Search NASASearch

SEARCH · Search NASA

Results for “x-ray photoelectron spectroscopy (XPS)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

491 records · Page 4

Adapting High-Resolution X-Ray Microcalorimeter Spectrometers to Transform MFE Plasma Diagnostics

The aim of this project was to begin the transformation of magnetic fusion energy (MFE) X-ray diagnostics by applying detector technology developed over the past several decades by the astrophysics community. We installed and operated an X-ray microcalorimeter detector system under fusion-relevant plasma conditions at the Madison Symmetric Torus (MST). X-ray microcalorimeter spectrometers combine the best characteristics of instrumentation currently available on fusion devices: the high spectral resolution of crystal spectrometers (2 eV) and broadband coverage provided by pulse-height analysis systems. These spectrometers have small port-access requirements, a key advantage for future MFE experiments. This new plasma diagnostic technique will satisfy the need for multispecies impurity ion data by providing absolute measurements of impurity core accumulation, and it will provide the core impurity ion temperature. This project was a joint effort between Lawrence Livermore National Laboratory (LLNL) and researchers at the Wisconsin Plasma Physics Laboratory (WiPPl) at the University of Wisconsin–Madison (UW–Madison). Megan E. Eckart is the principal investigator at LLNL, which is funded separately from UW–Madison. This final report fulfills the reporting obligation of the UW–Madison effort.

Den Hartog, Daniel J. [Department of Physics, Univ

Toward Large Field-of-view X-ray Spectrometers with Magnetic Microcalorimeters

A future X-ray telescope mission like Lynx, a X-ray flagship mission concept, requires a large field of view, high energy resolution, and high spatial resolution. The Magnetic Microcalorimeter (MMC) detectors we are developing for such a mission feature a 5-arcminute field of view, approximately 100,000 pixels, each spanning 0.5–1 arcsecond. These detectors require the readout of 8,000 sensors. Three different array types have been designed to meet scientific goals, two of which utilize thermal multiplexing to reduce the number of readout channels in a scheme called “Hydra.” We are currently fabricating detectors on a recently completed buried wiring wafer with connections to every sensor. The sensors are read out using a microwave multiplexer (μMUX) with flux ramp modulation. A single μMUX can read out approximately 1,000 sensors with only two feed lines. We will report on the test of the first two-dimensional μMUX chip, consisting of 78 resonators. μMUX chips that pass screening will be directly bonded to MMC array chips using indium bump bonding. In parallel, we have tested a kinetic inductance traveling wave parametric amplifier (KI-TWPA) to amplify signals at low temperatures. The KI-TWPA exhibits extremely low internal noise, approaching the standard quantum limit. Since the energy resolution of an MMC is primarily limited by the readout system, the KI-TWPA is an ideal amplifier for MMCs with μMUX readout. We recently measured the readout noise of a μMUX with a KI-TWPA, demonstrating its capability for reading out MMC arrays. We present the design and fabrication of the latest MMC detectors, along with its readout performance.

Magntic Microcalorimeters

SuperHERO X-ray Telescope Balloon Mission

The SuperHERO hard X-ray telescope will observe extended sources at unprecedented imaging resolution, revealing the origins of non-thermal emission in extreme astrophysical environments. Employing NASA Marshall Space Flight Center’s replicated NiCo full-shell X-ray mirror technology to achieve better than 10-arcsecond half-power diameter (HPD) angular resolution on a balloon platform, SuperHERO consists of seven identical, co-aligned telescopes with a combined effective area of 45 cm² at 30 keV. SuperHERO was selected in the APRA 2023 call as a five-year mission, with an inaugural two-day flight scheduled from Fort Sumner, New Mexico, in the fall of 2028. For its initial target, SuperHERO will observe the Crab pulsar wind nebula, localizing hard X-ray emission. Mission development is currently underway, with updates and status to be provided in this presentation.

