Search NASA⌕ Search

SEARCH · Search NASA

Results for “INSTRUMENT ORIENTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

The Gamma Ray Observatory

The Gamma Ray Observatory (GRO), scheduled for launch by the Space Shuttle in April 1991, weighs 35,000 lbs and will offer 10 to 20 times better sensitivity than any previous gamma ray mission. The four instruments aboard GRO are described. The Burst and Transient Source Experiment (BATSE) will continuously monitor the entire sky for transient gamma-ray events using eight identical, wide-field detectors capable of measuring brightness variations lasting only milliseconds at energies from about 50,000 to 600,000 eV. The Oriented Scintillation Spectrometer Experiment (OSSE) will make comprehensive observations of discrete sources at energies from 100,000 to 10 million eV, where many radioactive elements have emission lines. The observatory's Imaging Compton Telescope will conduct a deep survey of the entire sky at gamma-ray energies between 1 and 30 MeV. The Energetic Gamma Ray Experiment Telescope will cover a broad high-energy spectral range, from about 20 million to 30 billion eV and conduct a sensitive all-sky survey with a wide field of view and good angular resolution.

Kniffen, Donald A.↗

Self-Sealing Wet Chemistry Cell for Field Analysis

In most analytical investigations, there is a need to process complex field samples for the unique detection of analytes, especially when detecting low concentration organic molecules that may identify extraterrestrial life. Wet chemistry based instruments are the techniques of choice for most laboratory- based analysis of organic molecules due to several factors including less fragmentation of fragile biomarkers, and ability to concentrate target species resulting in much lower limits of detection. Development of an automated wet chemistry preparation system that can operate autonomously on Earth and is also designed to operate under Martian ambient conditions will demonstrate the technical feasibility of including wet chemistry on future missions. An Automated Sample Processing System (ASPS) has recently been developed that receives fines, extracts organics through solvent extraction, processes the extract by removing non-organic soluble species, and delivers sample to multiple instruments for analysis (including for non-organic soluble species). The key to this system is a sample cell that can autonomously function under field conditions. As a result, a self-sealing sample cell was developed that can autonomously hermetically seal fines and powder into a container, regardless of orientation of the apparatus. The cap is designed with a beveled edge, which allows the cap to be self-righted as the capping motor engages. Each cap consists of a C-clip lock ring below a crucible O-ring that is placed into a groove cut into the sample cap.

Beegle, Luther W.↗

Doing Your Science While You're in Orbit

Abstract. Large-scale neutron facilities such as the Spallation Neutron Source (SNS) located at Oak Ridge National Laboratory need easy-to-use access to Department of Energy Leadership Computing Facilities and experiment repository data. The Orbiter thick- and thinclient and its supporting Service Oriented Architecture (SOA) based services (available at https://nucleus.sns.gov) consist of standards-based components that are reusable and extensible for accessing high performance computing, data and computational grid infrastructure, and cluster-based resources easily from a user configurable interface. The primary Orbiter system goals consist of (1) developing infrastructure for the creation and automation of virtual instrumentation experiment optimization, (2) developing user interfaces for thin- and thickclient access, (3) provide a prototype incorporating major instrument simulation packages, and (4) facilitate neutron science community access and collaboration. The secure Orbiter SOA authentication and authorization is achieved through the developed Virtual File System (VFS) services, which use Role-Based Access Control (RBAC) for data repository file access, thinand thick-client functionality and application access, and computational job workflow management. The VFS Relational Database Management System (RDMS) consists of approximately 43 database tables describing 429 user accounts with 437 groups over 451,000 directories with 739,618 repository files. Over 39 million NeXus file metadata records are associated to the 12,794 unique NeXus file field/class names generated from the 42,894 repository NeXus files. Services that enable (a) summary dashboards of data repository status with Quality of Service (QoS) metrics, (b) data repository NeXus file field/class name full text search capabilities within a Google like interface, (c) fully functional RBAC browser for the read-only data repository and shared areas, (d) user/group defined and shared metadata for data repository files, (e) user, group, repository, and web 2.0 based global positioning with additional service capabilities are currently available. The SNS based Orbiter SOA integration progress with the Distributed Data Analysis for Neutron Scattering Experiments (DANSE) software development project is summarized with an emphasis on DANSE Central Services and the Virtual Neutron Facility (VNF). Additionally, the DANSE utilization of the Orbiter SOA authentication, authorization, and data transfer services best practice implementations are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Seismic anisotropy of serpentinite from Val Malenco, Italy

