Search NASA⌕ Search

SEARCH · Search NASA

Results for “Padding”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

On the operational meaning and practical aspects of using the security parameter in quantum key distribution

We discuss the operational meaning of a commonly accepted security parameter in quantum key distribution, which is based on the trace distance. We separately consider the cases of using a key in a one-time pad and in a computationally secure cipher. Some practical aspects of using the security parameter are also elucidated, which are usually not paid enough attention in theoretical studies and which therefore may cause difficulties for experimentalists and engineers. It is shown that a one-time pad requires not only a higher key generation rate than computationally secure ciphers, but also a significantly stronger condition on the key security parameter. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design and evaluation of an open-source, conformable skin-cooling system for body magnetic resonance guided focused ultrasound treatments

Magnetic resonance guided focused ultrasound (MRgFUS) treatment of tumors uses inter-sonication delays to allow heat to dissipate from the skin and other near-field tissues. Despite inter-sonication delays, treatment of tumors close to the skin risks skin burns. This work has designed and evaluated an open-source, conformable, skin-cooling system for body MRgFUS treatments to reduce skin burns and enable ablation closer to the skin. A MR-compatible skin cooling system is described that features a conformable skin-cooling pad assembly with feedback control allowing continuous flow and pressure maintenance during the procedure. System performance was evaluated with hydrophone, phantom and in vivo porcine studies. Sonications were performed 10 and 5 mm from the skin surface under both control and forced convective skin-cooling conditions. 3D MR temperature imaging was acquired in real time and the accumulated thermal dose volume was measured. Gross analysis of the skin post-sonication was further performed. Device conformability was demonstrated at several body locations. Hydrophone studies demonstrated no beam aberration, but a 5–12% reduction of the peak pressure due to the presence of the skin-cooling pad assembly in the acoustic near field. Phantom evaluation demonstrated there is no MR temperature imaging precision reduction or any other artifacts present due to the coolant flow during MRgFUS sonication. The porcine studies demonstrated skin burns were reduced in size or eliminated when compared to the control condition. An open-source design of an MRgFUS active skin cooling system demonstrates device conformability with a reduction of skin burns while ablating superficial tissues.

60 APPLIED LIFE SCIENCES↗

NONRESONANT INTERACTION OF CHARGED ENERGETIC PARTICLES WITH LOW-FREQUENCY NONCOMPRESSIVE TURBULENCE: NUMERICAL SIMULATION

A new method for simulating the three-dimensional dynamics of charged energetic particles in very broadband noncompressive magnetic turbulence is introduced. All scales within the primary inertial range of the turbulence observed in the solar wind near 1 AU are now included for the independent computations of both the particle dynamics and the turbulent magnetic field lines (MFLs). While previous theories of resonant particle pitch-angle (PA) scattering and transport in interplanetary magnetic fields had favored interpreting the observed depletions in the electron PA distributions (PADs) around 90 Degree-Sign PA as evidence of poor scattering at low PA cosines, the computed particle dynamics reveal a very different reality. The MFL directions now vary on many scales, and the PADs are depleted around 90 Degree-Sign PA due to nonresonant filtering of the particles that propagate at too large an angle to the local magnetic field. Rather than being too weak, the scattering through 90 Degree-Sign PA is actually so strong that the particles (electrons and protons/ions) are reflected and trapped in the turbulent magnetic fields. While the low-frequency nonresonant turbulence produces ubiquitous magnetic traps that only let through particles with the most field-aligned velocities, higher-frequency near-gyroscale turbulence, when present, enhances particle transport by allowing the particles to navigate between magnetic traps. Finally, visualizing both particle trajectories and MFLs in the very same turbulence reveals a powerful tool for understanding the effects of the turbulent fields on the particle dynamics and cross-field transport. Some cross-field-line scattering, strongly amplified by MFL dispersal, results in a strong cross-field scattering of the particles. From this visualization, it also appears that near-gyroscale turbulence, previously known as gyroresonant turbulence, does not resonantly interact with the particles. The interaction between particles and fields at or near the gyroscale, though potentially strong, does not actually involve the periodic driving of a true resonance.

