Search NASA⌕ Search

SEARCH · Search NASA

Results for “uniform methods project”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Simulation, Challenge Testing & Validation of Occupancy Recognition & CO 2 Technologies (Final Project Report)

This final report covers the results of the development of testing methods of occupancy sensor systems connected to HVAC controls. This project focused on the development of test methods to evaluate the performance of HVAC-connected occupancy sensor systems, including occupancy presence, occupancy counting, and CO 2 sensor systems in commercial and residential buildings. This included evaluation of the reliability, ease of commissioning, and energy savings potential of these sensor systems. The results of this work help to standardize the methods used to evaluate performance, to enable the ability to compare sensor system performance following the same methods, to understand which sensor systems perform better or worse compared to others. The U.S. building stock’s energy usage can benefit substantially from having building system operations informed by reliable occupancy recognition and CO 2 measurements, however to date, standard methods have not been in place to ensure that sensor systems’ reported performance is uniformly evaluated. The results of this work support the development of a standard or guideline that outlines the developed methods of testing. This project also included the testing of both off-the-shelf and novel SENSOR team-developed low-cost occupancy sensor systems, using the developed methods of testing. The results of this testing helped to inform further development and improvement of new low-cost sensor systems that will benefit from being used in residential and commercial buildings throughout the country.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessing the social sustainability contribution of an infrastructure project under conditions of uncertainty

Assessing the viability of a public infrastructure includes economic, technical and environmental aspects; however, on many occasions, the social aspects are not always adequately considered. This article proposes a procedure to estimate the social sustainability of infrastructure projects under conditions of uncertainty, based on a multicriteria deterministic method. The variability of the method inputs is contributed by the decision-makers. Uncertain inputs are treated through uniform and beta PERT distributions. The Monte Carlo method is used to propagate uncertainty in the method. A case study of a road infrastructure improvement in El Salvador is used to illustrate this treatment. The main results determine the variability of the short and long-term social improvement indices by infrastructure and the probability of the position in the prioritization of the alternatives. The proposed mechanism improves the reliability of the decision making early in infrastructure projects, taking their social contribution into account. The results can complement environmental and economic sustainability assessments. - Highlights: •Estimate the social sustainability of infrastructure projects under conditions of uncertainty •The method uses multicriteria and Monte Carlo techniques and beta PERT distributions •Determines variability of the short and long term social improvement •Determines probability in the prioritization of alternatives •Improves reliability of decision making considering the social contribution.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Engineering of Data Acquiring Mobile Software and Sustainable End-User Applications

The criteria for which data acquiring software and its supporting infrastructure should be designed should take the following two points into account: the reusability and organization of stored online and remote data and content, and an assessment on whether abandoning a platform optimized design in favor for a multi-platform solution significantly reduces the performance of an end-user application. Furthermore, in-house applications that control or process instrument acquired data for end-users should be designed with a communication and control interface such that the application's modules can be reused as plug-in modular components in greater software systems. The application of the above mentioned is applied using two loosely related projects: a mobile application, and a website containing live and simulated data. For the intelligent devices mobile application AIDM, the end-user interface have a platform and data type optimized design, while the database and back-end applications store this information in an organized manner and manage access to that data to only to authorized user end application(s). Finally, the content for the website was derived from a database such that the content can be included and uniform to all applications accessing the content. With these projects being ongoing, I have concluded from my research that the applicable methods presented are feasible for both projects, and that a multi-platform design for the mobile application only marginally drop the performance of the mobile application.

Smith, Benton T.↗

Relationship between x-ray illumination field size and flat field intensity and its impacts on x-ray imaging

