Search NASA⌕ Search

SEARCH · Search NASA

Results for “voltage loss analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Toward quantifying capacity losses due to solid electrolyte interphase evolution in silicon thin film batteries

To understand the origins of failure and limited cycle life in lithium-ion batteries (LIBs), it is imperative to quantitatively link capacity-fading mechanisms to electrochemical and chemical processes. This is extremely challenging in real systems where capacity is lost during each cycle to both active material loss and solid electrolyte interphase (SEI) evolution, two indistinguishable contributions in traditional electrochemical measurements. Here, we have used a model system in combination with (1) precision measurements of the overall Coulombic efficiency via electrochemical experiments and (2) x-ray reflectivity measurements of the active material losses. The model system consisted of a 515 Å thick amorphous silicon (a-Si) thin film on silicon carbide in half-cell geometry using a carbonate electrolyte with LiPF6 salt. This approach allowed us to quantify the capacity lost during each cycle due to SEI evolution. Combined with electrochemical analysis, we identify SEI growth as the major contribution to capacity fading. Specifically, the continued SEI growth results in increasing overpotentials due to increased SEI resistance, and this leads to lower extent of lithiation when the cutoff voltage is reached during lithiation. Our results suggest that SEI grows more with increased time spent at low voltages where electrolyte decomposition is favored. Finally, we extracted a proportionality constant for SEI growth following a parabolic growth law. Our methodology allows for the quantitative determination of lithium-ion loss mechanisms in LIBs by separately tracking lithium ions within the active materials and the SEI and offers a powerful method of quantitatively understanding LIB loss mechanisms.

25 ENERGY STORAGE↗

TRANSENSOR: Transformer Real-time Assessment INtelligent System with Embedded Network of Sensors and Optical Readout. Final Report

Utilities across the world are wrestling with evolving market dynamics, population growth and climate change. Distributed Energy Resources (DERs) such as solar photovoltaics, distributed generators and energy storage systems are becoming important parts of the U.S. energy mix. These factors are driving an increasing need for low-cost grid asset monitoring. Aside from being costly, traditional utility monitoring systems are not sufficiently robust and do not provide real-time visibility into the condition of grid assets such as transformers. Lack of accurate real-time measurements on performance has resulted in the use of lagging indicators, such as oil sample analysis. To address this need, an innovative embedded optical sensing technology, Transformer Real-time Assessment Intelligent System (TRANSENSOR) was developed, validated and demonstrated in this project. To date, TRANSENSOR has focused on transformers but is extendable to other grid assets. In addition to the technology being embedded into new transformers during manufacturing, a retrofit configuration that can be installed on existing transformers in the field was also developed. It is anticipated that the ability to retrofit existing transformers will help accelerate adoption of the underlying TRANSENSOR technology. Phase 1 of the project focused on laboratory development and qualification of the technology. Following iterations and exploration of relevant optical sensing modalities and multiplexed configurations of interest for the transformer environment, an effective candidate configuration was agreed upon, down-selected and custom-designed for embedding into General Electric (GE) network transformers. Two new GE 500 kilovolt ampere (kVA), 27 kilovolt (kV) distribution network transformers were built with embedded fiber-optic (FO) sensors and successfully qualified per industry standards at GE’s Shreveport, Louisiana facility during Phase 1 of the project. Following the successful completion of Phase 1, the team proceeded to Phase 2, which focused on a field demonstration of the technology. Over Phase 2, the first new GE transformer built with embedded fiber-optic sensors was installed in an above-ground cage and connected to the grid at Con Edison’s Astoria facility. A second transformer equipped with TRANSENSOR was installed in an underground vault. Additionally, an older (1982 year model) GE transformer in an above-ground cage was retrofitted with fiber- optic sensors and reconnected to the grid at ConEd’s facility. Analysis of data acquired from the sensors showed interesting correlations with transformer loading. Additionally, key events such as transformer low-voltage network connection, primary-side energizing, and a pressure loss event from an oil sampling were detected by the TRANSENSOR system. Online data processing/feature extraction algorithms for the second transformer in the underground vault detected key features and event alerts that were transmitted through a wireless 4G connection. The remote deployment concept showed promising results with data collection running for a total of 8 months across the three (3) GE transformers instrumented for the Phase 2 field demonstration. This sets the stage well for further development and commercialization.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multiscale Electrothermal Design of a Modular Multilevel Converter for Medium-Voltage Grid-Tied Applications