79 ASTRONOMY AND ASTROPHYSICS↗

BIDIRECTIONAL FLUXES OF NEARLY RELATIVISTIC ELECTRONS DURING THE ONSET OF SOLAR ENERGETIC PARTICLE EVENTS

We report intensity and anisotropy measurements of energetic electrons in the energy range of {approx}27-{approx}500 keV as observed with the Wind and Advanced Composition Explorer (ACE) spacecraft in 2000 June for several solar energetic particle (SEP) events. The solar sources of the SEP events are inferred from observations from the Solar and Heliospheric Observatory spacecraft. All of the events originate from the western limb active regions (ARs), which are well connected by interplanetary magnetic field (IMF) lines linking the Sun to near-Earth space. The observations on board Wind show bimodal pitch angle distributions (PADs), whereas ACE shows PADs with one peak, as is usually observed for impulsive injection of electrons at the Sun. During the time of observations, Wind was located, upstream of the Earth's bow shock in the dawn-noon sector, at distances of {approx}40-{approx}80 R{sub E} from the Earth, and we infer that it was magnetically connected to the quasi-parallel bow shock. Meanwhile, ACE, orbiting the Sun-Earth libration point L1, was not connected to the bow shock. The electron intensity-time profiles and the energy spectra show that the backstreaming electrons observed at Wind are not of magnetospheric origin. The observations suggest rather that the bidirectional electron fluxes are due to reflection or scattering by an obstacle located at a distance of less than {approx}150 R{sub E} in the anti-sunward direction, which is compatible with the obstacle being the Earth's bow shock or magnetosheath.

79 ASTRONOMY AND ASTROPHYSICS↗

COMPARISON BETWEEN PATH LENGTHS TRAVELED BY SOLAR ELECTRONS AND IONS IN GROUND-LEVEL ENHANCEMENT EVENTS

We have examined the Wind/3DP/SST electron and Wind/EPACT/LEMT ion data to investigate the path length difference between solar electrons and ions in the ground-level enhancement (GLE) events in solar cycle 23. Assuming that the onset time of metric type II or decameter-hectometric (DH) type III radio bursts is the solar release time of non-relativistic electrons, we have found that within an error range of {+-}10% the deduced path length of low-energy ({approx}27 keV) electrons from their release site near the Sun to the 1 AU observer is consistent with the ion path length deduced by Reames from the onset time analysis. In addition, the solar longitude distribution and IMF topology of the GLE events examined are in favor of the coronal mass ejection-driven shock acceleration origin of observed non-relativistic electrons. We have also found an increase of electron path lengths with increasing electron energies. The increasing rate of path lengths is correlated with the pitch angle distribution (PAD) of peak electron intensities locally measured, with a higher rate corresponding to a broader PAD. The correlation indicates that the path length enhancement is due to the interplanetary scattering experienced by first arriving electrons. The observed path length consistency implies that the maximum stable time of magnetic flux tubes, along which particles transport, could reach 4.8 hr.

79 ASTRONOMY AND ASTROPHYSICS↗

Fabrication and performance of AC-coupled LGADs

Detectors that can simultaneously provide fine time and spatial resolution have attracted wide-spread interest for applications in several fields such as high-energy and nuclear physics as well as in low-energy electron detection, photon science, photonics and imaging. Low-Gain Avalanche Diodes (LGADs), being fabricated on thin silicon substrates and featuring a charge gain of up to 100, exhibit excellent timing performance. Since pads much larger than the substrate thickness are necessary to achieve a spatially uniform multiplication, a fine pad pixelation is difficult. To overcome this limitation, the AC-coupled LGAD approach was introduced. In this type of device, metal electrodes are placed over an insulator at a fine pitch, and signals are capacitively induced on these electrodes. At Brookhaven National Laboratory, we have designed and fabricated prototypes of AC-coupled LGAD sensors. The performance of small test structures with different particle beams from radioactive sources are shown.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced data readout technique for Multianode Position Sensitive Photomultiplier Tube applicable in radiation imaging detectors

