Search NASA⌕ Search

SEARCH · Search NASA

Results for “value stacking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Effect of stacking fault energy on damage microstructure in ion-irradiated CoCrFeNiMn concentrated solid solution alloys

In order to understand the effect of stacking fault energy on microstructural evolution in concentrated solid solution alloys, Kr 2+ ion irradiation was performed for FCC-type CoCrFeNiMnx alloys. During Kr 2+ ion irradiation at 500 degrees C the formation of black dots, self-interstitial atom faulted loops and perfect loops were observed, but no observable voids were found in all the alloys. The comparison of microstructural evolution among CoCrFeNiMn x (x = 0.7, 1, 1.3) alloys revealed less faulted loop number density and size in CoCrFeNiMn 1.3 . The stacking fault energy of each alloy was investigated using the deformed CoCrFeNiMn x alloys, and it was revealed that CoCrFeNiMn 1.3 had the highest stacking fault energy, which is higher value than that of 316SS. From these results, it is suggested that FeCrNiMn-based concentrated solid solution alloys could be well-designed by controlling the stacking fault energy with optimized Mn concentration as one of high radiation resistance structure materials. (C) 2020 Elsevier B.V. All rights reserved.

36 MATERIALS SCIENCE↗

Automatic inspection of program state in an uncooperative environment

Abstract The program state is formed by the values that the program manipulates. These values are stored in the stack, in the heap, or in static memory. The ability to inspect the program state is useful as a debugging or as a verification aid. Yet, there exists no general technique to insert inspection points in type‐unsafe languages such as C or C++. The difficulty comes from the need to traverse the memory graph in a so‐called uncooperative environment. In this article, we propose an automatic technique to deal with this problem. We introduce a static code transformation approach that inserts in a program the instrumentation necessary to report its internal state. Our technique has been implemented in LLVM. It is possible to adjust the granularity of inspection points trading precision for performance. In this article, we demonstrate how to use inspection points to debug compiler optimizations; to augment benchmarks with verification code; and to visualize data structures.

Magalhães, José Wesley de Souza↗

Effect of Microstructure Refinement on Hardness Homogeneity of Aluminum Alloy 1100 Processed by Accumulative Roll Bonding

This work examines the effect of grain refinement via accumulative roll bonding (ARB) on the homogeneity of microstructure and hardness through the thickness of commercially pure aluminum AA1100 sheets. The use of 7 cycles of ARB was shown to produce homogeneous ultrafine-grained microstructure, reducing the grain size to 0.46 and 1.03 µm in normal direction and rolling direction, respectively. Examination by electron backscattered diffraction indicates that continuous dynamic recrystallization was the main mechanism for the formation of submicron equiaxed grains bounded with high-angle grain boundaries (HAGBs). The fraction of HAGBs increased gradually reaching a maximum of 71.6% after 7 cycles. Through-thickness hardness measurements using Vickers and nanoindentation tests show an increase from 43.5 Hv (0.85 GPa) for as-received sample to 63 Hv (1.1 GPa) after 7 cycles. The heterogeneity in hardness through the thickness of the as-received material was shown to restrain the evolution of uniform hardness across the sheet thickness with increasing ARB cycles. Tensile tests showed that the tensile strength is increased to 250 MPa, which is about 2 times its initial value. Owing to the high stacking fault energy of AA1100, strong dynamic recovery occurred with increasing ARB strain which was balanced with the strain hardening property of the material. This resulted in plastic instability at small strains and thus early necking during the tensile test.

36 MATERIALS SCIENCE↗

Fragment transition density method to calculate electronic coupling for excitation energy transfer

A general approach, the Fragment Transition Density (FTD) scheme, is introduced to estimate electronic coupling for excitation energy transfer in a molecular system. Within this method, the excitation energies and transition densities of the system are used to derive the coupling matrix element. The scheme allows one to treat systems where exciton donor and acceptor are close together and their exchange interaction and orbital overlap are significant. The FTD method can be applied in combination with any quantum mechanical approach to treat excited states of general nature including single-, double-, and higher excitations. Using FTD approach, we derive excitonic couplings for several systems computed with the CIS, TD DFT and MS-CASPT2 methods. In particular, it is shown that the estimated coupling values in DNA π-stacks are strongly affected by the short-range electronic interaction of adjacent nucleobases.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hanford SMART System: Calculation of Radionuclide Emissions, Ambient Air Concentrations and Error Propagation (Final Report)

