Resilient cooling through geothermal district energy system

Decarbonization and resilience to heat waves have recently become high priorities for building and district energy systems. Geothermal coupled district heating and cooling systems that operate a water loop near ground temperature gain increasing adoption to support decarbonization. In these systems, vapor-compression machines, distributed in the energy transfer stations, lift the temperature up or down to the needs of the particular building. In principle, these systems can provide low-power, free cooling from the geothermal bore field during heat waves when electricity is often scarce. However, the performance of such a resilience operation mode and its implication on the energy system configuration and the sizing of the bore field and HVAC equipment is not yet understood. Consequently, we are assessing their resilience, power use and design implications under a scenario of a heat wave on five working days during which chillers are switched off to reduce electrical consumption. Our analysis is based on high-fidelity, coupled dynamic models of district energy, building-side HVAC and actual control logic, with whole building energy simulation used to assess thermal conditions in a 2004 vintage multi-zone office building in Chicago, IL. The results show that relying only on waterside economizer cooling, the indoor thermal conditions can be maintained in a tolerable range for the majority of the building zones with half the electrical energy compared to standard chiller operation. Thermal comfort in the hottest zones can be further improved by oversizing the cooling coil. However, the waterside economizer has significant implications on the system configuration and sizing: The geothermal bore field needs to be sized about 30% larger than the upper limit of the range observed for conventional geothermal systems. Nevertheless, if a central chiller plant is added, the bore field can be downsized to the typical design range. The latter configuration still allows compressor-less cooling during the heat wave with peak power reduced by 60% compared to the standard design and chiller operation.

15 GEOTHERMAL ENERGY↗

Evaluation of Brine Processing Technologies for Spacecraft Wastewater

Brine drying systems may be used in spaceflight. There are several advantages to using brine processing technologies for long-duration human missions including a reduction in resupply requirements and achieving high water recovery ratios. The objective of this project was to evaluate four technologies for the drying of spacecraft water recycling system brine byproducts. The technologies tested were NASA's Forward Osmosis Brine Drying (FOBD), Paragon's Ionomer Water Processor (IWP), NASA's Brine Evaporation Bag (BEB) System, and UMPQUA's Ultrasonic Brine Dewatering System (UBDS). The purpose of this work was to evaluate the hardware using feed streams composed of brines similar to those generated on board the International Space Station (ISS) and future exploration missions. The brine formulations used for testing were the ISS Alternate Pretreatment and Solution 2 (Alt Pretreat). The brines were generated using the Wiped-film Rotating-disk (WFRD) evaporator, which is a vapor compression distillation system that is used to simulate the function of the ISS Urine Processor Assembly (UPA). Each system was evaluated based on the results from testing and Equivalent System Mass (ESM) calculations. A Quality Function Deployment (QFD) matrix was also developed as a method to compare the different technologies based on customer and engineering requirements.

recycling↗

Thermoeconomic Evaluation and Optimization of Using Different Environmentally Friendly Refrigerant Pairs for a Dual-Evaporator Cascade Refrigeration System

Applications of dual-evaporator refrigeration systems have recently gained much attention both in academia and industry due to their multiple benefits. In this study, a comprehensive thermodynamic and economic analysis is conducted to evaluate the potential of using several environmentally friendly refrigerant couples and identifies the most suitable one yielding the best economic results. To achieve this goal, a detailed parametric study is conducted, and an optimization process is performed using a particle swarm optimization (PSO) approach to minimize the unit production cost of cooling (UPCC) of the cascade refrigeration system. The results showed that among all selected 18 refrigerant pairs and for all ranges of examined operating parameters, the R170-R161 pair and R1150-R1234yf pair are identified as the best and worst pairs, respectively, from both thermodynamic and economic viewpoints. The results also confirm that R170-R161 pair has an improvement over R717-R744, used as a typical refrigerant pair of cascade refrigeration cycles. For a base case analysis, the COP of R170-R161 and R1150-R1234yf pairs is determined as 1.727 and 1.552, respectively, while their UPCC is found to be $0.395/ton-hr and $0.419/ton-hr, respectively, showing the influence of proper selection of refrigerant pairs on the cascade cycle’s performance. Overall, this study offers a useful thermodynamic and economic insight regarding the selection of proper refrigerant pairs for a dual-evaporator cascade vapor compression refrigeration system.