Most of the best performing PSPMT tubes from Hamamatsu and Burle are designed with a pad-matrix anode layout. However, for obtaining a high resolution, a small-sized anode photomultiplier tubes are preferable; these tubes may have 64, 256 or 1024 anodes per tube. If the tubes are used in array to get a larger area detector, the number of analog channels may range from hundreds to thousands. Multichannel analog readout requires special electronics ICs, ASICs etc., which are attached to multichannel DAQ system. As a result, the data file and data processing time will be increased. Therefore, this readout could not be performed in a small project. Usually, most of radiation imaging applications allow the use of analog data processing in front-end electronics, significantly reducing the number of the detector's output lines to data acquisition without reducing the image quality. The idea of pad-matrix decoupling circuit with gain correction was invented and intensively tested in JLab. Several versions of PSPMT readout electronics were produced and studied. All developments were done and optimized specifically for radiation imaging projects. They covered high resolution SPECT, high speed PET, fast neutron imaging, and single tube and multi tube array systems. This paper presents and discusses the summary of the observed results in readout electronics evaluation with different PSPMTs and radiation imaging systems, as well as the advantages and limitations of the developed approach to radiation imaging detectors readout.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Imaging ring-current wave packets in the helium atom

We study the reconstruction of a wave packet and the corresponding electron dynamics in an atom via photoelectron angular distributions (PADs) in a pump-probe scheme as a function of time delay. The method is applied to the superposition of ground and one or two excited states in helium atom representing field-free charge migrations on the attosecond timescale in form of ring currents around the core. It is based on the interference between one- and two-photon transitions from ground and excited states into the continuum. In the reconstruction predictions of first- and second-order perturbation theory are used to determine the unknown phases and amplitudes from the PADs, which we simulate via solutions of the time-dependent Schrödinger equation in single-active-electron approximation. Results of calculations show that the reconstruction technique works well for peak laser intensities less than 10 13 W/cm 2 . Knowledge of the electric field of the probe pulse is required with shot-to-shot variations of carrier-to-envelope phase and peak intensity of up to 10% and 20%, respectively. The relevance of different one- and two-photon pathways for the reconstruction as a function of peak intensity and pulse duration is analyzed—specifically their role for ultrashort probe pulses with broad bandwidths.

74 ATOMIC AND MOLECULAR PHYSICS↗

Theoretical study of photoelectron angular distributions in single-photon ionization of aligned N{sub 2} and CO{sub 2}

We calculate photoelectron angular distributions (PADs) resulting from single-photon (43 eV) ionization of molecules that have been transiently aligned with a short laser pulse. The total ionization cross sections of N{sub 2} and CO{sub 2} vs the time delay between the aligning laser pulse and the soft x-ray photon are calculated and compared to experimental results reported by I. Thomann et al. [J. Phys. Chem. A 112, 9382 (2008)]. We present the PADs from these aligned molecules in the laboratory frame which can be compared directly with future experiments from aligned N{sub 2} and CO{sub 2}. The alignment dependence of single-photon ionization, multiphoton ionization, and high-order harmonic generation are also analyzed.