Nick Thomas

Boron-Based Neutron Scintillator Screen Characterization with X-Rays and Neutrons

Recent work on boron-based neutron scintillator screens suggests these screens can offer superior performance when compared to commonly used screens. Borated neutron scintillator screens perform well in terms of light output (5-6 times greater than a standard Gadox screen) and detection effi-ciency (larger than standard LiF+ZnS screens). However, previously manu-factured boron-based screens have exhibited non-uniform surface coating and a poor mixture between phosphor and converter particles. The objective of this work was to evaluate newly fabricated scintillator screens to deter-mine if enhanced fabrication methods produced a more homogeneous distribution between neutron converter and scintillation phosphor particles. Uniformity of scintillator material deposition was also inspected. This new iteration of screens appeared more uniform than previous generations with the new coating method improving surface chemistry and scintillator material homogeneity. Additionally, a new methodology for screen characterization, involving the correlation of a neutron image taken with a borated scintillator screen to X-ray computed tomography of that same screen, was demonstrated to elucidate a relationship between scintillator screen thickness and relative light output of the screen under neutron exposure. This method suggested that the ideal thickness of scintillator material was ~150 µm to maximize light output of the screen.

36 - MATERIALS SCIENCE

The HEROIX Broadband X-Ray Space Telescope Mission Concept

The High EneRgy Observatory for Imaging X-rays (HEROIX) Medium-Class Mission concept envisions a next-generation broadband X-ray observatory designed to meet the astrophysics community’s need for high-angular-resolution studies of the Cosmic X-ray Background. Building on the science legacy of NASA’s NuSTAR mission and more than 30 years of advances in replicated NiCo shell technology at NASA Marshall, HEROIX proposes a space observatory comprising four co-aligned telescopes achieving 5 arcsecond half-power diameter (HPD) angular resolution. This capability, approached by the resolution demonstrated in the FOXSI-4 sounding rocket mission and under development through the SuperHERO balloon mission, will be extended to energies up to 80 keV through multilayer coatings. Marshall’s inhouse precision optics manufacturing enables an integrated effective area of 380 cm² at 30 keV, which, combined with high-resolution optics, opens new windows into extreme astrophysical non-thermal processes.

Nick Thomas

Polarized Resonant Soft X-ray Scattering (P-RSoXS) as a New Technique for Characterizing Amorphous Astromaterials

In the coming years, samples will be returned from several asteroids, the lunar surface, and the first material returned directly from the Martian surface. Previous in-situ and remote studies indicate these samples will contain abundant amorphous or weakly crystalline materials. However, detailed characterization and quantification of these amorphous materials remains challenging. Conventional techniques, including electron microscopy and X-ray diffraction, provide important information on material structure, but are generally limited to crystalline materials. Polarized resonant soft X-ray scattering (P-RSoXS) is a synchrotron-based X-ray scattering technique that has been used to characterize and quantify weakly crystalline systems, including soft materials. This research aims to translate this technique to geologic and extraterrestrial materials, building off the knowledge of using P-RSoXS to interrogate soft materials. P-RSoXS is well-suited to interrogate geologic materials, which are often multiphase, heterogeneous systems with crystalline and amorphous components, and domain sizes on the order of tens of nanometers. It is anticipated that future work will help reveal new chemical and structural information in geologic materials. Maturation of this preliminary work to develop P-RSoXS to characterize astromaterial-relevant samples will provide new understanding of the secondary processes responsible for the development of amorphous astromaterials and further elucidate our knowledge of the geologic history and past alteration processes.

Joshua H Litofsky

LBFD X-59 Propulsion Overview

The LBFD X-59 Propulsion Overview is prepared in support of a panel session at the 2026 AIAA Aviation Conference. The overview covers highlights of the X-59 propulsion system, a short history of propulsion testing at NASA GRC, A summary of X-59 ground testing, a summary of X-59 flight testing, and finally some lessons learned.

Aerodynamic

Lunar Elemental Analysis Obtained From the Apollo Gamma-Ray and X-Ray Remote Sensing Experiment