This document, authored by Radiological Assessment Corporation (RAC), details the calculations used to convert laboratory radiological analytical sample data and field measurement data for both ambient air samplers and stack air samples to concentration values with associated uncertainty. The RAC supported an effort by Mission Support Alliance (MSA) to replace the Automated Bar Coding of All Samples at Hanford (ABCASH) and Environmental Release Summary (ERS) database software with a commercial off-the-shelf (COTS) data management software system. The ABCASH and ERS databases were not compatible with the Hanford system standards Windows 10 Operating System deployed in calendar year 2018. The replacement software, Sample Management and Analytical Results Tracking (SMART), is used for environmental data collection, analyses, and regulatory reporting for the Hanford Environmental Surveillance and Effluent Monitoring programs.

54 ENVIRONMENTAL SCIENCES↗

Machine learning based unfolding of x-ray spectra from filter stack spectrometer data

We demonstrate the application of neural networks to perform x-ray spectra unfolding from data collected by filter stack spectrometers. A filter stack spectrometer consists of a series of filter-detector pairs, where the detectors behind each filter measure the energy deposition through each layer as photo-stimulated luminescence (PSL). The network is trained on synthetic data, assuming x-rays of energies < 1 MeV and of two different distribution functions (Maxwellian and Gaussian) and the corresponding measured PSL values obtained from five different filter stack spectrometer designs. Predicted unfolds of single distributions are near identical reproductions of the ground truth spectra, with differences in the values lower than 20% at the higher energy end in some cases. The neural network has also demonstrated robustness to experimental measurement errors of < 5% and some capability of performing unfolds for linear combinations of the two distributions without previous training. The network can perform unfolds at rates > 1 Hz, ideal for application to some high-repetition-rate systems.

47 OTHER INSTRUMENTATION↗

Hanford Waste Treatment Plant Low Activity Waste Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation (Rev.1)

The Hanford Tank Waste Treatment and Immobilization Plant Low Activity Waste (LAW) facility stack monitor locations were qualified using scale model stacks to mitigate the risk of discovering that sampling locations do not meet the qualification criteria on the full-scale stacks. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling location were geometrically similar to the actual stack and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the LAW stacks were performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing, determines the range of stack flow rates for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. For this analysis, the range of qualified flow rates listed is conservatively based on the average DV through 6 DV for LV-S1, LV-S2, and LV-C2, and 1/3 DV to 3 DV for LV-S3. Table S1 lists the operating flow rates along with the conservative lower and upper qualified stack flow rates for each of the LAW facility stacks. For each stack, the operating flow is below the upper qualified stack.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Brittle fracture to recoverable plasticity: polytypism-dependent nanomechanics in todorokite-like nanobelts

Atomic force microscopy (AFM) based nanomechanics experiments involving polytypic todorokite-like manganese dioxide nanobelts reveal varied nanomechanical performance regimes such as brittle fracture, near-brittle fracture, and plastic recovery within the same material system. These nanobelts are synthesized through a layer-to-tunnel material transformation pathway and contain one-dimensional tunnels, which run along their longitudinal axis and are enveloped by m × 3 MnO 6 octahedral units along their walls. Depending on the extent of material transformation towards a tunneled microstructure, the nanobelts exhibit stacking disorders or polytypism where the value for m ranges from 3 to up to ~20 within different cross-sectional regions of the same nanobelt. The observation of multiple nanomechanical performance regimes within a single material system is attributed to a combination of two factors: (a) the extent of stacking disorder or polytypism within the nanobelts, and (b) the loading (or strain) rate of the AFM nanomechanics experiment. Controllable engineering of recoverable plasticity is a particularly beneficial attribute for advancing the mechanical stability of these ceramic materials, which hold promise for insertion in multiple next-generation technological applications that range from electrical energy storage solutions to catalysis.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Mercury Dispersion Modeling And Purge Ventilation Stack Height Determination For Tank 40H