74 ATOMIC AND MOLECULAR PHYSICS↗

Effects of dimerization on the photoelectron angular distribution parameters from chiral camphor enantiomers obtained with circularly polarized vacuum-ultraviolet radiation

As an intermediate state of matter between the free monomeric gas phase and the solid state, clusters may exhibit a specific electronic structure and photoionization dynamics that can be unraveled by different types of electron spectroscopies. From mass-selected ion yield scans measured for photoionization of (R)-camphor, the ionization potentials (IPs) of the monomer (8.66{+-}0.01 eV), and of the homochiral dimer ({<=}8.37{+-}0.01 eV) and trimer ({<=}8.30{+-}0.01 eV) were obtained. These spectra, combined with threshold photoelectron spectroscopy and velocity map ion imaging, allow us to show that the camphor monomer and dimer photoionization channels are decoupled, i.e., that the highest occupied molecular orbital (HOMO) of the dimer does not undergo a dissociative ionization process that would lead to a spurious contribution to the monomer ion channel. Therefore mass selection, as achieved in our imaging photoelectron-photoion coincidence experiments, leads to size selection of the nascent monomer or dimer species. Since both the monomer and dimer are chiral, their photoelectron angular distribution (PAD) not only involves the usual {beta} anisotropy parameter but also a chiral asymmetry parameter b{sub 1} that can generate a forward-backward asymmetry in the PAD. This has been investigated using circularly polarized light (CPL) to record the photoelectron circular dichroism (PECD) in the near-threshold vacuum-ultraviolet (VUV) photoionization region. Analysis of size-selected electron images recorded with left- and right-handed CPL shows that over the first 1.5 eV above the HOMO orbital ionization potentials (IPs), the {beta} parameter is not affected by the dimerization process, while the chiral b{sub 1} parameter shows clear differences between the monomer and the dimer, confirming that PECD is a subtle long-range probe of the molecular potential.

74 ATOMIC AND MOLECULAR PHYSICS↗

Strong-field ionization of a heteronuclear diatomic molecule

We theoretically study strong-field ionization of a heteronuclear diatomic molecule, CO, by calculating the photoelectron angular distributions (PADs) and the total ionization rates using linearly and circularly polarized laser fields. We find that, although the PADs of CO generally do not have inversion symmetry, they become more inversion symmetric as the photoelectron energy increases. Heteronuclear features of CO upon ionization are better understood by comparing the results with those of a representative of homonuclear molecules, N{sub 2}, in that, although there are some similarities between CO and N{sub 2} due to the same orbital symmetry, {sigma}{sub g}, there are some differences between them in terms of the ionization suppression and orientation dependence of the total ionization yield. Namely, CO behaves more like an atom in the low-intensity range in a sense that ionization takes place mainly from the neighborhood of the C core, while it behaves more like a double-core molecule in the high-intensity range since ionization takes place from the neighborhood of both C and O cores. This explains why ionization suppression of CO is not seen at the low intensity but it becomes more visible at the high intensity range.

74 ATOMIC AND MOLECULAR PHYSICS↗

Secure Communication via a Recycling of Attenuated Classical Signals

We describe a simple method of interleaving a classical and quantum signal in a secure communication system at a single wavelength. The system transmits data encrypted via a one-time pad on a classical signal and produces a single-photon reflection of the encrypted signal. This attenuated signal can be used to observe eavesdroppers and produce fresh secret bits. The system can be secured against eavesdroppers, detect simple tampering or classical bit errors, produces more secret bits than it consumes, and does not require any entanglement or complex wavelength division multiplexing, thus, making continuous secure two-way communication via one-time pads practical.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Time projection chamber for GADGET II