Serpentinites, deformed in mantle subduction zones, are thought to contribute significantly to seismic anisotropy of the upper mantle and have therefore been of great interest with studies on deformation, preferred orientation, and elastic properties. Here we present a combined study of a classical sample from Val Malenco, Italy, investigating the microstructure and texture with state-of-the art synchrotron X-ray and neutron diffraction methods and measuring ultrasonic velocities both with a multi-anvil apparatus and a novel instrument to measure 3-D velocities on spheres. Both, results from diffraction methods and velocity measurements are compared, discussing advantages and disadvantages. From spherical velocities, elastic tensor properties can be derived by inversion. Also from quantitative texture measurements, elastic properties can be modeled by self-consistent averaging. We report good agreement between the velocity and microstructural models is observed.

58 GEOSCIENCES↗

PolLux: A new facility for soft x-ray spectromicroscopy at the Swiss Light Source

We report on the successful installation and operation of a scanning transmission x-ray microspectroscope (STXM) at the PolLux facility at the Swiss Light Source. This integration of an advanced STXM with improved sample handling capabilities and a novel beamline provides unique capabilities. PolLux uses linearly or circularly polarized x-rays from a bending magnet with an extended photon energy range (200-1400 eV). It is therefore well suited to determine a sample's quantitative chemical composition, molecular orientation, or thickness of organic as well as condensed matter materials. The local magnetic state of magnetic thin films is accessible through fast helicity switching by steering the electron beam off axis through the bending magnet. Ex vacuo girder movers allow fast and highly reproducible (<1 {mu}m) alignment of the instrument with respect to the photon beam. The present spatial resolution is {approx}20 nm, limited by the zone plates utilized. The instrument has the stability and positional resolution to operate with much higher resolution optics as it becomes available. In addition to characterization experiments, we present several typical examples from materials research and environmental science to exemplify the capabilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Qualification of a high-efficiency, gated spectrometer for x-ray Thomson scattering on the National Ignition Facility

We have designed, built, and successfully fielded a highly efficient and gated Bragg crystal spectrometer for x-ray Thomson scattering measurements on the National Ignition Facility (NIF). It utilizes a cylindrically curved Highly Oriented Pyrolytic Graphite crystal. Its spectral range of 7.4–10 keV is optimized for scattering experiments using a Zn He-α x-ray probe at 9.0 keV or Mo K-shell line emission around 18 keV in second diffraction order. The spectrometer has been designed as a diagnostic instrument manipulator-based instrument for the NIF target chamber at the Lawrence Livermore National Laboratory, USA. Here, we report on details of the spectrometer snout, its novel debris shield configuration and an in situ spectral calibration experiment with a Brass foil target, which demonstrated a spectral resolution of E/ΔE = 220 at 9.8 keV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray thermal diffuse scattering as a texture-robust temperature diagnostic for dynamically compressed solids

We present a model of x-ray thermal diffuse scattering (TDS) from a cubic polycrystal with an arbitrary crystallographic texture, based on the classic approach of Warren [B. E. Warren, Acta Crystallogr. 6, 803 (1953)]. We compare the predictions of our model with femtosecond x-ray diffraction patterns gathered from ambient and dynamically compressed rolled copper foils obtained at the High Energy Density instrument of the European X-Ray Free-Electron Laser facility and find that the texture-aware TDS model yields more accurate results than does the conventional powder model owed to Warren. Nevertheless, we further show: with sufficient angular detector coverage, the TDS signal is largely unchanged by sample orientation and in all cases strongly resembles the signal from a perfectly random powder; shot-to-shot fluctuations in the TDS signal resulting from grain-sampling statistics are at the percent level, in stark contrast to the fluctuations in the Bragg-peak intensities (which are over an order of magnitude greater); and TDS is largely unchanged even following texture evolution caused by compression-induced plastic deformation. We conclude that TDS is robust against texture variation, making it a flexible temperature diagnostic applicable just as well to off-the-shelf commercial foils as to ideal powders.

