Search NASA⌕ Search

SEARCH · Search NASA

Results for “Image Comparison”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

MRI of prostate brachytherapy seeds at high field: A study in phantom

Postimplant evaluation of prostate brachytherapy using magnetic resonance imaging (MRI) at 1.5 T has met with some difficulties due to the uncertainty associated with seed localization despite the excellent anatomical delineation this imaging modality can achieve. Seeds in vascularized regions or outside the prostate, where signal heterogeneity or drop off can obscure their position, can be difficult to identify. The increase in SNR available at 3.0 T offers the potential to improve these issues with visualization. However, before moving directly to in vivo studies, it is important to investigate the effects of artifact size on the ability to localize multiple seeds in close proximity. These artifacts are of extra concern at higher field because of the increased induced field distortions surrounding the seeds. A single prostate brachytherapy seed (IMC6711, OncoSeed) and arrays of seed pairs were suspended in a porcine gel medium and imaged on 1.5 and 3 T MRI scanners for comparison. Two basic acquisition techniques utilized in a wide array of clinical sequences [spin-echo based and gradient-echo (GE) based] were investigated for the types of artifacts they produce, and their dependence on field. Analysis of the resulting voids was performed to determine the relative size of seeds as seen on the images, as well as the ability to distinguish seeds at close proximity. The seed voids at 3 T were only slightly larger than those obtained at 1.5 T (0.5 mm longer and wider) when using a spin-echo type sequence. For this work, the authors used a proton density fast spin-echo (FSE) sequence. These results are promising for the use of 3 T imaging for postimplant evaluation since the SNR will increase by roughly a factor of 2 with only a limited corresponding increase in artifact size. The minimum separation of the seeds to be completely distinguished using void analysis increased from between 1.5 and 3 mm to between 3 and 4.5 mm when going from 1.5 to 3 T FSE imaging. The minimum separation of the seeds for GE at the demonstration TE of 11 ms was found to be between 3 and 4.5 mm for 1.5 T and between 4.5 and 6 mm for 3 T. These GE artifact dimensions will scale down with TE and, as this happens, approach the dimensions of the FSE artifacts given above.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-I-73: Surface Dose from KV Diagnostic Beams From An On-Board Imager On a Linac Machine Using Different Imaging Techniques and Filters

Purpose: To quantitatively investigate the surface dose deposited in patients imaged with a kV on-board-imager mounted on a radiotherapy machine using different clinical imaging techniques and filters. Methods: A high sensitivity photon diode is used to measure the surface dose on central-axis and at an off-axis-point which is mounted on the top of a phantom setup. The dose is measured for different imaging techniques that include: AP-Pelvis, AP-Head, AP-Abdomen, AP-Thorax, and Extremity. The dose measurements from these imaging techniques are combined with various filtering techniques that include: no-filter (open-field), half-fan bowtie (HF), full-fan bowtie (FF) and Cu-plate filters. The relative surface dose for different imaging and filtering techniques is evaluated quantiatively by the ratio of the dose relative to the Cu-plate filter. Results: The lowest surface dose is deposited with the Cu-plate filter. The highest surface dose deposited results from open fields without filter and it is nearly a factor of 8–30 larger than the corresponding imaging technique with the Cu-plate filter. The AP-Abdomen technique delivers the largest surface dose that is nearly 2.7 times larger than the AP-Head technique. The smallest surface dose is obtained from the Extremity imaging technique. Imaging with bowtie filters decreases the surface dose by nearly 33% in comparison with the open field. The surface doses deposited with the HF or FF-bowtie filters are within few percentages. Image-quality of the radiographic images obtained from the different filtering techniques is similar because the Cu-plate eliminates low-energy photons. The HF- and FF-bowtie filters generate intensity-gradients in the radiographs which affects image-quality in the different imaging technique. Conclusion: Surface dose from kV-imaging decreases significantly with the Cu-plate and bowtie-filters compared to imaging without filters using open-field beams. The use of Cu-plate filter does not affect image-quality and may be used as the default in the different imaging techniques.

