Velocity Measurements in the Wake of the Swept Wing Flow Test Model at the National Transonic Facility

Femtosecond laser electronic excitation tagging (FLEET) was applied to obtain flowfield velocity data for the Swept Wing Flow Test (SWiFT) at the NASA Langley Research Center National Transonic Facility (NTF). Despite numerous challenges associated with performing flow velocimetry measurements within a large-scale cryogenic wind tunnel facility, the experimental campaign was conducted under various conditions, including dry air at 320 K, cool nitrogen at 240 K, and Mach numbers of 0.2 and 0.8. FLEET velocimetry measurements were performed in the downstream wake of the SWiFT model, providing a quantitative dataset. This dataset includes one-dimensional velocity profiles and two-dimensional velocity maps acquired at different angles of attack and Reynolds numbers. The two-dimensional single component velocity maps indicate relatively uniform flow across the 120-mm wide wake flow survey suggesting that the main flow features can be represented by single-position linear velocity profiles. The measured instantaneous velocity profiles at variable angles of attack are compared to model lift coefficient information obtained at Mach 0.2. At high Reynolds numbers, a sudden velocity decrease was observed in the FLEET measurements at the same time as stall in lift coefficient was observed. At a low Reynolds number, both the velocity profiles and the lift coefficient show a smoother transition, without a sudden stall. Furthermore, the two-dimensional, one component velocity map reveals a velocity deficit region at Mach 0.8 at various angles of attack. Both single shot and mean velocity measurements were acquired allowing assessment of flowfield fluctuations and measurement precisions. The uncertainties are within 4 m/s in mean measurements based on repeatability data and about 5 m/s in instantaneous single-shot measurements. Measurements are reported with ~4.8 mm spatial resolution with 32-pixel averaging used to reduce measurement errors.

femtosecond↗

Velocity Measurements in the Wake of the Swept Wing Flow Test (SWIFT) Model at the National Transonic Facility

Femtosecond laser electronic excitation tagging (FLEET) was applied to obtain flowfield velocity data for the Swept Wing Flow Test (SWiFT) at the NASA Langley Research Center National Transonic Facility (NTF). Despite numerous challenges associated with performing flow velocimetry measurements within a large-scale cryogenic wind tunnel facility, the experimental campaign was conducted under various conditions, including dry air at 320 K, cool nitrogen at 240 K, and Mach numbers of 0.2 and 0.8. FLEET velocimetry measurements were performed in the downstream wake of the SWiFT model, providing a quantitative dataset. This dataset includes one-dimensional velocity profiles and two-dimensional velocity maps acquired at different angles of attack and Reynolds numbers. The two-dimensional single component velocity maps indicate relatively uniform flow across the 120-mm wide wake flow survey suggesting that the main flow features can be represented by single-position linear velocity profiles. The measured instantaneous velocity profiles at variable angles of attack are compared to model lift coefficient information obtained at Mach 0.2. At high Reynolds numbers, a sudden velocity decrease was observed in the FLEET measurements at the same time as stall in lift coefficient was observed. At a low Reynolds number, both the velocity profiles and the lift coefficient show a smoother transition, without a sudden stall. Furthermore, the two-dimensional, one component velocity map reveals a velocity deficit region at Mach 0.8 at various angles of attack. Both single shot and mean velocity measurements were acquired allowing assessment of flowfield fluctuations and measurement precisions. The uncertainties are within 4 m/s in mean measurements based on repeatability data and about 5 m/s in instantaneous single-shot measurements. Measurements are reported with ~4.8 mm spatial resolution with 32-pixel averaging used to reduce measurement errors.

Transonic↗

Instrument technology for magnetosphere plasma imaging from high Earth orbit. Design of a radio plasma sounder

The use of radio sounding techniques for the study of the ionospheric plasma dates back to G. Briet and M. A. Tuve in 1926. Ground based swept frequency sounders can monitor the electron number density (N(sub e)) as a function of height (the N(sub e) profile). These early instruments evolved into a global network that produced high-resolution displays of echo time delay vs frequency on 35-mm film. These instruments provided the foundation for the success of the International Geophysical Year (1958). The Alouette and International Satellites for Ionospheric Studies (ISIS) programs pioneered the used of spaceborne, swept frequency sounders to obtain N(sub e) profiles of the topside of the ionosphere, from a position above the electron density maximum. Repeated measurements during the orbit produced an orbital plane contour which routinely provided density measurements to within 10%. The Alouette/ISIS experience also showed that even with a high powered transmitter (compared to the low power sounder possible today) a radio sounder can be compatible with other imaging instruments on the same satellite. Digital technology was used on later spacecraft developed by the Japanese (the EXOS C and D) and the Soviets (Intercosmos 19 and Cosmos 1809). However, a full coherent pulse compression and spectral integrating capability, such as exist today for ground-based sounders (Reinisch et al., 1992), has never been put into space. NASA's 1990 Space Physics Strategy Implementation Study "The NASA Space Physics Program from 1995 to 2010" suggested using radio sounders to study the plasmasphere and the magnetopause and its boundary layers (Green and Fung, 1993). Both the magnetopause and plasmasphere, as well as the cusp and boundary layers, can be observed by a radio sounder in a high-inclination polar orbit with an apogee greater than 6 R(sub e) (Reiff et al., 1994; Calvert et al., 1995). Magnetospheric radio sounding from space will provide remote density measurements of unprecedented precision and coverage in the plasmasphere, inner magnetosphere and magnetopause, from which the structure, inter-relationship, and variations of different plasma regions can be determined (Armstrong Johnson, 1995). A space-borne Radio Plasma Imager (RPI) could provide a unique global view of the magnetosphere revealing the underlying structure of remote plasma regions, thereby providing a framework for the interpretation of images obtained by other techniques as identified in the technical areas TA1 to TA4 in the MSFC NRA8-8.