Crystal lattices↗

Advanced X-ray Astrophysics Facility thermal control

A conceptual active/passive thermal control system design is presented for the Advanced X-ray Astrophysics Facility (AXAF), where the design variables considered in system optimization were vehicle orientation for environmental extremes, thermal coating properties, and insulation materials. Because power and weight are at a premium, the design was limited to one power module, resulting in a thermal control limit of 441 W of regulated power. The present study has determined that all thermal control objectives for AXAF's instruments can be met by the design considered. The thermal resistance schematics employed in this conceptual study are presented, together with simulated performance characteristics.

Fritz, C. G.↗

Combined Velocity/Charge-To-Mass-Ratio Analyzer

Instrument analyzes ions according to velocity and ratio of mass to electric charge. State-of-the-art combination of two instruments: time-of-flight analyzer and electrostatic analyzer functioning as mass spectrometer. Features include compactness, light weight, and low power. Terrestrial versions useful in chemical analysis, chromatography, and analysis of plasmas.

Chutjian, Ara↗

Correcting the distortion of images taken with the ultraviolet imaging telescope

The Ultraviolet Imaging Telescope (UIT) cameras include two-stage magnetically focused image intensifiers that introduce small but significant geometrical distortions into the data. These distortions, which create positional offsets as large as 25 arcsec at the field edges, are corrected by the procedure described here to 2-3 arcsec, approximately the resolution of the images. The distortion is measured by comparing and correcting UIT images to digitized Guidestar survey plates of the same fields. Two-dimensional third-order polynomials are used to model the distortion. The models assume that the distortion is an instrumental effect, independent of mission elapsed time and target, and that the effect of distortion is an instrumental effect, independent of mission elapsed time and target, and that the effect of distortion in the center of each field is minimal. The models are used to improve computed astrometric plate solutions and to remove the geometric distortion while transforming the image to a standard north-up, ease-left orientation.

Greason, M. R.↗

Analysis of Photogrammetry Data from ISIM Mockup

During ground testing of the Integrated Science Instrument Module (ISIM) for the James Webb Space Telescope (JWST), the ISIM Optics group plans to use a Photogrammetry Measurement System for cryogenic calibration of specific target points on the ISIM composite structure and Science Instrument optical benches and other GSE equipment. This testing will occur in the Space Environmental Systems (SES) chamber at Goddard Space Flight Center. Close range photogrammetry is a 3 dimensional metrology system using triangulation to locate custom targets in 3 coordinates via a collection of digital photographs taken from various locations and orientations. These photos are connected using coded targets, special targets that are recognized by the software and can thus correlate the images to provide a 3 dimensional map of the targets, and scaled via well calibrated scale bars. Photogrammetry solves for the camera location and coordinates of the targets simultaneously through the bundling procedure contained in the V-STARS software, proprietary software owned by Geodetic Systems Inc. The primary objectives of the metrology performed on the ISIM mock-up were (1) to quantify the accuracy of the INCA3 photogrammetry camera on a representative full scale version of the ISIM structure at ambient temperature by comparing the measurements obtained with this camera to measurements using the Leica laser tracker system and (2), empirically determine the smallest increment of target position movement that can be resolved by the PG camera in the test setup, i.e., precision, or resolution. In addition, the geometrical details of the test setup defined during the mockup testing, such as target locations and camera positions, will contribute to the final design of the photogrammetry system to be used on the ISIM Flight Structure.