As a key feature of modular multilevel converters (MMCs), a large number of semiconductor devices are employed in the converter and distributed over a stack of submodules. Each submodule has a strict temperature limit that imposes constraints on the operating range of the converter. Different loading conditions/losses in the submodules lead to unavoidable temperature variations inside the MMC, which consequently affect the system-level performance and reliability. This paper is focused on the electrothermal analysis and design of a medium-voltage silicon carbide (SiC)-based MMC system, from submodule power semiconductors to the overall MMC system integration of multiple submodules, for grid-connected applications. Loss calculations are performed to estimate the cooling requirements and aid thermal design at different levels. The performance of a forced-air cooling approach is analyzed within a numerical modeling framework. Maximum temperature of the SiC power modules is predicted using numerical tools. Thermal design of the MMC cabinet with various arrangements of air inlet(s) and outlet(s) is investigated and compared from a cooling performance perspective. A fully resolved model of the arrangement that yields optimal results is developed to accurately predict the temperature profile of the essential components in the submodules.

computational fluid dynamics↗

Comparative Investigation of System-Level Optimized Power Conversion System Architectures to Reduce LCOE for Large-Scale PV-Plus-Storage Farms

PV-plus-storage (PVS) has become a prevalent configuration for newly commissioned large-scale solar projects. However, the optimal power conversion system (PCS) architecture has not been investigated yet. This paper first validates the limited impact of inverter cost on LCOE and then explores a system-level optimized PCS architecture with extended LCOE reduction to proliferate large-scale dispatchable solar energy. Two state-of-the-art architectures including central inverters (CI), traditional 480/600 V string inverters (SI) are compared with newly proposed medium voltage string inverters (MVSI) and multiport DC transformer (MDCT). With verified layouts and single line diagrams (SLDs) of 20 MW PVS plants, the losses and costs breakdown of different architectures are extracted and the PCS related LCOEs are derived. In this analysis, all electrical bill of materials (EBOS) elements, inverters, battery storage and its associated components, are included, whose losses and costs are obtained from markets, manufacturers, and literature. Besides, the sensitivities of PCS-related LCOEs to Inverter-Loading-Ratio (ILR) are also investigated. Here, the results show that compared with CI and SI with 1.5 kV PV, 4 kV MVSI and 34 kV MDCT present an extended LCOE reduction across all ILR from 1.0 to 3.0, making them economically favorable candidates for PVS farms.

14 SOLAR ENERGY↗

Rapid Inverse Parameter Inference Using Physics-Informed Neural Network

As Li-ion batteries become more essential in today's economy, tools need to be developed to accurately and rapidly diagnose a battery's internal state-of-health. Using a Li-ion battery's (high-rate) voltage response, it is proposed to determine a battery's internal state through Bayesian calibration. However, Bayesian calibration is notoriously slow and requires thousands of model runs. To accelerate parameter inference using Bayesian calibration, a surrogate model is developed to replace the underlying physics-based Li-ion model. Developing a surrogate model for rapid Bayesian calibration analysis is discussed for both the single particle model (SPM) and the pseudo two-dimensional (P2D) model. Surrogate models are constructed using physics-informed neural networks (PINNs) that encode the influence of internal properties on observed voltage responses. In practice, a neural network can be trained by: 1) using simulation results of the physics-based model (i.e., a data-loss approach); 2) using the residuals of the governing equations themselves (i.e., a physics-loss approach); or 3) using a combination of simulation results and governing equation residuals. In the present work, PINNs are developed using a variety of training losses and neural network architectures. In this analysis, it is shown that a PINN surrogate model can be reliably trained with only physics-informed loss. However, using a coupled data-informed and physics-loss approach produced the most accurate PINNs.