Purpose: X-ray cone-beam CT (CBCT) is being increasingly used for various clinical applications, while its performance is still hindered by image artifacts. This work investigates a new source of reconstruction error, which is often overlooked in the current CBCT imaging. The authors find that the x-ray flat field intensity (I{sub 0}) varies significantly as the illumination volume size changes at different collimator settings. A wrong I{sub 0} value leads to inaccurate CT numbers of reconstructed images as well as wrong scatter measurements in the CBCT research. Methods: The authors argue that the finite size of x-ray focal spot together with the detector glare effect cause the I{sub 0} variation at different illumination sizes. Although the focal spot of commercial x-ray tubes typically has a nominal size of less than 1 mm, the off-focal-spot radiation covers an area of several millimeters on the tungsten target. Due to the large magnification factor from the field collimator to the detector, the penumbra effects of the collimator blades result in different I{sub 0} values for different illumination field sizes. Detector glare further increases the variation, since one pencil beam of incident x-ray is scattered into an area of several centimeters on the detector. In this paper, the authors study these two effects by measuring the focal spot distribution with a pinhole assembly and the detector point spread function (PSF) with an edge-spread function method. The authors then derive a formula to estimate the I{sub 0} value for different illumination field sizes, using the measured focal spot distribution and the detector PSF. Phantom studies are carried out to investigate the accuracy of scatter measurements and CT images with and without considering the I{sub 0} variation effects. Results: On our tabletop system with a Varian Paxscan 4030CB flat-panel detector and a Varian RAD-94 x-ray tube as used on a clinical CBCT system, the focal spot distribution has a measured full-width-at-half-maximum (FWHM) of around 0.4 mm, while non-negligible off-focal-spot radiation is observed at a distance of over 2 mm from the center. The measured detector PSF has an FWHM of 0.510 mm, with a shape close to Gaussian. From these two distributions, the author calculate the estimated I{sub 0} values at different collimator settings. The I{sub 0} variation mainly comes from the focal spot effect. The estimation matches well with the measurements at different collimator widths in both horizontal and vertical directions, with an average error of less than 3%. Our method improves the accuracy of conventional scatter measurements, where the scatter is measured as the difference between fan-beam and cone-beam projections. On a uniform water cylinder phantom, more accurate I{sub 0} suppresses the unfaithful high-frequency signals at the object boundaries of the measured scatter, and the SPR estimation error is reduced from 0.158 to 0.014. The proposed I{sub 0} estimation also reduces the reconstruction error from about 20 HU on the Catphan Copyright-Sign 600 phantom in the selected regions of interest to less than 4 HU. Conclusions: The I{sub 0} variation is identified as one additional error source in x-ray imaging. By measuring the focal-spot distribution and detector PSF, the authors propose an accurate method of estimating the I{sub 0} value for different illumination field sizes. The method obtains more accurate scatter measurements and therefore facilitates scatter correction algorithm designs. As correction methods for other CBCT artifacts become more successful, our research is significant in further improving the CBCT imaging accuracy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Implementation Requirements for Nasa Approved Workmanship Standards

This NASA technical standard provides uniform engineering and technical requirements for processes, procedures, practices, and methods that have been endorsed as standard for NASA facilities, programs, and projects, including requirements for selecting, applying, and designing hardware for manufacturability and reliability. This standard establishes NASA workmanship requirements, and clarifications, additions, and exceptions to requirements specified in NASA adopted industry consensus standards identified as required for use by NPR 8735.2, Hardware Quality Assurance Program Requirements for Programs and Projects

workmanship standards↗

Two datasets are better than one: method of double moments for 3D reconstruction in cryo-EM

Cryo-electron microscopy is a powerful imaging technique for reconstructing three-dimensional molecular structures from noisy tomographic projection images of randomly oriented particles. We introduce a new data fusion framework, termed the method of double moments, which reconstructs molecular structures from two instances of the second-order moment of projection images obtained under distinct orientation distributions: one uniform, the other non-uniform and unknown. We prove that these moments generically uniquely determine the underlying structure, up to a global rotation and reflection, and we develop a convex-relaxation-based algorithm that achieves accurate recovery using only second-order statistics. Our results demonstrate the advantage of collecting and modeling multiple datasets under different experimental conditions, illustrating that leveraging dataset diversity can substantially enhance reconstruction quality in computational imaging tasks.

Kam’s method↗

Low-Cost HTS Based Magnet System with an Inductively Coupled Pulsed Energy Extraction Protection System

In this project, RadiaBeam Technologies was tasked with developing a novel solution for a cost effective quench protection based on fast expansion of the normal zone. By inductively coupling a strong electromagnetic pulse via a resonant LC circuit, we attempted to demonstrate accelerated normal zone propagation. The AC field induces currents in the superconducting layer with the current density exceeding that of the critical current density, J c . This creates a large normal zone, uniformly distributing the dissipation through the magnet body. The method does not rely on thermal heating of the conductor, thus enabling nearly instantaneous protection. Through the course of the Phase II project, RadiaBeam Technologies continued extensive numerical modeling of the inductive quench system, re-designed and built several iterations of the POC system for testing and observed evidence of a transient partial quench being induced. However the final device was not fabricated. This was a consequence of the fundamentally complex nature of the energy extraction process and the challenges associated even with demonstrating the proof of concept in a bench top device.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