Nowak, Maria↗

Analysis of Photogrammetry Data from ISIM Mockup, June 1, 2007

During ground testing of the Integrated Science Instrument Module (ISIM) for the James Webb Space Telescope (JWST), the ISIM Optics group plans to use a Photogrammetry Measurement System for cryogenic calibration of specific target points on the ISIM composite structure and Science Instrument optical benches and other GSE equipment. This testing will occur in the Space Environmental Systems (SES) chamber at Goddard Space Flight Center. Close range photogrammetry is a 3 dimensional metrology system using triangulation to locate custom targets in 3 coordinates via a collection of digital photographs taken from various locations and orientations. These photos are connected using coded targets, special targets that are recognized by the software and can thus correlate the images to provide a 3 dimensional map of the targets, and scaled via well calibrated scale bars. Photogrammetry solves for the camera location and coordinates of the targets simultaneously through the bundling procedure contained in the V-STARS software.

Nowak, Maria↗

Corner-Cube Retroreflector Instrument for Advanced Lunar Laser Ranging

A paper describes how, based on a structural-thermal-optical-performance analysis, it has been determined that a single, large, hollow corner cube (170- mm outer diameter) with custom dihedral angles offers a return signal comparable to the Apollo 11 and 14 solid-corner-cube arrays (each consisting of 100 small, solid corner cubes), with negligible pulse spread and much lower mass. The design of the corner cube, and its surrounding mounting and casing, is driven by the thermal environment on the lunar surface, which is subject to significant temperature variations (in the range between 70 and 390 K). Therefore, the corner cube is enclosed in an insulated container open at one end; a narrow-bandpass solar filter is used to reduce the solar energy that enters the open end during the lunar day, achieving a nearly uniform temperature inside the container. Also, the materials and adhesive techniques that will be used for this corner-cube reflector must have appropriate thermal and mechanical characteristics (e.g., silica or beryllium for the cube and aluminum for the casing) to further reduce the impact of the thermal environment on the instrument's performance. The instrument would consist of a single, open corner cube protected by a separate solar filter, and mounted in a cylindrical or spherical case. A major goal in the design of a new lunar ranging system is a measurement accuracy improvement to better than 1 mm by reducing the pulse spread due to orientation. While achieving this goal, it was desired to keep the intensity of the return beam at least as bright as the Apollo 100-corner-cube arrays. These goals are met in this design by increasing the optical aperture of a single corner cube to approximately 170 mm outer diameter. This use of an "open" corner cube allows the selection of corner cube materials to be based primarily on thermal considerations, with no requirements on optical transparency. Such a corner cube also allows for easier pointing requirements, because there is no dependence on total internal reflection, which can fail off-axis.

Turyshev, Slava G.↗

Photovoltaic system derived data for determining the solar resource and for modeling the performance of other photovoltaic systems

Using performance data from some of the millions of installed photovoltaic (PV) modules with micro-inverters may afford the opportunity to provide ground-based solar resource data critical for developing PV projects. Here, a method was developed to back-solve for the direct normal irradiance (DNI) and the diffuse horizontal irradiance (DHI) from the measured ac power of south-facing PV module/micro-inverter systems. The method was validated using one year of irradiance and PV performance measurements for five PV systems, each with a different tilt/azimuth orientation, and located in Golden, Colorado. Compared to using a measured global horizontal irradiance for PV performance model input, using the back-solved values of DNI and DHI only increased the range of mean bias deviations from measured values by 0.6% for the modeled annual averages of the global tilt irradiance and ac power for the five PV systems. Correcting for angle-of-incidence effects is an important feature of the method to prevent underestimating the solar resource and for modeling the performance of PV systems with more dissimilar PV module orientations. The results for the method were also shown more favorable than the results when using an existing power projection method for estimating the ac power.

14 SOLAR ENERGY↗

X-ray tomography of extended objects: a comparison of data acquisition approaches

The penetration power of x-rays allows one to image large objects while their short wavelength allows for high spatial resolution. As a result, with synchrotron sources one has the potential to obtain tomographic images of centimeter-sized specimens with sub-micrometer pixel sizes. However, limitations on beam and detector size make it difficult to acquire such data of this sort in a single take, necessitating strategies for combining data from multiple regions. One strategy is to acquire a tiled set of local tomograms by rotating the specimen around each of the local tomogram center positions. Another strategy, sinogram oriented acquisition, involves the collection of projections at multiple offset positions from the rotation axis followed by data merging and reconstruction. We have carried out a simulation study to compare these two approaches in terms of radiation dose applied to the specimen, and reconstructed image quality. Local tomography acquisition involves an easier data alignment problem, and immediate viewing of subregions before the entire dataset has been acquired. Sinogram oriented acquisition involves a more difficult data assembly and alignment procedure, and it is more sensitive to accumulative registration error. Furthermore, sinogram oriented acquisition is more dose-efficient, it involves fewer translation motions of the object, and it avoids certain artifacts of local tomography.

