions.

79 ASTRONOMY AND ASTROPHYSICS↗

Enhancing Time Synchronization in Smart Grid With White Rabbit: Theory, Architecture, and Challenges

The smart grid aims to provide economically efficient and sustainable power to consumers with high quality and security. However, the increasing integration of distributed renewable energy sources presents challenges for smart grid protection and control systems. Here, to enhance smart grid operations, this article introduces White Rabbit (WR) as a more precise and accurate time synchronization technique. To explore White Rabbit’s potential applications in the smart grid, this study first explains existing time synchronization techniques and their limitations, followed by an analysis of the role and importance of time synchronization in smart grids. A comprehensive survey is then conducted, covering the theories, principles, implementations, performances, and existing application cases of White Rabbit. The findings suggest that White Rabbit is a promising technique for smart grid deployment. However, several challenges remain on the path to large-scale implementation. These challenges are analyzed in detail, highlighting key areas for future research.

Liu, Yu [University of Tennessee, Knoxville, TN (U↗

Microgrid to Microgrid Synchronization with Grid-Forming Inverters: Challenges and Solution

Research on network microgrids has primarily focused on control and optimization. However, application aspects such as microgrid-to-microgrid synchronization have not been fully addressed in existing literature. This paper first addresses the challenges of networking microgrids with grid-forming inverter in droop control. Then, it proposes a pre-synchronization algorithm to improves the synchronization speed and transient stability. To improve the speed, the phase difference between adjacent microgrids is minimized. Transients such as inrush current and oscillations are effectively mitigated by increasing the virtual impedance during interconnection. The proposed strategy allows smooth transitions when reconfiguration of the microgrids is needed. The applicability of this strategy to today’s microgrid systems is demonstrated through a validation in a 480V three-phase network microgrid testbed with commercial-grade inverters, protective devices, and switchgear.

Ferrari Maglia, Max↗

Bulk Power System Dynamics with Varying Levels of Synchronous Generators and Grid-Forming Power Inverters

Inverters using phase-locked loops for control depend on voltages generated by synchronous machines to operate. This might be problematic if much of the conventional generation fleet is displaced by inverters. To solve this problem, grid-forming control for inverters has been proposed as being capable of autonomously regulating grid voltages and frequency. Presently, the performance of bulk power systems with massive penetration of grid-forming inverters has not been thoroughly studied as to elucidate benefits. Hence, this paper presents inverter models with two grid-forming strategies: virtual oscillator control and droop control. The two models are specifically developed to be used in positive-sequence simulation packages and have been implemented in PSLF. The implementations are used to study the performance of bulk power grids incorporating inverters with gridforming capability. Specifically, simulations are conducted on a modified IEEE 39-bus test system and the microWECC test system with varying levels of synchronous and inverter-based generation. The dynamic performance of the tested systems with gridforming inverters during contingency events is better than cases with only synchronous generation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Synchronization for CXL Based Memory

Compute Express Link (CXL) is an important emerging standard for disaggregated memory. While this standard provisions coherency across numerous hosts and devices, implementing hardware support for type three devices is challenging. In this work, we look at the overhead of software synchronization and using software-based coherency. Moreover, we discuss the limits of software-based coherency in fully expressing modern synchronization techniques for a CXL-based disaggregate memory system. We demonstrate our approach using a CXL hardware prototype and running a version of the famous Peterson Lock (enhanced to run with more than two threads). We analyze its performance and share how more advanced synchronization techniques might interact with software-based coherence CXL hardware and program execution models.

High Performance Computing (HPC)↗

Timing and Synchronization in the LLRF systems of the Fermilab PIP-II Linac

The PIP-II Accelerator is an 800 MeV superconducting Linac in the injection chain of the Fermilab accelerator complex. The LLRF systems for the 125 cavities which include a few normal conducting cavities in the warm front-end section, use a variety of LLRF hardware components and sub-systems that are part of the timing and synchronization system. This includes a master oscillator and phase averaging reference line, a beam pattern generator to enable beam transfer between non-harmonic RF systems and beam loading compensation systems synchronized to a start of beam trigger. The timing signals are based on a 650 MHz clock with manchester encoded event information and data provided over optical fiber. The timing and synchronization systems and their performance parameters will be described here.