The SRNL Atmospheric Technologies Group performed an analysis for mercury emissions from H-Tank Farm - Tank 40 ventilation system exhaust in order to assess whether the Short Term Exposure Limit (STEL), or Threshold Limit Value (TLV) levels for mercury will be exceeded during bulk sludge slurry mixing and sludge removal operations. The American Meteorological Society/Environmental Protection Agency Regulatory Model (AERMOD) was used as the main dispersion modelling tool for this analysis. The results indicated that a 45-foot stack is sufficient to raise the plume centerline from the Tank 40 release to prevent mercury exposure problems for any of the stack discharge scenarios provided. However, a 42-foot stack at Tank 40 is sufficient to prevent mercury exposure concerns in all emission scenarios except the 50 mg/m 3 release. At a 42-foot stack height, values exceeding the exposure standards are only measured on receptors located above 34 feet.

54 ENVIRONMENTAL SCIENCES↗

Assessment of the 3420 Building Filtered Exhaust Stack Sampling Probe Location: Stack Verification Following Fan and Air Blender Additions

The Pacific Northwest National Laboratory (PNNL) 3420 Building, which is part of the Physical Sciences Facility (PSF), houses radiological capabilities that results in the requirement that emissions monitoring must be conducted for potential radionuclides in the exhaust air discharge of this building. The air monitoring system is required to conform to Title 40 of the Code of Federal Regulations part 61 (40 CFR 61) Subpart H, which in turns requires a sampling probe in the exhaust stream to conform to the criteria of American National Standards Institute / Health Physics Society (ANSI/HPS) N13.1-2011, Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stack and Ducts of Nuclear Facilities. To support the air emissions permit for the 3420 Building on the PNNL campus, stack testing that used computational fluid dynamics (CFD) modeling as a surrogate stack and verification tests of velocity uniformity and flow angle on the retrofitted facility stack was performed. The ANSI/HPS N13.1-2011 criteria for the air monitoring probe location are that velocity uniformity, gaseous tracer uniformity, and particulate tracer uniformity must be less than or equal to 20%COV. Furthermore, no point in the sampling location may have a gaseous tracer concentration that varies from the mean concentration by more than 30%. Additionally, the flow angle at the sampling location must not be more than 20°. The CFD modeling of the stack, as reported by Recknagle et al. (2018) demonstrated that the stack meets the criteria at the probe location. The velocity uniformity and flow angle results from the 3420 stack verification tests, performed in October 2020, demonstrated that the CFD model results may be used to support the qualification of the stack sampling location. The measured velocity uniformity verification test result was 1.4%COV. This value is well within the uniformity criterion, which is that the velocity uniformity be =20%COV. Additionally, this value is well within the criterion that the actual stack measurement must be within 5% of the surrogate stack result of 2.1%COV when all four fans were operating. Additionally, the measured average flow angle at the 3420 stack monitor location was 15.5 degrees. Although this is higher than expected based on the CFD model, the result is =20 degrees, so the criterion is met. Based on these stack verification test results, the reconfigured 3420 Building filtered exhaust stack meets the qualification criteria given in the ANSI/HPS N13.1-2011 standard. Further changes to the system configuration or operating conditions that are outside the bounds described in this and the CFD report (Recknagle et al., 2018) may require additional tests and additional analysis to determine compliance with the standard.

3420 Building↗

Assessment of the 3430 Building Filtered Exhaust Stack Sampling Probe Location: Stack Verification Following Fan and Air Blender Additions

The velocity uniformity and flow angle results from the 3430 stack verification tests, performed in April 2023, demonstrated that the CFD model results may be used to support the qualification of the stack sampling location. The measured velocity uniformity verification test result was 2.1 %COV. This value is well within the uniformity criterion, which is that the velocity uniformity be =20 %COV. Additionally, this value is well within the criterion that the actual stack measurement must be within 5% of the surrogate stack (i.e., CFD modeled stack); in this case the CFD modeled average result of 2.85 %COV for the nominal operating range of 22,800 cfm to 62,400 cfm. Additionally, the measured average flow angle at the 3430 stack monitor location was 5.6 degrees. The result is =20 degrees, so the criterion is met.