Gamma-ray and X-ray spectrometers carried in the Service Modules of the Apollo 15 and Apollo 16 spacecraft were employed for compositional mapping of the lunar surface. The measurements involved the observation of the intensity and characteristic energy distribution of gamma rays and X-rays emitted from the lunar surface. A large-scale compositional map of over 10 percent of the lunar surface was obtained from an analysis of the observed spectra. The Apollo 15 flight was at a lunar orbital inclination of 29 degrees as compared with a 9-degree inclination of the Apollo 16 flight; thus, the projected ground track of the Apollo 15 flight covered a larger projected surface area than that of the Apollo 16 flight. The objective of the X-ray experiment was to measure the K spectral lines from Mg, Al, and Si. Spectra were obtained and the data were reduced to Al/Si and Mg/Si intensity ratios and ultimately to chemical ratios. Analyses of the results have indicated (1) that the Al/Si ratios are highest in the lunar highlands and considerably lower in the maria, and (2) that the Mg/Si concentrations generally show the opposite relationship. There is a tendency for the Al/Si values to increase from the western mare areas to the eastern limb highlands. There are distinct chemical contrasts between such features: as the small mare basins and the highland rims. The objective of the gamma-ray experiment was to measure the natural and cosmic-ray-induced activity emission spectrum. At this time, the elemental abundances for Th, U, K, Fe, Ti, Si, and O have been determined over a number of major lunar regions. Regions of relatively high natural radioactivity were found in the Mare Imbrium and Oceanus Procellarum regions. High spots of natural radioactivity were also found south of Fra Mauro; somewhat southwest of Archimedes, and south of Aristarchus. An enhanced region of natural radioactivity was found around Van de Graaff on the far side of tile Moon. In regions other than Mare Imbrium and Oceanus Procellarum, an anticorrelation between natural radioactivity and lunar elevation, as determined from the Apollo laser, altimeter, has been found. From the combined results of the gamma-ray and X-ray spectrometer experiments almost complete information concerning the major element composition of over 10 percent of the lunar surface has been obtained. Distributions have also been mapped for K, Th, and Ti. Interesting correlations between lunar topography and magnetic and gravitational properties have been found.

J I Trombka

Taking three-dimensional x-ray diffraction (3DXRD) from the synchrotron to the laboratory scale

Three-dimensional x-ray diffraction (3DXRD), a rotating x-ray diffraction technique, is a powerful tool for studying the micromechanical behavior of polycrystalline materials, capable of measuring the volume, position, orientation, and strain of thousands of grains simultaneously. However, its application has been historically limited to synchrotron facilities. Here, we present the first demonstration of laboratory-scale 3DXRD (Lab-3DXRD) using a liquid-metal-jet source. Lab-3DXRD achieves accuracy comparable to synchrotron-based 3DXRD, as validated against laboratory diffraction contrast tomography (LabDCT) and synchrotron-3DXRD. Over 96% of the grains detected with Lab-3DXRD are cross-validated, particularly for coarse grains (> ~60 μm), while the results suggest that finer grains should be accessible by taking advantage of high-efficiency detectors. We further demonstrate that its sensitivity to finer grains is enhanced by incorporating pre-characterization into the analysis. This study establishes Lab-3DXRD as a practical alternative to synchrotron techniques, making 3DXRD accessible to a wider range of academic and industrial researchers.

characterization and analytical techniques

Direct comparison of gamma, electron beam and X-ray radiation effects on the polymers of a pulsed lavage device

Gamma radiation used for sterilization of medical devices is challenged by cobalt-60 supply and commercial capacity. To maintain a robust radiation sterilization marketplace for the rapidly growing single-use medical device industry, investigation of potential alternatives to gamma technology, such as electron beam (e-beam) and X-ray technology, is critical. In this work, we directly compare the effects of radiation source and absorbed dose level on the polymeric materials and function of a commercial pulsed lavage device used for wound care. Product functionality, polymer mechanical, and polymer optical properties were evaluated using standard methods and input from the device manufacturer. Test results show that functionality of the product was not inhibited by radiation although the battery in the device exposed to X-ray exhibited greater voltage loss compared to batteries in products exposed to gamma or e-beam. Statistically significant differences between gamma and e-beam exposure and between gamma and X-ray exposure were also observed for product appearance in terms of yellowness index of several of the polymers considered. Overall, the results of this study support the viability of e-beam and X-ray radiation technologies as alternatives to cobalt-60 gamma technology for sterilization of the single-use pulsed lavage medical device investigated.

Electron beam

Dynamic sparse x-ray nanotomography reveals ionomer hydration mechanism in polymer electrolyte fuel-cell catalyst

Tomographic imaging of time-evolving samples is a challenging yet important task for various research fields. At the nanoscale, current approaches face limitations of measurement speed or resolution due to lengthy acquisitions. We developed a dynamic nanotomography technique based on sparse dynamic imaging and 4D tomography modeling. We demonstrated the technique, using ptychographic x-ray computed tomography as its imaging modality, on resolving the in situ hydration process of polymer electrolyte fuel cell (PEFC) catalyst. The technique provides a 40-time increase in temporal resolution compared to conventional approaches, yielding 28 nm half-period spatial and 12 min temporal resolution. The results allow a quantitative characterization of the water intake process inside PEFC catalysts with nanoscale resolution, which is crucial for understanding their electrochemical mechanisms and optimizing their performance. Our technique enables high-speed operando nanotomography studies and paves the way for wider application of dynamic tomography at the nanoscale.

