Search NASA⌕ Search

SEARCH · Search NASA

Results for “transformer windings”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Ultra-light duct for an anechoic wind tunnel

A tunnel ultra-light (or TUL) is a duct composed of acoustically transparent cloth designed to transform an open-jet wind tunnel into a closed-jet wind tunnel. This concept is of interest (a priori) for anechoic wind tunnels because it improves the aerodynamic quality without hindering the measurement of sound in the far field. A full scale device designed for the 3 m diameter test section of CEPRA 19 was described. The apparatus installation did not develop any significant problems, and the mechanical support turned out to be excellent. Aerodynamic and acoustic tests are discussed. Certain imperfections in the installation as tested - instabilities above 25 m/s and acceptable cloth transmission up to 4kHz were revealed. The system as tested could eventually be used in certain applications, for example, in ground based transport. However, the concept of TUL must be developed further to arrive at a reliable mechanism for use in a large number of applications.

Lambourion, J.↗

Advances in measuring techniques for turbine cooling test rigs - Status report

Instrumentation development pertaining to turbine cooling research has resulted in the design and testing of several new systems. Pressure measurements on rotating components are being made with a rotating system incorporating ten miniature transducers and a slip-ring assembly. The system has been tested successfully up to speeds of 9000 rpm. An advanced system development combining pressure transducer and thermocouple signals is also underway. Thermocouple measurements on rotating components are transferred off the shaft by a 72-channel rotating data system. Thermocouple data channels are electronically processed on board and then removed from the shaft in the form of a digital serial train by one winding of a rotary transformer.

Pollack, F. G.↗

A comparison between the current models of mid-latitude spread F and data from the Arecibo Observatory

The current models of mid-latitude F sub s are studied. The assumptions and derivations of the Reid model, the Scannapieco model, and the Perkins model are presented in detail. Incoherent-scatter data of the density profiles and velocity profiles were obtained in order that the models could be evaluated on the basis of experimental data. Initial studies indicated that the Perkins model was most representative of the data from Arecibo, so a detailed comparison of the predictions of the Perkins model and the data was made. Two of four nights studied are nights with F sub s. The Perkins model is derived in a frame of reference moving with the velocity of the neutral wind; the model is transformed to the rest frame to facilitate comparison with data. Several data handling techniques are introduced. In particular, an integration interval that remains constant in length, but follows the vertical motion of the peak of the F layer is used to obtain the field integrated quantities of the Perkins model.

Imel, G.↗

Push-pull converter with energy saving circuit for protecting switching transistors from peak power stress

In a push-pull converter, switching transistors are protected from peak power stresses by a separate snubber circuit in parallel with each comprising a capacitor and an inductor in series, and a diode in parallel with the inductor. The diode is connected to conduct current of the same polarity as the base-emitter juction of the transistor so that energy stored in the capacitor while the transistor is switched off, to protect it against peak power stress, discharges through the inductor when the transistor is turned on, and after the capacitor is discharges through the diode. To return this energy to the power supply, or to utilize this energy in some external circuit, the inductor may be replaced by a transformer having its secondary winding connected to the power supply or to the external circuit.

Mclyman, W. T.↗

ISEE/IMP observations of simultaneous upstream ion events

Propagation of upstream energetic (50-200 keV) ions is analyzed in sixteen events observed simultaneously by solid state detectors on ISEE 3 at about 200 earth radii and on IMP 8 at about 35 earth radii from the earth. Conclusions are based on comparisons of the pitch angle distributions observed at the two spacecraft and transformed into the solar wind frame. They are beamlike at ISEE 3 and are confined to the outward hemisphere. When IMP 8 is furthest from the bow shock, they are also usually beamlike, or hemispheric. However, when IMP 8 is closer to the bow shock, pancakelike distributions are observed. This systematic variation in the IMP 8 pitch angle distributions delimits a scattering region l less than about 15 earth radii upstream of the earth's bow shock (l measured along the interplanetary magnetic field) that dominates ion propagation, influences the global distribution of fluxes in the foreshock, and may play a role in acceleration of the ions. When IMP 8 is beyond l of about 15 earth radii the propagation appears to be essentially scatter-free between IMP 8 and ISEE 3; this is deduced from the absence of earthward fluxes at IMP 8 as well as the tendency for the spin-averaged fluxes to be comparable at the two spacecraft.