WE-G-207-07: Iterative CT Shading Correction Method with No Prior Information

Purpose: Shading artifacts are caused by scatter contamination, beam hardening effects and other non-ideal imaging condition. Our Purpose is to propose a novel and general correction framework to eliminate low-frequency shading artifacts in CT imaging (e.g., cone-beam CT, low-kVp CT) without relying on prior information. Methods: Our method applies general knowledge of the relatively uniform CT number distribution in one tissue component. Image segmentation is applied to construct template image where each structure is filled with the same CT number of that specific tissue. By subtracting the ideal template from CT image, the residual from various error sources are generated. Since the forward projection is an integration process, the non-continuous low-frequency shading artifacts in the image become continuous and low-frequency signals in the line integral. Residual image is thus forward projected and its line integral is filtered using Savitzky-Golay filter to estimate the error. A compensation map is reconstructed on the error using standard FDK algorithm and added to the original image to obtain the shading corrected one. Since the segmentation is not accurate on shaded CT image, the proposed scheme is iterated until the variation of residual image is minimized. Results: The proposed method is evaluated on a Catphan600 phantom, a pelvic patient and a CT angiography scan for carotid artery assessment. Compared to the one without correction, our method reduces the overall CT number error from >200 HU to be <35 HU and increases the spatial uniformity by a factor of 1.4. Conclusion: We propose an effective iterative algorithm for shading correction in CT imaging. Being different from existing algorithms, our method is only assisted by general anatomical and physical information in CT imaging without relying on prior knowledge. Our method is thus practical and attractive as a general solution to CT shading correction. This work is supported by the National Science Foundation of China (NSFC Grant No. 81201091), National High Technology Research and Development Program of China (863 program, Grant No. 2015AA020917), and Fund Project for Excellent Abroad Scholar Personnel in Science and Technology.

60 APPLIED LIFE SCIENCES↗

Investigation of Ga 2 O 3 as a new transparent conductive oxide for photovoltaics applications

This small innovation project intended to leverage recent activity and advances in ultrawide-bandgap oxide power electronics toward the investigation of Ga 2 O 3 as a transparent conductive oxide (TCO) for use in photovoltaics (PV). Ga 2 O 3 ’s theoretical advantage over incumbent TCOs is its very large bandgap of 4.8 eV, ensuring optical transparency of photons with λ ≥ 260 nm, effectively the full terrestrial solar spectrum. At the time of proposal writing, literature on Ga 2 O 3 as a TCO/optical material was relatively sparse — what little existed was focused on for UV sensors and/or emitters, with none related to PV. As such, this project was intended to help determine the potential of Ga 2 O 3 as a PV-oriented TCO by investigating its deposition using tools common to the PV and electronics industries — atomic layer deposition (ALD) and RF sputtering (RS), both of which are already used in PV manufacturing — and its resultant optical and electronic properties. Final project goals were to test its application to Si and III-V solar cells. Controllable film thickness and excellent uniformity was established for both methods deposition methods, with ALD providing higher precision for thinner films and RS more effective for growing thicker films. The as-deposited films were found to be amorphous in nature. Spectroscopic ellipsometry (SE) confirmed bandgaps of at least 4.8 eV and non-parasitic absorption across both AM0 and AM1.5G spectra; a refractive index approaching the expected value of 1.8 was also observed, with some degree of tunability based on process parameters. Using this initial optical data, a transfer matrix model, which interfaces with in-house EQE and LIV models, was developed to simulate Ga 2 O 3 optical effects on various solar cells, included potential in antireflection coatings (ARCs). Despite promising optical properties, the resultant resistivity / conductivity metrics did not meet expectations, regardless of deposition process. Although thick RS-deposited films, using both undoped and 1 at% Ge (n-type) doped sintered targets — demonstrated high net carrier concentrations (via C-V), and low specific resistance Ohmic contacts were demonstrated, transmission line measurements (TLM) showed very high resistivity. Further analysis indicated high vertical film conductivity, but very low lateral conductivity. Deeper characterization revealed a relatively high density of nano/microcrystalline inclusions that were ostensibly the source of the vertical conductivity, with the amorphous matrix serving as an effective insulator (likely due to high concentrations of electronic trap states). Despite extensive work to increase film polycrystallinity — demonstrated via high temperature annealing — sufficient lateral conductivity for TCO use was not achieved. The final phase of the project shifted focus toward investigation of ALD-deposited Ga 2 O 3 ’s potential as a passivant and/or passivating contact for both Si and III-V solar cells, with expectation of performance similar to Al 2 O 3 . However, initial rounds of testing using our baseline ALD process yielded minimal (but not quite zero) passivation of both GaInP and Si surfaces. Dielectric passivation is well-known to be highly process sensitive; given the unoptimized nature of the process used, this work was deemed inconclusive. The final outlook with respect to feasibility of Ga 2 O 3 as a PV-oriented TCO is, ultimately, still uncertain. The work performed in this project confirmed the optical properties and deposition methods, but the achieved electrical properties do not meet technological needs; literature reports in recent years are somewhat inconsistent and potentially untrustworthy, but generally appear to be in line with our results. At the very least it is clear that, should Ga 2 O 3 still be under consideration for PV TCO and/or selective contact applications, a significant amount of optimization and study is still needed.