60 APPLIED LIFE SCIENCES↗

MO-FG-CAMPUS-JeP2-01: 4D-MRI with 3D Radial Sampling and Self-Gating-Based K-Space Sorting: Image Quality Improvement by Slab-Selective Excitation

Purpose: A recent 4D MRI technique based on 3D radial sampling and self-gating-based K-space sorting has shown promising results in characterizing respiratory motion. However due to continuous acquisition and potentially drastic k-space undersampling resultant images could suffer from low blood-to-tissue contrast and streaking artifacts. In this study 3D radial sampling with slab-selective excitation (SS) was proposed in attempt to enhance blood-to-tissue contrast by exploiting the in-flow effect and to suppress the excess signal from the peripheral structures particularly in the superior-inferior direction. The feasibility of improving image quality by using this approach was investigated through a comparison with the previously developed non-selective excitation (NS) approach. Methods: Two excitation approaches SS and NS were compared in 5 cancer patients (1 lung 1 liver 2 pancreas and 1 esophagus) at 3Tesla. Image artifact was assessed in all patients on a 4-point scale (0: poor; 3: excellent). Signal-tonoise ratio (SNR) of the blood vessel (aorta) at the center of field-of-view and its nearby tissue were measured in 3 of the 5 patients (1 liver 2 pancreas) and blood-to-tissue contrast-to-noise ratio (CNR) were then determined. Results: Compared with NS the image quality of SS was visually improved with overall higher signal in all patients (2.6±0.55 vs. 3.4±0.55). SS showed an approximately 2-fold increase of SNR in the blood (aorta: 16.39±1.95 vs. 32.19±7.93) and slight increase in the surrounding tissue (liver/pancreas: 16.91±1.82 vs. 22.31±3.03). As a result the blood-totissue CNR was dramatically higher in the SS method (1.20±1.20 vs. 9.87±6.67). Conclusion: The proposed 3D radial sampling with slabselective excitation allows for reduced image artifact and improved blood SNR and blood-to-tissue CNR. The success of this technique could potentially benefit patients with cancerous tumors that have invaded the surrounding blood vessels where radiation therapy is needed to remove tumor from those regions prior to surgical resection. This work is partially supported by NIH R03CA173273; and CTSI core voucher award.

60 APPLIED LIFE SCIENCES↗

Assessing and accounting for the impact of respiratory motion on FDG uptake and viable volume for liver lesions in free-breathing PET using respiration-suspended PET images as reference

Purpose: To assess and account for the impact of respiratory motion on the variability of activity and volume determination of liver tumor in positron emission tomography (PET) through a comparison between free-breathing (FB) and respiration-suspended (RS) PET images. Methods: As part of a PET/computed tomography (CT) guided percutaneous liver ablation procedure performed on a PET/CT scanner, a patient's breathing is suspended on a ventilator, allowing the acquisition of a near-motionless PET and CT reference images of the liver. In this study, baseline RS and FB PET/CT images of 20 patients undergoing thermal ablation were acquired. The RS PET provides near-motionless reference in a human study, and thereby allows a quantitative evaluation of the effect of respiratory motion on PET images obtained under FB conditions. Two methods were applied to calculate tumor activity and volume: (1) threshold-based segmentation (TBS), estimating the total lesion glycolysis (TLG) and the segmented volume and (2) histogram-based estimation (HBE), yielding the background-subtracted lesion (BSL) activity and associated volume. The TBS method employs 50% of the maximum standardized uptake value (SUV{sub max}) as the threshold for tumors with SUV{sub max} ≥ 2× SUV{sub liver-bkg}, and tumor activity above this threshold yields TLG{sub 50%}. The HBE method determines local PET background based on a Gaussian fit of the low SUV peak in a SUV-volume histogram, which is generated within a user-defined and optimized volume of interest containing both local background and lesion uptakes. Voxels with PET intensity above the fitted background were considered to have originated from the tumor and used to calculate the BSL activity and its associated lesion volume. Results: Respiratory motion caused SUV{sub max} to decrease from RS to FB by −15% ± 11% (p = 0.01). Using TBS method, there was also a decrease in SUV{sub mean} (−18% ± 9%, p = 0.01), but an increase in TLG{sub 50%} (18% ± 36%) and in the segmented volume (47% ± 52%, p = 0.01) from RS to FB PET images. The background uptake in normal liver was stable, 1% ± 9%. In contrast, using the HBE method, the differences in both BSL activity and BSL volume from RS to FB were −8% ± 10% (p = 0.005) and 0% ± 16% (p = 0.94), respectively. Conclusions: This is the first time that almost motion-free PET images of the human liver were acquired and compared to free-breathing PET. The BSL method's results are more consistent, for the calculation of both tumor activity and volume in RS and FB PET images, than those using conventional TBS. This suggests that the BSL method might be less sensitive to motion blurring and provides an improved estimation of tumor activity and volume in the presence of respiratory motion.

