Search NASA⌕ Search

SEARCH · Search NASA

Results for “Mask”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

DIRECTIONAL VARIATIONS OF THE NON-GAUSSIANITY PARAMETER f{sub NL}

We investigate local variations of the primordial non-Gaussianity parameter f{sub NL} in the WMAP data, looking for possible influence of foreground contamination in the full-sky estimate of f{sub NL}. We first improve the needlet bispectrum estimate in Rudjord et al. on the full sky to f{sub NL} = 73 +- 31 using the KQ75 mask on the co-added V + W channel. We find no particular values of f{sub NL} estimates close to the galactic plane and conclude that foregrounds are unlikely to affect the estimate of f{sub NL} in the V and W bands even for the smaller KQ85 mask. In the Q band, however, we find unexpectedly high values of f{sub NL} in local estimates close to the galactic mask, as well as significant discrepancies between Q-band estimates and V/W-band estimates. We therefore conclude that the Q band is too contaminated to be used for non-Gaussianity studies even with the larger KQ75 mask. We further note that the local f{sub NL} estimates on the V + W channel are positive on all equatorial bands from the north to the south pole. The probability for this to happen in a universe with f{sub NL} = 0 is less than 1%.

79 ASTRONOMY AND ASTROPHYSICS↗

High performance Lyot and PIAA coronagraphy for arbitrarily shaped telescope apertures

Two high-performance coronagraphic approaches compatible with segmented and obstructed telescope pupils are described. Both concepts use entrance pupil amplitude apodization and a combined phase and amplitude focal plane mask to achieve full coronagraphic extinction of an on-axis point source. While the first concept, called Apodized Pupil Complex Mask Lyot Coronagraph (APCMLC), relies on a transmission mask to perform the pupil apodization, the second concept, called Phase-Induced Amplitude Apodization complex mask coronagraph (PIAACMC), uses beam remapping for lossless apodization. Both concepts theoretically offer complete coronagraphic extinction (infinite contrast) of a point source in monochromatic light, with high throughput and sub-λ/D inner working angle, regardless of aperture shape. The PIAACMC offers nearly 100% throughput and approaches the fundamental coronagraph performance limit imposed by first principles. The steps toward designing the coronagraphs for arbitrary apertures are described for monochromatic light. Designs for the APCMLC and the higher performance PIAACMC are shown for several monolith and segmented apertures, such as the apertures of the Subaru Telescope, Giant Magellan Telescope, Thirty Meter Telescope, the European Extremely Large Telescope, and the Large Binocular Telescope. Performance in broadband light is also quantified, suggesting that the monochromatic designs are suitable for use in up to 20% wide spectral bands for ground-based telescopes.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurements of E-mode polarization and temperature-E-MODE correlation in the cosmic microwave background from 100 square degrees of SPTPOL data

We present measurements of E-mode polarization and temperature-E-mode correlation in the cosmic microwave background using data from the first season of observations with SPTpol, the polarization-sensitive receiver currently installed on the South Pole Telescope (SPT). The observations used in this work cover 100 deg{sup 2} of sky with arcminute resolution at 150 GHz. We report the E-mode angular auto-power spectrum (EE) and the temperature-E-mode angular cross-power spectrum (TE) over the multipole range 500 < ℓ ≤ 5000. These power spectra improve on previous measurements in the high-ℓ (small-scale) regime. We fit the combination of the SPTpol power spectra, data from Planck, and previous SPT measurements with a six-parameter ΛCDM cosmological model. We find that the best-fit parameters are consistent with previous results. The improvement in high-ℓ sensitivity over previous measurements leads to a significant improvement in the limit on polarized point-source power: after masking sources brighter than 50 mJy in unpolarized flux at 150 GHz, we find a 95% confidence upper limit on unclustered point-source power in the EE spectrum of D{sub ℓ}=ℓ(ℓ+1)C{sub ℓ}/2π<0.40 μK{sup 2} at ℓ=3000, indicating that future EE measurements will not be limited by power from unclustered point sources in the multipole range ℓ<3600, and possibly much higher in ℓ.