42 ENGINEERING↗

A review on nearly isothermal compression technology

Compressors can be described as the heart of a vapor compression refrigeration system, circulating the working fluid in the system. Significant benefits can be gained from improving its efficiency since energy consumption is responsible for almost the entire system's power input. An effort has been made to achieve isothermal compression through liquid refrigerant injection or inter-stage cooling in refrigeration systems. In recent years, much effort has been invested into isothermal compression technology for air compressors or compressed air energy storage systems with the rise of renewable energy. Here, this work has explored the advancements made in this area and categorized them to discuss the benefits, limitations, and tradeoffs. Evidently, increasing heat transfer area is a significant aid in improving heat transfer, resulting in better isothermal compression. However, liquid pistons open more avenues for this to be pursued, and therefore, are limited to air compression applications. In addition, water injection proved to be the most effective among the methods. Finally, there is a need for more experimental research on refrigeration applications and the field is still in its infancy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling and Simulation of Air-Source CO2 Heat Pump Water Heater

Carbon dioxide (CO2) has been widely used as working fluid for the vapor-compression refrigeration systems in large marine device. Due to the potential energy efficiency and the favorable environmental properties of CO2 as a working fluid, CO2 heat pump water heater (HPWH) systems are regarded a promising technology for centralized domestic hot water (DHW) heating in residential and commercial buildings. However, there is still at the early stage of appropriately optimizing and improving the energy performance of CO2 HPWH. This requires CO2 HPWH simulation tools capable of capturing the accurate impact of the emerging compressor, throttle device, and heat exchanger technology on CO2 heat transfer and energy efficiency. In this study, high efficiency components (compressors, pumps, fans, heat exchangers) were identified and applied to the state-of-art CO2 HPWH designs and analyzed their performance by using numerical simulation. This was done by simulating the performance of CO2 HPWH using ACMODEL design model combined with the component models developed at Oak Ridge National Laboratory (ORNL) for orifice tube, map-based compressor, and tube-in-tube gas cooler. ACMODEL is an equipment design model for CO2-based air conditioners and heat pumps developed by Purdue University to account for the details of each component. The simulated CO2 HPWH performance was then compared with the heat pump water heater using conventional refrigerants.

Gao, Zhiming↗

Equivalent Mass Benefits from Employing Vapor Compression Refrigeration on Spacecraft

Thermoelectric cooling, reversed Brayton cycles and Stirling cycle devices are common cooling technologies employed on spacecraft where temperatures below the radiator temperature are needed. Although used less often in microgravity, vapor compression refrigeration was proposed for microgravity applications as early as the 1970s. Researchers proposed the vapor compression cycle over other cooling technologies for its superior energy efficiency in the typical refrigerator/freezer and air-conditioning temperature range. The higher energy efficiency should alleviate the mass penalty of the thermal system, conceivably both for satellites and manned spacecraft. Despite numerous propositions, the literature lacks a discussion of the absolute equivalent mass benefit achievable and the value of it relative to the total mass of the thermal system of the spacecraft or the spacecraft itself. This paper presents the equivalent mass benefits of employing a vapor compression system over other cooling technologies using a mass penalty factor for power consumption. Additionally, a prototype vapor compression cooler sized to fit into an ISS locker is presented.

refrigerator↗

An Evaluation of the Vapor Phase Catalytic Ammonia Removal Process for Use in a Mars Transit Vehicle

