Search NASA⌕ Search

SEARCH · Search NASA

Results for “Control algorithms”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Smart Inverter Twin Model for Anomaly Detection

Smart inverters connected to a communication network are vulnerable to various anomalies in the form of cyberattacks. In this paper, a self-security approach is implemented using the digital twin concept for smart inverters. The digital twin is formed using the inverter’s dynamic model. Then, the incoming setpoints are autonomously examined using the digital twin, and only the safe setpoints are engaged to the inverter’s local controller. This paper demonstrates the details of the self-security algorithm and how the inverter’s digital twin is formed. In particular, the stable and unstable operation region is experimentally verified by changing the power setpoints engaged to the local controller, using a laboratory setup including a three-phase 1.5-kVA SiC-MOSFET inverter and a 12-kW NHR 9410 regenerative power grid emulator. The results demonstrate that the digital twin model can potentially protect inverters from abnormal operation by examining the incoming commands (new setpoints) using the inverter’s digital twin before engaging the setpoints to the local controller.

Hossen, Tareq↗

A Robust Method to Secure Multi-Inverter Grid Tied PV and Battery Energy Storage Systems Against Cyber Intrusions

This paper details a robust method to secure a multi-inverter grid tied system that interfaces photovoltaic (PV) and battery energy storage against potential cyber-attacks. The method can be applied to any third-party inverter systems without a need to modify their internal controls. A small random private excitation signal termed "watermark" is injected into the DC input voltage terminals (via a series transformer) connected to the PV/battery inverter system. An external robust cyber intrusion detector (CID) hardware consisting of a digital signal processor (DSP) generates the "watermark" and also receives the sensor signals that control the setpoints of the PV/battery grid tied system. The CID algorithm is shown to detect all possible cyber intrusions (such as false data injection(FDI)) on external sensor signals such as P and Q measured by a smart meter that control the overall system operation. The proposed CID computes online system ID and two variance tests in real time on each sensor signal and is able pinpoint intrusion location in a multi-inverter system. Results on a hardware in the loop (HIL) of a two-inverter grid connected system demonstrate effectiveness of the proposed CID system for FDI and unobservable FDI. Test results on a laboratory prototype will be discussed in the conference presentation.

Ibrahim, Hasan↗

Grid Topology Discovery Algorithm Evaluation of Suitability for Utility Deployment (CRADA 606 Final Report)

This work presents the results of a field-informed demonstration aimed at evaluating the practical suitability of a topology discovery algorithm for utility environments. We demonstrated an algorithm that uses a graph-theory-informed state estimation approach for model selection. In collaboration with Survalent and Peninsula Light Co., the algorithm was applied to real feeder models and field measurements from supervisory control and data acquisition (SCADA) and advanced metering infrastructure (AMI) systems to identify the operational topology of a power distribution system. The demonstration assessed the algorithm’s performance under realistic data conditions, including sparse and noisy measurements, and examined its ability to identify the most likely network configurations. The results confirmed that the approach can effectively narrow down feasible topologies, providing operators with improved situational awareness of network status. Key lessons learned emphasize the need for systematic data validation and strategic sensor placement to enhance observability. These insights inform future deployment strategies and guide refinements for broader adoption in utility operations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

TETRIS-ADAPT-VQE: An adaptive algorithm that yields shallower, denser circuit Ansätze

Adaptive quantum variational algorithms are particularly promising for simulating strongly correlated systems on near-term quantum hardware, but they are not yet viable due, in large part, to the severe coherence time limitations on current devices. In this paper, we introduce an algorithm called TETRIS-ADAPT-VQE (tiling efficient trial circuits with rotations implemented simultaneously adaptive derivative-assembled problem-tailored variational quantum eigensolver), which iteratively builds up variational a few operators at a time in a way dictated by the problem being simulated. This algorithm is a modified version of the ADAPT-VQE algorithm, in which the one-operator-at-a-time rule is lifted to allow for the addition of multiple operators with disjoint supports in each iteration. TETRIS-ADAPT-VQE results in denser but significantly shallower circuits, without increasing the number of controlled- gates or variational parameters. Its advantage over the original algorithm in terms of circuit depths increases with the system size. Moreover, the expensive step of measuring the energy gradient with respect to each candidate unitary at each iteration is performed only a fraction of the time compared with ADAPT-VQE. These improvements bring us closer to the goal of demonstrating a practical quantum advantage on quantum hardware. Published by the American Physical Society 2024