The established Gaseous Detector with Germanium Tagging (GADGET) detection system is used to measure weak, low-energy 𝛽-delayed proton decays. It consists of the Gaseous Proton Detector equipped with a MICROMEGAS (MM) readout to detect protons and other charged particles calorimetrically, surrounded by the Segmented Germanium Array (SeGA) for high-resolution detection of prompt 𝛾 rays. To upgrade GADGET's Proton Detector to operate as a compact time projection chamber (TPC) for the detection, three-dimensional imaging and identification of low-energy 𝛽-delayed single- and multiparticle emissions mainly of interest to astrophysical studies. A new high granularity MM board with 1024 pads has been designed, fabricated, installed, and tested. A high-density data acquisition system based on generic electronics for TPCs (GET) has been installed and optimized to record and process the gas avalanche signals collected on the readout pads. The TPC's performance has been tested using a 220 Rn 𝛼-particle source and cosmic-ray muons. In addition, decay events in the TPC have been simulated by adapting the attpcroot data analysis framework. Furthermore, a novel application of two-dimensional convolutional neural networks for GADGET II event classification is introduced. The optimization of data throughput is also addressed. The GADGET II TPC is capable of detecting and identifying 𝛼 particles as well as measuring their track direction, range, and energy. The extracted energy resolution of the GADGET II TPC using P10 gas is about 5.4% at 6.288 MeV ( 220 Rn 𝛼 events), computed using charge integration. Based on a systematic simulation study, we estimated the detection efficiency of the GADGET II TPC for protons and 𝛼 particles, respectively. It has also been demonstrated that the GADGET II TPC is capable of tracking minimum-ionizing particles (i.e., cosmic-ray muons). From these measurements, the electron drift velocity was measured under typical operating conditions. In addition to being one of the first generation of micropattern gaseous detectors (MPGDs) to utilize a resistive anode applied to low-energy nuclear physics, the GADGET II TPC will also be the first TPC surrounded by a high-efficiency array of high-purity germanium 𝛾-ray detectors. As a result, the TPC of GADGET II has been designed, fabricated, and tested and is ready for operation at the Facility for Rare Isotope Beams for radioactive-beam-line experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

X-ray Characterization of a Multichannel Smart-Pixel Array Detector

The Voxtel VX-798 is a prototype X-ray pixel array detector (PAD) featuring a silicon sensor photodiode array of 48 x 48 pixels, each 130 mu m x 130 mu m x 520 mu m thick, coupled to a CMOS readout application specific integrated circuit (ASIC). The first synchrotron X-ray characterization of this detector is presented, and its ability to selectively count individual X-rays within two independent arrival time windows, a programmable energy range, and localized to a single pixel is demonstrated. During our first trial run at Argonne National Laboratory's Advance Photon Source, the detector achieved a 60 ns gating time and 700 eV full width at half-maximum energy resolution in agreement with design parameters. Each pixel of the PAD holds two independent digital counters, and the discriminator for X-ray energy features both an upper and lower threshold to window the energy of interest discarding unwanted background. This smart-pixel technology allows energy and time resolution to be set and optimized in software. It is found that the detector linearity follows an isolated dead-time model, implying that megahertz count rates should be possible in each pixel. Measurement of the line and point spread functions showed negligible spatial blurring. When combined with the timing structure of the synchrotron storage ring, it is demonstrated that the area detector can perform both picosecond time-resolved X-ray diffraction and fluorescence spectroscopy measurements.

CMOS ASIC↗

A Misalignment Tolerant Magnetic Coupler Design and Implementation for Wireless Charging of Unmanned Aerial Vehicles (UAVs)

Wireless power transfer technology is getting more attention these days as a part of expanded battery charging infrastructure and network at a wide range of power levels. Charging Unmanned aerial vehicles (UAVs) is one wireless charging application, and charging their batteries can be challenging because they have short flight times and are frequently charged. For wireless charging of UAVs, the misalignment performance of the magnetic coupler pads is critical because landing on a charging pad at a perfectly aligned position is difficult and can be time-consuming. Different coil shapes and system structures have been proposed in the literature to overcome this challenge. A new design with a high misalignment tolerance is needed; therefore, to fill this gap, a wireless power transfer system has been designed for a 250 W UAV battery charging system with a new magnetic coupler design. A 3D model of the proposed design was created, and finite element simulations were performed. To prove the proposed design, the magnetic coupler prototypes were developed, and experimental results are presented herein. The misalignment tolerance of the proposed system was observed for various rotational positions of the secondary coil, from 0° to 360°. The results demonstrate that DC–DC efficiency varies between 80% and 85% within full 360° rotation of the receiver coil. This result enables the proposed system to address the misalignment problem for wireless charging of UAVs.