79 ASTRONOMY AND ASTROPHYSICS↗

Proximity field nanopatterning of azopolymer thin films

A method for inscribing surface relief gratings in azopolymer thin films via proximity field nanopatterning is reported. Azopolymers prepared by ring opening metathesis polymerization were cast as thin films and brought into conformal contact with transparent polydimethylsiloxane phase masks. Irradiation of the film surface through the phase masks induces mass transport of azopolymer that generates surface relief structures on the basis of the intensity modulation of the light by structures on the phase mask. The experimental images obtained matched well with those produced by optical simulation. Here, a wide variety of structures could be inscribed in the film surface which depended on the molecular weight of the azopolymer and irradiation time. Control experiments conducted suggest that the process is entirely photonic and that the presence of the phase mask on the film surface did not affect the inscription process.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Non-Gaussianity in the foreground-reduced CMB maps

A detection or nondetection of primordial non-Gaussianity by using the cosmic microwave background radiation (CMB) data is crucial not only to discriminate inflationary models but also to test alternative scenarios. Non-Gaussianity offers, therefore, a powerful probe of the physics of the primordial Universe. The extraction of primordial non-Gaussianity is a difficult enterprise since several effects of a nonprimordial nature can produce non-Gaussianity. Given the far-reaching consequences of such a non-Gaussianity for our understanding of the physics of the early Universe, it is important to employ a range of different statistical tools to quantify and/or constrain its amount in order to have information that may be helpful for identifying its causes. Moreover, different indicators can in principle provide information about distinct forms of non-Gaussianity that can be present in CMB data. Most of the Gaussianity analyses of CMB data have been performed by using part-sky frequency, where the mask is used to deal with the galactic diffuse foreground emission. However, full-sky map seems to be potentially more appropriate to test for Gaussianity of the CMB data. On the other hand, masks can induce bias in some non-Gaussianity analyses. Here we use two recent large-angle non-Gaussianity indicators, based on skewness and kurtosis of large-angle patches of CMB maps, to examine the question of non-Gaussianity in the available full-sky five-year and seven-year Wilkinson Microwave Anisotropy Probe (WMAP) maps. We show that these full-sky foreground-reduced maps present a significant deviation from Gaussianity of different levels, which vary with the foreground-reducing procedures. We also make a Gaussianity analysis of the foreground-reduced five-year and seven-year WMAP maps with a KQ75 mask, and compare with the similar analysis performed with the corresponding full-sky foreground-reduced maps. This comparison shows a significant reduction in the levels of non-Gaussianity when the mask is employed, which provides indications on the suitability of the foreground-reduced maps as Gaussian reconstructions of the full-sky CMB.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Precision Control of the Electron Longitudinal Bunch Shape Using an Emittance-Exchange Beam Line

We report on the experimental generation of relativistic electron bunches with a tunable longitudinal bunch shape. A longitudinal bunch-shaping (LBS) beam line, consisting of a transverse mask followed by a transverse-to-longitudinal emittance exchange (EEX) beam line, is used to tailor the longitudinal bunch shape (or current profile) of the electron bunch. The mask shapes the bunch’s horizontal profile, and the EEX beam line converts it to a corresponding longitudinal profile. The Argonne wakefield accelerator rf photoinjector delivers electron bunches into a LBS beamline to generate a variety of longitudinal bunch shapes. The quality of the longitudinal bunch shape is limited by various perturbations in the exchange process. We develop a simple method, based on the incident slope of the bunch, to significantly suppress the perturbations

Ha, G.↗

Isolating p- and n-Doped Fingers With Intrinsic Poly-Si in Passivated Interdigitated Back Contact Silicon Solar Cells

Polycrystalline silicon on silicon oxide (poly-Si/SiO x ) passivating contacts enable ultra high efficiency interdigitated back contact silicon solar cells. To prevent shunt between n- and p-type doped fingers, an insulating region is required between them. We evaluate the use of intrinsic poly Si for this isolation region. Interdigitated fingers were formed by plasma deposition of doped hydrogenated amorphous silicon through mechanically aligned shadow masks, on top of a full-area intrinsic amorphous silicon layer. High temperature annealing then crystallized the a-Si:H to poly Si and drove in the dopants. Two mechanisms were identified which cause contamination of the intrinsic poly Si gap during processing. During deposition of doped fingers, we show using secondary ion mass spectrometry and conductivity measurements that the intrinsic gap becomes contaminated by doped a-Si:H tails several nanometers thick to concentrations of ~10 20 cm -3 . Another source of contamination occurs during high-temperature annealing, where dopants desorb from doped regions and readsorb onto intrinsic a Si:H. Both pathways reduce the resistivity of the intrinsic gap from ~10 5 Ω·cm to ~10 -1 Ω·cm. We show that plasma etching of the a-Si:H surface before crystallizing with a capping layer can eliminate the contamination of the intrinsic poly-Si, maintaining a resistivity of ~10 5 Ω·cm. Lastly, this demonstrates masked plasma deposition as a dopant patterning method for Si solar cells.