Anastasiou, Panagiotis G. (ORCID:0000000256601791)↗

Hierarchical Model-Free Transactive Control of Building Loads to Support Grid Services

Residential buildings consume 4.4 quads of electricity annually, approximately 37% of the total electricity consumption in the United States. This represents a vast resource that can be used for demand management and other ancillary services. This project aims to develop a robust, scalable hierarchical transactional control mechanism incorporating elements of model-free control (MFC) and game theory to harness buildings to provide ancillary services to the grid. This approach is being taken to address the challenges of incorporating traditional transactional control schemes into existing buildings. The challenges include small individual building sizes requiring aggregation of many buildings, unpredictable energy usage that makes model identification difficult, and satisfying the sensitive occupant comfort constraints. In the proposed approach, by separating the control mechanism into two layers above and below the load aggregator, MFC can be used below the aggregator to modulate flexible building loads in response to pricing signals with guaranteed performance. This allows the burden of identifying an accurate model of the system to be shifted to the above-aggregator layer, where fluctuations in individual building usage have less impact on predicted building system behavior. Game theory concepts can then be used to determine pricing curves and control signals among regional aggregators. Managing this control in a game-theoretic approach will allow us to build in financial incentives that increase customer engagement. Additionally, the usage of MFC necessitates less burdensome computational and communication requirements, thus, it is easily deployable on small, embedded devices. In a broader sense, developing a strategy capable of effectively incorporating residential and small commercial buildings will allow greater throughput of existing and emerging grid services in addition to future transactive energy grid management methods. Using MFC within a hierarchical control architecture will allow the shifting of existing forecasting challenges to an aggregate level, where dynamics are slower and more predictable. This will enable a smooth interface between the grid services requests of utilities and the reliable control required by participating buildings. MFC, which supports distributed control architecture, permits a scalable solution that can be deployed to neighborhood-size systems as well as individual buildings. This project focuses on three objectives: (1) developing the mathematical framework, algorithm toolkit, and software toolset of the two-layer transactive control testbed; (2) developing a scalable solution for application over many residential and small-size commercial buildings with sparse distributed communication; and (3) field testing and implementation on hardware of the control strategies developed in the previous two objectives. The research and development activities are focused and designed to be impactful within the relevant 2025 targets timeframe. An open-source control framework for exploiting variability and dispatchability of building loads will be delivered as the outcome of the project. This capability enables greater participation of loads in electricity markets and ancillary services that are both useful for the utility and financially beneficial for building owners.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Advanced Quantum Poisson Solver in the NISQ era

The Poisson equation has many applications across the broad areas of science and engineering. Most quantum algorithms for the Poisson solver presented so far, either suffer from lack of accuracy and/or are limited to very small sizes of the problem, and thus have no practical usage. Here we present an advanced quantum algorithm for solving the Poisson equation with high accuracy and dynamically tunable problem size. After converting the Poisson equation to the linear systems through the finite difference method, we adopt the Harrow-Hassidim-Lloyd (HHL) algorithm as the basic framework. Particularly, in this work we present an advanced circuit that ensures the accuracy of the solution by implementing non-truncated eigenvalues through eigenvalue amplification as well as by increasing the accuracy of the controlled rotation angular coefficients, which are the critical factors in the HHL algorithm. We show that our algorithm not only increases the accuracy of the solutions, but also composes more practical and scalable circuits by dynamically controlling problem size in the NISQ devices. We present both simulated and experimental results, and discuss the sources of errors. Finally, we conclude that overall results on the quantum hardware are dominated by the error in the CNOT gates.

Robson, Walter↗

Evaluation of Optimal Net Load Management in Microgrids Using Hardware-in-the-Loop Simulation

This presentation discusses the performance evaluation of a net load management (NLM) engine that balances load and generation in an isolated community to power a critical facility after a grid interruption event (e.g., the loss of a large generation unit). This NLM engine is particularly important for microgrid systems because it provides a high-speed, cost-optimal control solution to coordinate grid-forming inverters and to dispatch grid-following inverters and deferrable loads in microgrid systems to enhance grid resilience and reliability. The NLM algorithm cost-optimally dispatches the grid-following inverters and deferrable loads based on the demanded power and load priorities, and the grid-forming inverters use droop control to form system voltages and share active and reactive power. A controller-hardware-in-the-loop platform is developed to evaluate the control performance of the NLM algorithm with two sequential contingency events of lost generation units. The experimental results indicate that the NLM engine can maintain system stability, achieve the targeted system voltage and frequency, and balance load and generation to serve the critical facility with improved system resilience and reliability.