Bayesian calibration↗

A Digital Twin Framework for Liquid-cooled Supercomputers as Demonstrated at Exascale

We present ExaDigiT, an open-source framework for developing comprehensive digital twins of liquid-cooled supercomputers. It integrates three main modules: (1) a resource allocator and power simulator, (2) a transient thermo-fluidic cooling model, and (3) an augmented reality model of the supercomputer and central energy plant. The framework enables the study of "what-if" scenarios, system optimizations, and virtual prototyping of future systems. Using Frontier as a case study, we demonstrate the framework's capabilities by replaying six months of system telemetry for systematic verification and validation. Such a comprehensive analysis of a liquid-cooled exascale supercomputer is the first of its kind. ExaDigiT elucidates complex transient cooling system dynamics, runs synthetic or real workloads, and predicts energy losses due to rectification and voltage conversion. Throughout our paper, we present lessons learned to benefit HPC practitioners developing similar digital twins. We envision the digital twin will be a key enabler for sustainable, energy-efficient supercomputing.

Brewer, Wes↗

Analysis and Control of a Three-Port Converter with High-Frequency AC Link for Hybrid Unmanned/Autonomous Aerial Vehicles

In this study, a three-port resonant converter with a high-frequency isolation link for hybrid unmanned/autonomous aerial vehicle (UAV/AAV) applications is analyzed. The rectified engine-generator set output supplies the first input ports while the other is connected to a battery energy storage system. Input ports consist of half-bridge high-frequency inverters, whereas output port utilizes a semi-bridgeless active rectifier. This rectifier is formed by replacing rectifier low-side diodes with active switching devices. A phase-shift duty-cycle control is implemented for switching signals to regulate the power share and flow between ports. The proposed control system implemented achieves zero voltage switching (ZVS), reduces switching losses, and minimum current flow optimization ensures regulation in a wide range of output power. Compared to the existing bidirectional pulse width modulation (PWM) converters, the proposed system decreases the number of power conversion stages and provides centralized control without needing communications between the ports. The proposed control technique operating in closed-loop control achieves the power flow between ports under various load conditions. Finally, theoretical analysis demonstrates the proposed converter’s viability and laboratory experimental validations at 500 W full power.

33 ADVANCED PROPULSION SYSTEMS↗

Grid-Tied PV Inverter with Oversized Power Module to Increase its Low-Voltage Ride Through (LVRT) Capabilities and VAR Support

This paper proposes a novel design for grid-tied 3-ph Photovoltaic (PV) inverter to improve its low-voltage ride through (LVRT) response while significantly increasing its voltampere reactive (VAR) support during voltage sags. The literature available on LVRT for PV inverters can be grouped in solutions that dissipate the excess energy and those that temporary stores this energy. This paper proposes a third solution; oversizing inverter hardware components to safely transferring all the energy excess back to while maintaining the semiconductor under the maximum temperature limits. The advantages of the proposed approach are: 1) Improved LVRT capabilities and stable dc-link voltage control at MPP during sags. 2) Increased VAR support during voltage sags. 3) Increased use of renewable energy as all active power is injected back to the grid during voltage sags. Finally, the proposed solution is more cost effective compared with solutions that incorporate energy storage because only a few inverter components are required to be oversized. This paper also presents a detailed power loss analysis, which determined that that oversizing the power semiconductors has minimal impact in the inverter losses while significatively reducing the diode and IGBT conduction losses during both normal operation and grid fault conditions.

Ferrari Maglia, Max↗

The influence of electrochemical cycling protocols on capacity loss in nickel-rich lithium-ion batteries

The transition towards electric vehicles and more sustainable transportation is dependent on lithium-ion battery (LIB) performance. Ni-rich layered transition metal oxides, such as NMC811 (LiNi 0.8 Mn 0.1 Co 0.1 O 2 ), are promising cathode candidates for LIBs due to their higher specific capacity and lower cost compared with lower Ni content materials. However, complex degradation mechanisms inhibit their use. In this work, tailored aging protocols are employed to decouple the effect of electrochemical stimuli on the degradation mechanisms in graphite/NMC811 full cells. Using these protocols, impedance measurements, and differential voltage analysis, the primary drivers for capacity fade and impedance rise are shown to be large state of charge changes combined with high upper cut-off voltage. Focused ion beam-scanning electron microscopy highlights that extensive microscale NMC particle cracking, caused by electrode manufacturing and calendering, is present prior to aging and not immediately detrimental to the gravimetric capacity and impedance. Scanning transmission electron microscopy electron energy loss spectroscopy reveals a correlation between impedance rise and the level of transition metal reduction at the surfaces of aged NMC811. The present study provides insight into the leading causes for LIB performance fading, and highlights the defining role played by the evolving properties of the cathode particle surface layer.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Coordinated Market Design for Peer-to-Peer Energy Trade and Ancillary Services in Distribution Grids