Haines, D. Mark↗

Search for 3D topological superconductors using laser-based spectroscopy (Final Technical Report)

The three-dimensional topological superconductor (3D TSC) is a novel quantum phase of matter that is predicted to exhibit exotic thermal and electrical properties, which may serve applications ranging from precision thermal management and sensing technologies to fault-tolerant quantum information processing. Over the past decade, there has been an intensive effort to realize 1D and 2D TSCs by artificially engineering them from combinations of already existing materials. For example, coupling conventional superconductors to spin-orbit coupled 1D nanowires or to 2D topological insulator surfaces by the proximity effect provides a route to realizing 1D and 2D TSCs respectively. However no artificial engineering strategy is available for a 3D TSC. Therefore, current searches are limited to intrinsically superconducting compounds whose topological properties are difficult to predict. The overarching goal of this project was to realize and to identify 3D TSCs in bulk single crystals using novel laser-based spectroscopic techniques. One major thrust was to develop ultralow temperature and ultra-high-resolution angle-resolved photoemission spectroscopy (ARPES) to directly measure the dispersion of Majorana excitations that are predicted to exist on the surfaces of 3D TSCs. Another major thrust was to develop a rational route to realize 3D TSCs by identifying their precursor phases. It is theoretically proposed that the critical fluctuations of certain ordered electronic phases can mediate Cooper pairing in odd-parity channels and lead to topological superconductivity. Therefore, 3D TSCs may potentially emerge upon suppressing these inversion symmetry broken precursor phases to a critical point with external perturbations such as pressure, strain or even light. To test this hypothesis, we studied candidate materials using a suite of symmetry-sensitive optical probes including rotational anisotropy optical second harmonic generation (RA-SHG) and time-resolved coherent phonon spectroscopy, all operable under high-pressure and low temperature environments.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Airborne Antenna System for Minimum-Cycle-Slip GPS Reception

A system that includes a Global Positioning System (GPS) antenna and associated apparatus for keeping the antenna aimed upward has been developed for use aboard a remote-sensing-survey airplane. The purpose served by the system is to enable minimum- cycle-slip reception of GPS signals used in precise computation of the trajectory of the airplane, without having to restrict the airplane to maneuvers that increase the flight time needed to perform a survey. Cycle slip signifies loss of continuous track of the phase of a signal. Minimum-cycle-slip reception is desirable because maintaining constant track of the phase of the carrier signal from each available GPS satellite is necessary for surveying to centimeter or subcentimeter precision. Even a loss of signal for as short a time as a nanosecond can cause cycle slip. Cycle slips degrade the quality and precision of survey data acquired during a flight. The two principal causes of cycle slip are weakness of signals and multipath propagation. Heretofore, it has been standard practice to mount a GPS antenna rigidly on top of an airplane, and the radiation pattern of the antenna is typically hemispherical, so that all GPS satellites above the horizon are viewed by the antenna during level flight. When the airplane must be banked for a turn or other maneuver, the reception hemisphere becomes correspondingly tilted; hence, the antenna no longer views satellites that may still be above the Earth horizon but are now below the equatorial plane of the tilted reception hemisphere. Moreover, part of the reception hemisphere (typically, on the inside of a turn) becomes pointed toward ground, with a consequent increase in received noise and, therefore, degradation of GPS measurements. To minimize the likelihood of loss of signal and cycle slip, bank angles of remote-sensing survey airplanes have generally been limited to 10 or less, resulting in skidding or slipping uncoordinated turns. An airplane must be banked in order to make a coordinated turn. For small-radius, short-time coordinated turns, it is necessary to employ banks as steep as 45 , and turns involving such banks are times and for confining airplanes as closely as possible to areas to be surveyed. The idea underlying the design is that if the antenna can be kept properly aimed, then the incidence of cycle slips caused by loss or weakness of signals can be minimized. The system includes an articulating GPS antenna and associated electronic circuitry mounted under a radome atop an airplane. The electronic circuitry includes a microprocessor-based interface-circuit-and-data-translation module. The system receives data on the current attitude of the airplane from the inertial navigation system of the airplane. The microprocessor decodes the attitude data and uses them to compute commands for the GPS-antenna-articulating mechanism to tilt the antenna, relative to the airplane, in opposition to the roll or bank of the airplane to keep the antenna pointed toward the zenith. The system was tested aboard the hurricane- hunting airplane of the National Oceanic and Atmospheric Administration (NOAA) [see figure] during an 11-hour flight to observe the landfall of Hurricane Bret in late summer of 1999. No bank-angle restrictions were imposed during the flight. Post-flight analysis of the GPS trajectory data revealed that no cycle slip had occurred.considered normal maneuvers. These steep banks are highly desirable for minimizing flight