Mitchell, D. G.↗

Wearable Wireless Telemetry System for Implantable BioMEMS Sensors

Telemetry systems of a type that have been proposed for the monitoring of physiological functions in humans would include the following subsystems: Surgically implanted or ingested units that would comprise combinations of microelectromechanical systems (MEMS)- based sensors [bioMEMS sensors] and passive radio-frequency (RF) readout circuits that would include miniature loop antennas. Compact radio transceiver units integrated into external garments for wirelessly powering and interrogating the implanted or ingested units. The basic principles of operation of these systems are the same as those of the bioMEMS-sensor-unit/external-RFpowering- and-interrogating-unit systems described in "Printed Multi-Turn Loop Antennas for Biotelemetry" (LEW-17879-1) NASA Tech Briefs, Vol. 31, No. 6 (June 2007), page 48, and in the immediately preceding article, "Hand-Held Units for Short-Range Wireless Biotelemetry" (LEW-17483-1). The differences between what is reported here and what was reported in the cited prior articles lie in proposed design features and a proposed mode of operation. In a specific system of the type now proposed, the sensor unit would comprise mainly a capacitive MEMS pressure sensor located in the annular region of a loop antenna (more specifically, a square spiral inductor/ antenna), all fabricated as an integral unit on a high-resistivity silicon chip. The capacitor electrodes, the spiral inductor/antenna, and the conductor lines interconnecting them would all be made of gold. The dimensions of the sensor unit have been estimated to be about 110.4 mm. The external garment-mounted powering/ interrogating unit would include a multi-turn loop antenna and signal-processing circuits. During operation, this external unit would be positioned in proximity to the implanted or ingested unit to provide for near-field, inductive coupling between the loop antennas, which we have as the primary and secondary windings of an electrical transformer.

Simons, Rainee N.↗

High-Voltage Isolation Transformer

Arcing and field-included surface erosion reduced by electrostatic shields around windings and ferromagnetic core of 80-kilovolt isolation transformer. Fabricated from high-resistivity polyurethane-based material brushed on critical surfaces, shields maintained at approximately half potential difference of windings.

Clatterbuck, C. H.↗

Magnetically Controlled Variable Transformer

Improved variable-transformer circuit, output voltage and current of which controlled by use of relatively small current supplied at relatively low power to control windings on its magnetic cores. Transformer circuits of this type called "magnetic amplifiers" because ratio between controlled output power and power driving control current of such circuit large. This ratio - power gain - can be as large as 100 in present circuit. Variable-transformer circuit offers advantages of efficiency, safety, and controllability over some prior variable-transformer circuits.

Kleiner, Charles T.↗

Low current linearization of magnetic amplifier for dc transducer

A magnetic amplifier having two saturable reactor cores with a separate excitation winding on each connected in series opposition, a common control winding, and a common output winding, is adapted for use as a low level signal transducer. The separate excitation windings are excited in push-pull mode through a center tapped transformer, and at least one diode is included in series with a load resistor connected to the output winding. A resistor in series with the output winding and load resistor is connected between the center tap of the excitation transformer and the connection between the two excitation windings of the saturable cores. This series resistor provides a return current path for the output winding and allows the excitation windings of the saturable cores to operate as primary windings of transformers.

Nagano, S.↗

Characterization of the surfaces of platinum/tin oxide based catalysts by Fourier transform spectroscopy (FTIR)

The Laser Atmospheric Wind Sounder (LAWS) Program has as one of its goals the development of a satellite based carbon dioxide laser for making wind velocity measurements. The specifications for this laser include the requirement that the laser operate at a repetition rate of 10 Hertz continuously for three years. Earth-based carbon dioxide lasers can operate for only a short time on a single charge of gas because the lasing action causes the CO2 to break down into CO and O2. Therefore, earth-based CO2 lasers are generally operated in a flow through mode in which the spent gas is continually exhausted and fresh gas is continually added. For a satellite based system, however, a recirculation system is desired because it is not practical to send up extra tanks of CO2. A catalyst which could enable a recirculating CO2 laser to function continuously for three years needs to be developed. In the development of a catalyst system there are many variables. Obviously, not all possible formulations can be tested for three years, therefore, an accurate model which is based on the reaction mechanism is needed. The construction of a multistep reaction mechanism is similar to the construction of a jigsaw puzzle. Different techniques each supply a piece of the puzzle and the researcher must put the pieces together. Transmission infrared spectroscopy was shown to be very useful in supplying some of the information needed to elucidate reaction mechanisms. The purpose was to see what kind of information might be obtained about the NASA catalyst using infrared absorption spectroscopy. Approximately 200 infrared spectra of the prototype Pt/tin oxide catalyst and its precursor components are observed under a variety of different conditions. The most significant observations are summarized.

Keiser, Joseph T.↗

Negative coupled inductors for polyphase choppers

A technique for negatively coupling the outputs of polyphase choppers is disclosed, wherein the output inductance of each phase is divided into two windings, and each winding is negatively coupled to a corresponding winding of a neighboring phase. In a preferred embodiment for a three-phase chopper circuit, the output inductance of phase A is divided into windings 100 and 102, the output inductance of phase B is divided into windings 110 and 112, and the output inductance of phase C is divided into windings 120 and 122. Pairs of windings 100 and 110, 112 and 120, and 102 and 122 are respectively disposed in transformers arranged for negatively coupling the windings of each pair.