60 APPLIED LIFE SCIENCES↗

THE MASSIVE PROGENITOR OF THE POSSIBLE TYPE II-LINEAR SUPERNOVA 2009hd IN MESSIER 66

We present early- and late-time photometric and spectroscopic observations of supernova (SN) 2009hd in the nearby spiral galaxy NGC 3627 (M66). This SN is one of the closest to us in recent years and provides an uncommon opportunity to observe and study the nature of SNe. However, the object was heavily obscured by dust, rendering it unusually faint in the optical given its proximity. We find that the observed properties of SN 2009hd support its classification as a possible Type II-Linear SN (SN II-L), a relatively rare subclass of core-collapse SNe. High-precision relative astrometry has been employed to attempt to identify an SN progenitor candidate, based on a pixel-by-pixel comparison between Hubble Space Telescope (HST) F555W and F814W images of the SN site prior to explosion and at late times. A progenitor candidate is identified in the F814W images only; this object is undetected in F555W. Significant uncertainty exists in the astrometry, such that we cannot definitively identify this object as the SN progenitor. Via insertion of artificial stars into the pre-SN HST images, we are able to constrain the progenitor's properties to those of a possible supergiant, with intrinsic absolute magnitude M {sup 0}{sub F555W} {approx}> -7.6 mag and intrinsic color (V - I){sup 0} {approx}> 0.99 mag. The magnitude and color limits are consistent with a luminous red supergiant (RSG); however, they also allow for the possibility that the star could have been more yellow than red. From a comparison with theoretical massive-star evolutionary tracks which include rotation and pulsationally enhanced mass loss, we can place a conservative upper limit on the initial mass for the progenitor of M{sub ini} {approx}< 20 M{sub Sun }. If the actual mass of the progenitor is near the upper range allowed by our derived mass limit, then it would be consistent with that for the identified progenitors of the SN II-L 2009kr and the high-luminosity SN II-Plateau (II-P) 2008cn. The progenitors of these three SNe may possibly bridge the gap between lower-mass RSGs that explode as SNe II-P and luminous blue variables, or more extreme RSGs, from which the more exotic SNe II-narrow may arise. Very late time imaging of the SN 2009hd site may provide us with more clues regarding the true nature of its progenitor.

79 ASTRONOMY AND ASTROPHYSICS↗

Predicting U 3 O 8 powder processing conditions: An AI/ML approach analyzing deep learning embeddings of SEM micrographs

High-resolution SEM images of uranium-oxide powders encode micro- and nanoscale clues to their synthesis route and calcination temperature. We trained a ResNet-50 model on 11 commercial-scale U₃O₈ classes, ammonium diuranate (ADU) or uranyl peroxide (H₂O₂) precursors calcined at temperatures ranging from 400 to 750 °C and added a 256-D projection head before the classifier to analyze the learned representation. The best of eight seeds reached 92.4 % accuracy on reserved testing data, but our focus is the structure of the embedding space rather than the accuracy and labels. We quantify class relatedness in the original 256-D space using centroid similarity and distributional distances, and we use Uniform Manifold Approximation Projection (UMAP) for visualization. ‘Unknown’ images from different preparation methods, SEM operators, and from the literature localized near the expected classes under a nearest-centroid analysis without retraining, as well as clustered in similar UMAP space. In conclusion, this embedding-centered workflow complements black-box classification by providing quantitative, similarity-based comparisons of U₃O₈ morphologies and reduces storage space by up to 98 % for image data used in millisecond vector search comparisons.