14 SOLAR ENERGY↗

Improved Localization Precision and Angular Resolution of a Cylindrical, Time-Encoded Imaging System From Adaptive Detector Movements

To the first order, the localization precision and angular resolution of a cylindrical, time-encoded imaging (c-TEI) system is governed by the geometry of the system. Improving either measure requires increasing the mask radius or decreasing the detector diameter, both of which are undesirable. Here, we propose an alternative option of repositioning the detector within the mask to increase the detector-to-mask distance in the direction of a source, thereby improving the localization precision and angular resolution in that direction. Since the detector-to-mask distance only increases for a small portion of the field of view (FOV), we propose implementing adaptive imaging where one leverages data collected during the measurement to optimize the system configuration. This article utilizes both simulations and experiments to set upper bounds on the potential gain from adaptive detector movements for one and two sources in the FOV. When only one source is present, adaptive detector movements can improve the localization precision and angular resolution by 20% for a source at 90 cm and by 32% for a far-field source. When two sources are present, adaptive detector movements can improve localization precision and angular resolution by up to 50% for sources that are ~10° apart (90 cm from the system). We experimentally verify these results through maximum likelihood estimation of the source position(s) and image reconstruction of point sources that are close together. As a demonstration of an adaptive imaging algorithm, we image a complex arrangement of special nuclear material at the Zero Power Physics Reactor facility at Idaho National Laboratory.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Nanopatterning of ultrananocrystalline diamond thin films via block copolymer lithography.

Nanopatterning of diamond surfaces is critical for the development of diamond-based microelectromechanical system/nanoelectromechanical system (MEMS/NEMS), such as resonators or switches. Micro-/nanopatterning of diamond materials is typically done using photolithography or electron beam lithography combined with reactive ion etching (RIE). In this work, we demonstrate a simple process, block copolymer (BCP) lithography, for nanopatterning of ultrananocrystalline diamond (UNCD) films to produce nanostructures suitable for the fabrication of NEMS based on UNCD. In BCP lithography, nanoscale self-assembled polymeric domains serve as an etch mask for pattern transfer. The authors used thin films of a cylinder-forming organic-inorganic BCP, poly(styrene-block-ferrocenyldimethylsilane), PS-b-PFS, as an etch mask on the surface of UNCD films. Orientational control of the etch masking cylindrical PFS blocks is achieved by manipulating the polymer film thickness in concert with the annealing treatment. We have observed that the surface roughness of UNCD layers plays an important role in transferring the pattern. Oxygen RIE was used to etch the exposed areas of the UNCD film underneath the BCP. Arrays of both UNCD posts and wirelike structures have been created using the same starting polymeric materials as the etch mask.