Wright, C. Wayne↗

A New Cathode Material for a Li–O 2 Battery Based on Lithium Superoxide

Li–O 2 batteries suffer from large charge overpotentials due to the high charge transfer resistance of Li 2 O 2 discharge products. A potential solution to this problem is the development of LiO 2 -based batteries that possess low charge overpotentials due to the lower charge transfer resistance of LiO 2 . In this report, IrLi nanoparticles were synthesized and implemented for the first time as a LiO 2 battery cathode material. The IrLi nanoparticle synthesis was achieved by a temperature- and time-optimized thermal reaction between a precise ratio of iridium nanoparticles and lithium metal. Li–O 2 batteries employing the IrLi-rGO cathodes were cycled up to 100 cycles at moderate current densities with sustained low cell charge potentials (<3.5 V). Further, various characterization techniques, including SEM, DEMS, TEM, Raman, and titration, were used to demonstrate the LiO 2 discharge product and the absence of Li 2 O 2 . On the basis of first-principles calculations, it was concluded that the formation of crystalline LiO 2 can be stabilized by epitaxial growth on the (111) facets of IrLi nanoparticles present on the cathode surface. These findings demonstrate that, in addition to the previously studied Ir 3 Li intermetallic, the IrLi intermetallic also provides a means by which LiO 2 discharge products can be stabilized and confirms the importance of templating for the formation process.

25 ENERGY STORAGE↗

Mysterious SiB 3 : Identifying the Relation between α- and β-SiB 3

Binary silicon boride SiB 3 has been reported to occur in two forms, as disordered and nonstoichiometric α-SiB 3–x , which relates to the α-rhombohedral phase of boron, and as strictly ordered and stoichiometric β-SiB 3 . Similar to other boron-rich icosahedral solids, these SiB 3 phases represent potentially interesting refractory materials. However, their thermal stability, formation conditions, and thermodynamic relation are poorly understood. Here, we map the formation conditions of α-SiB 3–x and β-SiB 3 and analyze their relative thermodynamic stabilities. α-SiB 3–x is metastable (with respect to β-SiB 3 and Si), and its formation is kinetically driven. Pure polycrystalline bulk samples may be obtained within hours when heating stoichiometric mixtures of elemental silicon and boron at temperatures 1200–1300 °C. At the same time, α-SiB 3–x decomposes into SiB6 and Si, and optimum time-temperature synthesis conditions represent a trade-off between rates of formation and decomposition. The formation of stable β-SiB 3 was observed after prolonged treatment (days to weeks) of elemental mixtures with ratios Si/B = 1:1–1:4 at temperatures 1175–1200 °C. The application of high pressures greatly improves the kinetics of SiB 3 formation and allows decoupling of SiB 3 formation from decomposition. Quantitative formation of β-SiB 3 was seen at 1100 °C for samples pressurized to 5.5–8 GPa. β-SiB 3 decomposes peritectoidally at temperatures between 1250 and 1300 °C. The highly ordered nature of β-SiB 3 is reflected in its Raman spectrum, which features narrow and distinct lines. In contrast, the Raman spectrum of α-SiB 3–x is characterized by broad bands, which show a clear relation to the vibrational modes of isostructural, ordered B 6 P. The detailed composition and structural properties of disordered α-SiB 3–x were ascertained by a combination of single-crystal X-ray diffraction and 29 Si magic angle spinning NMR experiments. Notably, the compositions of polycrystalline bulk samples (obtained at T ≤ 1200 °C) and single crystal samples (obtained from Si-rich molten Si–B mixtures at T > 1400 °C) are different, SiB 2.93(7) and SiB 2.64(2) , respectively. The incorporation of Si in the polar position of B 12 icosahedra results in highly strained cluster units. This disorder feature was accounted for in the refined crystal structure model by splitting the polar position into three sites. The electron-precise composition of α-SiB 3–x is SiB 2.5 and corresponds to the incorporation of, on average, two Si atoms in each B 12 icosahedron. Accordingly, α-SiB 3–x constitutes a mixture of B 10 Si 2 and B 11 Si clusters. The structural and phase stability of α-SiB 3–x were explored using a first-principles cluster expansion. The most stable composition at 0 K is SiB 2.5 , which however is unstable with respect to the decomposition β-SiB 3 + Si. Modeling of the configurational and vibrational entropies suggests that α-SiB 3–x only becomes more stable than β-SiB 3 at temperatures above its decomposition into SiB 6 and Si. Hence, we conclude that α-SiB 3–x is metastable at all temperatures. Density functional theory electronic structure calculations yield band gaps of similar size for electron-precise α-SiB 2.5 and β-SiB 3 , whereas α-SiB 3 represents a p-type conductor.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