Varghese, Philip↗

Synchronous Machine Governor Upgrade

Conventional generation sources play a critical role in the stability and reliability of the electrical grid, particularly as we transition towards more renewable energy sources. To understand and accurately emulate their behavior for optimizing grid operations and ensuring seamless integration with renewable technologies, it is essential to better emulate the grid- and plant-level impacts of conventional generation sources, such as natural gas (NG) driven heat recovery steam generators (HRSGs) and combustion turbines (CTs). Therefore, a governor model is developed in a programmable logic controller (PLC) to investigate the performance of the conventional generator under various dynamic operating conditions and to identify the impact on grid stability in a controlled environment. The governor model aims to enable the hardware-in-the-loop (HIL) based emulation of these conventional generation sources using the existing 2 MVA synchronous machine/generator that is driven by a flexible 2.5 MW variable speed drive. This setup will allow us to replicate the dynamic characteristics and response behaviors of NG-driven HRSGs and CTs. The controls for the emulated conventional plants follow the industry standard and are adjustable, ensuring they accurately reflect the operational capabilities and limitations of real-world systems. These controls include load-following capabilities, ramp rates, startup and shutdown sequences, and emissions characteristics. By incorporating these adjustable controls, we aim to capture the nuanced impacts of conventional generation, such as their ability to provide ancillary services like frequency regulation, voltage support, and spinning reserve. In this report, we simulate two types of dynamic operations: grid-connected and islanding. For each dynamic operation, representative starting sequences are tested, including turbine purge, ignition, speed ramping up, generator excitation and synchronizing, and breaker close. The HIL based tests provides insights for field deployment, specifically the high-fidelity governor model provides results to predict the potential stability and reliability risk and suggest possible integration measures (e.g., generation and load balancing, tuning of governor control parameters). Ultimately, this enhanced emulation capability will be integrated into our Advanced Research on Integrated Energy Systems (ARIES), enabling us to conduct comprehensive studies on the interactions between conventional and renewable energy sources. By better understanding these interactions, we can develop strategies to optimize the overall performance and reliability of the grid. This will support the deployment of advanced grid management techniques, such as demand response, grid-forming inverters, and energy storage systems. The main contributions are summarized as follows: (1) This report introduces a PLC-based governor model for gas turbines. This model accurately simulates the dynamic behavior of conventional generation sources under various operational scenarios; (2) The model is integrated with an HIL testbed that includes a 2.5 MW variable speed drive and a 2 MVA synchronous machine. This setup enables realistic, real-time emulation of conventional power plants, particularly NG driven HRSGs and CTs; (3) The developed model is adaptable to various gas turbine configurations and allows for precise control over parameters such as MW ramp rates. This flexibility makes it a valuable tool for future research and industry collaboration; and (4) By incorporating the model into the National Renewable Energy Laboratory's Advanced Research on Integrated Energy Systems, the report lays the groundwork for future studies on interactions between conventional and renewable energy sources, enhancing the ability to develop advanced grid management strategies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Synchronous Rotation in the (136199) Eris–Dysnomia System

We combine photometry of Eris from a 6 month campaign on the Palomar 60 inch telescope in 2015, a 1 month Hubble Space Telescope WFC3 campaign in 2018, and Dark Energy Survey data spanning 2013–2018 to determine a light curve of definitive period 15.771 ± 0.008 days (1σ formal uncertainties), with nearly sinusoidal shape and peak-to-peak flux variation of 3%. This is consistent at part-per-thousand precision with the P = 15.785 90 ± 0.00005 day sidereal period of Dysnomia's orbit around Eris, strengthening the recent detection of synchronous rotation of Eris by Szakáts et al. with independent data. Photometry from Gaia are consistent with the same light curve. We detect a slope of 0.05 ± 0.01 mag per degree of Eris's brightness with respect to illumination phase averaged across g, V, and r bands, intermediate between Pluto's and Charon's values. Variations of 0.3 mag are detected in Dysnomia's brightness, plausibly consistent with a double-peaked light curve at the synchronous period. The synchronous rotation of Eris is consistent with simple tidal models initiated with a giant-impact origin of the binary, but is difficult to reconcile with gravitational capture of Dysnomia by Eris. The high albedo contrast between Eris and Dysnomia remains unexplained in the giant-impact scenario.

79 ASTRONOMY AND ASTROPHYSICS↗