36 MATERIALS SCIENCE↗

Study of the electrothermal and MHD instabilities in exploding cylindrical foil liner

Abstract An experimental and numerical study of the plasma instabilities in an electrical exploding cylindrical Al liner is reported. The Al liner 3 mm in diameter and 10 μ m in thickness is exploded at the Qin-1 facility (450 ns, 400 kA). Various diagnostics, such as multi-frame laser shadowgraphy, an x-ray framing camera, and an x-ray backlighting system are developed. The different imaging systems are sensitive to plasma of different areal densities based on the comparison between the experiments and simulation, which reveal the dynamics of the exploding liner in more detail. The laser shadow images show the low-density plasma (∼1–2 × 10 −4 g cm −2 ) at the edge of the liner, and both the amplitude and wavelength of the plasma instabilities increase over time, which are considered to be magnetohydrodynamic (MHD) instabilities rather than electrothermal instabilities. During the ablation of the liner, quasi-periodic azimuthally correlated striations are directly observed in extreme ultraviolet (EUV) self-emission images. Meanwhile, the vertical filaments, which are electrothermal instabilities for plasma under the condition of ∂ η /∂ T < 0, are also observed in EUV self-emission images. The x-ray backlighting images of the exploding liner are obtained by placing an X -pinch load on the current-return path to serve as an x-ray point source (∼1 ns, ∼10 μ m). The x-ray backlighting results show the behavior of the high-density plasma (∼1.89 × 10 −3 g cm −2 ), which includes the transition from electrothermal to MHD instabilities. Finally, we realized a 2D MHD simulation of the exploding liner under experimental conditions, which shows good agreement with the results of the experimental perturbation.

Physics↗

SU-C-209-02: 3D Fluoroscopic Image Generation From Patient-Specific 4DCBCT-Based Motion Models Derived From Clinical Patient Images

Purpose: We develop a method to generate time varying volumetric images (3D fluoroscopic images) using patient-specific motion models derived from four-dimensional cone-beam CT (4DCBCT). Methods: Motion models are derived by selecting one 4DCBCT phase as a reference image, and registering the remaining images to it. Principal component analysis (PCA) is performed on the resultant displacement vector fields (DVFs) to create a reduced set of PCA eigenvectors that capture the majority of respiratory motion. 3D fluoroscopic images are generated by optimizing the weights of the PCA eigenvectors iteratively through comparison of measured cone-beam projections and simulated projections generated from the motion model. This method was applied to images from five lung-cancer patients. The spatial accuracy of this method is evaluated by comparing landmark positions in the 3D fluoroscopic images to manually defined ground truth positions in the patient cone-beam projections. Results: 4DCBCT motion models were shown to accurately generate 3D fluoroscopic images when the patient cone-beam projections contained clearly visible structures moving with respiration (e.g., the diaphragm). When no moving anatomical structure was clearly visible in the projections, the 3D fluoroscopic images generated did not capture breathing deformations, and reverted to the reference image. For the subset of 3D fluoroscopic images generated from projections with visibly moving anatomy, the average tumor localization error and the 95th percentile were 1.6 mm and 3.1 mm respectively. Conclusion: This study showed that 4DCBCT-based 3D fluoroscopic images can accurately capture respiratory deformations in a patient dataset, so long as the cone-beam projections used contain visible structures that move with respiration. For clinical implementation of 3D fluoroscopic imaging for treatment verification, an imaging field of view (FOV) that contains visible structures moving with respiration should be selected. If no other appropriate structures are visible, the images should include the diaphragm. This project was supported, in part, through a Master Research Agreement with Varian Medical Systems, Inc, Palo Alto, CA.

60 APPLIED LIFE SCIENCES↗

SU-D-202-02: Quantitative Imaging: Correlation Between Image Feature Analysis and the Accuracy of Manually Drawn Contours On PET Images

Purpose: To evaluate the correlation between image features and the accuracy of manually drawn target contours on synthetic PET images Methods: A digital PET phantom was used in combination with Monte Carlo simulation to create a set of 26 simulated PET images featuring a variety of tumor shapes and activity heterogeneity. These tumor volumes were used as a gold standard in comparisons with manual contours delineated by 10 radiation oncologist on the simulated PET images. Metrics used to evaluate segmentation accuracy included the dice coefficient, false positive dice, false negative dice, symmetric mean absolute surface distance, and absolute volumetric difference. Image features extracted from the simulated tumors consisted of volume, shape complexity, mean curvature, and intensity contrast along with five texture features derived from the gray-level neighborhood difference matrices including contrast, coarseness, busyness, strength, and complexity. Correlation between these features and contouring accuracy were examined. Results: Contour accuracy was reasonably well correlated with a variety of image features. Dice coefficient ranged from 0.7 to 0.90 and was correlated closely with contrast (r=0.43, p=0.02) and complexity (r=0.5, p<0.001). False negative dice ranged from 0.10 to 0.50 and was correlated closely with contrast (r=0.68, p<0.001) and complexity (r=0.66, p<0.001). Absolute volumetric difference ranged from 0.0002 to 0.67 and was correlated closely with coarseness (r=0.46, p=0.02) and complexity (r=0.49, p=0.008). Symmetric mean absolute difference ranged from 0.02 to 1 and was correlated closely with mean curvature (r=0.57, p=0.02) and contrast (r=0.6, p=0.001). Conclusion: The long term goal of this study is to assess whether contouring variability can be reduced by providing feedback to the practitioner based on image feature analysis. The results are encouraging and will be used to develop a statistical model which will enable a prediction of contour accuracy based purely on image feature analysis.

