SEARCH · Search NASA
Results for “Absolute”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
On Absolute Phase Determination Techniques on SAR Interferometry
Cross-track interferometric SAR can provide 3-dimensional radar images. The technique relies on
Updates to the Absolute Radiometric Accuracy of the AIRS on Aqua
The Atmospheric Infrared Sounder (AIRS) on the EOS Aqua Spacecraft was launched on May 4, 2002. The AIRS was designed to measure small changes in the global hydro-thermodynamic cycle and has demonstrated exceptional radiometric and spectral stability and accuracy in-orbit. This accuracy is achieved by transferring the calibration from a Large Area Blackbody (LABB) to the On-Board Calibrator (OBC) blackbody during preflight testing. The LABB theoretical emissivity is in excess of 0.9999 and temperature uncertainty is less than 50 mK. The LABB emitted radiance is NIST traceable through thermistors located on the internal surfaces. The AIRS also provides a full aperture space view every scan for offset calibration. AIRS nonlinearity and polarization calibration coefficients were based on pre-flight testing and have been amongst the highest uncertainty sources in the calibration. A recent method using on-board space view data has reduced the uncertainty of the polarization coefficients and use of separate A side and B side data from preflight testing has reduced the uncertainty of the nonlinearity estimates. An update to the system radiometric uncertainty is made based on the new data and is presented in this paper.
Absolute and Relative Trajectory Measurement System (ARTMS)
Explore the source record for details and available documents.
Angles-Only Absolute and Relative Trajectory Measurement System (ARTMS)
Explore the source record for details and available documents.
Absolute Characterization of Gravity Sag for Light-Weighted Optics
Explore the source record for details and available documents.
NDE of Climate Absolute Radiance and Refractivity Observatory Wire Harness Failure
Explore the source record for details and available documents.
Bayesian Absolute Detection Efficiency of the GLMs
Explore the source record for details and available documents.
Comparison of Detector Based and Source Based Absolute Radiance Standards
A detailed comparison of two separate radiometric calibration standards was conducted with analysis of error sources for each. One is a detector based standard, with radiance traceable to fundamental units using the electrical substitution method. The other is based on a calibrated field emission lamp (FEL) generating blackbody radiation. This study was motivated by the discontinuance of the FEL lamps by the manufacturer and a desire to calibrate sensors using non-blackbody spectral profiles. Three spectrometers were calibrated simultaneously by both methods to separate spectrometer artifacts from differences in the radiometric standards and error in the irradiance to radiance conversion procedure needed for the FEL. Conducting this study now is important to provide continuity between the extensive prior FEL based calibration database with a replacement method while calibrated FEL lamps are still available. This also begins a longer term repeatability study of the spectrometers used in this work for evaluation as calibrated transfer standards, usable with both monochromatic and broad spectrum radiance sources. Eliminating the tie to the FEL blackbody spectrum with a detector based standard allows for flexibility in the illumination source. In particular, for Earth science sensors intended for use with sunlit scenes, augmenting traditional tungsten halogen lighting with blue and ultraviolet light emitting diodes allows for a better match to the solar spectrum during laboratory testing.
Comparison of Detector Based and Source Based Absolute Radiance Standards
A detailed comparison of two separate radiometric calibration standards was conducted with analysis of error sources for each. One is a detector based standard, with radiance traceable to fundamental units using the electrical substitution method. The other is based on a calibrated field emission lamp (FEL) generating blackbody radiation. This study was motivated by the discontinuance of the FEL lamps by the manufacturer and a desire to calibrate sensors using non-blackbody spectral profiles. Three spectrometers were calibrated simultaneously by both methods to separate spectrometer artifacts from differences in the radiometric standards and error in the irradiance to radiance conversion procedure needed for the FEL. Conducting this study now is important to provide continuity between the extensive prior FEL based calibration database with a replacement method while calibrated FEL lamps are still available. This also begins a longer term repeatability study of the spectrometers used in this work for evaluation as calibrated transfer standards, usable with both monochromatic and broad spectrum radiance sources. Eliminating the tie to the FEL blackbody spectrum with a detector based standard allows for flexibility in the illumination source. In particular, for Earth science sensors intended for use with sunlit scenes, augmenting traditional tungsten halogen lighting with blue and ultraviolet light emitting diodes allows for a better match to the solar spectrum during laboratory testing.
The Ground-Based Absolute Radiometric Calibration of the Landsat 9 Operational Land Imager
Explore the source record for details and available documents.
Deflected beam method for absolute current density determination
Explore the source record for details and available documents.
Characterization of the Climate Absolute Radiance and Refractivity Observatory (CLARREO) ability to serve as an infrared satellite intercalibration reference
Explore the source record for details and available documents.
Position and Proper Motion of Sagittarius A* in the ICRF3 Frame from VLBI Absolute Astrometry
Explore the source record for details and available documents.
Nonlinear equilibration of localized instabilities on a baroclinic jet
Dynamical mechanisms underlying the equilibration of absolute instability are examined in a nonlinear, quasigeostrophic, two-layer model. The key to understanding the nonlinear equilibration is in recognizing that linear absolute instabilities can be stabilized both by a reduction of the vertical shear and by enhancement of the mean barotropic velocity. In a localized domain, the equilibration process proceeds with the creation of locally convectively unstable regions downstream, which encroach onto the locally absolutely unstable region until the local instability is suppressed. That local instabilities exist only if absolutely unstable regions span a minimum size is verified by eigenvalue calculations of three-dimensional flows. Numerical examples suggest that this critical size is at least 9000 km for a wide range of parameter values chosen to investigate the midlatitude storm tracks. Fluctuations arising from local absolute instability obtain maximum amplitude in the downstream convectively unstable regions rather than in the absolutely unstable regions themselves. Together, these results suggest that if an equilibrated absolute instability were to occur in midlatitudes, a zonal band of surface easterlies exceeding 900 km would be required and the associated enhanced variances would not be found coincident with the regions of absolute instability.
Efficient Merge and Insert Operations for Binary Heaps and Trees
Binary heaps and binary search trees merge efficiently. We introduce a new amortized analysis that allows us to prove the cost of merging either binary heaps or balanced binary trees is O(l), in the amortized sense. The standard set of other operations (create, insert, delete, extract minimum, in the case of binary heaps, and balanced binary trees, as well as a search operation for balanced binary trees) remain with a cost of O(log n). For binary heaps implemented as arrays, we show a new merge algorithm that has a single operation cost for merging two heaps, a and b, of O(absolute value of a + min(log absolute value of b log log absolute value of b. log absolute value of a log absolute value of b). This is an improvement over O(absolute value of a + log absolute value of a log absolute value of b). The cost of the new merge is so low that it can be used in a new structure which we call shadow heaps. to implement the insert operation to a tunable efficiency. Shadow heaps support the insert operation for simple priority queues in an amortized time of O(f(n)) and other operations in time O((log n log log n)/f (n)), where 1 less than or equal to f (n) less than or equal to log log n. More generally, the results here show that any data structure with operations that change its size by at most one, with the exception of a merge (aka meld) operation, can efficiently amortize the cost of the merge under conditions that are true for most implementations of binary heaps and search trees.