36 MATERIALS SCIENCE↗

Intracranial CT angiography obtained from a cerebral CT perfusion examination

CT perfusion (CTP) examinations of the brain are performed increasingly for the evaluation of cerebral blood flow in patients with stroke and vasospasm after subarachnoid hemorrhage. Of the same patient often also a CT angiography (CTA) examination is performed. This study investigates the possibility to obtain CTA images from the CTP examination, thereby possibly obviating the CTA examination. This would save the patient exposure to radiation, contrast, and time. Each CTP frame is a CTA image with a varying amount of contrast enhancement and with high noise. To improve the contrast-to-noise ratio (CNR) we combined all 3D images into one 3D image after registration to correct for patient motion between time frames. Image combination consists of weighted averaging in which the weighting factor of each frame is proportional to the arterial contrast. It can be shown that the arterial CNR is maximized in this procedure. An additional advantage of the use of the time series of CTP images is that automatic differentiation between arteries and veins is possible. This feature was used to mask veins in the resulting 3D images to enhance visibility of arteries in maximum intensity projection (MIP) images. With a Philips Brilliance 64 CT scanner (64x0.625 mm) CTP examinations of eight patients were performed on 80 mm of brain using the toggling table technique. The CTP examination consisted of a time series of 15 3D images (2x64x0.625 mm; 80 kV; 150 mAs each) with an interval of 4 s. The authors measured the CNR in images obtained with weighted averaging, images obtained with plain averaging, and images with maximal arterial enhancement. The authors also compared CNR and quality of the images with that of regular CTA examinations and examined the effectiveness of automatic vein masking in MIP images. The CNR of the weighted averaged images is, on the average, 1.73 times the CNR of an image at maximal arterial enhancement in the CTP series, where the use of plain averaging increases the CNR only with a factor of 1.49. The quality of the weighted averaged images approaches that of CTA images, although in the present study the image quality of CTA was not quite reached. The automatic masking of veins is effective and only small remnants of veins were sometimes present in the masked images. Weighted averaging makes it possible to create CTA images from a CTP examination with a CNR considerably higher than that of images with maximal arterial enhancement. The quality of the resulting images approaches that of CTA images and offers the additional advantages to automatically differentiate between arteries and veins.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The impacts of dental filling materials on RapidArc treatment planning and dose delivery: Challenges and solution

Purpose: The presence of high-density material in the oral cavity creates dose perturbation in both downstream and upstream directions at the surfaces of dental filling materials (DFM). In this study, the authors have investigated the effect of DFM on head and neck RapidArc treatment plans and delivery. Solutions are proposed to address (1) the issue of downstream dose perturbation, which might cause target under dosage, and (2) to reduce the upstream dose from DFM which may be the primary source of mucositis. In addition, an investigation of the clinical role of a custom-made plastic dental mold/gutter (PDM) in sparing the oral mucosa and tongue reaction is outlined.Methods: The influence of the dental filling artifacts on dose distribution was investigated using a geometrically well-defined head and neck intensity modulated radiation therapy (IMRT) verification phantom (PTW, Freiberg, Germany) with DFM inserts called amalgam, which contained 50% mercury, 25% silver, 14% tin, 8% copper, and 3% other trace metals. Three RapidArc plans were generated in the Varian Eclipse System to treat the oral cavity using the same computer tomography (CT) dataset, including (1) a raw CT image, (2) a streaking artifacts region, which was replaced with a mask of 10 HU, and (3) a 2 cm-thick 6000 HU virtual filter [a volume created in treatment planning system to compensate for beam attenuation, where the thickness of this virtual filter is based on the measured percent depth dose (PDD) data and Eclipse calculation]. The dose delivery for the three plans was verified using Gafchromic-EBT2 film measurements. The custom-made PDM technique to reduce backscatter dose was clinically tested on four head and neck cancer patients (T3, N1, M0) with DFM, two patients with PDM and the other two patients without PDM. The thickness calculation of the PDM toward the mucosa and tongue was purely based on the measured upstream dose. Patients’ with oral mucosal reaction was clinically examined initially and weekly during the course of radiotherapy.Results: For a RapidArc treatment technique, the backscatter dose from the DFM insert was measured to be 9.25 ± 2.17 in the IMRT-verification-phantom. The measured backscatter upstream dose from DFM for a single-field was 22% higher than without the DFM, whereas the downstream dose was lower by 14%. The values of homogeneity index for the plans with and without the application of mask were 0.09 and 0.14, respectively. The calculated mean treatment planning volume (PTV) dose differed from the delivered dose by 13% and was reduced to 2% when using the mask and virtual filter together. A grade 3 mucosa reaction was observed in the control group after 22–24 fractions (44–48 Gy). In contrast, no grade 3 mucositis was observed in the patients wearing the PDM after 25–26 fractions (50–52 Gy).Conclusions: The backscatter from the DFM for a single, parallel-opposed fields, and RapidArc treatment technique was found significant. The application of mask in replacing streaking artifacts can be useful in improving dose homogeneity in the PTV. The use of a virtual filter around the teeth during the planning phase reduces the target underdosage issue in the phantom. Furthermore, a reduction in mucositis is observed in the head and neck patients with the use of PDM.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-D-213-04: Accounting for Volume Averaging and Material Composition Effects in An Ionization Chamber Array for Patient Specific QA