14 SOLAR ENERGY↗

Space charge effects in ultrafast electron diffraction and imaging

Understanding space charge effects is central for the development of high-brightness ultrafast electron diffraction and microscopy techniques for imaging material transformation with atomic scale detail at the fs to ps timescales. We present methods and results for direct ultrafast photoelectron beam characterization employing a shadow projection imaging technique to investigate the generation of ultrafast, non-uniform, intense photoelectron pulses in a dc photo-gun geometry. Combined with N-particle simulations and an analytical Gaussian model, we elucidate three essential space-charge-led features: the pulse lengthening following a power-law scaling, the broadening of the initial energy distribution, and the virtual cathode threshold. The impacts of these space charge effects on the performance of the next generation high-brightness ultrafast electron diffraction and imaging systems are evaluated.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Comparative Study of Welded ODS Cladding materials for AFCI/GNEP Applications

This research project involved working on the pressure resistance welding of oxide dispersion strengthened (ODS) alloys which will have a large role to play in advanced nuclear reactors. The project also demonstrated the research collaboration between four universities and one nation laboratory (Idaho National Laboratory) with participation from an industry for developing for ODS alloys. These alloys contain a high number density of very fine oxide particles that can impart high temperature strength and radiation damage resistance suitable for in-core applications in advanced reactors. The conventional fusion welding techniques tend to produce porosity-laden microstructure in the weld region and lead to the agglomeration and non-uniform distribution of the neededoxide particles. That is why two solid state welding methods - pressure resistance welding (PRW) and friction stir welding (FSW) - were chosen to be evaluated in this project. The proposal is expected to support the development of Advanced Burner Reactors (ABR) under the GNEP program (now incorporated in Fuel Cycle R&D program). The outcomes of the concluded research include training of graduate and undergraduate students and get them interested in nuclear related research.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A statistical, task-based evaluation method for three-dimensional x-ray breast imaging systems using variable-background phantoms

Purpose: For the last few years, development and optimization of three-dimensional (3D) x-ray breast imaging systems, such as digital breast tomosynthesis (DBT) and computed tomography, have drawn much attention from the medical imaging community, either academia or industry. However, there is still much room for understanding how to best optimize and evaluate the devices over a large space of many different system parameters and geometries. Current evaluation methods, which work well for 2D systems, do not incorporate the depth information from the 3D imaging systems. Therefore, it is critical to develop a statistically sound evaluation method to investigate the usefulness of inclusion of depth and background-variability information into the assessment and optimization of the 3D systems. Methods: In this paper, we present a mathematical framework for a statistical assessment of planar and 3D x-ray breast imaging systems. Our method is based on statistical decision theory, in particular, making use of the ideal linear observer called the Hotelling observer. We also present a physical phantom that consists of spheres of different sizes and materials for producing an ensemble of randomly varying backgrounds to be imaged for a given patient class. Lastly, we demonstrate our evaluation method in comparing laboratory mammography and three-angle DBT systems for signal detection tasks using the phantom's projection data. We compare the variable phantom case to that of a phantom of the same dimensions filled with water, which we call the uniform phantom, based on the performance of the Hotelling observer as a function of signal size and intensity. Results: Detectability trends calculated using the variable and uniform phantom methods are different from each other for both mammography and DBT systems. Conclusions: Our results indicate that measuring the system's detection performance with consideration of background variability may lead to differences in system performance estimates and comparisons. For the assessment of 3D systems, to accurately determine trade offs between image quality and radiation dose, it is critical to incorporate randomness arising from the imaging chain including background variability into system performance calculations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-D-207-06: Clinical Validations of Shading Correction for Cone-Beam CT Using Planning CT as a Prior