An experimental program has been developed to evaluate the potential of the Vapor Phase Catalytic Ammonia Reduction (VPCAR) technology for use as a Mars Transit Vehicle water purification system. Design modifications which will be required to ensure proper operation of the VPCAR system in reduced gravity are also evaluated. The VPCAR system is an integrated wastewater treatment technology that combines a distillation process with high temperature catalytic oxidation. The distillation portion of the system utilizes a vapor compression distillation process to provide an energy efficient phase change separation. This portion of the system removes any inorganic salts and large molecular weight, organic contaminates, i.e., non-volatile, from the product water stream and concentrates these contaminates into a byproduct stream. To oxidize the volatile organic compounds and ammonia, a vapor phase, high temperature catalytic oxidizer is used. This catalytic system converts these compounds along with the aqueous product into CO2, H2O, and N2O. A secondary catalytic bed can then be used to reduce the N2O to nitrogen and oxygen (although not evaluated in this study). This paper describes the design specification of the VPCAR process, the relative benefits of its utilization in a Mars Transit Vehicle, and the design modification which will be required to ensure its proper operation in reduced gravity. In addition, the results of an experimental evaluation of the processors is presented. This evaluation presents the processors performance based upon product water purity, water recovery rates, and power.

Flynn, Michael↗

Effect of geometry and operational parameters on the dehumidification performance of a desiccant coated heat exchanger

Solid desiccant dehumidification systems are an alternative to vapor-compression-based air dehumidification systems. They use solid desiccant materials to adsorb air moisture in space cooling. DCHE can integrate the cooling component in the heat exchanger to achieve higher dehumidification capacity. Comprehensive numeric modeling would be necessary to assist in the design and operation of the DCHE under development to achieve maximum performance. Here, we provide the details of a heat and mass transfer model developed for this purpose. The model aims to cover a gap in existing models by independently modeling heat transfer on the solid desiccant, fin, and tube. The model results were compared with an experimental reference for validation. The air outlet humidity and temperature results for dehumidification and regeneration showed a deviation lower than 15% from the experiment. The validated model was used to perform a parametric study for a series of design and operating conditions. The parametric analysis showed that an increase of 25% in desiccant layer thickness and thermal contact resistance between solid elements reduces moisture removal by 9.1% and 1%, respectively. These results indicate the need to independently model the desiccant layer.

42 ENGINEERING↗

Evaluation of hybrid evaporative-vapor compression air conditioners for different global climates

Currently, a majority of global residential air-conditioning requirements are met using cooling systems based on the vapor compression cycle (VCC). To meet the future demand for space cooling and to reduce the corresponding environmental impact, there is a need for alternative cooling systems which require less resources and exhibit a higher coefficient of performance (COP). One of proposed alternatives is called the hybrid evaporative-vapor compression (HEVC) cycle, which utilizes adiabatic latent cooling in combination with the VCC. In this paper, we conducted a feasibility analysis of a HEVC system by comparing its performance to that of VCC for various global climates. To accomplish this, we developed and validated models to simulate the performance of residential VCC and HEVC systems. ASHRAE weather data and design conditions were then used to compare the performance of the two systems. In general, HEVC systems are best suited for hot arid climates with energy reduction greater than 20%. Conversely, humid climates are not suitable for HEVC adoption due to degraded performance of evaporative coolers in these climates. In addition to comparing the energy savings from HEVC systems, it is also critical to analyze their water consumption. Generally, climates that benefit the most from HEVC technology tend to also experience water scarcity issues. Thus, both the energy savings and water consumption of HEVC systems must be analyzed to guide the discussion on their adoption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design and the parametric testing of the space station prototype integrated vapor compression distillation water recovery module

Potable water for the Space Station Prototype life support system is generated by the vapor compression technique of vacuum distillation. A description of a complete three-man modular vapor compression water renovation loop that was built and tested is presented; included are all of the pumps, tankage, chemical post-treatment, instrumentation, and controls necessary to make the loop representative of an automatic, self-monitoring, null gravity system. The design rationale is given and the evolved configuration is described. Presented next are the results of an extensive parametric test during which distilled water was generated from urine and urinal flush water with concentration of solids in the evaporating liquid increasing progressively to 60 percent. Water quality, quantity and production rate are shown together with measured energy consumption rate in terms of watt-hours per kilogram of distilled water produced.