UAVs↗

AnalyzeThat: A Programmable Shared-Memory System for an Array of Processing-In-Memory Devices

Processing In Memory (PIM), the concept of integrating processing directly with memory, has been attracting a lot of attention since PIM can assist in overcoming the throughput limitation caused by data movement between CPU and memory. The challenge, however, is that it requires the programmers to have a deep understanding of the PIM architecture to maximize the benefits such as data locality and parallel thread execution on multiple PIM devices. In this study, we present AnalyzeThat, a programmable shared-memory system for parallel data processing with PIM devices. Thematic to AnalyzeThat is a rich PIM-Aware Data Structure (PADS), which is an encapsulation that integrally ties together the data, the analysis tasks and the runtime needed to interface with the PIM device array. The PADS abstraction provides (i) a key-value data container that allows programmers to easily store data on multiple PIMs, (ii) a suite of parallel operations with which users can easily implement data analysis applications, and (iii) a runtime, hidden to programmers, which provides the mechanisms needed to overlay both the data and the tasks on the PIM device array in an intelligent fashion, based on PIM-specific information collected from the hardware. We have developed a PIM emulation framework called AnalyzeThat. Our experimental evaluation with representative data analytics applications suggests that the proposed system can significantly reduce the PIM programming effort without losing its technology benefits.

97 MATHEMATICS AND COMPUTING↗

Severe Temperature Impact Study on Ferrite Electromagnetic Shielding for Wireless Electric Vehicle Charging

Wireless charging of an electric vehicle (EV) is an emerging technology that enables noncontact charging, which has advantages in terms of convenience and flexibility. However, the embedded charging pads under and on the ground expose the charging coils, ferrite shielding, and related components to a potentially severe external environment. To study the electromagnetic shielding performance under such extreme temperature conditions, ferrite shielding material's permeability characteristics are tested under temperatures as low as -50°C to as high as 240°C. Referring to the official recorded lowest and highest temperature of the United States, in this paper, it is assumed that the operation temperature ranges from -50°C to 57°C as the coldest winter and hottest summer environment for WPT application. Electromagnetic performance, shielding, and associated stray magnetic emissions are simulated by using three-dimensional (3D) transient simulations to study the impact of low and high temperature on electromagnetic shielding performance. Based on ferrite testing data, from -50°C low temperature to 57°C high temperature, the ferrite's relative permeability ranges from 2550 to 3727. The simulation study indicates that there won't be significant impact on the EM shielding performance for WPT operated under those severe environment temperature conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dark Lock-in Thermography Identifies Solder Bond Failure as the Root Cause of Series Resistance Increase in Fielded Solar Modules

Correlating the electrical performance of photovoltaic modules to the spatially resolved photoluminescence, electroluminescence, and dark lock-in thermography (DLIT) images is an important long-term goal for developing solar cell technology. These images offer highly sophisticated and detailed information about the spatial distribution and (if imaged at successive time intervals) temporal degradation of local series and shunt resistances. There have been extensive studies to correlate these imaging techniques to local characteristics at the cell level. However, it has been difficult to extract and quantify module-level information from the techniques. In this study, we interpret module current-voltage (I-V) measurements along with corresponding DLIT images within a module-scale simulation framework, demonstrating that series resistance degradation of the module I-V characteristics, in this case, can be attributed to solder bond failures. Our simulations highlight how current crowding associated with a failed solder joint (or a section of the solder pad) translates to the characteristic point-like (asymmetric doublet) heating pattern in neighboring solder joints (or the neighboring regions of the solder pad). Overall, the correlation between series resistance and solder joint degradation could inform expedited diagnosis of field degradation of solar modules.

42 ENGINEERING↗