Purpose: This study explores novel methods to address two significant challenges affecting measurement of patient-specific quality assurance (QA) with IBA’s Matrixx Evolution™ ionization chamber array. First, dose calculation algorithms often struggle to accurately determine dose to the chamber array due to CT artifact and algorithm limitations. Second, finite chamber size and volume averaging effects cause additional deviation from the calculated dose. Methods: QA measurements were taken with the Matrixx positioned on the treatment table in a solid-water Multi-Cube™ phantom. To reduce the effect of CT artifact, the Matrixx CT image set was masked with appropriate materials and densities. Individual ionization chambers were masked as air, while the high-z electronic backplane and remaining solid-water material were masked as aluminum and water, respectively. Dose calculation was done using Varian’s Acuros XB™ (V11) algorithm, which is capable of predicting dose more accurately in non-biologic materials due to its consideration of each material’s atomic properties. Finally, the exported TPS dose was processed using an in-house algorithm (MATLAB) to assign the volume averaged TPS dose to each element of a corresponding 2-D matrix. This matrix was used for comparison with the measured dose. Square fields at regularly-spaced gantry angles, as well as selected patient plans were analyzed. Results: Analyzed plans showed improved agreement, with the average gamma passing rate increasing from 94 to 98%. Correction factors necessary for chamber angular dependence were reduced by 67% compared to factors measured previously, indicating that previously measured factors corrected for dose calculation errors in addition to true chamber angular dependence. Conclusion: By comparing volume averaged dose, calculated with a capable dose engine, on a phantom masked with correct materials and densities, QA results obtained with the Matrixx Evolution™ can be significantly improved. In addition, necessary correction factors are reduced, allowing for more reliable and meaningful patient-specific QA measurements.

60 APPLIED LIFE SCIENCES↗

SU-E-T-659: Quantitative Evaluation of Patient Setup Accuracy of Stereotactic Radiotherapy with the Frameless 6D-ExacTrac System Using Statistical Modeling

Purpose: To evaluate patient setup accuracy and quantify individual and cumulative positioning uncertainties associated with different hardware and software components of the stereotactic radiotherapy (SRS/SRT) with the frameless-6D-ExacTrac system. Methods: A statistical model was used to evaluate positioning uncertainties of the different components of SRS/SRT treatment with the BrainLAB 6D-ExacTrac system using the positioning shifts of 35 patients having cranial lesions (49 total lesions treated in 1, 3, 5 fractions). All these patients were immobilized with rigid head-and-neck masks, simulated with BrainLAB-localizer and planned with iPlan treatment planning system. Infrared imaging (IR) was used initially to setup patients. Then, stereoscopic x-ray images (XC) were acquired and registered to corresponding digitally-reconstructed-radiographs using bony-anatomy matching to calculate 6D-translational and rotational shifts. When the shifts were within tolerance (0.7mm and 1°), treatment was initiated. Otherwise corrections were applied and additional x-rays were acquired (XV) to verify that patient position was within tolerance. Results: The uncertainties from the mask, localizer, IR-frame, x-ray imaging, MV and kV isocentricity were quantified individually. Mask uncertainty (Translational: Lateral, Longitudinal, Vertical; Rotational: Pitch, Roll, Yaw) was the largest and varied with patients in the range (−1.05−1.50mm, −5.06–3.57mm, −5.51−3.49mm; −1.40−2.40°, −1.24−1.74°, and −2.43−1.90°) obtained from mean of XC shifts for each patient. Setup uncertainty in IR positioning (0.88,2.12,1.40mm, and 0.64,0.83,0.96°) was extracted from standard-deviation of XC. Systematic uncertainties of the localizer (−0.03,−0.01,0.03mm, and −0.03,0.00,−0.01°) and frame (0.18,0.25,−1.27mm,−0.32,0.18, and 0.47°) were extracted from means of all XV setups and mean of all XC distributions, respectively. Uncertainties in isocentricity of the MV radiotherapy machine were (0.27,0.24,0.34mm) and kV-imager (0.15,−0.4,0.21mm). Conclusion: A statistical model was developed to evaluate the individual and cumulative systematic and random uncertainties induced by the different hardware and software components of the 6D-ExacTrac-system. The immobilization mask was associated with the largest positioning uncertainty.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Selective Epitaxial Growth of III–N Structures Using Ion-Beam Nanolithography