60 APPLIED LIFE SCIENCES↗

First Experience With Real-Time EPID-Based Delivery Verification During IMRT and VMAT Sessions

Purpose: Gantry-mounted megavoltage electronic portal imaging devices (EPIDs) have become ubiquitous on linear accelerators. WatchDog is a novel application of EPIDs, in which the image frames acquired during treatment are used to monitor treatment delivery in real time. We report on the preliminary use of WatchDog in a prospective study of cancer patients undergoing intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) and identify the challenges of clinical adoption. Methods and Materials: At the time of submission, 28 cancer patients (head and neck, pelvis, and prostate) undergoing fractionated external beam radiation therapy (24 IMRT, 4 VMAT) had ≥1 treatment fraction verified in real time (131 fractions or 881 fields). EPID images acquired continuously during treatment were synchronized and compared with model-generated transit EPID images within a frame time (∼0.1 s). A χ comparison was performed to cumulative frames to gauge the overall delivery quality, and the resulting pass rates were reported graphically during treatment delivery. Every frame acquired (500-1500 per fraction) was saved for postprocessing and analysis. Results: The system reported the mean ± standard deviation in real time χ 91.1% ± 11.5% (83.6% ± 13.2%) for cumulative frame χ analysis with 4%, 4 mm (3%, 3 mm) criteria, global over the integrated image. Conclusions: A real-time EPID-based radiation delivery verification system for IMRT and VMAT has been demonstrated that aims to prevent major mistreatments in radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of atlas-based auto-segmentation software in prostate cancer patients

The performance and limitations of an atlas-based auto-segmentation software package (ABAS; Elekta Inc.) was evaluated using male pelvic anatomy as the area of interest. Contours from 10 prostate patients were selected to create atlases in ABAS. The contoured regions of interest were created manually to align with published guidelines and included the prostate, bladder, rectum, femoral heads and external patient contour. Twenty-four clinically treated prostate patients were auto-contoured using a randomised selection of two, four, six, eight or ten atlases. The concordance between the manually drawn and computer-generated contours were evaluated statistically using Pearson's product–moment correlation coefficient (r) and clinically in a validated qualitative evaluation. In the latter evaluation, six radiation therapists classified the degree of agreement for each structure using seven clinically appropriate categories. The ABAS software generated clinically acceptable contours for the bladder, rectum, femoral heads and external patient contour. For these structures, ABAS-generated volumes were highly correlated with ‘as treated’ volumes, manually drawn; for four atlases, for example, bladder r = 0.988 (P < 0.001), rectum r = 0.739 (P < 0.001) and left femoral head r = 0.560 (P < 0.001). Poorest results were seen for the prostate (r = 0.401, P < 0.05) (four atlases); however this was attributed to the comparison prostate volume being contoured on magnetic resonance imaging (MRI) rather than computed tomography (CT) data. For all structures, increasing the number of atlases did not consistently improve accuracy. ABAS-generated contours are clinically useful for a range of structures in the male pelvis. Clinically appropriate volumes were created, but editing of some contours was inevitably required. The ideal number of atlases to improve generated automatic contours is yet to be determined.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Influence of Contrast Agent Dilution on Ballon Deflation Time and Visibility During Tracheal Balloon Dilation: A 3D Printed Phantom Study