Reveley, W. F.↗

Review of Vapor Compression Refrigeration in Microgravity Environments

Using a vapor compression cycle for cooling in microgravity environments was already suggested in the 1970s to leverage the high coefficient of performance. Since then, only a few systems have operated in microgravity with scarce documentation of these flights. The lack of measured data and detailed documentation makes identifying the necessary next steps difficult for researchers entering the field of refrigeration in space. This paper provides a review of available literature for vapor compression systems flown in microgravity by outlining the history of vapor compression devices in space and presenting performance data. Moreover, gaps in the literature are highlighted and open questions are posed based on the reviewed material. Next steps of research are suggested to support and ultimately achieve reliable vapor compression refrigeration in space. Calculating equivalent masses for a fair comparison of different microgravity cooling technologies is proposed by capturing both energy consumption and used volume.

Vapor compression↗

Design of Phase-Change Thermal Storage Device in a Heat Pump for Building Electric Peak Load Shaving: Preprint

Replacing carbon-intensive fossil fuel heating systems with electric heat pumps powered by renewables is a promising approach to decarbonize the building sector. However, one of the technical barriers of this approach is the large scale of heat demand, which will put excessive stress on the electricity grid. Integrating thermal energy storage (TES) into the heating systems can help alleviate this problem, by shifting thermal load and thus shaving peaks in the building electric load. Therefore, it is critical to understand how to design a thermal storage device in a heat pump for peak load shaving. In this study, we developed a numerical model for a cascaded vapor compression heat pump system integrating a phase change thermal storage device. This novel system can control the net thermal charging and discharging rate of the TES independently from the building's thermal load, which allows for precise control of electric power use. In the current study, we controlled the system to shave building electric peak load during a cold winter morning, and to charge TES during the relatively warm afternoon while still providing space heating. We used the model to evaluate the system performance with and without peak shaving. We also investigated the effect of PCM transition Tt on the peak reduction and electric energy saving potentials. The results show that peak shaving scheme effectively reduces the peak electric power consumption during a predefined discharge time window. When comparing to the no shaving case, for PCM Tt = 10 degrees C, the peak electric load reduction is 23.5%. When comparing to an air-source heat pump with back up electric heater, as Tt increases from 0 to 20 degrees C, the peak reduction increases from 46.1% to 50.9%. Integrating PCM Tt = 10 degrees C with peak shaving leads to the 45.5% of electric energy saving, which is the highest among the three transition temperatures.

electric energy saving↗

An improved high power hybrid capillary pumped loop

In order to improve performance testing, NASA's High-Power Spacecraft Thermal Management system has been modified through (1) an augmentation of heat-dissipation capacity of the condenser sink for steady-state high power operation, (2) the addition of more pressure transducers for pressure-drop monitoring in various system components, (3) the installation of pressure-contact thermocouples on the evaporators to measure heating surface temperature, (4) the provision of a coolant loop to one of the evaporator plates, (5) the placing of a transient fluid flow-monitoring load cell in the reservoir, and (6) the reorientation of the reservoir to reduce compressed vapor effects. The system is now capable of 10 hours of continuous capillary mode operation at an input power level of 20 kW.

Ku, Jentung↗

A Comparative Analysis of Phase-Change Wastewater Processing Approaches for Microgravity

Two phase-change wastewater processing candidates, the ISS Vapor Compression Distillation (VCD) System and the Cascade Distiller System (CDS), are compared based on dynamic modeling of both technologies. Differences in fluid handling and energy recovery for the technologies are described and contrasted. Model predictions are presented showing how temperatures, pressures, and compositions vary locally within each distiller. These dynamic variations are difficult to observe experimentally and have implications regarding non-condensable buildup and salt precipitation potential. Alternative architectures involving VCD and CDS components are analyzed in terms of predicted performance and equivalent system mass (ESM). The addition of a downstream brine processor to increase water recovery is also evaluated. Options for reducing overall ESM are discussed, including the possibility of developing a single precipitation-tolerant primary wastewater processor.