Purpose: Current cone-beam CT (CBCT) images contain severe shading artifacts mainly due to scatter, hindering their quantitative use in current radiation therapy. We have previously proposed an effective shading correction method for CBCT using planning CT (pCT) as prior knowledge. In this work, we investigate the method robustness via statistical analyses on studies of a large patient group and compare the performance with that of a state-of-the-art method implemented on the current commercial radiation therapy machine -- the Varian Truebeam system. Methods: Since radiotherapy patients routinely undergo multiple-detector CT (MDCT) scans in the planning procedure, we use the high-quality pCT as “free” prior knowledge for CBCT image improvement. The CBCT image with no correction is first spatially registered with the pCT. Primary CBCT projections are estimated via forward projections of the registered image. The low frequency errors in the projections, which stem from mainly scatter, are estimated by filtering the difference between original line integral and the estimated scatter projections. The corrected CBCT image is then reconstructed from the scatter corrected projections. The proposed method is evaluated on 40 cancer patients. Results: On all patient images, we compare errors on CT number, spatial non-uniformity (SNU) and image contrast, using pCT as the ground truth. T-tests show that our algorithm improves over the Varian method on CBCT accuracies of CT number and SNU with 90% confident. The average CT number error is reduced from 54.8 HU on the Varian method to 40.9 HU, and the SNU error is reduced from 7.7% to 3.8%. There is no obvious improvement on image contrast. Conclusion: Large-group patient studies show that the proposed pCT-based algorithm outperforms the Varian method of the Truebeam system on CBCT shading correction, by providing CBCT images with higher CT number accuracy and greater image uniformity.

60 APPLIED LIFE SCIENCES↗

An angle-dependent estimation of CT x-ray spectrum from rotational transmission measurements

Purpose: Computed tomography (CT) performance as well as dose and image quality is directly affected by the x-ray spectrum. However, the current assessment approaches of the CT x-ray spectrum require costly measurement equipment and complicated operational procedures, and are often limited to the spectrum corresponding to the center of rotation. In order to address these limitations, the authors propose an angle-dependent estimation technique, where the incident spectra across a wide range of angular trajectories can be estimated accurately with only a single phantom and a single axial scan in the absence of the knowledge of the bowtie filter. Methods: The proposed technique uses a uniform cylindrical phantom, made of ultra-high-molecular-weight polyethylene and positioned in an off-centered geometry. The projection data acquired with an axial scan have a twofold purpose. First, they serve as a reflection of the transmission measurements across different angular trajectories. Second, they are used to reconstruct the cross sectional image of the phantom, which is then utilized to compute the intersection length of each transmission measurement. With each CT detector element recording a range of transmission measurements for a single angular trajectory, the spectrum is estimated for that trajectory. A data conditioning procedure is used to combine information from hundreds of collected transmission measurements to accelerate the estimation speed, to reduce noise, and to improve estimation stability. The proposed spectral estimation technique was validated experimentally using a clinical scanner (Somatom Definition Flash, Siemens Healthcare, Germany) with spectra provided by the manufacturer serving as the comparison standard. Results obtained with the proposed technique were compared against those obtained from a second conventional transmission measurement technique with two materials (i.e., Cu and Al). After validation, the proposed technique was applied to measure spectra from the clinical system across a range of angular trajectories [−15°, 15°] and spectrum settings (80, 100, 120, 140 kVp). Results: At 140 kVp, the proposed technique was comparable to the conventional technique in terms of the mean energy difference (MED, −0.29 keV) and the normalized root mean square difference (NRMSD, 0.84%) from the comparison standard compared to 0.64 keV and 1.56%, respectively, with the conventional technique. The average absolute MEDs and NRMSDs across kVp settings and angular trajectories were less than 0.61 keV and 3.41%, respectively, which indicates a high level of estimation accuracy and stability. Conclusions: An angle-dependent estimation technique of CT x-ray spectra from rotational transmission measurements was proposed. Compared with the conventional technique, the proposed method simplifies the measurement procedures and enables incident spectral estimation for a wide range of angular trajectories. The proposed technique is suitable for rigorous research objectives as well as routine clinical quality control procedures.