A novel peer-to-peer (P2P) market design is proposed in this work for the distribution grid level. Envisioning that the grid constraints violations are the major challenge for P2P energy sharing, we propose they are handled through the ancillary service (AS) market. By calculating the decomposable distribution locational marginal prices (DLMPs), the essential price signals of procuring AS can be recovered to determine the grid usage prices (GUPs) to each P2P transaction. Hence, the GUPs, due to their decomposable properties, act as incentive signals for the P2P market to support the grid operation in terms of loss reduction, voltage support and congestion management. The proposed market design comprises: i) an interactive market design of P2P trade & AS and, ii) a fully decentralized peer-centric market clearing model for P2P energy trade. The duality analysis provides the composition of market equilibrium prices of P2P trading and their interpretations. The case studies demonstrate the effectiveness of the proposed P2P trade to support grid operational objectives.

Zhang, Kai↗

Editors’ Choice—Ionomer Side Chain Length and Equivalent Weight Impact on High Current Density Transport Resistances in PEMFC Cathodes

Cell voltage at high current densities (HCD) of an operating proton-exchange membrane fuel cell (PEMFC) suffers from losses due to the local-O 2 and bulk-H + transport resistances in the cathode catalyst layer (CCL). Particularly, the interaction of perfluorosulfonic acid (PFSA) ionomer with the carbon supported platinum catalyst plays a critical role in controlling reactant transport to the active site. In this study, we perform a systematic analysis of the side chain length and equivalent weight (EW) of PFSA ionomers on the CCL transport resistances. Ex situ measurements were carried out to quantify the ionomer characteristics such as the molecular weight, proton conductivity and water uptake. Nanomorphology of ionomers cast as 60–120 nm thin-films is characterized using grazing-incidence X-ray scattering. In situ fuel cell electrochemical diagnostic measurements were carried out to quantify the reactant (H + /O 2 ) transport properties of the CCL. Ionomer EW was found to play a major role with decreasing EW yielding higher proton conductivity and water uptake that led to lower bulk-H + and local-O 2 transport resistances in the CCL. Finally, a 1D-semi-empirical performance model has been developed to quantify the impact of ionomer EW on cell voltage loss factors.

08 HYDROGEN↗

CdTe Core: Final Technical Report (FTR)

CdTe is presently the cost-leading thin-film PV technology, directly competing with Si at scale, even when domestically manufactured. While an impressive technology, its efficiency remains much below the detailed balance limit with the largest cause due to its low photovoltage and fill factor. To realize gains, the carrier concentration, minority carrier lifetime, and interface recombination all need to be improved simultaneously over historic levels. Using a new defect chemistry (group V doping instead of copper) has been identified as a viable route using single crystal systems. This project focused on implementing this new defect chemistry in scalable, polycrystalline thin-film photovoltaic CdTe devices with tasks focusing improvements to the front interface, absorber, and rear interface as well as capability development & stakeholder engagement. The goal of the project was to establish a strategy using devices, test structures, detailed characterization, and modeling to quantify the sources of losses in state-of-the-art CdTe photovoltaic devices. Using this strategy and advanced synthesis, losses at the front interface, absorber, and rear interface were worked on in parallel. The final objective was to significantly improve the voltage deficit in CdTe devices to enable improvements in photovoltage and efficiency that can be implemented by industry in the near-term. Over the course of the project, the team developed new characterization techniques, analysis, and modeling which were then applied to state-of-the-art materials generated internally and collaboratively. In particular to enable rapid progress, NREL worked closely with First Solar where NREL grew complete devices as well as ones that interleaved process steps where First Solar had completed different steps such as absorber growth or absorber growth and activation using their baseline methods. Using detailed characterization and analysis including photoemission, photoluminescence, and scanning probe techniques enabled understanding of the loss pathways and area for improvements in our own and First Solar s materials. Ultimately, this contributed to the first series of new world record CdTe efficiencies since 2016, culminating in a 23.1% certified cell that was P-doped along with As-doped cells of similar performance. Internally, NREL improved the statistical variation in baseline As-doped devices and improved average photovoltage by over 100 mV. This was done through an improvement in absorber quality, changed front interface, and improved back contact. In addition to materially improving the fabrication processes at NREL, characterization, analysis, and modeling were developed and disseminated. NREL also played a pivotal role in community building over the course of this project working closely with the Cadmium Telluride Accelerator Consortium. NREL worked in a series of collaborations with academic and industry partners, leveraging knowledge and innovations from this project, as well as helped organize a series of workshops to ensure rapid progress in the field. Working closely with the academic community has led to a dissemination of knowledge; working with First Solar as increased US competitiveness First Solar expanded domestic production to ~10 GW and opened new facilities.