47 OTHER INSTRUMENTATION↗

Urban Traveler - Changes and Impacts: Mobility Energy Productivity (MEP) Metric

For nearly a century, the automobile has been the primary mode of personal transportation in American life. This remains true today as millions of people rely heavily on cars to connect suburbs with cities or to travel long distances—often out of routine or convenience. However, advances in technology are fueling an era of transportation transformation, with the potential to transform a system that has remained virtually unchanged for decades. Aspiring smart cities are wrestling with questions such as: How does mobility impact a person’s quality of life? Would people make different travel choices if they were presented with better information about their mobility options? The ability to quantify the mobility potential of a given location is the first step toward answering these questions. In response, an interdisciplinary team at the National Renewable Energy Laboratory (NREL) has developed the Mobility-Energy Productivity (MEP) metric. The MEP metric provides an avenue to not only measure the mobility potential at a specific location in its current configuration, but also to test how various technological advances (e.g., connected and automated vehicles, plug-in electric vehicles, shared mobility) and infrastructure investments (e.g., building an additional highway lane, constructing a new shopping mall, implementing a transit-oriented development) impact the mobility of that location over time. This presentation details the FY19 progress on the MEP metric project funded through DOE VTO's SMART Mobility Consortium.

47 OTHER INSTRUMENTATION↗

An Evaluation of the Iosipescu Specimen for Composite Materials Shear Property Measurement

A detailed evaluation of the suitability of the Iosipescu specimen tested in the modified Wyoming fixture is presented. An experimental investigation using conventional strain gage instrumentation and moire interferometry is performed. A finite element analysis of the Iosipescu shear test for unidirectional and cross-ply composites is used to assess the uniformity of the shear stress field in the vicinity of the notch, and demonstrate the effect of the nonuniform stress field upon the strain gage measurements used for the determination of composite shear moduli. From the test results for graphite-epoxy laminates, it is shown that the proximity of the load introduction point to the test section greatly influences the individual gage readings for certain fiber orientations but the effect upon shear modulus measurement is relatively unimportant. A numerical study of the load contact effect shows the sensitivity of some fiber configurations to the specimen/fixture contact mechanism and may account for the variations in the measured shear moduli. A comparison of the strain gage readings from one surface of a specimen with corresponding data from moire interferometry on the opposite face documented an extreme sensitivity of some fiber orientations to eccentric loading which induced twisting and yielded spurious shear stress-strain curves. In the numerical analysis, it is shown that the Iosipescu specimens for different fiber orientations have to be modeled differently in order to closely approximate the true loading conditions. Correction factors are needed to allow for the nonuniformity of the strain field and the use of the average shear stress in the shear modulus evaluation. The correction factors, which are determined for the region occupied by the strain gage rosette, are found to be dependent upon the material orthotropic ratio and the finite element models. Based upon the experimental and numerical results, recommendations for improving the reliability and accuracy of the shear modulus values are made, and the implications for shear strength measurement discussed. Further application of the Iosipescu shear test to woven fabric composites is presented. The limitations of the traditional strain gage instrumentation on the satin weave and high tow plain weave fabrics is discussed. Test results of a epoxy based aluminum particulate composite is also presented. A modification of the Iosipescu specimen is proposed and investigated experimentally and numerically. It is shown that the proposed new specimen design provides a more uniform shear stress field in the test section and greatly reduces the normal and shear stress concentrations in the vicinity of the notches. While the fabrication and the material cost of the proposed specimen is tremendously reduced, it is shown the accuracy of the shear modulus measurement is not sacrificed.

Ho, Henjen↗