3430 Building↗

Hanford Waste Treatment Plant LAB Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The Waste Treatment Plant laboratory (LAB) facility stack monitor locations were qualified using scale model stacks to mitigate the risk of identifying that sampling locations do not meet the qualification criteria on the full-scale stack. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling location were geometrically similar to the actual stack, and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the LAB stacks were performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing, determines the range of conditions for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. A practical range for the full-scale stack qualification uses the average DV through 6 DV from the scale model tests to compute the corresponding flow rates. Table S1 lists the operating flow rates along with the average and maximum qualified stack flow rates for each of the LAB facility stacks. For each stack, the operating flow is below the maximum qualified stack flow, which means that the scale model test results are acceptable for stack qualification. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be ≤20°. Second, the velocity uniformity at the full-scale stack must be ≤20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack tests at the LAB facility. Flow angle results were primarily less than 10°, except for the LB-C2 Fan A results, which were an average of 13.7°; all flow angle results were within the ≤20° criterion. The velocity uniformity results for each test condition averaged between 1.5 and 4.1% COV, which were all within the range of the target percent coefficient of variation values from the scale model tests. Based on these stack verification test results, the three LAB filtered exhaust stack sampling locations meet the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all fan operating configurations. This includes single-fan as well as dual-fan operations for LB-C2, each of the dual-fan operating conditions for LB-S1, and each single-fan operating condition for LB-S2. Further changes to the system configuration or operating conditions that are outside the bounds described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Stiffness and thermoelastic coefficients for composite laminates

Simple analytic expressions are presented for the stiffness and thermoelastic coefficients of composite laminates in terms of the material properties of the individual layers. Expressions for the derivatives of the various coefficients with respect to each of the material properties and fiber orientation angles are also included. For typical high-performance composites, numerical values are given showing the effects of the stacking sequence and the fiber orientation angle of quasi-isotropic and angle-ply laminates on the values of the various coefficients and their sensitivity derivatives. The expressions for the thermoelastic coefficients and the sensitivity derivatives are given herein for the first time.

Noor, Ahmed K.↗

Effective work function engineering for a TiN/XO(X = La, Zr, Al)/SiO{sub 2} stack structures

In this study, we demonstrated that work function engineering is possible over a wide range (+200 mV to −430 mV) in a TiN/XO (X = La, Zr, or Al)/SiO{sub 2} stack structures. From ab initio simulations, we selected the optimal material for the work function engineering. The work function engineering mechanism was described by metal diffusion into the TiN film and silicate formation in the TiN/SiO{sub 2} interface. The metal doping and the silicate formation were confirmed by transmission electron microscopy and energy dispersive spectroscopy line profiling, respectively. In addition, the amount of doped metal in the TiN film depended on the thickness of the insertion layer XO. From the work function engineering technique, which can control a variety of threshold voltages (Vth), an improvement in transistors with different V{sub th} values in the TiN/XO/SiO{sub 2} stack structures is expected.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Opportunities and Challenges to Capturing Distributed Battery Value via Retail Utility Rates and Programs

Distributed battery deployment is increasing with advanced metering, control, and communication technologies, leaving electric utilities with an under-utilized, flexible grid resource in aggregate. Rates can reflect locational and temporal prices while utility incentive-based programs allow DERs to provide direct grid services. However, utilities must balance accurately reflecting dynamic grid conditions versus simple and feasible design that encourages customer participation. Currently, most rates and incentive-based programs are simple, but as penetration of DER and advanced controls increase, dynamic designs could become prevalent. Utilities could encourage providing multiple services to optimize distributed battery dispatch and value streams, however, challenges persist when stacking services across distribution and bulk systems. A DER committed to multiple discrete services concurrently necessitates coordination between operators and a clear hierarchy of commitments. One way to address this is to separate commitments by time or capacity. For services that follow cyclic, predictable patterns, or those that are peak driven with predictability, an operator could ensure sufficient state of charge for participation, leaving time where a distributed battery could otherwise provide different services by segmenting participation temporally. To provide continuous or unexpected services, a battery operator may use state of charge management to reserve some percentage of the battery and segment participation by capacity. Macroeconomic trends, load patterns, generation profiles, and grid configurations drive variation in value and the subsequent implications for utility offerings and how a customer might participate. As distributed battery adoption increases, both regulators and utilities will need to ensure no adverse grid impacts and encourage provision of societal value beyond the customer domain.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Comparison of AC Losses of YBCO Circular Pancake Coils and Infinitely Long Stack Approximation