14 SOLAR ENERGY↗

Comprehensive Efficiency Analysis of Seven-Switch Current-Source Inverter Based on Voltage-Boost Function and Genetic Algorithm

This paper investigates the voltage-boost features of the emerging seven-switch current-source inverter (H7-CSI) to improve the efficiency of the CSI-based motor drive system. The switching transient and power loss model of the H7-CSI topology during voltage-boost operation are analyzed in detail. The effects of the boost function on the switching and conduction loss of the H7-CSI topology are investigated. A genetic algorithm has been introduced that makes it possible to optimize the H7-CSI’s modulation index to minimize its power loss. Experimental results for the H7-CSI unit show that this optimization can reduce the power loss by 10.6%.

42 ENGINEERING↗

Modeling Framework to Analyze Performance and Structural Reliability of Solid Oxide Electrolysis Cells

Solid oxide electrolysis cells (SOEC) have been receiving significant attention recently because of their high energy efficiency and fast hydrogen production. In this study a multi-physics model to simulate the SOEC performance and structural reliability of a state-of-the-art planar SOEC design was developed. The electrochemical reactions, fluid dynamics, species transport, electron transfer, and heat transfer were modeled in the commercial computational fluid dynamics (CFD) software STAR-CCM+. The thermomechanical analysis and the associated structural reliability evaluations were conducted using the commercial finite element analysis software ANSYS. The electrochemistry model was validated by using the experimentally obtained current-voltage (I-V) characteristics of the electrode-supported SOECs. The reliability analysis using a risk-of-rupture approach showed low failure probabilities under standard operating conditions considered in this study. For cells operated at voltages well above a thermoneutral voltage, the reliability evaluations indicated a potential risk of cell failure, but the damage was concentrated locally in specific areas of the cell which typically do not lead to total loss of cell function. The presented approach provides insights for evaluating representative cell and stack performances and structural reliability without intensive testing and for developing optimally performing and structurally reliable SOECs for efficient hydrogen generation.

25 ENERGY STORAGE↗

To grind or not to grind? The influence of mechanical and thermal treatments on the $\mathrm{Cu/Zn}$ disorder in $\mathrm{Cu}$ 2 $\mathrm{ZnSn}$($\mathrm{S}$ x $\mathrm{Se}$ 1-x ) 4 monograins

We report that Kesterite-type based thin film solar cell technologies are mainly based on polycrystalline absorber layers. A promising low cost alternative technology uses Cu 2 ZnSn(S x Se 1-x ) 4 (CZTSSe) monograins (single crystals of 20–100 μm size) which are fixed in a polymer matrix to form a flexible solar cell. The Cu/Zn disorder is discussed as a possible reason for band tailing causing voltage losses limiting the efficiency of CZTSSe-based devices. The experimental determination of the order parameter Q which is a quantitative measure of Cu/Zn disorder, requires a differentiation between the isoelectronic cations Cu + and Zn 2+ . An in-depth analysis of neutron diffraction data allows the determination of type and concentration of intrinsic point defects including a distinction between Cu and Zn. Neutron diffraction requires large sample volumes, thus monograins offer the unique possibility to correlate structural disorder in CZTSSe with device performance parameters. In this study we tackle the influence of grinding the monograins on stoichiometry deviations, the Cu/Zn disorder as well as intrinsic point defects and optoelectronic properties of CZTSSe monograins. Moreover, an easy methodology based on Raman scattering spectroscopy is proposed for the assessment of Cu/Zn disorder in the CZTSSe compounds.