droop control↗

Motion Control of Hydraulic Actuators In the Presence of Discrete Pressure Rail Switching

Conventional off-highway mobile machines are hydraulically actuated and have poor energy efficiencies. The goal to increase system efficiency and to reap the benefits of electrification have led to the creation of a novel Hybrid Hydraulic-Electric Architecture (HHEA) which could significantly increase efficiency, decrease the sizes and cost of electrical components, and maintain control performance. The key concept is to utilize a set of common pressure rails to provide the majority of power via the power dense hydraulics and to modulate that power by small electric components, which are less power dense, for precise control. The paper presents the motion control strategy for this architecture. The architecture presents a distinct challenge in that as the energy minimization algorithm selects different pressure rails, the system could experience large discrete jumps in pressures that impact control performance, especially when the electric components are torque limited. To meet this challenge, a passivity based back-stepping controller is used as the nominal controller between pressure rail switching events and a separate transition controller is used to deal with the pressure rail switching events. Two transition controllers are proposed, one uses the electric motor torque as the input, and the other also uses valve timing as a second input. For both transition controllers, a least norm control approach is used to steer the system states to the exact desired states at the end of the short transition period (~ 40 ms). The transition controllers are able to reduce the tracking error and the required electric motor torque, and hence achieve better control performance even with smaller electric components.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluation of Optimal Net Load Management in Microgrids Using Hardware-in-the-Loop Simulation

This paper presents the performance evaluation of a net load management (NLM) engine that balances load and generation in an isolated community to power a critical facility after a grid interruption event (e.g., the loss of a large generation unit). This NLM engine is particularly important for microgrid systems because it provides a high-speed, cost-optimal control solution to coordinate grid-forming inverters and to dispatch grid-following inverters and deferrable loads in microgrid systems to enhance grid resilience and reliability. The NLM algorithm cost-optimally dispatches the grid-following inverters and deferrable loads based on the demanded power and load priorities, and the grid-forming inverters use droop control to form system voltages and share active and reactive power. A controller-hardware-in-the-loop platform is developed to evaluate the control performance of the NLM algorithm with two sequential contingency events of lost generation units. The experimental results indicate that the NLM engine can maintain system stability, achieve the targeted system voltage and frequency, and balance load and generation to serve the critical facility with improved system resilience and reliability.

grid-following inverter↗

Overall chilled water system energy consumption modeling and optimization

The emergence of increasingly affordable variable-speed drive technology has changed the approach used to control chilled water systems equipped with these drives. The purpose of this research was to develop an integrated chilled water modeling technique that can determine the optimal system setpoints and estimate the energy saving potential of chiller system. The chiller system equipped with Variable Frequency Drives (VFDs) on cooling tower fans and condenser water pumps. To accomplish the objective, physical component models of the centrifugal chiller, cooling tower and condenser water pump were established with the goal of incorporating the system’s condenser water flow rate and cooling tower fan speeds as optimization variables. Furthermore, a cooling load prediction algorithm was developed using a multiple non-linear regression model to approximate the building’s cooling load subject to a range of environmental conditions. The inputs and outputs of the individual component models were linked to estimate how adjusting the cooling tower fan and condenser water pump speed would influence the system’s comprehensive performance. Here, the overall system model was then optimized using a generalized reduced gradient optimization algorithm to determine the potential energy savings through speed control with VFDs and to ascertain a control logic strategy for the building automation system to operate the heating and cooling system. A case-study was performed on a single chiller system at a museum and the model was calibrated according to logged data collected over four months. Results showed that for the system analyzed, the energy saving of optimizing the cooling tower fan system was found to be 12–15%, while the energy saving potential of optimizing the condenser water pump with the cooling tower fan was negligible. Additionally, comparing different cooling tower fan control strategies showed that a wet-bulb approach-based cooling tower control strategy was shown to have the highest correlation to the optimized fan speed with an R 2 of 0.924.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimal Protocols in Quantum Annealing and Quantum Approximate Optimization Algorithm Problems