The selective epitaxial growth of GaN by metalorganic vapor-phase epitaxy combined with ion-beam etching is investigated. To this end, partially masked GaN epitaxial layers are fabricated by depositing a thin Si{sub 3}N{sub 4} layer onto the surface in a single technological process with the growth of GaN and the subsequent opening of windows of different shapes in this layer by an ion beam. Selective epitaxial growth regimes are studied. It is shown that, in a situation where the total area of the windows in the mask is small relative to the total area of the sample, the required epitaxy duration should be 5–10 s, which impairs the reproducibility of the parameters of the epitaxial process. It is also shown that the mechanism of the selective growth of submicrometer objects differs significantly from that for planar layers and selectively grown layers with dimensions of ~1 μm or greater. The effect of precursor (trimethylgallium and ammonia) fluxes on the character of selective epitaxy is examined. To investigate the possibilities of varying mask topology for fabricating model objects with regard to photonic crystals, the impact of the shape and orientation of the windows in the Si{sub 3}N{sub 4} mask on the character of selective epitaxy is studied.

36 MATERIALS SCIENCE↗

Scanning ARM Cloud Radars. Part II: Data Quality Control and Processing

The Scanning ARM Cloud Radars (SACR’s) are the primary instruments for documenting the four-dimensional structure and evolution of clouds within a 20-30 km radius from the ARM fixed and mobile sites. Here, the post-processing of the calibrated SACR measurements is discussed. First, a feature mask algorithm that objectively determines the presence of significant radar returns is described. The feature mask algorithm is based on the statistical properties of radar receiver noise. It accounts for atmospheric emission and is applicable even for SACR profiles with few or no signal-free range gates. Using the nearest-in-time atmospheric sounding, the SACR radar reflectivities are corrected for gaseous attenuation (water vapor and oxygen) using a line-by-line absorption model. Despite having a high pulse repetition frequency, the SACR has a narrow Nyquist velocity limit and thus Doppler velocity folding is commonly observed. An unfolding algorithm that makes use of a first guess for the true Doppler velocity using horizontal wind measurements from the nearest sounding is described. The retrieval of the horizontal wind profile from the HS-RHI SACR scan observations and/or nearest sounding is described. The retrieved horizontal wind profile can be used to adaptively configure SACR scan strategies that depend on wind direction. Several remaining challenges are discussed, including the removal of insect and second-trip echoes. The described algorithms significantly enhance SACR data quality and constitute an important step towards the utilization of SACR measurements for cloud research.

climate↗

Adaptive methods of generating complex light arrays

Structured light arrays of various shapes have been a cornerstone in optical science, driven by the complexities of precise and adaptable generation. This study introduces an approach using a spatial light modulator (SLM) as a generator for these arrays. By projecting a holographic mask onto the SLM, it functions simultaneously as an optical convolution device, focusing mechanism, and structured light beam mask. Our approach offers unmatched versatility, allowing for the experimental fabrication of traditional beam arrays like azimuthal Laguerre–Gaussian (LG), Bessel–Gaussian (BG), and Hermite–Gauss (HG) in the far-field. Notably, it has enabled a method of generating Ince–Gauss (IG) and LG radial mode beam arrays using a convolution solution. Our system provides exceptional control over array periodicity and intensity distribution, bypassing the Talbot self-imaging phenomenon seen in traditional setups. We provide an in-depth theoretical discussion, supported by empirical evidence, of our far-field results. This method has vast potential for applications in optical communication, data processing, and multi-particle manipulation. It paves the way for rapid generation of structured light with high spatial frequencies and complex shapes, promising transformative advances in these domains.