CODEX Optical Design and Alignment

The COronal Diagnostic EXperiment (CODEX) is a Heliophysics mission to measure the density, temperature, and velocity of the electrons in the solar corona with the primary goal of improving our understanding of the physical conditions of the solar wind in the acceleration region. The temperature and velocity measurement requires much higher signal-to-noise ratio than the density measurements. In solar coronagraphs, the diffraction of the solar disk light due to the occulting element is the dominant source of noise. Therefore, to further suppress the diffracted sun light with respect to the existing coronagraphs is a critical element of the CODEX design. To minimize the stray light due to diffraction, the selected optical design is a two-stage standard coronagraph with an external occulter, an internal occulter, and a Lyot stop. What is unique for this design is that a focal mask was inserted at the telescope focal plane. It works together with the field lens suppressing the stray light down by ~ another order of magnitude as compared to a traditional three-stage approach. During the optical design, a Fourier Transform based beam propagation software, i.e., GLAD, was used to model the beam path through the full coronagraph, from the external occulter to the detector array. All diffraction sensitive elements: external occulter, internal occulter, focal mask, and Lyot stop were carefully modeled and optimized. As a result, the requirement of achieving a stray light level which is one order of magnitude lower than F-corona was satisfied. On the other hand, to achieve the final suppression, a precision optical alignment is another must. This paper also presents our creative alignment procedure: using the combination of metrology, precision alignment equipment, and real time diffraction ring monitoring to minimize the diffraction. The final test results show that the suppression ratio (B/B 0 ) reaches 10 -11 level, which is equivalent to one order of magnitude lower than F-corona.

CODEX optical design and alignment↗

ETROC1: the first full chain precision timing prototype ASIC for CMS MTD endcap timing layer upgrade

We present the design and characterization of the first fullchain precision timing prototype ASIC, named ETL Readout Chipversion 1 (ETROC1) for the CMS MTD endcap timing layer (ETL)upgrade. The ETL utilizes Low Gain Avalanche Diode (LGAD) sensors todetect charged particles, with the goal to achieve a time resolutionof 40–50 ps per hit, and 30–40 ps per track with hits from twodetector layers. The ETROC1 is composed of a 5 × 5 pixelarray and peripheral circuits. The pixel array includes a4 × 4 active pixel array with an H-tree shaped networkdelivering clock and charge injection signals. Each active pixel iscomposed of various components, including a bump pad, a chargeinjection circuit, a pre-amplifier, a discriminator, adigital-to-analog converter, and a time-to-digital converter. Thesecomponents play essential roles as the front-end link in processingLGAD signals and measuring timing-related information. Theperipheral circuits provide clock signals and readoutfunctionalities. The size of the ETROC1 chip is7 mm× 9 mm. ETROC1 has been fabricated in a 65 nmCMOS process, and extensively tested under stimuli of chargeinjection, infrared laser, and proton beam. The time resolution ofbump-bonded ETROC1 + LGAD chipsets reaches 42–46 ps per hit in thebeam test.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compact, Highly Stable Ion Atomic Clock

A mercury-ion clock now at the breadboard stage of development (see figure) has a stability comparable to that of a hydrogen-maser clock: In tests, the clock exhibited an Allan deviation of between 2 x 10(exp -13) and 3 x 10(exp -13) at a measurement time of 1 second, averaging to about 10(exp -15) at 1 day. However, the clock occupies a volume of only about 2 liters . about a hundredth of the volume of a hydrogen-maser clock. The ion-handling parts of the apparatus are housed in a sealed vacuum tube, wherein only a getter pump is used to maintain the vacuum. Hence, this apparatus is a prototype of a generation of small, potentially portable high-precision clocks for diverse ground- and space-based navigation and radio science applications. Furthermore, this new ion-clock technology is about 100 times more stable and precise than the rubidium atomic clocks currently in use in the NAV STAR GPS Earth-orbiting satellites. In this clock, mercury ions are shuttled between a quadrupole and a 16-pole linear radio-frequency trap. In the quadrupole trap, the ions are tightly confined and optical state selection from a Hg-202 radio-frequency-discharge ultraviolet lamp is carried out. In the 16-pole trap, the ions are more loosely confined and atomic transitions resonant at frequency of about 40.507 GHz are interrogated by use of a microwave beam at that frequency. The trapping of ions effectively eliminates the frequency pulling caused by wall collisions inherent to gas-cell clocks. The shuttling of the ions between the two traps enables separation of the state-selection process from the clock microwave- resonance process, so that each of these processes can be optimized independently of the other. The basic ion-shuttling, two-trap scheme as described thus far is not new: it has been the basis of designs of prior larger clocks. The novelty of the present development lies in major redesigns of its physics package (the ion traps and the vacuum and optical subsystems) to effect the desired reduction of size to a volume of no more than a couple of liters. The redesign effort has included selection of materials for the vacuum tube, ion trap, and ultraviolet windows that withstand bakeout at a temperature of approx.450 C in preparation for sealing the tube to contain the vacuum. This part of the redesign effort follows the approach taken in the development of such other vacuum-tube electronic components as flight traveling- wave-tube amplifiers having operational and shelf lives as long as 15 years. The redesign effort has also included a thorough study of residual-gas-induced shifts of the ion-clock frequency and a study of alternative gases as candidates for use as a buffer gas within the sealed tube. It has been found that neon is more suitable than is helium, which has been traditionally used for this purpose, in that the pressure-induced frequency pulling by neon is between a third and a half of that of helium. In addition, because neon diffuses through solids much more slowly than does helium, the loss of neon by diffusion over the operational lifetime is expected to be negligible.