PurposeTo determine the effect of contrast medium dilution during tracheal balloon dilation on balloon deflation time and visibility using a 3-dimensional (3D) printed airway phantom.Materials and MethodsA comparison study to investigate balloon deflation times and image quality was performed using two contrast agents with different viscosities, i.e., iohexol and ioxithalamate, and six contrast dilutions with a 3D printed airway phantom.ResultsCompared to 1:0 concentration, 3:1, 2:1, 1:1, 1:2, and 1:3, contrast/saline ratios resulted in a 46% (56.2 s), 59.8% (73.1 s), 74.9% (91.6 s), 81.7% (99.8 s), and 83.5% (102 s) reduction for iohexol, respectively, and a 51.8% (54.7 s), 63.8% (67.6 s), 74.7% (79.2 s), 80.5% (85.3 s), and 82.4% (87.4 s) reduction for ioxithalamate, respectively, in the mean balloon deflation time, although at the expense of decreased balloon opacity (3.5, 6.9, 11.1, 12.4, and 13.9%, for iohexol, respectively, and 3.2, 6, 9.6, 10.8, and 12.4%, for ioxithalamate, respectively).ConclusionsUse of a lower viscosity contrast agent and higher contrast dilution is considered to be able to reduce balloon deflation times and then simultaneously decrease visualization of balloons. The rapid balloon deflation time is likely to improve the safe performance of interventional procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Spray flow structure from twin-hole diesel injector nozzles

Two techniques were used to study non-evaporating diesel sprays from common rail injectors which were equipped with twin-hole and single-hole nozzles for comparison. To characterise the sprays, high speed optical imaging and x-ray radiography were used. The former was performed at the LTRAC laboratory at Monash University, while the latter was performed at the 7-BM beamline of the Advanced Photon Source at Argonne National Laboratory. The optical imaging made use of high temporal, high spatial resolution spray recordings on a digital camera from which peripheral parameters in the initial injection phase were investigated based on edge detection. The x-ray radiography was used to explore quantitative mass distributions, which were measured on a point-wise basis at roughly similar sampling rate. Three twin-hole nozzles of different subtended angles and a single-hole nozzle were investigated at injection pressure of 1000 bar in environments of 20 bar back pressure. Evidence of strong cavitation was found for all nozzles examined with their C D ranging from 0.62 to 0.69. Penetration of the twin-hole nozzles was found to lag the single-hole nozzle, even before the sprays merged. Finally, switching in hole dominance was observed from one twin-hole nozzle, and this was accompanied by greater instability in mass flow during the transient opening phase of the injector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of automated chemical-guided segmentation and human annotation of soil organic matter in X-ray microcomputed tomography imaging in contrasted soil types

Soil organic matter (OM) formation and persistence is strongly influenced by the spatial distribution of organic substrates and microscale soil heterogeneity by dictating OM accessibility to microorganisms. However, traditional size and/or density fractionation techniques disrupt aggregate architecture, eliminating spatial information needed to fully understand intra-aggregate OM distribution. To quantify three-dimensional OM spatial distribution and automate segmentation in X-ray microcomputed tomography (µCT) imaging without human annotation bias, we developed an iodine gas vapor (I2) based staining workflow that eliminates labor-intensive manual annotation while maintaining segmentation accuracy, using aggregates from four taxonomically diverse soils (Xerofluvent, Haploxeroll Sphagnofibrist, Palehumult) with an 8-fold range of soil organic carbon. Human annotation of 10 µCT slices by the experienced and inexperienced annotators resulted in variations up to 3% in the Dice similarity coefficient (DSC), reflecting a degree of inherent subjectivity of manual labeling. Such inconsistencies are expected to compound as the number of manually annotated slices increases. Dual-energy µCT imaging at 33.1 keV (below the iodine (I) K-edge) and 33.2 keV (above the I K-edge) was used to resolve aggregate microstructure following I2 staining. The automated image subtraction pipeline identified OM regions by the I Kedge induced brightness increases, achieving DSC values of 0.58–0.83 relative to an experienced annotator. Sensitivity analyses revealed that the reconstruction alpha value—optimized via the open-source tool TomocuPy—and the 3D registration slice count were the primary determinants of accuracy, providing a novel benchmark for dual-energy soil imaging. The pipeline without GPU acceleration achieved 9.6 to 43.2 times faster than manual annotation. Using GPU-accelerated image post-processing and affine transformation matrices, the pipeline successfully segmented OM elements for large-scale datasets (3232×3232 pixel, 2048 slices) within ~5200 s from raw file acquisition to segmented output. The high-throughput approach enables the quantification of OM spatial distribution across diverse and heterogeneous soil.