61 RADIATION PROTECTION AND DOSIMETRY↗

Noise, sampling, and the number of projections in cone-beam CT with a flat-panel detector

Purpose: To investigate the effect of the number of projection views on image noise in cone-beam CT (CBCT) with a flat-panel detector. Methods: This fairly fundamental consideration in CBCT system design and operation was addressed experimentally (using a phantom presenting a uniform medium as well as statistically motivated “clutter”) and theoretically (using a cascaded systems model describing CBCT noise) to elucidate the contributing factors of quantum noise (σ{sub Q}), electronic noise (σ{sub E}), and view aliasing (σ{sub view}). Analysis included investigation of the noise, noise-power spectrum, and modulation transfer function as a function of the number of projections (N{sub proj}), dose (D{sub tot}), and voxel size (b{sub vox}). Results: The results reveal a nonmonotonic relationship between image noise andN{sub proj} at fixed total dose: for the CBCT system considered, noise decreased with increasing N{sub proj} due to reduction of view sampling effects in the regime N{sub proj} <∼200, above which noise increased with N{sub proj} due to increased electronic noise. View sampling effects were shown to depend on the heterogeneity of the object in a direct analytical relationship to power-law anatomical clutter of the form κ/f {sup β}—and a general model of individual noise components (σ{sub Q}, σ{sub E}, and σ{sub view}) demonstrated agreement with measurements over a broad range in N{sub proj}, D{sub tot}, and b{sub vox}. Conclusions: The work elucidates fairly basic elements of CBCT noise in a manner that demonstrates the role of distinct noise components (viz., quantum, electronic, and view sampling noise). For configurations fairly typical of CBCT with a flat-panel detector (FPD), the analysis reveals a “sweet spot” (i.e., minimum noise) in the rangeN{sub proj} ∼ 250–350, nearly an order of magnitude lower in N{sub proj} than typical of multidetector CT, owing to the relatively high electronic noise in FPDs. The analysis explicitly relates view aliasing and quantum noise in a manner that includes aspects of the object (“clutter”) and imaging chain (including nonidealities of detector blur and electronic noise) to provide a more rigorous basis for commonly held intuition and heurism in CBCT system design and operation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Electroformed screens with uniform hole size

Efficient method electroforms fine-mesh nickel screens, or plagues, with uniform hole size and accurate spacing between holes. An electroformed nickel mandrel has nonconducting silicone rubber projections that duplicate the desired hole size and shape in the finished nickel screen.

Schaer, G. R.↗

Generation of Large-Volume High-Pressure Plasma by Spatio-Temporal Control of Space Charge

Due to the fundamental limitations of scaling, very little progress has been made towards achieving a large-volume dense non-equilibrium plasma near atmospheric pressures. Commercially available state-of-the art glow-like atmospheric plasma devices for industrial applications are either narrow tubes or wide slits with narrow openings. Often multiple sources are put together in various configurations to process larger surfaces. The traditional methods of exciting electrodes create spatially fixed electric fields. As a result, the space charge at atmospheric pressure tends to be spatially confined resulting in non-uniformity which eventually leads to instability as the discharge is scaled. Theoretical work done under this project showed that it is possible to generate a spatially rotating electric field by exciting a set of electrodes with phase staggered sinusoidal waveforms. The modeling and simulations were done using plasma fluid models. It was shown that such a field can produce a uniform plasma. At the conclusion of the project, experimental proof of concept with an eight-electrode system in various gases (Air, Helium and Argon) was demonstrated. Power measurements and spectral investigation show that the concept can be used to generate a uniform stable plasma. This plasma source has the potential of opening new applications of nonthermal plasma including combustion of carbon-free fuel. The current limitation of the proposed method in scaling to higher volume and pressure is the need for multiple high voltage amplifiers.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