Prestage, John↗

Half-life determination of heavy ions in a storage ring considering feeding and depleting background processes

Heavy-ion storage rings have relatively large momentum acceptance which allows for multiple ion species to circulate at the same time. This needs to be considered in radioactive decay measurements of highly charged ions, where atomic charge exchange reactions can significantly alter the intensities of parent and daughter ions. In this study, we investigate this effect using the decay curves of ion numbers in the recent 205 Tl 81+ bound-state beta decay experiment conducted using the Experimental Storage Ring at GSI Darmstadt. To understand the intricate dynamics of ion numbers, we present a set of differential equations that account for various atomic and nuclear reaction processes—bound state beta decay, atomic electron recombination and capture, and electron ionization. By incorporating appropriate boundary conditions, we develop a set of differential equations that accurately simulate the decay curves of various simultaneously stored ions in the storage ring: 205 Tl 81+ , 205 Pb 81+ , 205 Pb 82+ , 200 Hg 79+ , and 200 Hg 80+ . Through a quantitative comparison between simulations and experimental data, we provide insights into the detailed reaction mechanisms governing stored heavy ions within the storage ring. Our approach effectively models charge-changing processes, reduces the complexity of the experimental setup, and provides a simpler method for measuring the decay half-lives of highly charged ions in storage rings.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Toward quantifying capacity losses due to solid electrolyte interphase evolution in silicon thin film batteries

To understand the origins of failure and limited cycle life in lithium-ion batteries (LIBs), it is imperative to quantitatively link capacity-fading mechanisms to electrochemical and chemical processes. This is extremely challenging in real systems where capacity is lost during each cycle to both active material loss and solid electrolyte interphase (SEI) evolution, two indistinguishable contributions in traditional electrochemical measurements. Here, we have used a model system in combination with (1) precision measurements of the overall Coulombic efficiency via electrochemical experiments and (2) x-ray reflectivity measurements of the active material losses. The model system consisted of a 515 Å thick amorphous silicon (a-Si) thin film on silicon carbide in half-cell geometry using a carbonate electrolyte with LiPF6 salt. This approach allowed us to quantify the capacity lost during each cycle due to SEI evolution. Combined with electrochemical analysis, we identify SEI growth as the major contribution to capacity fading. Specifically, the continued SEI growth results in increasing overpotentials due to increased SEI resistance, and this leads to lower extent of lithiation when the cutoff voltage is reached during lithiation. Our results suggest that SEI grows more with increased time spent at low voltages where electrolyte decomposition is favored. Finally, we extracted a proportionality constant for SEI growth following a parabolic growth law. Our methodology allows for the quantitative determination of lithium-ion loss mechanisms in LIBs by separately tracking lithium ions within the active materials and the SEI and offers a powerful method of quantitatively understanding LIB loss mechanisms.

25 ENERGY STORAGE↗

A novel liquid argon purity monitor based on 207 Bi

A novel liquid argon purity monitor based on a 207 Bi radioactive source, emitting monochromatic internal-conversion electrons, is presented. This new monitor allows for a very precise and fast measurement of the electronegative impurities concentration in liquid argon. It can be operated continuously in liquid argon TPC experiments without interfering with the main detector operation. Different drift lengths can be assembled for the proposed device, to assess a large range of liquid argon purities while minimizing systematic uncertainties. Two prototypes have been built and successfully operated in dedicated test stands. The results and performance are reported.