Soil microbial biomass↗

Comparison of Rigid and Adaptive Methods of Propagating Gross Tumor Volume Through Respiratory Phases of Four-Dimensional Computed Tomography Image Data Set

Purpose: To compare three different methods of propagating the gross tumor volume (GTV) through the respiratory phases that constitute a four-dimensional computed tomography image data set. Methods and Materials: Four-dimensional computed tomography data sets of 20 patients who had undergone definitive hypofractionated radiotherapy to the lung were acquired. The GTV regions of interest (ROIs) were manually delineated on each phase of the four-dimensional computed tomography data set. The ROI from the end-expiration phase was propagated to the remaining nine phases of respiration using the following three techniques: (1) rigid-image registration using in-house software, (2) rigid image registration using research software from a commercial radiotherapy planning system vendor, and (3) rigid-image registration followed by deformable adaptation originally intended for organ-at-risk delineation using the same software. The internal GTVs generated from the various propagation methods were compared with the manual internal GTV using the normalized Dice similarity coefficient (DSC) index. Results: The normalized DSC index of 1.01 {+-} 0.06 (SD) for rigid propagation using the in-house software program was identical to the normalized DSC index of 1.01 {+-} 0.06 for rigid propagation achieved with the vendor's research software. Adaptive propagation yielded poorer results, with a normalized DSC index of 0.89 {+-} 0.10 (paired t test, p <0.001). Conclusion: Propagation of the GTV ROIs through the respiratory phases using rigid- body registration is an acceptable method within a 1-mm margin of uncertainty. The adaptive organ-at-risk propagation method was not applicable to propagating GTV ROIs, resulting in an unacceptable reduction of the volume and distortion of the ROIs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Shock compression of a low-density carbon foam

Porous polymer foams are found in numerous applications where they may be subjected to dynamic compression. The shockwave properties of polymer foams have several features that make shock Hugoniot measurements and interpretation challenging. Here, we present a comparison of dynamic X-ray phase contrast imaging and traditional optical velocimetry approaches to measuring the shocked states for a low-density carbon foam. Overall, dynamic X-ray phase contrast imaging was found to reduce errors associated with the measured Hugoniot states. In this study, the foam exhibits anomalous compression as expected due to its high initial porosity arising from shock heating.

36 MATERIALS SCIENCE↗

Visualization of post-detonation fireball flowfields and comparison to CFD modeling

Visualization of flow structures within post-detonation fireballs has been performed for benchmark validation of numerical simulations. Custom pressed PETN explosives with a 12-mm diameter hemispherical form factor were used to produce a spherically symmetric post-detonation flow with low soot yield. Hydroxyl-radical planar laser induce fluorescence (OH-PLIF) was employed to visualize the structure ranging from approximately 10 μs to 35 μs after shock breakout from the explosive pellet. Fireball simulations were performed using the HyBurn Computational Fluid Dynamics (CFD) package. Experimental OH-PLIF results were compared to synthetic OH-PLIF from post-processing of CFD simulations. From the comparison of experimental and synthetic OH-PLIF images, CFD is shown to replicate much of the flow structure observed in the experiments, revealing potential differences in turbulent length scales and OH kinetics. Furthermore, results provide significant advancement in experimental resolution of these harsh turbulent combustion environments and validate physical models thereof.

Detonator↗

Spatially Resolved Mapping of Oxygen Reduction/evolution Reaction on Solid-Oxide Fuel Cell Cathodes with sub-10 nm Resolution

Spatial localization of the oxygen reduction/evolution reactions (ORR/OER) on lanthanum strontium cobaltite (LSCO) surfaces with perovskite and layered perovskite structures is studied on the sub-10 nanometer level. Comparison between Electrochemical Strain Microscopy (ESM) and structural imaging by scanning transmission electron microscopy (STEM) suggest that small-angle grain boundaries act as regions with enhanced electrochemical activity. The ESM activity is compared across a family of LSCO samples, demonstrating excellent agreement with macroscopic behaviors. This study potentially paves the way for deciphering the mechanisms of electrochemical activity of solids on the level of single extended structural defects such as grain boundaries and dislocations.

Electrochemical Strain microcsopy↗