Quantum annealing (QA) and the quantum approximate optimization algorithm (QAOA) are two special cases of the following control problem: apply a combination of two Hamiltonians to minimize the energy of a quantum state. Which is more effective has remained unclear. Here we analytically apply the framework of optimal control theory to show that generically, given a fixed amount of time, the optimal procedure has the pulsed (or “bang-bang”) structure of QAOA at the beginning and end but can have a smooth annealing structure in between. This is in contrast to previous works which have suggested that bang-bang (i.e., QAOA) protocols are ideal. To support this theoretical work, we carry out simulations of various transverse field Ising models, demonstrating that bang-anneal-bang protocols are more common. Futher, the general features identified here provide guideposts for the nascent experimental implementations of quantum optimization algorithms.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Deep Multi-Agent Reinforcement Learning for Real-World Signalized Traffic Corridor Control

Signalized traffic control problem has been addressed recently with deep Reinforcement Learning (RL) approaches involving diverse state, action, and reward structures. While significant progress has been noted in the literature, open challenges still remain in the areas of adaptive signal phase timing, coordination in a multi-intersection corridor setting, and consideration of real-world traffic conditions. In the context of deep RL-based problem framing, extensions are needed that enable adaptive signal phase timings in an intersection agent's action space, computationally efficient information sharing among neighboring signalized intersection agents along a corridor, and experimentation in realistic simulation environments. In this paper, we develop a deep Advantage Actor Critic (A2C) multi-agent RL (MARL) approach capturing the research extensions above and apply it within a real-world calibrated Aimsun Next traffic corridor simulation model based on traffic data from the City of Coral Gables, Florida. For a multi-intersection corridor control setting, our numerical simulation experiments with a decentralized A2C MARL algorithm applied at different time periods led to a total average corridor travel delay reduction (expressed in seconds/mile averaged over vehicles) from 4.9% to 19.9% compared to state-of-the-art actuated control.

Shuvo, Salman S. [BATTELLE (PACIFIC NW LAB)]↗

Engine-in-the-Loop Study of a Hierarchical Predictive Online Controller for Connected and Automated Heavy-Duty Vehicles

This paper presents a cohesive set of engine-in-the-loop (EIL) studies examining the use of hierarchical model-predictive control for fuel consumption minimization in a class-8 heavy-duty truck intended to be equipped with Level-1 connectivity/automation. This work is motivated by the potential of connected/automated vehicle technologies to reduce fuel consumption in both urban/suburban and highway scenarios. The authors begin by presenting a hierarchical model-predictive control scheme that optimizes multiple chassis and powertrain functionalities for fuel consumption. These functionalities include: vehicle routing, arrival/departure at signalized intersections, speed trajectory optimization, platooning, predictive optimal gear shifting, and engine demand torque shaping. The primary optimization goal is to minimize fuel consumption, but the hierarchical controller explicitly accounts for other key objectives/constraints, including operator comfort and safe inter-vehicle spacing. This work is experimentally experimentally validated via a sequence of EIL studies intended for evaluating the computational costs and fuel savings associated with these algorithms. These EIL studies involve the closed-loop validation of the proposed control strategies, both individually and combined. These studies show that this hierarchy of algorithms is capable of running online, with the round-trip communication delay inherent in EIL simulation being one of the key factors affecting the EIL results. Moreover, the EIL studies are encouraging, both in terms of the successful hierarchical integration of the underlying algorithms and also in the resulting fuel savings seen in the EIL tests. In particular, the EIL results suggest that an aggressive overall goal of reducing vehicle fuel consumption by 15-20% or more is potentially achievable, especially in urban/suburban scenarios.

33 ADVANCED PROPULSION SYSTEMS↗

Adaptive Deep Reinforcement Learning Algorithm for Distribution System Cyber Attack Defense With High Penetration of DERs

With grid modernization, smart inverters are increasingly used to execute advanced controls for distribution network reliability. However, this also increases the cyber-attack space. Here this paper focuses on the defense approaches to restore the system to normal operation circumstances in the presence of cyber-attacks. A unique deep reinforcement learning (DRL) method is developed to minimize voltage violations and reduce power losses for impacted feeders. The defense problem is reformulated as a Markov decision-making process to dynamically control DERs while minimizing load shedding. This is achieved via an improved soft actor-critic (SAC)-based DRL algorithm, which can govern DER set points and load-shedding scenarios in discrete and continuous modes via the auto-tune entropy and Gaussian policy features. Numerical comparison results on the modified IEEE 123-node system with other control approaches, such as Volt-VAR (VV), Volt-Watt (VW), and model predictive control (MPC) show that the proposed method can eliminate voltage violations and provide feasible control actions that perform complete mitigation of cyber-threats.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Resilient Autonomous Wind Farms