double-phase↗

Study of the Mu2e sensitivity to the $\mu^-\rightarrow e^+$ conversion process

The Mu2e experiment at Fermilab (Batavia, IL) will search for the coherent neutrinoless conversion of a muon into an electron in the electric field of an aluminum atom. The conversion process results in a monochromatic electron with energy slightly below the muon rest mass ($E_e= 104.97$ MeV). The experiment goal is to improve the previous measurement by four orders of magnitude and reach a single event sensitivity of $3 \times 10^{-17} $ on the conversion rate with respect to the muon capture rate. \\ The experiment will deliver a very intense pulsed negative muon beam to an aluminum target to achieve a total number of $10^{18}$ stopped muons in three years of running. Production and transport of the muons are accomplished with a sophisticated magnetic system comprised of a Production, a Transport and a Detector solenoid, with the last one hosting a Straw-tube Tracker and a Crystal Calorimeter. The entire detector region is surrounded by a Cosmic Ray Veto system. Mu2e is und er construction at the Muon Campus of Fermilab. \\ The INFN italian group is responsible for the design and construction of the crystal calorimeter, which plays a crucial role in the Mu2e measurement, providing particle identification capabilities fundamental for the rejection of the different background sources that can mimic a conversion electron. The calorimeter information allows also to improve the tracking performances it provides a fast standalone trigger for the experiment.\\ After a long R\&D phase, the final drawings see a calorimeter comprised of 1348 pure CsI crystals arranged in two annular disks. Each crystal is readout by two custom UV-extended Silicon Photomultipliers (SiPMs). Performances of the selected components were verified with an electron beam test, carried out in 2017 at the Beam Test Facility (BTF) at the National Laboratories of Frascati, on a large size prototype of 51 crystals and 102 SiPMs, confirming excellent energy ($\sigma_{E}/E = \mathcal{O }(10\%)$) and timing ($\sigma_{T} <500$ ps) resolutions in a! greement with the Mu2e specifications.\\ In the first chapters of this thesis, I describe my involvement in the calorimeter activities, with particular emphasis on the data analysis of the prototype energy response and resolution, that I was personally leading. Moreover, a description of the tuning of the simulation and the careful data-MC comparison is also reported.\\ An auxiliary measurement that can be performed with Mu2e is the search for a Lepton Number Violation (LNV) process where the negatively charged muon converts, without neutrinos, into a positron, $\mu ^{-} +N(A,Z) \rightarrow $ e$^+ +N(A,Z-2)$. At the moment of writing, Neutrinoless Double Beta Decay (0$\nu \beta \beta$) has set the most stringent limit on the LNV processes (T$^{0\nu \beta \beta}_{1/2} > 1.1 \times 10^{26} $ yr at 90$\%$ CL) with the GERDA experiment. In 0$\nu \beta \beta$ a pair of free electrons is created in the transformation from a nucleus $(A, Z)$ into its daughter $(A, Z + 2)$, namely: $(A,Z)\rightarrow (A, Z+2) =2 e^-$. Similar transitions could proceed through the emission of a pair of positrons, double electron capture (EC), or EC and single emission of a positron, with the nucleus changing from $(A, Z)$ to $(A, Z - 2)$. All these variations are equally interesting when discussing of new Physics, since they all manifest a non-conservation of the number of leptons.\\ Moreover, recent studies show that, because of flavor effect, off-diagonal processes, such as the $\mu^- -e^+$ conversion, can have their rate enhanced with respect to processes occurring in the $e-e$ sector.\\ Mu2e will search for $\mu^- + Al(27,13) \rightarrow e^+ +Na(27,11)$, only considering ground state transition, producing a conversion positron with energy $E_{e^+}= 92.32 $ MeV.\\ This thesis is focused on this search. In particular, I developed an algorithm to account for the radiative corrections to be applied to the conversion positrons that resulted in a few percent reduction in s ignal acceptance.\\ One of the most prominent background to ! this sear! ch is the Radiative Muon Capture (RMC) $ \mu+ N(Z,A)\rightarrow \gamma + \nu_{\mu} + N(Z-1,A)$. The produced photon can convert, virtually or in the detector materials (in the following referred as internal or external conversion respectively) in an electron-positron pair, producing positrons with energies approaching the expected conversion energy. Experimental results from previous experiments indicate the RMC endpoint ($\kmax$) to be of $\sim$ 90 MeV. A precise modeling of this background is relevant due to the proximity of the photon spectrum endpoint to the positron conversion energy. The calorimeter group is obviously interested to reconstruct the RMC distribution having also the opportunity to improve the current knowledge of the process. \\ A toy MC has been developed to evaluate the number of $e^+$ from external RMC background in the signal window. Knowing this value and ev...

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Improving Efficacy and Safety of Pharmacological Treatment Through Precision Medicine and Pharmacogenomics for Human Deep Space Exploration

INTRODUCTION: Future spaceflight will require increased crew medical autonomy as exploration class missions expanding duration and distance from Earth, especially for Mars missions. As mission duration increases, it will be even more essential to have appropriate amounts of effective medication to ensure the maintenance of crew health and performance. Conversely, mass and volume constraints will become more severe as future spaceflight expands beyond low Earth orbit, where resupply is difficult or becomes impossible. These constraints thus convey an urgency to further tailor medications included in the spacecraft formulary and increased examination of appropriate dosing regimens. BACKGROUND: Precision Health is an exciting area of cutting-edge research and medicine focused on maintaining an individual’s health and performance through in-depth understanding of an individual’s unique factors and molecular profiles. This approach can be adapted to better predict, monitor, and address physiological responses to the spaceflight environment. One example is the field of pharmacogenomics (PGX),the study of how the expressed genome impacts drug responses with the goal of prescribing the right dose of the right drug at the right time. Specifically, PGX testing provides valuable information on an individual’s precise allelic variations to guide physicians in making informed decisions on pharmaceutical choice and dosing to avoid adverse drug events and maximize pharmacological efficacy. The goal of this study was to evaluate which drugs in the current space pharmacy could be evaluated using PGX testing and to understand the potential impact on the health and wellness of the astronaut population. Additionally, we sought to evaluate clinically available FDA-approved PGX testing solutions to better understand its applicability. METHODS: A complete list of drugs onboard the International Space Station (ISS) was analyzed for risk and likelihood of drug failure and PGX actionability. This analysis encompassed both personal astronaut medications, including supplements and over the counter drugs (n=151) and ISS MedKit formulary medications (n=95). Duplicate medications and different formulations were removed, which resulted in 157 total drugs used in the subsequent analysis. A 5x5 risk assessment table was produced by examining the likelihood of drug failure compared to the consequence of drug failure. Likelihood of individual drug failure was defined by whether existing processes are sufficient to prevent adverse events, as ranked from 1 (very low, can easily be prevented) to 5 (very high, cannot be prevented) during a Mars mission. In contrast, the consequence of drug failure was defined by impact to safety, schedule, cost or technical and ranked from 1 (very low) to 5 (very high).A comprehensive assessment of commercially available PGX solutions is currently underway to evaluate specimen requirements, cost/benefit analysis (cost vs. number of alleles assessed), utility of variant analysis, relevance to inflight medication usage, quality of reporting in enabling clinical application, and ease of integration into electronic medical records. RESULTS: Risk assessments(LxC 5x5 table) indicated29medicationswere in the yellow or red zone driven predominantly by drug failure or safety concerns, with the remainder(n=128)of the medications in the green zone where risk is acceptable. We found that current PGX testing results could impact 21% of the total medications in the ISS MedKit and IMAK; of these, 9 medications currently have direct clinically actionable guidance available. Results of the clinical PGX solution evaluations as related to these medications will be presented. CONCLUSION: PGX testing has demonstrated clear benefits in terrestrial medicine and clinical environments for the selection of proper medications, avoiding adverse drug reactions, and maximizing drug efficacy. We propose that similar benefits would be bestowed on the astronaut and commercial spaceflight passenger population by performing preemptive pre-flight PGX testing to reduce risk of mission failure due to ineffective or toxic medications, improve targeting drug efficacy and safety, and further open the door to countermeasure research exploring PGX-related allelic variants. For example, PGX results could allow tailoring of specific medications at optimal doses more precisely to each individual astronaut, particularly in areas of space motion sickness, sleep aids, and analgesics. An additional benefit is that PGX results could provide information for better planning of the components of a space pharmacy for deep space missions to be more cost effective and more efficient in the utilization of limited pharmaceutical resources. Finally, while PGX testing of the astronaut corps is not currently conducted, this approach could provide immediate impact in support of mission success by reducing risks, optimizing astronaut performance, and providing valuable insights into long-term astronaut health. Such advancements in clinical decision making are important next steps in building dynamic individual risk profiles for astronauts, increasing crew autonomy and providing tailored countermeasures