14 SOLAR ENERGY↗

Probing Operando Electrochemical Strain Generation in α-NaFeO 2 Composite Cathodes during Cycling of Na-Ion Batteries

The transition metal oxide (TMO) cathodes in Na-ion batteries suffer from low-capacity retention. Chemo-mechanical instabilities lead to the deterioration of the electrochemical performance of TMO cathodes in Li-ion batteries. However, there is not much known about the chemo-mechanical instabilities in the TMO cathodes for Na-ion batteries. Understanding the governing forces behind the interplay between the electrochemical performance and mechanical stability in TMO cathodes is critical for the development of Na-ion batteries. Here, we synchronize the digital image correlation (DIC) technique with electrochemical analysis to capture the real-time deformation behavior of the α-NaFeO 2 cathodes during cycling. When the charge cutoff voltage is 3.6 V, the cathode experiences reversible deformations (except for the first cycle). There is negative strain (shrinkage) generation during Na extraction and positive strain (expansion) generation during the subsequent Na insertion. A detailed analysis of the potential-dependent strain rate evolution points out complicated phase transformations and nonequilibrium conditions in the α-NaFeO 2 cathodes during cycling. When the charge cutoff voltage was increased to 4.2 V, there was a rapid capacity loss and large plastic deformations in the α-NaFeO 2 cathodes. We provide an in-depth discussion about the possible mechanisms behind the chemo-mechanical instabilities in the α-NaFeO 2 . In conclusion, the correlation is critical to develop material-based strategies to mitigate instability mechanisms in TMO cathodes for Na-ion batteries.

Wable, Minal [University of Maryland Baltimore Cou↗

Design considerations of series type hybrid circuit breaker (S‐HCB)

Abstract The series‐type direct current (DC) hybrid circuit breaker (S‐HCB) concept was previously reported to offer better performance than solid‐state circuit breakers (SSCB) and hybrid circuit breakers (HCB). S‐HCB offers low conduction power loss like an HCB and ‐scale interruption time, which is even faster than an SSCB. It uses a pulse transformer to isolate the lower‐voltage high‐inductance power electronic circuit from the high‐voltage, low‐inductance main power loop. This paper provides analysis of the impact of the S‐HCB circuit components on the overall system performance and a scalable S‐HCB design guide for different DC system voltage and current ratings. In addition, system energy flow analysis is performed in the time domain to provide an understanding of how energy is delivered, dissipated, and released throughout the entire fault interruption process. The S‐HCB prototype was experimentally tested at 3 kV/30 A and 6 kV/150A with the results showing the interruption of the low fault current of 30 A and the high fault current of 150 A within 8 and maintaining the fault current at a near zero value for 300 to enable an arcless opening of a series mechanical switch. The key design challenges of S‐HCB at high voltage and high current ratings were discussed and possible solutions to mitigate those challenges were introduced.

Alashi, Mahmoud↗

Dynamic Modeling of Power Conversion Stages for an Exascale Supercomputer

In this paper a power conversion and energy consumption model for an exascale supercomputer is investigated. Power consumption, energy loss and efficiency are derived for the 27.2 MW liquid-cooled, centralized, High Performance Computing (HPC) power system, which is supplied directly from the 480 V three-phase mains. Two energy conversion stages are analyzed, measured and modeled. The model is developed in order to be adapted and implemented in a digital twin platform utilizing a Resource Allocator and Power Simulator (RAPS) module. RAPS enables estimation of potential energy savings in the direct AC power supply architecture via both conventional rectifier load sharing (commonly used in HPC systems), as well as smart rectifier load sharing. Moreover, besides the direct AC supply architecture analysis, the full direct DC supply architecture with with 1 kV DC bus were also studied. Comparison of 10 hour time frame operation of the system, with direct 480 V AC voltage supply with conventional and smart load sharing and medium dc voltage supply were done. For the direct AC supply architecture, with conventional and smart load sharing the predicted power loss was approximately 840 kW and 820 kW, respectively and the predicted total system efficiency was 92.87% and 93.05%, respectively. For the direct DC supply architecture with the 1000 V DC supply bus power loss was approximately 340 kW and the predicted total system efficiency was 97.02%.

Wojda, Rafal↗