Jamieson, Robert S.↗

Position Sensor Integral with a Linear Actuator

A noncontact position sensor has been designed for use with a specific two-dimensional linear electromagnetic actuator. To minimize the bulk and weight added by the sensor, the sensor has been made an integral part of the actuator: that is to say, parts of the actuator structure and circuitry are used for sensing as well as for varying position. The actuator (see Figure 1) includes a C-shaped permanent magnet and an armature that is approximately centered in the magnet gap. The intended function of the actuator is to cause the permanent magnet to translate to, and/or remain at, commanded x and y coordinates, relative to the armature. In addition, some incidental relative motion along the z axis is tolerated but not controlled. The sensor is required to measure the x and y displacements from a nominal central position and to be relatively insensitive to z displacement. The armature contains two sets of electromagnet windings oriented perpendicularly to each other and electrically excited in such a manner as to generate forces in the x,y plane to produce the required motion. Small sensor excitation coils are mounted on the pole tips of the permanent magnet. These coils are excited with a sine wave at a frequency of 20 kHz. This excitation is transformer-coupled to the armature windings. The geometric arrangement of the excitation coils and armature windings is such that the amplitudes of the 20-kHz voltages induced in the armature windings vary nearly linearly with x and y displacements and do not vary significantly with small z displacements. Because the frequency of 20 kHz is much greater than the maximum frequency characteristic of the actuation signals applied to the armature windings, there is no appreciable interference between actuator and sensor functions of the armature windings.

Howard, David E.↗

New Spray Bar System Installed in NASA Lewis' Icing Research Tunnel

NASA Lewis Research Center's Icing Research Tunnel (IRT) is the world's largest refrigerated wind tunnel dedicated to the study of aircraft icing. In the IRT, natural icing conditions are duplicated to test the effects of in-flight icing on actual aircraft components and on scale models of airplanes and helicopters. The IRT's ability to reproduce a natural icing cloud was significantly improved with the recent installation of a new spray bar system. It is the spray bar system that transforms the low-speed wind tunnel into an icing wind tunnel by producing microscopic droplets of water and injecting them into the wind tunnel air stream in order to accurately simulate cloud moisture.

Irvine, Thomas B.↗

Description of Panel Method Code ANTARES

Panel method code ANTARES was developed to compute wall interference corrections in a rectangular wind tunnel. The code uses point doublets to represent blockage effects and line doublets to represent lifting effects of a wind tunnel model. Subsonic compressibility effects are modeled by applying the Prandtl-Glauert transformation. The closed wall, open jet, or perforated wall boundary condition may be assigned to a wall panel centroid. The tunnel walls can be represented by using up to 8000 panels. The accuracy of panel method code ANTARES was successfully investigated by comparing solutions for the closed wall and open jet boundary condition with corresponding Method of Images solutions. Fourier transform solutions of a two-dimensional wind tunnel flow field were used to check the application of the perforated wall boundary condition. Studies showed that the accuracy of panel method code ANTARES can be improved by increasing the total number of wall panels in the circumferential direction. It was also shown that the accuracy decreases with increasing free-stream Mach number of the wind tunnel flow field.

Ulbrich, Norbert↗

Rotary Transformer Seals Power In

Rotary transformer originally developed for spacecraft transfers electrical power from stationary primary winding to rotating secondary without sliding contacts and very little leakage of electromagnetic radiation. Transformer has two stationary primary windings connected in parallel. Secondary, mounted on a shaft that extends out of housing, rotates between two windings of primary. Shaft of secondary is composed of electrically conducting inner and outer parts separated by an insulator. Electrical contact is made from secondary winding, through shaft, to external leads.

Studer, P. A.↗

The study of mesoscale ocean winds

SAR data gathered over the U.S. East Coast are used to infer near-surface wind speed, using a simplified model to relate the strength of the 30 to 40 cm SAR backscatter to surface wind speed. It is found that the SAR backscatter is nearly isotropic with a wind speed exponent of 0.4. Using this exponent, the model is tested against an independent data set. Subsequent agreement between wind speeds simultaneously determined by SAR and the Seasat-A Satellite Scatterometer (SASS) is within 0.7 m/s rms. A one-dimensional Fourier transform of the SAR-derived wind field shows an increasing energy content in rough agreement with the Van der Hoven spectrum.

Jones, W. L.↗

Observations of heavy energetic ions far upstream from Comet Halley

On March 25, 1986, when the ICE spacecraft came within 28 million km of the nucleus of comet Halley, and for several days around this time, bursts of heavy ions were observed by the ICE energetic ion experiment. The bursts were observed only during periods when the solar wind velocity was considerably higher than its nominal value. The characteristics of these ions, in particular their anisotropies, were examined. Using the well known formulae for transformation of distributions from the solar wind frame of reference to the spacecraft frame, the angular distributions expected from either protons, or heavy ions from the water group, were studied, showing that the measurements are consistent with heavy ions, and not with protons. Other sources of heavy ions are considered, and the most likely source of these ions is comet Halley.

Sanderson, T. R.↗

Control circuit maintains unity power factor of reactive load

Circuit including feedback control elements automatically corrects the power factor of a reactive load. It maintains power supply efficiency where negative load reactance changes and varies by providing corrective error signals to the control windings of a power supply transformer.

Kramer, M.↗