Alice R W Tang↗

Describing Point Defect Topology in 2D Energy Materials Through Computer Vision

Point defects such as vacancies and impurity atoms strongly impact the performance of 2D materials. Traditional efforts often rely on manual detection, a process that is time-intensive, prone to human error, and challenging to scale. Here we leverage machine learning (ML) methods to identify and quantify vacancies within 2D transition metal carbides (Ti3C2, MXenes), aiming to expedite detection while improving accuracy. MXenes exhibit valuable defect-defined electrochemical properties, but we currently lack statistical understanding of defect topology needed to fully harness these materials. Here we employ a convolutional neural network for semantic segmentation of experimental MXene images, opening an opportunity to conduct a rigorous statistical study on defect hierarchy while investigating local relaxation in the lattice. We show how the integration of ML can yield fundamental insight into point defects, providing a powerful tool that will play an increasingly crucial role in the future of materials science. ML is often not just a matter of straightforward application, and pretrained models proved ineffective in this case. Instead, we trained our own neural network (NN) and applied data augmentation techniques and fine-tuning to the training dataset. Since labeled microscopy data is often scarce, we developed training data from a previously published wide-frame MXene image, using customized Gaussian fitting to locate atomic positions. Our trained model was then applied to a large dataset of experimental images, enabling a statistical study of defect configurations across three samples prepared with different HF etchant concentrations (5%, 9.1%, and 12.5%), as shown in Fig. 1. This also allowed us to investigate local strain around vacancies, though we find that we are limited by the precision of measurements using high-angle annular dark field (HAADF) images, as shown in Fig. 2. This study demonstrates how ML enables large-scale, quantitative analysis of atomic defects - an otherwise infeasible task with traditional methods. While our NN was specialized for Ti3C2 MXenes, the pipeline we developed provides a foundation for future ML models tailored to other materials. Ultimately, we envision embedding the NN onto the microscope to give real-time feedback to the user. To make this a reality, continued work is necessary to fully understand the NN's capabilities and limitations. This study gets one step closer to our goals of automated experimentation moving away from traditional methods of manual labeling. As ML capabilities advance, we hope to continue adapting and applying these techniques in microscopy.

2D materials↗

Development and Operation of a Material Identification and Discrimination Imaging Spectroradiometer

Many imaging applications require quantitative determination of a scene's spectral radiance. This paper describes a new system capable of real-time spectroradiometric imagery. Operating at a full-spectrum update rate of 30Hz, this imager is capable of collecting a 30 point spectrum from each of three imaging heads: the first operates from 400 nm to 950 nm, with a 2% bandwidth; the second operates from 1.5 micro-m to 5.5 micro-m with a 1.5% bandwidth; the third operates from 5 micro-m to 12 micro-m, also at a 1.5% bandwidth. Standard image format is 256 x 256, with 512 x 512 possible in the VIS/NIR head. Spectra of up to 256 points are available at proportionately lower frame rates. In order to make such a tremendous amount of data more manageable, internal processing electronics perform four important operations on the spectral imagery data in real-time. First, all data in the spatial/spectral cube of data is spectro-radiometrically calibrated as it is collected. Second, to allow the imager to simulate sensors with arbitrary spectral response, any set of three spectral response functions may be loaded into the imager including delta functions to allow single wavelength viewing; the instrument then evaluates the integral of the product of the scene spectral radiances and the response function. Third, more powerful exploitation of the gathered spectral radiances can be effected by application of various spectral-matched filtering algorithms to identify pixels whose relative spectral radiance distribution matches a sought-after spectral radiance distribution, allowing materials-based identification and discrimination. Fourth, the instrument allows determination of spectral reflectance, surface temperature, and spectral emissivity, also in real-time. The spectral imaging technique used in the instrument allows tailoring of the frame rate and/or the spectral bandwidth to suit the scene radiance levels, i.e., frame rate can be reduced, or bandwidth increased to improve SNR when viewing low radiance scenes. The unique challenges of design and calibration are described. Pixel readout rates of 160 MHz, for full frame readout rates of 1000 Hz (512 x 512 image) present the first challenge; processing rates of nearly 600 million integer operations per second for sensor emulation, or over 2 billion per second for matched filtering, present the second. Spatial and spectral calibration of 66,536 pixels (262,144 for the 512 x 512 version) and up to 1,000 spectral positions mandate novel decoupling methods to keep the required calibration memory to a reasonable size. Large radiometric dynamic range also requires care to maintain precision operation with minimum memory size.