Optics↗

Pan-arctic river bank erosion and accretion, and planform metrics measured over intervals ranging from 1973 to 2016

This dataset provides the tabular summary of analysis of 17 reaches of 15 Arctic rivers for river bank erosion and accretion rates, as well as, river channel properties such as channel width, bank curvature, and the aspect/orientation of the river banks. These rivers include the: Chandalar River, Alaska, Colville River, Alaska; Indigirka River, Russia; Kolyma River, Russia; Koyukuk River, Alaska; Lena River, Alaska; Noatak River, Alaska; Ob River, Russia; Pechora River, Russia; Tanana River, Alaska, Selawik River, Alaska; Taz River, Russia; Yana River, Russia; Yenisei River, Russia; and the Yukon River, Alaska. The dataset was generated from a total of 129 images including: Landsat, higher resolution satellite imagery, and aerial photography over time periods ranging from the 1970s and 2016. A full list of the image dates, row and path (for Landsat), and pixel resolutions is provided in the dataset. Masks for the Chandalar River, Tanana River, and Yukon at Holy Cross were obtained from Brown et al. (2020). The masks were analyzed using the Spatially Continuous Riverbank Erosion and Accretion Measurements (SCREAM) software detailed in Rowland et al. 2016. The masks used in this analysis can be found an accompanying dataset (doi:10.15485/1571527).In files with “summary” in the name, the data is provided at a pixel level, where each mapped bank pixel has an associated erosion or accretion value, a channel width, a curvature value, and an aspect each river and time period will have an individual file. Files with “Segments” in name provide data that is averaged along segments of the rivers. These data are consolidated into a single file each for the erosion and accretion measurements. These segments are approximately 10 channel widths in length. In addition to erosion and accretion rates, the segment-based results include area measurements of erosion and accretion, islands, and channels. Revisions 2023:-Data added for the Koyukuk River for time periods of 1978-2012, 1978-2018, and 2012-2018. ---Data added from the Chandalar River, Tanana River, and Yukon River at Holy Cross based on masks obtained from Brown et al. (2020).-Updated the values for Drainage area and river slope, see methods below-Added values for meant topographic slope for upstream contributing area, long term averaged annual maximum monthly flow, average annual maximum monthly flow for the time period of erosion record, and added the river slope extracted from the Lin et al. (2020) data product.-Add field for River Planform Multi threaded (M) or Single threaded-Added ‘ConsolidatedErosionSegments.csv’ which provides the same data as AllRiversErosionSegments.csv rebinned with averages along river segments based on upstream drainage area instead of channel segments based on lengths set to approximately 10 channel widths.

54 ENVIRONMENTAL SCIENCES↗

Dynamically Downscaled (WRF) 1km, Hourly Meteorological Conditions 1987-2020. East/Taylor Watersheds

This dataset contains meteorological output from the Weather Research and Forecasting (WRF) version 3.8.1. This dataset has been created to 1) investigate hydrometeorological processes impacting the East River and water-delivery to the Critical Zone, and 2) provide meteorological forcing data for distributed Earth-science modeling applications in the East River watershed. Variables have a 1 kilometer spatial resolution and hourly temporal resolution and encompass a rectangular region encompassing the East and Taylor River watersheds, Colorado, near the town of Crested Butte. WRF was forced using Climate Forecast System Reanalysis (CFSR) lateral boundary conditions. Each .zip file contains one "water year" of data (October 1 -- September 30; i.e. water year 2017 starts October 1, 2016 and ends September 30, 2017). Each zip folder contains 12 netcdf (.nc) files containing one month of hourly data each and are approximately 250mb. Model timestamps are in UTC time.The files contain the following data variables:EAST_MASK: binary mask of the watershed regionTAYLOR_MASK: binary mask of the watershed regionGLW downwelling longwave radiation (w/m2)HR_PRCP: Hourly Precipitation Rate (mm/hr). Includes all hydrometeors (solid+liquid). HFX NoahMP LSM total grid-cell modelled sensible heat flux (w/m2) [positive towards atmosphere]LH NoahMP LSM total grid-cell modelled latent heat flux (w/m2) [positive towards atmosphere; can be converted to ET]PSFC Surface Barometric Pressure (hPa)Q2 Two-meter specific humidity (kg/kg)SWDOWN Downwelling shortwave solar radiation (w/m2)SWNORM Terrain-normal downwelling shortwave radiation (w/m2)T2 Two-meter air temperature (deg K)U10 10-m U-component of wind velocity (m/s)V10 10m V-component of wind velocity (m/s)XLAT Latitude of grid-center point XLONG Longitude of grid-center point XTIME Model timestamp, **in UTC**

54 ENVIRONMENTAL SCIENCES↗