High-temperature superconducting (HTS) coils are key parts of many large-scale AC applications, such as transformers, superconducting magnetic energy storage, and motors. The estimation of AC losses of pancake coils is necessary for optimizing the design of HTS devices and cryogenic systems. To speed up the computation of AC losses, the numerical model of an infinitely long HTS stack is often utilized. An HTS stack is a good approximation of the circular coil only if the coil radius is sufficiently large, since AC losses will exhibit a stronger asymmetry along the radial direction for small values of coil radii. To assess the validation of an infinitely long stack approximation, the comparisons of AC losses between infinitely long stacks and circular coils with different radii are presented. The turn number varies from 10 to 80. We find that the AC losses of HTS circular coils will gradually increase to the same value as an infinitely long stack with increasing coil radii. A new parameter is proposed to quantitatively describe the correctness of infinitely long stack approximation. Finally, a method of AC loss estimation of HTS pancake coils is proposed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Transmembrane Pores Formed by Human Antimicrobial Peptide LL-37

Human LL-37 is a multifunctional cathelicidin peptide that has shown a wide spectrum of antimicrobial activity by permeabilizing microbial membranes similar to other antimicrobial peptides; however, its molecular mechanism has not been clarified. Two independent experiments revealed LL-37 bound to membranes in the {alpha}-helical form with the axis lying in the plane of membrane. This led to the conclusion that membrane permeabilization by LL-37 is a nonpore carpet-like mechanism of action. Here we report the detection of transmembrane pores induced by LL-37. The pore formation coincided with LL-37 helices aligning approximately normal to the plane of the membrane. We observed an unusual phenomenon of LL-37 embedded in stacked membranes, which are commonly used in peptide orientation studies. The membrane-bound LL-37 was found in the normal orientation only when the membrane spacing in the multilayers exceeded its fully hydrated value. This was achieved by swelling the stacked membranes with excessive water to a swollen state. The transmembrane pores were detected and investigated in swollen states by means of oriented circular dichroism, neutron in-plane scattering, and x-ray lamellar diffraction. The results are consistent with the effect of LL-37 on giant unilamellar vesicles. The detected pores had a water channel of radius 2333 {angstrom}. The molecular mechanism of pore formation by LL-37 is consistent with the two-state model exhibited by magainin and other small pore-forming peptides. The discovery that peptide-membrane interactions in swollen states are different from those in less hydrated states may have implications for other large membrane-active peptides and proteins studied in stacked membranes.

59 BASIC BIOLOGICAL SCIENCES↗

Fluorescence Quenching of Dyes by Graphene Oxide

Fluorescence quenching of four dyes [acridine orange (AO), rhodamine B (Rd B), rhodamine 110 (Rd 110), and rhodamine 640 (Rd 640)] by colloidal graphene oxide (GO) in phosphate buffer (pH 6.0) was studied. Dynamic and static quenching were analyzed using the Stern–Volmer equation. Static quenching by graphene oxide was observed for AO, Rd 640, and Rd B whereas mixed dynamic and static quenching was characteristic of Rd 110. The Stern–Volmer constant of dynamic quenching was 10 times less than that of static quenching. The measured association constants of the dyes with GO fell in the order 2540 (AO) > 495 (Rd 640) > 260 (Rd 110) > 144 L/g (Rd B). The value of the π–π-stacking interaction was strongly influenced by the phthalic fragment oriented perpendicular to the xanthene in the rhodamine dyes and the four alkyl groups of Rd B as a result of their torsional vibrations and rotational motions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