Dombrowski, Mark↗

Improving Efficacy and Safety of Pharmacological Treatment Through Precision Health and Pharmacogenomics

INTRODUCTION: Future spaceflight will require increased crew medical autonomy as exploration class missions expand in duration and distance from Earth, especially for Mars missions. As mission duration increases, it will be essential to have appropriate amounts of effective medication to ensure the maintenance of crew health and performance. Conversely, mass and volume constraints will become more severe as future spaceflight expands beyond low Earth orbit, where resupply is difficult or becomes impossible. These constraints thus convey an urgency to tailor medications for individual crewmembers and further examine appropriate dosing regimens. BACKGROUND: Precision Health is an exciting area of medicine focused on maintaining an individual’s health and performance through in-depth understanding of an individual’s unique clinical and environmental history, genetic makeup, and molecular profiles. This approach can be adapted to better predict, monitor, and address physiological responses to the spaceflight environment. A subset of this field is pharmacogenomics (PGX), the study of how the expressed genome impacts drug responses with the goal of prescribing the right dose of the right drug at the right time. Specifically, PGX testing provides valuable information on an individual’s precise allelic variations to guide physicians in making informed decisions on drug choice and dosing to avoid adverse events and maximize efficacy. The study goal was to identify which current space pharmacy drugs could be evaluated using PGX testing and to understand the potential impact on the health and wellness of the astronaut population. Additionally, we sought to evaluate clinically available FDA-approved PGX testing solutions to better understand its applicability. METHODS: A complete list of drugs on the ISS was analyzed for risk and likelihood of drug failure and PGX actionability. This analysis encompassed both astronauts’ personal medications, including supplements and over the counter drugs (n=151) contained in the ISS medical accessory kit (IMAK), and ISS MedKit formulary medications (n=95). Duplicate medications and different formulations were removed, which resulted in a total of 157 drugs used in the subsequent analysis. A 5x5 risk assessment table was produced by examining the likelihood of drug failure compared to the consequence of drug failure (LxC). Likelihood of individual drug failure was defined by whether existing processes are sufficient to prevent ineffective treatment or impactful side effect events, as ranked from 1 (very low, can easily be prevented) to 5 (very high, cannot be prevented) during a Mars mission. In contrast, the consequence of drug failure was defined by impact to safety, schedule, cost, or technical criteria and ranked from 1 (very low) to 5 (very high). An assessment of PGX reference laboratories is currently underway to evaluate sample requirements, benefit analysis (cost vs. utility of allele variant analysis), relevance to inflight medication usage, quality of reporting in enabling clinical application, and ease of integration into electronic medical records. RESULTS: Risk assessments (LxC 5x5 table) indicated 128 medications were in the green zone where risk is acceptable, with the remaining 29 of the medications in the yellow or red zone driven predominantly due to drug failure or safety concerns. We found that current PGX testing results could impact 21% of the total medications in the ISS MedKit and IMAK; of these, 9 medications currently have direct clinically actionable guidance available. Results of the clinical PGX solution evaluations as related to these medications will be presented. CONCLUSION: PGX testing has demonstrated clear benefits in terrestrial medicine and clinical environments for the selection of proper medications, avoiding adverse drug reactions, and maximizing drug efficacy. We propose that similar benefits would be bestowed on the astronaut and commercial spaceflight passenger population by performing preemptive preflight PGX testing to reduce risk of mission failure due to ineffective or toxic medications, improve drug efficacy, and further open the door to countermeasure research. For example, PGX results could allow tailoring of specific medications at optimal doses more precisely to each individual astronaut, particularly in areas of space motion sickness, sleep aids, and analgesics. An additional benefit is that PGX results could provide information for better planning of the components of a space pharmacy for deep space missions to be more effective and efficient in the utilization of limited pharmaceutical resources. Finally, while PGX testing of the astronaut corps is not currently conducted, this approach could provide immediate impact in support of mission success by reducing risks, optimizing astronaut performance, and providing valuable insights into long-term astronaut health. Such advancements in clinical decision making are important next steps in building dynamic individual risk profiles for astronauts, increasing selection of the best treatment choice, and providing tailored countermeasures for individual crewmembers.