With the advent of an increasing number of control strategies that seek to optimize wind turbine performance on a farm level, taking into account individual wind turbine information to achieve wind-farm-level objectives has become an increasingly important goal. Methods for controlling wind turbines on an individual and farm level have experienced significant development, and an abundance of new implementations for gathering and using data from turbines have created potential for novel control mechanisms that can further optimize the performance and delivery characteristics of a wind farm. A key element of making these wind farms more efficient is to develop reliable algorithms that use local sensor information that is already being collected, such as from local meteorological stations, nearby radars, sodars, and lidars, and supervisory control and data acquisition (SCADA) data. Making use of information from all wind turbines in a wind farm can enable such approaches as determining the atmospheric conditions across the farm, improving fault-finding, and ensuring more efficient overall control of farmwide optimizations through mechanisms such as wake steering. However, these approaches typically involve a centralized communications and control center. In order to ensure the resilient operation of the farm, it is necessary to develop an approach that distributes the calculation and communication amongst multiple nodes throughout the farm. In this fashion, a redundant, robust, and secure network can be created, which can tolerate faults in calculation, communication, and even external attacks that seek to disrupt the operation of the wind farm. This paper introduces the use of the Raft-Byzantine-Fault-Tolerant algorithm in the implementation of autonomous control of a wind farm. This implementation will allow for fault tolerance for malfunctioning nodes, sensors, transmitters, and connectors. This approach is equally extensible to account for malicious actors. It will...

fault tolerance↗

Coordinated Self-Assembly of Networked Microgrids Using Irving’s Algorithm

Abstract— Microgrid installations have regained significant interest, driven by the increasing adoption of distributed energy resources, decentralized controls, and ongoing technological advancements. While the number of microgrids increases, there are opportunities to coordinate networks of microgrids. In this study, Irving’s algorithm is applied to a framework for the coordinated self-assembly of networked microgrids. Compared with the authors’ previous work, this new study relaxes the constraint on participated microgrids to have a single global objective. Thus, each microgrid can rank others according to its local preference. This reduces the amount of shared information, improves the privacy, and enhances the flexibility. The adaptability to that proposed framework is also maintained. Examples are presented to illustrate the networking processes and self-assembly operations.

Xie, Jing↗

Evaluation of Optimal Net Load Management in Microgrids Using Hardware-in-the-Loop Simulation: Preprint

This paper presents the performance evaluation of a net load management (NLM) engine that balances load and generation in an isolated community to power a critical facility after a grid interruption event (e.g., lost a large generation unit). The NLM engine is a central dispatch control system that provides high-speed cost-optimal coordination of a set of net loads (combination of generation and deferrable loads) connected to the same electrical network. The NLM algorithm cost-optimally dispatches the grid-following inverters and deferrable loads based on the demanded power and load priorities, and the grid-forming inverters use droop control to form system voltages and share active and reactive power. A controller-hardware-in-the-loop platform is developed to evaluate the control performance of the NLM algorithm. The experimental results indicate that the NLM engine can achieve the targeted system voltage and frequency and balance load and generation to serve the critical facility.

droop control↗

An Update to the National Renewable Energy Laboratory Baseline Wind Turbine Controller

The National Renewable Energy Laboratory's 5-MW wind turbine model is well established as an industry standard and is often used as a comparison model, or a model on which to build upon. Though effective, the legacy controller for the 5-MW wind turbine uses a simple algorithm that is not up to date with many industry standards. Additionally, as the research community has advanced into fast-paced development cycles, as systems engineering tools such as Wind-Plant Integrated System Design & Engineering Model (WISDEM ®) [1] are employed, and as a greater focus on controls co-design practices is encouraged, demand for a generic wind turbine controller has arisen. This work presents updates for the NREL 5-MW controller to a more modern control architecture, and establishes a generic tuning framework that can be easily adapted to various wind turbines. Based on initial results, the updated generic controller eases the automatic tuning process while maintaining or improving the performance of the legacy NREL 5-MW controller.

17 WIND ENERGY↗