Science & Technology - Other Topics

High-Throughput Uniformity and Defect Monitoring in Low-Temperature Electrolysis Porous Transport Layers Using X-Ray Radiography

Effective quality control (QC) for manufacturing proton exchange membrane water electrolysis (PEMWE) components is critical to enabling widespread adoption of the technology for hydrogen generation. This study investigates X-ray radiography as a novel, high-throughput, potentially in-line QC technique for detecting defects and assessing material property distributions in titanium-based porous transport layers (PTLs) which constitute a crucial component of low temperature PEMWE stacks. We obtain radiographs of a set of fifteen PTLs and model their absorbance of the broadband radiation as a second-order polynomial to account for the non-monoenergetic radiation source used in this study. The resulting model serves as a basis for predicting the areal density and porosity distributions of the PTLs. We find radiography successful in detecting multiple instances of defects, including holes/depressions, cracks, and excess material on the surface or in the pores of the material, demonstrating its potential as a robust in-line QC tool for PTL manufacturing.

08 HYDROGEN

The Alpha-Proton-X-Ray Spectrometer Deployment Mechanism: an Anthropomorphic Approach to Sensor Placement on Martian Rocks and Soil

On July 4,1997, the Mars Pathfinder spacecraft lands on Mars and starts conducting technological and scientific experiments. One experiment, the Alpha-Proton-X-ray Spectrometer, uses a sensor head placed against rocks and soil to determine their composition. To guarantee proper placement, a deployment mechanism mounted on the Mars Rover aligns the sensor head to within 20 deg of the rock and soil surfaces. In carrying out its task, the mechanism mimics the action of a human hand and arm. Consisting of a flexible wrist, a parallel link arm, a brush dc motor actuator, and a revolutionary non-pyrotechnic fail-safe release device, the mechanism correctly positions the sensor head on rocks as high as 0.29 m and on targets whose surfaces are tilted as much as 45 deg from the nominal orientation of the sensor head face. The mechanism weighs less than 0.5 kg, can withstand 100 g's, and requires less than 2.8 N x m of actuation torque. The fail-safe coupler utilizes Cerrobend, a metal alloy that melts at 60 C, to fuse the actuator and the rest of the mechanism together. A film heater wrapped around the coupler melts the metal, and Negator springs drive the mechanism into its stowed position. The fail-safe actuates using 6.75 Watts for 5 minutes in the event of an actuator failure.

Richard S Blomquist

In situ electric field X-ray total scattering reveals composition-dependent electromechanical strain mechanisms in (1 − x )BiFe 2/8 Ti 3/8 Mg 3/8 O 3 – x PbTiO 3 ceramics

Ferroelectric materials find many applications in energy and aerospace industries. A major challenge for ferroelectric materials is maintaining their properties at elevated temperatures. The (1 − x )BiFe 2/8 Ti 3/8 Mg 3/8 O 3 – x PbTiO 3 (BFTM–xPT) ferroelectric solid solution is a promising candidate for high-temperature applications as it has a high piezoelectric response while also maintaining its ferroelectric phase until a high Curie temperature (T C ) of 650 °C. In this work, we investigate the piezoelectric mechanism in BFTM–xPT, a novel high-T C ferroelectric ceramic. To elucidate the origin of its enhanced piezoelectric performance, relative to other piezoceramics of similar T C , in situ electric field X-ray total scattering experiments were performed. Total scattering combines Bragg scattering (diffraction) and diffuse scattering (pair distribution function), providing insight on various length scales. With information spanning different length scales, extrinsic contributions (i.e., domain wall motion and interphase boundary motion) can be separated from intrinsic contributions (i.e., piezoelectric lattice strain). We show that, for compositions within the morphotropic phase boundary (MPB, x = 0.325), the piezoelectric response is dominated by intrinsic piezoelectric lattice strain, whereas outside the MPB (x = 0.375) the major component of the piezoelectric response is from extrinsic mechanisms including an electric-field-induced phase transition and tetragonal domain wall motion. This article reveals that the origin of piezoelectric response in BFTM–xPT is composition-dependent and shows that high-performance materials may also be located outside the MPB. These findings can help guide material design to optimize properties for specific applications.