Lange, Kevin↗

Electrohydrodynamic (EHD) Refrigerant Pump

An electrohydrodynamic (EHD) pump increases refrigerant flow rate and the resulting pressure in a vapor compression based cooling system for permitting reduced compressor sizes and power demands. The EHD pump disposes electrodes in a liquid path of the refrigerant flow, and increases fluid flow and resulting pressure by an induced liquid flow between a pair of asymmetric electrodes. Voltage applied to these electrodes results in a conduction pumping mechanism associated with heterocharge layers in the vicinity of the electrodes based on disassociation of a neutral electrolyte species in the refrigerant fluid and recombination of the generated ions. The induced flow draws the liquid due to a net fluid flow toward one of the electrodes based on the asymmetry of the electrode pair. Electrodes are disposed on an inner surface of a refrigerant vessel, in communication with an annular liquid film that forms around the inner circumference in two-phase fluid systems.

Yagoobi, Jamal S.↗

Controlled Ecological Life Support Systems (CELSS) physiochemical waste management systems evaluation

Parametric data for six waste management subsystems considered for use on the Space Station are compared, i.e.: (1) dry incineration; (2) wet oxidation; (3) supercritical water oxidation; (4) vapor compression distillation; (5) thermoelectric integrated membrane evaporation system; and (6) vapor phase catalytic ammonia removal. The parameters selected for comparison are on-orbit weight and volume, resupply and return to Earth logistics, power consumption, and heat rejection. Trades studies are performed on subsystem parameters derived from the most recent literature. The Boeing Engineering Trade Study (BETS), an environmental control and life support system (ECLSS) trade study computer program developed by Boeing Aerospace Company, is used to properly size the subsystems under study. The six waste treatment subsystems modeled in this program are sized to process the wastes for a 90-day Space Station mission with an 8-person crew, and an emergency supply period of 28 days. The resulting subsystem parameters are compared not only on an individual subsystem level but also as part of an integrated ECLSS.

Oleson, M.↗

Preliminary design package for solar heating and cooling systems

Summarized preliminary design information on activities associated with the development, delivery and support of solar heating and cooling systems is given. These systems are for single family dwellings and commercial applications. The heating/cooling system use a reversible vapor compression heat pump that is driven in the cooling mode by a Rankine power loop, and in the heating mode by a variable speed electric motor. The heating/cooling systems differ from the heating-only systems in the arrangement of the heat pump subsystem and the addition of a cooling tower to provide the heat sink for cooling mode operation.

Source record↗

Vapor Compression and Thermoelectric Heat Pump Heat Exchangers for a Condensate Distillation System: Design and Experiment

Maximizing the reuse of wastewater while minimizing the use of consumables is critical in long duration space exploration. One of the more promising methods of reclaiming urine is the distillation/condensation process used in the cascade distillation system (CDS). This system accepts a mixture of urine and toxic stabilizing agents, heats it to vaporize the water and condenses and cools the resulting water vapor. The CDS wastewater flow requires heating and its condensate flow requires cooling. Performing the heating and cooling processes separately requires two separate units, each of which would require large amounts of electrical power. By heating the wastewater and cooling the condensate in a single heat pump unit, mass, volume, and power efficiencies can be obtained. The present work describes and compares two competing heat pump methodologies that meet the needs of the CDS: 1) a series of mini compressor vapor compression cycles and 2) a thermoelectric heat exchanger. In the paper, the system level requirements are outlined, the designs of the two heat pumps are described in detail, and the results of heat pump performance tests are provided. A summary is provided of the heat pump mass, volume and power trades and a selection recommendation is made.