Richtik, Brooke N. [University of Calgary, AB (Can

In-Situ Visualization of a Growing Brittle Crack in Aluminum Oxynitride Using Synchrotron X-Rays and the Double-Cleavage Drilled Compression Geometry

Brittle fracture is difficult to study in situ due to the speed of a growing crack and the often-catastrophic nature of failure in brittle materials. As a result, the influence of microstructural considerations, such as orientation, grain boundary locations, and strain field, on the crack path remains poorly understood. Presented in this study is a method addressing this knowledge gap, which utilizes the double-cleavage drilled compression geometry to achieve quasi-stable fracture in aluminum oxynitride (AlON). Synchrotron X-ray micro-computed tomography is used to characterize the crack shape and length, while high-energy diffraction microscopy provides information on the strains, orientations, and shapes of grains in the microstructure surrounding the crack tip. During testing, the crack grew in discrete and irregular jumps while the fracture toughness falls within reported ranges. The crack in AlON is found to have no greater tendency to crack intergranularly as compared to transgranularly, and grains which are cracked transgranularly do not display a trend in orientation or stress when compared to those around which the crack followed a grain boundary. The high resolution of the crack path and microstructural data provides a path forward for modeling and understanding 3D brittle fracture.

Gorske, Sara F.

Conformational Isomerization of Imide Anions Governs Solvation and Transport in Water-in-Salt Electrolytes

The behavior of highly concentrated electrolytes departs radically from the dilute-solution theory, yet the molecular origin of this transformation remains unresolved. Here, we identify the conformational isomerization of molecular ions as a decisive, previously unrecognized control parameter governing structure and transport in crowded aqueous electrolytes. Across a series of fluorosulfonimide anions, we show that increasing concentration drives a collective shift from extended transoid to compact cisoid conformers, revealed by small-angle X-ray scattering, vibrational spectroscopy, pulsed-field gradient NMR, and molecular dynamics simulations. This conformational transition triggers a collapse of the hydrogen-bonded water network and the emergence of densely packed ionic domains with confined water, producing a qualitative change in Li+ transport from solvent-mediated diffusion to network-confined hopping. Anion size and asymmetry systematically tune the onset of this transition, demonstrating that molecular geometry dictates mesoscale organization and dynamics in the ion-rich regime. Our results establish ion conformation, not merely composition or coordination, as a fundamental thermodynamic variable in concentrated solutions, providing a chemical framework that unifies solvation structure and transport in water-in-salt electrolytes and suggesting new principles for designing dense ionic media.

Nguyen, Huong TD

Synthetic Tuning of Exciton–Phonon Coupling in Janus WS 2(1-x) Se 2x Monolayers Revealed by Resonant Raman Excitation Spectroscopy for Optoelectronic Applications

Janus monolayers, such as WSSe, have broken out-of-plane symmetry and an intrinsic dipole moment, impacting exciton transport, lifetime, and phonon interactions while imbuing piezoelectric, photocatalytic, and Rashba spin-splitting properties to transition metal dichalcogenides (TMDs). The new properties of this atomically thin material can be used for optoelectronic device applications. As TMDs are converted into Janus monolayers, e.g., top selenization of WS2 to WSSe, the bandgap and structure smoothly evolve, impacting not only the formation of excitons but also their complex interactions with different phonon modes. Resonant Raman excitation profiles (REPs) are uniquely well-suited to reveal both excitonic transitions and exciton–phonon coupling. Here, the resonant REPs of $A^{'}_{1}$ WS 2 and A 1 WSSe modes are measured to understand the strength of their coupling with the A, B, and C excitonic bands of a WS2 monolayer throughout its stepwise transformation into Janus WSSe by pulsed laser deposition (PLD) of energetic selenium species. In situ Raman spectroscopy during deposition is used to controllably prepare stable intermediate Janus structures, WS 2(1-x) Se 2x (0 ≤ x ≤ 0.5), for ex situ measurement of their resonant REPs. As x increases, REPs reveal not only pronounced excitonic bands that gradually shift toward lower photon energies but also strong, mode-selective exciton–phonon coupling. First-principles resonant Raman simulations independently predict this spectral behavior and are shown capable of matching the spectrally broadened, experimentally observed REP profiles in this model system, indicating their strong predictive capability for future experiments. The combination of controlled synthesis, REP characterization, and predictive theory employed here demonstrates a powerful pathway to understand and ultimately tune exciton–phonon interactions for future quantum optical devices.

Janus monolayers